Vertical Pumps 50hz

download Vertical Pumps 50hz

of 36

Transcript of Vertical Pumps 50hz

  • 8/2/2019 Vertical Pumps 50hz

    1/36

    vertical pumps 50 Hz

    technical data

    dp pumps

  • 8/2/2019 Vertical Pumps 50hz

    2/36

    Content

    Model identification 1

    Features 2

    Applications 3

    Material specification 4

    Pump connections 5

    Shaft seal 6

    Motor specifications 7

    Dimensions and curves

    DPV 2 / DPVE 2 8

    DPV 4 / DPVE 4 10

    DPV 10 12

    DPV 14 Low speed motor 14

    DPV 18 16

    DPVF 24 Low speed motor 18

    DPVF 32 20

    DPVF 45 22

    DPVF 65 24

    DPLHS 6High pressure 26

    Notes 28

    dppumps is ISO-9001

    and ISO-14001 certified.

    Excellence in stainless

    For decades DP-Pumps has been specialised

    in vertical pumps.

    A Dutch company in competition with big multi-

    nationals in the world market.

    The success of DP-Pumps lies in the innova-

    tion of her products coming from a combination

    of smart thinking and common sense.

    The optimal involvement of our employees plus

    a natural urge for improvement creates an

    environment in which Total Quality

    Management is self-evident.

    The latest result of DP-Pumps' R&D depart-

    ment is the vertical pump DPVE, a pump

    specially developed for booster sets, which

    from now on will set the trend.

    Excellence instainless steel technologyThe most exceptional merit of the DPV series

    is that all wetted parts are made of stainless

    steel AISI 304 (DPV series) or stainless steel

    AISI 316 (DPVS series).

    For normal water the DPV series (stainless

    steel AISI 304) fulfils, for water containing more

    aggressive elements the DPVS series (stain-

    less steel AISI 316) will be appropriate.

    The existing deep draw and welding

    technology has been significantly improved.

    Through this technology more durable and

    lighter stainless steel pump parts can be pro-

    duced. The use of stainless steel for all wetted

    parts prevents corrosion.

    DPVE

    Stainless steel pumps

    02

  • 8/2/2019 Vertical Pumps 50hz

    3/36

    Innovate with vision Of course DP-Pumps is there toserve you with tailor made advice.

    Please feel free to contact us.

    teel technology

    One solution for many applications

    Traditionally the building industry is one of themost important application fields for vertical

    pumps.

    The service friendly, compact DPVE has been-

    specially developed for booster sets, but also

    for sprinklers, fire-fighting and airconditioning

    installations. Some of the applications in which

    DPV pumps can be used are: water treatment,

    boiler feed, cleaning appliances, cooling and

    marine applications.

    DPV 14 and DPV 24:

    low noise level,long working life.In numerous cases extra demands are speci-

    fied in relation to the noise level of pumps.

    Specially for applications in housing, DP-

    Pumps developed a low-speed pump. The

    DPV14 and DPV24 are equipped with a 1425

    min-1 motor.Not only producing a particularly

    low noise level, but also guaranteeing an extra

    long working life. The other DPV types are

    equipped with 2850 min-1 motors.

    03

  • 8/2/2019 Vertical Pumps 50hz

    4/36

    FEATURES

    Top bracket

    One-piece casting ensures maxi-

    mum stability. Stainless steel inlay

    for maximum corrosion resistance.The height of the top bracket is

    related to the shaft seal and the

    electrical motor connection.

    Shaft sealingSpring loaded DIN seal with bellow

    construction and the fit to purpose

    material combinations, ensure long

    lifetime. For models with heavy

    motors a cartridge version is provid-

    ed, which enables seal exchange

    without removing the motor.

    Suction discharge casing

    The separate base plate has under-

    gone a special corrosion resistence

    treatment. Entire housing made ofstainless steel. Flange connection

    rotates to match flange and bolt ori-

    entation. Victaulic connection

    available on selected series.

    Built-in check valve

    The DPVE suction discharge casing

    has an integrated check valve.

    Construction with less partsforquick & easy assembly

    04

  • 8/2/2019 Vertical Pumps 50hz

    5/36

    Sleeve sealingSleeve construction ensures total

    compensation of thermal expansion.

    Specially shaped o-ring grooves for

    optimal sealing.

    Stainless steel pump shaftFlat faces on shaft for strong

    shaft/impeller construction.

    Stainless steel diffuser

    Special design reduces internal

    losses, which improves the efficien-

    cy of the pump.

    Pump shaft bearings

    A combination of tungsten-carbide

    and ceramic is used for the pumpshaft bearing.

    Tailormade solutions

    05

  • 8/2/2019 Vertical Pumps 50hz

    6/36

    Booster sets

    Boiler feed

    Water treatment

    Irrigation

    Sprinkler installations

    Carwash

    Fire fighting

    Cooling water transport

    Marine applications

    Chemical industry

    Processing industry

    Food processing industry

    APPLICATIONS

    06

  • 8/2/2019 Vertical Pumps 50hz

    7/36

    MODEL IDENTIFICATION

    dp pumps www.dp-pumps.com

    Pumptype DPVS F 45 - 50 - 1

    Basic materials DPV DP Vertical pumps in AISI 304 (1.4301).

    DPVEDP Vertical pumps in AISI 304 (1.4301).

    Male thread with built-in non-return valve on discharge side.

    DPVS DP Vertical pumps in superior grade AISI 316 (1.4401).

    DPLHS DP Vertical pumps in superior grade AISI 316 (1.4401) 40 Bar.

    Pump connections Oval counterflanges with female thread (DPLHS round flanges).

    F Round flanges DIN, JIS or ANSI.

    V Victaulic connection.

    Model/flow 45 Pump model indicates nominal flow in [M3/h].

    Stages/head - 50 Indicates number of impeller stages (50=5).

    - 1 One stage with half head impeller (only available on DPVF 45).

    120

    15 m3/h

    Selectionexample: 15 m3/h - 120 m. (selected: DPV 18)

    07

  • 8/2/2019 Vertical Pumps 50hz

    8/36

    MATERIAL SPECIFICATION

    08

    Pumpseries DPVE DPV DPVS DPLHS

    Material specification

    Pump shaft and bushes AISI 303 (1.4305) AISI 316 (1.4401)

    Impeller, diffuser,

    suction/dischargecasing, sleeve

    AISI 304 (1.4301) AISI 316L (1.4404)

    Base plate GG20 (GJL-200) GG25 (GJL-250) -

    Top bracket GG25 (GJL-250) AISI 316 (1.4408)

    (Collar) flange - GGG40 (GJS-400) AISI 316 (1.4408)

    Elastomers EPDM Viton

    Liquid lubricated

    bearings- ceramic/tungsten-carbide

    Deareating

    and drain plugbrass AISI 316 (1.4401)

    Duty range

    Temperature range [oC] -15 to 60 -15 to 120

    Max. ambienttemperature [oC]

    50

  • 8/2/2019 Vertical Pumps 50hz

    9/36

    PUMP CONNECTIONS

    dp pumps www.dp-pumps.com

    Pump series DPVE DPV(S) DPV(S)F DPV(S)V DPLHS

    Pressure class PN10 PN16 PN25 PN40

    Connections male thread oval flange round sliding flange victaulic connection round cast flange

    Norm G NEN ISO 228 G NEN ISO 228 DIN EN 1092-2 PN25 - DIN EN 1092-2 PN40

    Optional - Rc NEN EN 10226ANSI B 16.1 cl.250

    JIS B2238 16K- ANSI B 16.5 cl. 600

    Counter-

    connectionsoptional

    oval counterflangeincluded

    (female thread)optional

    DPVE 2 G 112 - - - -

    DPVE 4 G 112 - - - -

    DPV 2 - G 1 DN 25 32 mm -

    DPV 4 - G 114 DN 32 32 mm -

    DPV 10 - G 112 DN 40 50 mm -

    DPV 14 - G 114 - 50 mm -

    DPV 18 - G 2 DN 50 50 mm -

    DPVF 24 - - DN 65 - -

    DPVF 32 - - DN 65 - -

    DPVF 45 - - DN 80 - -

    DPVF 65 - - DN 100 - -

    DPLHS 6 - - - - DN 40

    09

  • 8/2/2019 Vertical Pumps 50hz

    10/36

    SHAFT SEAL

    Shaft seal

    Pump seriesDPV(S)

    DPVE

    DPV(S)F 24, 32, 45

    > 7,5 kW andDPV(S)F 65 range

    DPLHS 6

    Seal type bellow sealbellow /

    cartridge seal

    spring loaded high

    pressure seal

    According to (norm) DIN 24960

    max. working

    pressure

    1000 [kPa]

    Carbon -

    -

    -

    -

    - Tungsten carbide

    Secondary sealings DPV EPDM -

    Secondary sealings

    DPVS and DPLHSViton

    Options

    Dynamic part Silicon carbide -

    Stationary part Silicon carbide -

    Secondary sealings Viton or EPDM -

    max. working

    pressure

    2500 [kPa]max. working

    pressure

    4000 [kPa]

    Silicon carbide

    Silicon carbide

    Carbon

    -

    -

    Carbon

    dynamic

    stationary

    dynamic

    stationary

    dynamic

    stationary

    10

  • 8/2/2019 Vertical Pumps 50hz

    11/36

    MOTOR SPECIFICATIONS

    Motor specifications:

    Specially developed three-phase improved efficiency motors according to IEC standard.

    Nominal power supply [V] : 380 and 420

    Frequency [Hz] : 50

    Nominal rotation speed [min-1] : 1425 or 2850

    Protection class : IP55

    Insulation class : F

    Efficiency class : eff2

    dp pumps www.dp-pumps.com11

    P[kW]

    [%]

    n[min-1]

    Lp

    [dB(A)]

    Max.

    Starts

    [h-1]

    220V 230V 240V 380V 400V 420V 660V 692V 725V

    I max[A]

    P[kW

    ]

    [%]

    n[min-1]

    Lp

    [dB(A)]

    Max.

    Starts[h-1]

    220V 230V 240V 380V 400V 420V 660V 692V 725V

    I max[A]

    2 Pole - 3 Phase 50Hz

    4 Pole - 3 Phase 50Hz

    0,37 2730 1,9 1,8 1,8 1,1 1,1 1,070,0 64 50

    0,55 2765 2,8 2,7 2,6 1,6 1,6 1,575,0 64 50

    0,75 2890 3,6 3,5 3,3 2,1 2,0 1,979,0 66 50

    1,10 2920 5,2 5,0 4,8 3,1 2,9 2,884,0 66 50

    1,50 2840 7,1 6,8 6,4 4,1 3,9 3,778,0 65 30

    2,20 2845 9,9 9,4 8,9 5,7 5,4 5,281,5 65 30

    3,00 2895 12,6 12,0 11,4 7,3 6,9 6,683,5 67 204,00 2915 16,3 15,5 14,7 9,4 8,9 8,585,0 69 20

    5,50 2910 22,8 21,6 20,6 13,2 12,5 11,986,0 69 15

    7,50 2900 28,6 27,1 25,9 16,5 15,7 15,087,0 69 12

    11,00 2935 46,0 43,9 42,4 26,5 25,4 24,588,5 76 11

    15,00 2930 59,0 55,7 53,6 34,0 32,2 31,090,0 76 10

    18,50 2940 72,0 67,9 65,7 41,5 39,2 38,091,0 76 10

    22,00 2935 84,5 81,3 77,8 49,0 46,9 45,091,0 76 10

    30,00 2945 96,7 92,5 88,7 56,0 53,2 50,791,5 84 6

    37,00 2951 116,9 111,9 107,2 67,7 64,3 61,392,2 86 6

    4,2 4,0 3,85,4 5,2 4,9

    7,6 7,2 6,9

    9,6 9,1 8,6

    15,3 14,7 14,2

    19,7 18,6 17,9

    24,0 22,6 22,0

    28,3 27,1 26,0

    35,8 34,3 32,6

    39,0 38,0 38,0

    0,55 1390 2,8 2,7 2,5 1,6 1,5 1,470,0 58 50

    0,75 1385 3,6 3,4 3,3 2,1 2,0 1,974,0 58 50

    1,10 1415 5,7 5,4 5,2 3,3 3,1 3,076,0 58 50

    1,50 1420 7,3 7,0 6,7 4,3 4,1 3,978,5 58 50

    2,20 1420 10,3 9,8 9,4 6,0 5,7 5,481,0 62 50

    3,00 1415 13,3 13,3 12,1 7,7 7,7 7,082,7 62 15

    4,00 1445 16,9 17,0 15,6 9,8 10,0 9,084,5 62 15

    5,50 1450 22,8 21,7 21,7 13,2 12,5 12,586,0 62 10

    7,50 1455 30,4 30,4 30,5 17,6 17,6 17,687,5 62 10

    11,00 1450 41,9 41,9 41,9 24,2 24,2 24,288,5 64 10

    15,00 1460 57,2 52,9 51,0 33,0 30,5 29,590,0 64 10

    4,5 4,5 4,0

    5,8 5,8 5,2

    7,6 7,2 7,2

    10,6 10,2 10,2

    12,5 14,0 14,0

    19,1 17,7 17,0

  • 8/2/2019 Vertical Pumps 50hz

    12/36

    DPV 2

    DPVE 2

    12

    DPVE

    Pumptype

    DPV(S)(F)(V)(E)

    Motorpower

    [kW]

    DimensionsE1

    [mm]

    DimensionsE2

    [mm]

    Shippingvolume

    [m3]

    DimensionsF1

    [mm]

    DimensionsF1

    [mm]

    DimensionsF2

    [mm]

    Netweight

    [kg]

    Netweight

    [kg]

    DPVEDPV(S)(V)General

    DimensionsF1

    [mm]

    DimensionsF2

    [mm]

    Netweight

    [kg]

    DPV(S)F

    Grossweight

    [kg]

    Grossweight

    [kg]

    Grossweight

    [kg]

    DimensionsE1

    [mm]

    DimensionsE2

    [mm]

    2- 10 0,37 431433 232 138 110 1113 13170,042 458 257 14 16143 93

    2- 20 0,37 431433 232 138 110 1113 13170,042 458 257 14 16143 93

    2- 30 0,37 452454 253 138 110 1214 14170,042 479 278 14 16143 93

    2- 40 0,55 473475 274 138 110 1315 15190,042 500 299 16 18143 93

    2- 50 0,55 494496 295 138 110 1416 16190,042 521 320 16 18143 93

    2- 60 0,75 554553 326 156 120 1917 21210,049 578 351 18 201 60 1 01

    2- 70 0,75 574 347 18 210,049 599 372 18 211 60 1 01

    2- 80 1,10 595 368 20 230,049 620 393 20 221 60 1 01

    2- 90 1,10 616 389 20 240,049 641 414 21 231 60 1 01

    2- 100 1,10 637 410 21 240,049 662 435 22 241 60 1 01

    2- 110 1,10 658 431 21 250,055 683 456 24 241 60 1 01

    2- 130 1,50 739 483 27 310,055 764 508 28 301 74 1 42

    2- 150 1,50 781 525 28 320,069 806 550 29 311 74 1 42

    2- 160 2,20 827 546 31 350,069 852 571 32 351 74 1 42

    2- 180 2,20 869 588 32 360,069 894 613 33 361 74 1 42

    2- 200 2,20 911 630 33 370,069 936 655 34 371 74 1 42

    2- 230 3,00 1017 703 43 490,114 1042 728 44 491 98 1 55

    2- 250 3,00 1059 745 44 500,114 1084 770 45 501 98 1 55

  • 8/2/2019 Vertical Pumps 50hz

    13/36

    (E) 2-10-0,37kW

    (E) 2-20-0,37kW

    (E) 2-30-0,37kW

    (E) 2-40-0,55kW

    (E) 2-50-0,55kW

    (E) 2-60-0,75kW

    2-70-0,75kW

    2-80-1,1kW

    2-90-1,1kW

    2-100-1,1kW

    2-110-1,1kW

    2-130-1,5kW

    2-150-1,5kW

    2-160-2,2kW

    2-180-2,2kW

    2-200-2,2kW

    2-230-3,0kW

    2-250-3,0kW

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    140

    150

    160

    170

    180

    190

    200

    210

    220

    230

    240

    250

    0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Q(l/s)

    H (m)

    Pst0.07

    0.09

    0.11

    0.13

    0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Q(l/s)

    Pst (kW)

    20

    30

    40

    50 (%)

    2

    4

    6

    8

    0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 Q(l/s)

    NPSH (m)

    0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0Q(m

    3/h)

    DPV 2

    DPVE 2Performance curveaccording to:

    DIN 2548 Class C

    50 Hz 2850 min-1

    H (m)

    1 m = 1,42 Psi

    3,28 feet

    9,806 kPa

    0,098 Bar

    Q (l/s)

    1 l/s = 15,85 US.Gpm

    13,20 Imp.Gpm

    60 l/min

    dp pumps www.dp-pumps.com 13

  • 8/2/2019 Vertical Pumps 50hz

    14/36

    DPV 4

    DPVE 4

    14

    DPVE

    Pump

    type

    DPV(S)(F)(V)(E)

    Mo

    torpower

    [kW]

    Dimens

    ions

    E1

    [mm

    ]

    Dimens

    ions

    E2

    [mm

    ]

    Shipp

    ingvo

    lume

    [m3]

    Dimens

    ions

    F1

    [mm

    ]

    Dimens

    ions

    F1

    [mm

    ]

    Dimens

    ions

    F2

    [mm

    ]

    Ne

    twe

    ight

    [kg

    ]

    Ne

    twe

    ight

    [kg

    ]

    DPVEDPV(S)(V)General

    Dimens

    ions

    F1

    [mm

    ]

    Dimens

    ions

    F2

    [mm

    ]

    Ne

    twe

    ight

    [kg

    ]

    DPV(S)F

    Grosswe

    ight

    [kg

    ]

    Grosswe

    ight

    [kg

    ]

    Grosswe

    ight

    [kg

    ]

    Dimens

    ions

    E1

    [mm

    ]

    Dimens

    ions

    E2

    [mm

    ]

    4- 10 0,37 431433 232143 93 1113 13170,042 458 257 13 15 138 110

    4- 20 0,37 431433 232143 93 1113 13170,042 458 257 13 15 138 110

    4- 30 0,55 452454 253143 93 1315 15180,042 479 278 15 17 138 110

    4- 40 0,75 512511 284160 101,5 1816 20200,042 536 309 16 18 156 120

    4- 50 0,75 533532 305160 101,5 1917 21200,042 557 330 17 19 156 120

    4- 60 1,10 554553 326160 101,5 2119 23220,049 578 351 19 21 156 120

    4- 70 1,10 574 347160 101,5 19 230,049 599 372 19 21

    4- 80 1,50 634 378174 142 25 280,049 659 403 25 27

    4- 90 1,50 655 399174 142 25 290,055 680 424 25 28

    4- 100 1,50 676 420174 142 26 290,055 701 445 26 28

    4- 110 2,20 722 441174 142 29 330,055 747 466 29 32

    4- 130 2,20 764 483174 142 30 340,069 789 508 30 33

    4- 150 2,20 806 525174 142 31 350,069 831 550 31 34

    4- 160 3,00 870 556198 155 40 450,095 895 581 42 46

    4- 180 3,00 912 598198 155 41 460,095 937 623 42 47

    4- 200 3,00 954 640198 155 42 480,114 979 665 43 48

    4- 230 4,00 1026 703224 168 49 550,114 1051 728 51 56

    4- 250 4,00 1068 745224 168 50 560,114 1093 770 52 57

  • 8/2/2019 Vertical Pumps 50hz

    15/36

    (E) 4-10-0,37kW

    (E) 4-20-0,37kW

    (E) 4-30-0,55kW

    (E) 4-40-0,75kW

    (E) 4-50-0,75kW

    (E) 4-60-1,1kW

    4-70-1,1kW

    4-80-1,5kW

    4-90-1,5kW

    4-100-1,5kW

    4-110-2,2kW

    4-130-2,2kW

    4-150-2,2kW

    4-160-3,0kW

    4-180-3,0kW

    4-200-3,0kW

    4-230-4,0kW

    4-250-4,0kW

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    140

    150

    160

    170

    180

    190

    200

    210

    220

    230

    240

    250

    0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 Q(l/s)

    H (m)

    Pst0.12

    0.14

    0.16

    0.18

    0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 Q(l/s)

    Pst (kW)

    10

    30

    50

    70 (%)

    0

    2

    46

    8

    0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 Q(l/s)

    NPSH (m)

    0 1 2 3 4 5 6 7 8 Q(m3/h)

    DPV 4

    DPVE 4Performance curveaccording to:

    DIN 2548 Class C

    50 Hz 2850 min-1

    H (m)

    1 m = 1,42 Psi

    3,28 feet

    9,806 kPa

    0,098 Bar

    Q (l/s)

    1 l/s = 15,85 US.Gpm

    13,20 Imp.Gpm

    60 l/min

    dp pumps www.dp-pumps.com15

  • 8/2/2019 Vertical Pumps 50hz

    16/36

    DPV 10

    16

  • 8/2/2019 Vertical Pumps 50hz

    17/36

    10-10-0,75kW

    10-20-0,75kW

    10-30-1,1kW

    10-40-1,5kW

    10-50-2,2kW

    10-60-2,2kW

    10-70-3,0kW

    10-80-3,0kW

    10-90-4,0kW

    10-100-4,0kW

    10-120-5,5kW

    10-140-5,5kW

    10-160-5,5kW

    10-180-7,5kW

    10-200-7,5kW

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    140

    150

    160

    170

    180

    190

    200

    210

    220

    230

    240

    250

    0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 Q(l/s)

    H (m)

    Pst0.2

    0.3

    0.4

    0.5

    0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 Q(l/s)

    Pst (kW)

    10

    30

    50

    70 (%)

    0

    1

    2

    3

    0.0 0.3 0.6 0.9 1.2 1.5 1.8 2.1 2.4 2.7 3.0 3.3 Q(l/s)

    NPSH (m)

    0 1 2 3 4 5 6 7 8 9 10 11 12 Q(m3/h)

    DPV 10

    Performance curve

    according to:

    DIN 2548 Class C

    50 Hz 2850 min-1

    dp pumps www.dp-pumps.com

    H (m)

    1 m = 1,42 Psi

    3,28 feet

    9,806 kPa

    0,098 Bar

    Q (l/s)

    1 l/s = 15,85 US.Gpm

    13,20 Imp.Gpm

    60 l/min

    17

  • 8/2/2019 Vertical Pumps 50hz

    18/36

    DPV 14

    18

  • 8/2/2019 Vertical Pumps 50hz

    19/36

  • 8/2/2019 Vertical Pumps 50hz

    20/36

    DPV 18

    20

  • 8/2/2019 Vertical Pumps 50hz

    21/36

    DPV 18

    Performance curve

    according to:

    DIN 2548 Class C

    50 Hz 2850 min-1

    H (m)

    1 m = 1,42 Psi

    3,28 feet

    9,806 kPa

    0,098 Bar

    Q (l/s)

    1 l/s = 15,85 US.Gpm

    13,20 Imp.Gpm

    60 l/min

    dp pumps www.dp-pumps.com21

  • 8/2/2019 Vertical Pumps 50hz

    22/36

    DPVF 24

    22

  • 8/2/2019 Vertical Pumps 50hz

    23/36

    DPVF 24

    Performance curve

    according to:

    DIN 2548 Class C

    50 Hz 1425 min-1

    H (m)

    1 m = 1,42 Psi

    3,28 feet

    9,806 kPa

    0,098 Bar

    Q (l/s)

    1 l/s = 15,85 US.Gpm

    13,20 Imp.Gpm

    60 l/min

    dp pumps www.dp-pumps.com23

  • 8/2/2019 Vertical Pumps 50hz

    24/36

    DPVF 32

    24

  • 8/2/2019 Vertical Pumps 50hz

    25/36

    DPVF 32

    Performance curve

    according to:

    DIN 2548 Class C

    50 Hz 2850 min-1

    dp pumps www.dp-pumps.com25

    32-10-2,2kW

    32-20-4,0kW

    32-30-5,5kW

    32-40-7,5kW

    32-50-11,0kW

    32-60-11,0kW

    32-70-15,0kW

    32-80-15,0kW

    32-90-15,0kW

    32-100-18,5kW

    32-110-18,5kW

    32-120-22,0kW

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    140

    150

    160

    170

    180

    190

    200

    210

    220

    230

    240

    250

    0 1 2 3 4 5 6 7 8 9 10 11 Q(l/s)

    H (m)

    Pst0.0

    1.5

    3.0

    4.5

    0 1 2 3 4 5 6 7 8 9 10 11 Q(l/s)

    Pst (kW)

    20

    40

    60

    80 (%)

    0

    2

    4

    6

    0 1 2 3 4 5 6 7 8 9 10 11 Q(l/s)

    NPSH (m)

    0 4 8 12 16 20 24 28 32 36 Q(m3/h)

    H (m)

    1 m = 1,42 Psi

    3,28 feet

    9,806 kPa

    0,098 Bar

    Q (l/s)

    1 l/s = 15,85 US.Gpm

    13,20 Imp.Gpm

    60 l/min

  • 8/2/2019 Vertical Pumps 50hz

    26/36

    DPVF 45

    26

  • 8/2/2019 Vertical Pumps 50hz

    27/36

    45-10-1-2,2kW

    45-10-4,0kW

    45-20-1-5,5kW

    45-20-7,5kW

    45-30-1-11,0kW

    45-30-11,0kW

    45-40-1-11,0kW

    45-40-15,0kW

    45-50-1-15,0kW

    45-50-18,5kW

    45-60-1-18,5kW

    45-60-22,0kW

    45-70-1-22,0kW

    45-70-30,0kW

    45-80-1-30,0kW

    45-80-30,0kW

    45-90-1-30,0kW

    45-90-37,0kW

    45-100-1-37,0kW

    45-100-37,0kW

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    140

    150

    160

    170

    180

    190

    200

    210

    220

    230

    240

    250

    260

    0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q(l/s)

    H (m)

    Pst 1/1

    Pst 1/20

    2

    4

    6

    0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q(l/s)

    Pst (kW)

    20

    40

    60

    80 (%)

    0

    3

    6

    9

    0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q(l/s)

    NPSH (m)

    0 6 12 18 24 30 36 42 48 54 Q(m3/h)

    DPVF 45

    Performance curve

    according to:

    DIN 2548 Class C

    50 Hz 2850 min-1

    H (m)

    1 m = 1,42 Psi

    3,28 feet

    9,806 kPa

    0,098 Bar

    Q (l/s)

    1 l/s = 15,85 US.Gpm

    13,20 Imp.Gpm

    60 l/min

    dp pumps www.dp-pumps.com27

  • 8/2/2019 Vertical Pumps 50hz

    28/36

    DPVF 65

    28

  • 8/2/2019 Vertical Pumps 50hz

    29/36

    65-10-3,0kW

    65-20-5,5kW

    65-30-7,5kW

    65-40-11,0kW

    65-50-15,0kW

    65-60-15,0kW

    65-70-18,5kW

    65-80-22,0kW

    65-90-22,0kW

    0

    10

    20

    30

    40

    50

    60

    70

    80

    90

    100

    110

    120

    130

    140

    150

    160

    170

    0.0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 18.0 19.5 21.0 Q(l/s)

    H (m)

    Pst1.5

    3.0

    4.5

    6.0

    0.0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 18.0 19.5 21.0 Q(l/s)

    Pst (kW)

    20

    40

    60

    80 (%)

    0.0

    2.5

    5.0

    7.5

    0.0 1.5 3.0 4.5 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 18.0 19.5 21.0 Q(l/s)

    NPSH (m)

    0 10 20 30 40 50 60 70 Q(m3/h)

    DPVF 65

    Performance curve

    according to:

    DIN 2548 Class C

    50 Hz 2850 min-1

    H (m)

    1 m = 1,42 Psi

    3,28 feet

    9,806 kPa

    0,098 Bar

    Q (l/s)

    1 l/s = 15,85 US.Gpm

    13,20 Imp.Gpm

    60 l/min

    dp pumps www.dp-pumps.com29

  • 8/2/2019 Vertical Pumps 50hz

    30/36

    DPLHS 6

    30

  • 8/2/2019 Vertical Pumps 50hz

    31/36

    DPLHS 6

    Performance curve

    according to:

    DIN 2548 Class C

    50 Hz 2850 min-1

    H (m)

    1 m = 1,42 Psi

    3,28 feet

    9,806 kPa

    0,098 Bar

    Q (l/s)

    1 l/s = 15,85 US.Gpm

    13,20 Imp.Gpm

    60 l/min

    dp pumps www.dp-pumps.com31

  • 8/2/2019 Vertical Pumps 50hz

    32/36

    NOTES

    32

  • 8/2/2019 Vertical Pumps 50hz

    33/36

    NOTES

    dp pumps www.dp-pumps.com33

  • 8/2/2019 Vertical Pumps 50hz

    34/36

    NOTES

    dp-pumps reserves the right to

    make modifications

    without prior notice.

    All specifications could besubject to change.

    dp-pumps reserves the right to

    make modifications

    without prior notice.

    All specifications could be

    subject to change.

    34

  • 8/2/2019 Vertical Pumps 50hz

    35/36

    NOTES

    dp pumps www.dp-pumps.com35

  • 8/2/2019 Vertical Pumps 50hz

    36/36

    dp pumps

    dp pumps

    P.O. Box 282400 AAAlphen aan den Rijn

    Holland

    t +31 172 48 83 25

    f+31 172 46 89 30

    [email protected]

    www.dp-pumps.com