Vertex Innovative Apparels Ltd....
Transcript of Vertex Innovative Apparels Ltd....
Vert
ex In
no
vati
ve A
pp
are
ls L
td.
(10524)
Fork
an
Tow
er,
360/A
, B
itak
Bazar,
Sagorika,
Pahart
oli
Thana,
Chitta
gong
15.M
AR
CH
.2014
Cli
en
t S
um
ma
ry R
ep
ort
Ob
se
rva
tio
ns &
Actio
ns
Wri
tte
n B
y A
lex N
ott
–1
5.0
3.1
4
Re
vie
we
d B
y M
arc
Ta
rdif –
15
.03
.14
Ap
pro
ve
d B
y G
eo
ff M
into
–2
4.0
3.1
4
Revis
ion :
Issue 0
1
Date
: 15.0
3.2
014
AM
BE
R
Execu
tiv
e S
um
mary
On 1
5.0
3.2
014 M
r.M
arc
Tard
if (
lead)
and M
r.A
lex N
ott c
arr
ied o
ut
a v
isual str
uctu
ral surv
ey
of th
e
Vert
ex I
nnovative A
ppare
ls L
td f
acto
ry a
t th
e a
ddre
ss a
nd c
o-o
rdin
ate
s g
iven o
n the c
over
page o
f th
is r
eport
. W
e m
et w
ith M
r.M
d.
Jam
al U
ddin
(M
anagin
g D
irecto
r).
We w
ere
pro
vid
ed w
ith c
opie
s o
f A
rchitectu
ral and E
ngin
eering D
esig
n d
raw
ings,
as w
ell
as a
G
eote
chin
calR
eport
. E
ngin
eering d
raw
ings w
ere
title
d P
roposed 6
–S
toried I
ndustr
ial B
uild
ing,
while
arc
hitectu
ral dra
win
gs w
ere
for
perm
it a
nd d
ispla
yed s
tam
ps a
nd s
ignatu
res f
rom
local
Bangla
deshi build
ing a
uth
orities.
The a
rchitectu
ral desig
ner
was M
r.H
aznat
Farz
an.
The
Geote
chnic
al re
port
was c
onducte
d b
y D
aw
ood
Alv
ee
Constr
uction &
Soilt
est
Lab.
The c
onstr
uction
docum
ents
indic
ate
the c
om
mencem
ent
of constr
uction in A
pril 2011.
These d
raw
ings c
losely
m
atc
hed t
he a
ctu
al site c
onditio
ns.
How
ever,
the b
uild
ing is s
till
under
constr
uction a
nd c
urr
ently
the 5
thsto
rey
floor
sla
b is in the p
rocess o
f fo
rmin
g a
nd b
ein
g p
oure
d.
The facto
ry i
s u
sed f
or
garm
ent
manufa
ctu
ring o
n a
ll sto
ries.
We in
specte
d a
ll sto
ries ,
in o
rder
to look for
conditio
ns p
osin
g im
min
ent danger
to o
ccupants
, as
well
as c
onditio
ns w
hic
h m
ight w
arr
ant
futu
re c
oncern
.
We h
ave c
on
cern
reg
ard
ing
th
e s
oil b
eari
ng
cap
acit
y c
on
sid
eri
ng
th
e f
oo
tin
g s
ize s
ho
wn
on
str
uctu
ral
dra
win
gs.
1.
Colu
mn s
afe
ty f
acto
rs a
re low
.
2.
The b
earing c
apacity
indic
ate
d o
n t
he g
eote
chnic
al re
port
does n
ot
appear
adequate
to
support
the f
ooting loads w
hic
h w
ould
be d
evelo
ped u
pon b
uild
ing c
om
ple
tion.
3.
Str
uctu
ral dra
win
gs a
ppear
err
oneous in t
heir labelli
ng.
It is u
ncle
ar
what
rein
forc
em
ent
is inte
nded f
or
gro
und a
nd t
ypic
al floor
sla
bs.
A r
ein
forc
ed g
round f
loor
sla
b r
esults in a
low
colu
mn s
tress s
afe
ty f
acto
r.
Execu
tiv
e S
um
mary
(co
nti
nu
ed
)
It w
as r
equeste
d t
hat
it b
e n
ote
d,
the 1
stand 2
nd
floor
of
the b
uild
ing a
re o
ccupie
d b
y th
e H
.B.
Intim
ate
s L
td.
facto
ry.
This
are
a w
as inclu
ded in the s
cope o
f in
spection.
Furt
her
actions w
ith a
ssocia
ted p
riorities a
nd t
imefr
am
es a
re g
iven a
t th
e e
nd o
f th
is r
eport
. P
lease
note
that
these a
ctions s
hould
be c
om
ple
ted a
s s
oon a
s p
ossib
le a
nd c
ert
ain
ly w
ithin
the t
imefr
am
e
note
d.
We h
ave r
evie
wed t
he p
ropert
y fr
om
an o
utlin
e s
eis
mic
pers
pective a
nd w
ould
consid
er
that
the
build
ing a
long w
ith m
any
oth
ers
in the D
haka r
egio
n h
ave a
ris
k in a
majo
r S
eis
mic
event.
We h
ave c
arr
ied o
ut som
e o
n-s
ite t
esting a
nd p
relim
inary
analy
sis
to s
upport
the fin
din
gs o
f th
is
report
.O
ur
Lim
itations a
nd A
ssum
ptions a
re a
lso n
ote
d a
t th
e e
nd o
f th
is r
eport
.
This
short
report
has 4
sections n
am
ely
:
1.
Executive S
um
mary
(th
is s
ection)
2.
Short
Gra
phic
al S
ection s
how
ing k
ey
issues o
bserv
ed
3.
Priority
Action L
ist
4.
Lim
itations a
nd A
ssum
ptions
5th
Sto
rey S
lab C
urr
ently
Under
Constr
uction
Bu
ild
ing
Ex
ten
ts (
On
go
ing
Co
ns
tru
cti
on
)
Bu
ild
ing
Layo
ut
Pla
ns
Gro
un
d, R
oo
f &
Typ
ical
Flo
or
Pla
ns,
Bu
ild
ing
Secti
on
s &
Ele
vati
on
s
Co
ns
tru
cti
on
Do
cu
me
nts
Str
uctu
ral P
lan
sB
eam
Rein
forc
em
en
t S
ch
ed
ule
Co
ns
tru
cti
on
Do
cu
me
nts
Beam
Rein
forc
em
en
t D
eta
il
Str
uctu
ral P
lan
s
Co
lum
n R
ein
forc
ing
Pla
cem
en
t D
eta
ils
Co
ns
tru
cti
on
Do
cu
me
nts
Co
lum
n R
ein
forc
em
en
t S
ch
ed
ule
Geo
tech
nic
al In
vesti
gati
on
Rep
ort
Co
ver
Pag
e
Co
ns
tru
cti
on
Do
cu
me
nts
Fin
din
gs S
um
mary
Bu
ild
ing
Ex
ten
ts
R.C
Beam
and c
olu
mn
fram
e w
ith a
2-w
ay
solid
sla
b
Sta
bili
ty p
rovid
ed b
y
mom
ent fr
am
e a
ction a
nd
brick in-f
ill w
alls
Sla
b T
hic
kness: 140m
m
Colu
mn S
ize:
Varies
Betw
een 3
04m
m x
304m
m
to 3
04m
m x
762m
m
Grid 6
.4m
x 6
.4m
----
---
Mo
vem
en
t Jo
int
(No
Mo
vem
en
t Jo
int)
Colu
mn L
ayout
Pla
n (
Gro
und t
o 5
thS
tories)
Priority
1 C
oncern
Colu
mn load r
un-d
ow
ns indic
ate
low
er
than d
esirable
colu
mn s
afe
ty f
acto
rs.
Lo
w C
olu
mn
Sa
fety
Fa
cto
rs
Ide
nti
fie
d P
rio
rity
2 C
on
ce
rns
So
il C
ap
ac
ity/F
oo
tin
g D
es
ign
& I
nc
om
ple
te S
tru
ctu
ral D
raw
ing
s
Priority
2 C
oncern
Foundations a
re b
uilt
in a
manner
oth
er
than t
hat
recom
mended b
y
the g
eote
chnic
al re
port
. G
enera
l fo
undation c
apacity
checks w
ere
perf
orm
ed.
Based u
pon G
eote
chnic
al findin
gs,
the s
oil
bearing
capacity
does n
ot
appear
adequate
to s
upport
the f
oundation s
how
n
on t
he s
tructu
ral dra
win
gs.
So
il C
ap
ac
ity/F
oo
tin
g D
es
ign
Priority
2 C
oncern
Str
uctu
ral dra
win
gs a
re incom
ple
te.
Typ
ical sla
b r
ein
forc
ing a
nd r
oof
sla
b r
ein
forc
ing p
lans a
re m
issin
g. T
wo d
iffe
ring g
round f
loor
sla
b
pla
ns a
re p
resente
d.
Pla
ns a
re g
enera
lly o
f very
poor
qualit
y.
Inc
om
ple
te S
tru
ctu
ral D
raw
ing
s
Pro
ble
ms O
bserv
ed
Su
mm
ary
ITE
M 1
: (P
rio
rity
1)
Co
lum
n lo
ad
ru
n-d
ow
ns
in
dic
ate
a lo
w c
olu
mn
sa
fety
fa
cto
r fo
r th
e c
om
ple
ted
bu
ild
ing
. It
is
no
tab
le t
ha
t th
e b
uil
din
g is
c
urr
en
tly u
nd
er
co
ns
tru
cti
on
at
the
5th
flo
or
sla
b le
ve
l.
ITE
M 2
:(P
rio
rity
2)
It w
as
no
ted
th
at
the
fo
un
da
tio
ns
sh
ow
n o
n
str
uc
tura
l d
raw
ing
s d
o n
ot
ma
tch
th
e r
ec
om
me
nd
ati
on
s m
ad
e b
y t
he
G
eo
tec
hn
ica
l re
po
t. A
fte
r e
xa
min
ati
on
of
Ge
ote
ch
nic
al fi
nd
ing
s a
nd
va
rio
us
fo
un
da
tio
n c
he
ck
s b
as
ed
up
on
th
e f
ou
nd
ati
on
s in
dic
ate
d b
y t
he
s
tru
ctu
ral d
raw
ing
s. It
is
do
ub
tfu
l th
at
the
so
il b
ea
rin
g c
ap
ac
ity i
s
ad
eq
ua
te t
o s
up
po
rt t
he
lo
ad
s a
pp
lie
d t
o t
he
fo
oti
ng
s p
res
en
ted
. N
ota
bly
, b
am
bo
o p
ile
s w
ere
us
ed
be
ne
ath
pa
d f
oo
tin
gs
. H
ow
eve
r, t
he
y
co
mm
en
ce
ap
pro
xim
ate
ly 2
fe
et
be
ne
ath
th
e u
nd
ers
ide
of
foo
tin
g a
nd
o
nly
ex
ten
d t
o a
de
pth
of
28
’-8
” b
elo
w g
rad
e w
he
re s
oil
is
of
ve
ry p
oo
r c
ap
ac
ity.
ITE
M 3
:(P
rio
rity
2)
Str
uc
tura
l d
raw
ing
s w
ere
fo
un
d t
o b
e i
nc
on
sis
ten
t a
nd
of
low
qu
ali
ty.
It i
s q
ue
sti
on
ab
le h
ow
th
e f
ull
str
uc
ture
ha
s b
ee
n
bu
ilt
wh
ile
la
ck
ing
cle
ar
co
nc
ise
str
uc
tura
l d
raw
ing
s. A
s a
n e
xa
mp
le,
the
re is
no
typ
ica
l fl
oo
r s
lab
re
info
rcin
g p
lan
pro
vid
ed
. H
ow
eve
r, t
he
s
tru
ctu
re is
cu
rre
ntl
y u
nd
er
co
ns
tru
cti
on
at
the
5th
sto
rey l
eve
l.
Pri
ori
ty 1
(Im
me
dia
te –
No
w)
•D
o n
ot co
ntin
ue
co
nstr
uction
pa
st th
e 5
thflo
or
sla
b le
ve
l. It
is r
eco
mm
en
ded
th
at th
e 5
thflo
or
sla
b b
e u
se
d a
s th
e r
oo
f le
ve
l.
Item
1 a
nd
Acti
on
s
Colu
mn w
ork
ing s
tress w
ill b
e h
igher
than a
ccepta
ble
upon b
uild
ing c
om
ple
tion a
nd is s
till
of
concern
at
the c
urr
ent
exte
nt
of constr
uction.
Pri
ori
ty 2
(wit
hin
6 w
ee
ks
)
•F
acto
ry e
ng
ine
er
to r
evie
w d
esig
n, lo
ad
s a
nd
co
lum
n s
tre
sse
s.
Pri
ori
ty 3
(wit
hin
6 m
on
ths
)
•P
rod
uce
an
d a
ctive
ly m
an
ag
e a
lo
ad
ing
pla
n
for
all
flo
or
pla
tes g
ivin
g c
on
sid
era
tio
n to
sla
b
an
d c
olu
mn
ca
pa
city.
Pri
ori
ty 1
(Im
me
dia
te –
No
w)
•N
on
e
Item
2 a
nd
Acti
on
s
Foundation d
esig
n is q
uestionable
giv
en e
xis
ting s
oil
pro
pert
ies.
Pri
ori
ty 2
(wit
hin
6 w
ee
ks
)
•D
eta
iled
en
gin
ee
rin
g a
sse
ssm
en
t to
be
co
nd
ucte
d in
ord
er
to d
ete
rmin
e th
e
ad
eq
ua
cy o
f th
e a
s-b
uilt
fo
un
da
tio
n fo
r
exis
tin
g s
oil
pro
pe
rtie
s
Pri
ori
ty 3
(wit
hin
6 m
on
ths
)
•C
arr
y o
ut a
ny r
em
ed
ial m
ea
su
res
reco
mm
en
de
d b
y a
bo
ve
me
ntio
ne
d d
eta
iled
en
gin
ee
rin
g a
sse
ssm
en
t.
Pri
ori
ty 1
(Im
me
dia
te –
No
w)
•N
on
e
Item
3 a
nd
Acti
on
sS
tructu
ral dra
win
gs a
re inconsis
tent
and n
on-u
niform
. C
ritical build
ing e
lem
ents
have b
een
constr
ucte
d w
ithout
pro
per
pla
ns.
Pri
ori
ty 2
(wit
hin
6 w
ee
ks
)
•D
eta
iled
en
gin
ee
rin
g a
sse
ssm
en
t to
be
ca
rrie
d o
ut in
ord
er
to a
de
qu
ate
ly fo
rmu
late
str
uctu
ral p
lan
s a
nd
asse
ss th
e s
uita
bili
ty o
f
as-b
uilt
str
uctu
ral e
lem
en
ts
Pri
ori
ty 3
(wit
hin
6 m
on
ths
)
•A
dd
ress fin
din
gs a
nd
re
co
mm
en
datio
ns o
f
the
ab
ove
me
ntio
ne
d d
eta
iled
en
gin
ee
rin
g
asse
ssm
ent
Deta
il E
ng
ineeri
ng
Assessm
en
t
This
Schedule
develo
ps
a m
inim
um
level o
f in
form
ation, a
naly
sis
and t
est
ing e
xpecte
d a
s part
of a D
eta
il E
ngin
eeri
ng A
ssess
ment.
The
build
ing(s
) have b
een v
isually
ass
ess
ed a
nd it m
ay b
e d
eem
ed n
ecess
ary
that a d
eta
iled e
ngin
eeri
ng a
ssess
ment
be c
arr
ied o
ut by a
com
pete
nt E
ngin
eeri
ng T
eam
em
plo
yed b
y the f
acto
ry O
wner.
This
request
should
be r
ead in c
onju
nction w
ith the B
UE
T d
evelo
ped T
ripart
ite G
uid
elin
e d
ocum
ent fo
r A
ssess
ment
of S
tructu
ralI
nte
gri
ty o
f E
xis
ting R
MG
Facto
ry B
uild
ings
in B
angla
desh
(T
ripart
ite D
ocum
ent)
, th
e late
st v
ers
ion o
f th
is d
ocum
ent sh
ould
be r
efe
renced.
This
docum
ent als
o g
ives
guid
ance o
n r
equir
ed c
om
pete
ncy o
f E
ngin
eeri
ng T
eam
.
We e
xpect th
at th
e follo
win
g m
ay n
eed to b
e c
arr
ied o
ut:
1.
Develo
pm
ent o
f F
ull
Engin
eeri
ng A
s-B
uilt
Dra
win
gs
show
ing S
tructu
re, lo
adin
g, ele
ments
, dim
ensi
ons,
levels
, fo
undations
and f
ram
ing
on P
lan, S
ection a
nd E
levational d
raw
ings.
2.
The E
ngin
eeri
ng team
are
to c
arr
y o
ut su
pport
ing c
alc
ula
tions
with a
model b
ase
d d
esi
gn c
heck to a
ssess
the s
afe
ty a
nd s
erv
iceabili
ty
of th
e b
uild
ing a
gain
st loadin
g a
s se
t out in
BN
BC
-2006, Low
er
rate
pro
vis
ions
can b
e a
pplie
d in
accord
ance w
ith t
he T
ripart
ite
Guid
ance follo
win
g in
tern
ational e
ngin
eeri
ng p
ractice, ju
stific
ation for
these
low
er
rate
pro
vis
ions
must
be m
ade.
3.
A G
eote
chnic
al R
eport
desc
ribin
g g
round c
onditio
ns
and c
om
menting o
n f
oundation s
yst
em
s use
d/p
ropose
d.
4.
A r
eport
on E
ngin
eeri
ng test
s carr
ied o
ut to
just
ify m
ate
rials
str
ength
s and r
ein
forc
em
ent c
onte
nt in
all
key e
lem
ents
stu
die
d.
5.
Deta
iled lo
ad p
lans
shall
be p
repare
d f
or
each level s
how
ing c
urr
ent ad p
ote
ntial f
utu
re lo
adin
g w
ith a
ll key e
quip
ment item
ssh
ow
n
with a
ssocia
ted loads.
6.
The E
ngin
eeri
ng team
will
pre
pare
an a
ssess
ment
report
that covers
the follo
win
g:
•A
s-B
uilt
dra
win
gs
inclu
din
g•
Pla
ns
at each level c
alli
ng u
p a
nd d
imensi
onin
g a
ll st
ructu
ral com
ponents
•C
ross
sectional d
raw
ings
show
ing s
tructu
ral beam
s, s
labs,
flo
or to
flo
or heig
hts
, ro
of build
-ups
and B
asi
c d
esi
gn
info
rmatio
n o
f th
e s
tructu
re•
Hig
hlig
ht any v
ari
ations
betw
een A
s-built
com
pare
d to the d
esi
gn s
tructu
re•
Resu
lt o
f te
stin
g for
stre
ngth
and m
ate
rials
•R
esu
lts
of geote
chnic
al a
ssess
ment
and t
est
ing/invest
igation
•D
eta
ils o
f lo
adin
g, in
puts
and r
esu
lts
of com
pute
r m
odelli
ng
•C
om
menta
ry o
n a
dequate
/inadequacy o
f ele
ments
of th
e s
tructu
re•
Schedule
of any r
equir
ed r
etr
ofitt
ing requir
ed f
or
safe
ty o
r perf
orm
ance o
f S
tructu
re
Any p
roposa
ls f
or
Retr
ofittin
g to f
ollo
w g
uid
ance d
evelo
ped in
the T
ripart
ite D
ocum
ent
Su
rvey L
imit
ati
on
s a
nd
Assu
mp
tio
ns
This
report
is
for th
e p
rivate
and c
onfidential u
se o
f A
ccord
for
whom
it w
as
pre
pare
d togeth
er
with th
eir
pro
fess
ional a
dvis
ors
as
appro
pri
ate
. I
t sh
ould
not be r
epro
duced in
whole
or
in p
art
or
relie
d u
pon b
y t
hir
d p
art
ies
for
any u
se w
ithout th
e e
xpre
ss w
ritt
en p
erm
issi
on
of W
SP
.
This
report
can b
e u
sed in d
iscuss
ion w
ith t
he s
upplie
r or
facto
ry o
wner
as
a m
eans
to r
ectify
or
addre
ss a
ny o
bse
rvations
made.
The r
eport
is
not com
pre
hensi
ve a
nd is
limited to w
hat
could
be o
bse
rved d
uri
ng a
vis
ual i
nsp
ection o
f th
e b
uild
ing.
This
report
is
not in
tended to b
e tre
ate
d a
s a g
enera
lised in
spection a
nd d
oes
not cover th
e d
ete
riora
tion o
f st
ructu
ral m
em
bers
thro
ugh
dam
pness
, fu
ngal o
r in
sect att
ack, nor
does
it d
eal w
ith p
roble
ms
and d
efe
cts
of non-s
tructu
ral natu
re. O
ther non s
tructu
ral asp
ects
of th
e
build
ing s
uch a
s fire
safe
ty h
ave n
ot been a
ssess
ed i
n this
surv
ey.
Except as
oth
erw
ise n
ote
d, dra
ins
and o
ther
serv
ices
were
not vie
wed o
r te
sted d
uri
ng o
ur
insp
ection a
nd a
re t
here
fore
sim
ilarl
yexclu
ded
from
this
report
. W
e h
ave n
ot in
specte
d a
ny p
art
s of th
e s
tructu
re w
hic
h a
re c
overe
d, u
nexpose
d o
r in
access
ible
and w
e a
re there
fore
unable
to r
eport
that any s
uch p
art
of th
e p
ropert
y is
fre
e fro
m d
efe
ct.
Exte
rnal i
nsp
ection o
f th
e f
açade w
alls
has
genera
lly b
een c
arr
ied o
ut fr
om
gro
und level o
nly
by v
isual s
ighting. N
o o
penin
gup
work
s w
ere
carr
ied o
ut (e
xcept as
note
d)
and w
e r
ely
on the A
rchitects
and E
ngin
eers
dra
win
gs
pro
vid
ed to u
se f
or
our
vie
ws
on c
onceale
dpart
s of th
e
stru
ctu
re a
nd in p
art
icula
r fo
undations.
S
trength
s of m
ate
rials
and c
om
ponents
are
unte
sted a
nd w
e r
ecom
mend that th
e facto
ry o
wners
B
uild
ing E
ngin
eer
carr
ies
out in
situ
test
ing o
ver and a
bove those
suggest
ed t
o s
atisf
y them
selv
es
with t
he m
ate
rial s
trength
sand c
om
ponent
deta
ils.
Recom
mendations,
where
giv
en, a
re f
or
the p
urp
ose
of pro
vid
ing in
dic
ative a
dvic
e o
nly
, are
not exhaust
ive, r
ela
te s
ole
ly to identify
ing key
and o
bvio
us
stru
ctu
ral defe
cts
as
identified in
this
pre
senta
tion, and d
o n
ot ta
ke the f
orm
of or
const
itute
a s
pecific
ation for
work
s.
We take
no r
esp
onsi
bili
ty for
the w
ork
s as
const
ructe
d. T
his
report
does
not in
terf
ere
with the f
acto
ry o
wners
Build
ing E
ngin
eers
resp
onsi
bili
ty for
the
stru
ctu
ral p
erf
orm
ance o
f th
is b
uild
ing. T
he B
uild
ing E
ngin
eer
rem
ain
s fu
lly resp
onsi
ble
for th
e s
tructu
ral a
dequacy o
f th
e b
uild
ing.
This
report
does
not com
ment i
n d
eta
il on the f
utu
re s
eis
mic
perf
orm
ance o
f th
e b
uild
ing a
nd o
nly
hig
hlig
hts
the f
act th
at th
e b
uild
ing m
ay
experi
ence s
ignific
ant d
am
age o
r colla
pse
in a
seis
mic
event alo
ng w
ith m
any o
thers
in the D
haka r
egio
n.
The o
bse
rvations
in this
report
are
base
d o
n the E
ngin
eeri
ng J
udgem
ent of th
e lead s
urv
eyor/
engin
eer at th
e tim
e o
f th
e s
urv
ey.
We a
ssum
e
in m
akin
g these
obse
rvations
that no c
overi
ng u
p o
f fa
ults
defe
cts
, filli
ng o
r pla
steri
ng o
ver cra
ckin
g o
r si
gnific
ant r
epair
work
has
been
carr
ied o
ut by t
he b
uild
ing o
wner.
A
ny f
utu
re a
ltera
tions
or
additio
nal w
ork
by the b
uild
ing o
wner
will
void
this
report
.