Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North...

20
Ventura Lighting (Europe) - 1000 North Circular Road, London NW2 7JP Web: www.venturalighting.co.uk Tel: +44 (0)20 8208 4081 COLUMNS & POLES Technical Datasheets Ventura The Structural Steel Division Of LED Evolution

Transcript of Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North...

Page 1: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

Ventura Lighting (Europe) - 1000 North Circular Road, London NW2 7JPWeb: www.venturalighting.co.uk Tel: +44 (0)20 8208 4081

COLUMNS & POLESTechnical Datasheets

VenturaThe Structural Steel Division Of LED Evolution

Page 2: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale 1:1

ROOT MOUNTED LIGHT DUTY

BRIT-R-LD Edition A Sheet 1/1

ROOT MOUNTED LIGHT DUTY

STEEL POLE - ROOT MOUNTED - TUBULAR - LIGHT DUTY - REMOVABLE ARM

Serial No

Model No

Height Bot. Dia

Bot. Height

Length Planted

Top Dia

Top Length

Door Opening

Door loc. above GL

Spigot Dia x Length

G I A F J E C x D B L x K

(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)

BRIT-01 SRTLR040 4000 139.7 1250 800 76.1 2750 500x100 600 Nil

BRIT-02 SRTLR050 5000 139.7 1250 850 76.1 3750 500x100 600 Nil

BRIT-03 SRTLR060 6000 139.7 1250 1000 76.1 4750 500x100 600 Nil

BRIT-04 SRTLR070 7000 168.3 1400 1200 88.9 5600 600x115 650 76.1x200

BRIT-05 SRTLR080 8000 168.3 1400 1350 88.9 6600 600x115 650 76.1x200

BRIT-06 SRTLR090 9000 168.3 1600 1500 114.3 7400 600x115 850 101.6x250

BRIT-07 SRTLR010 10000 168.3 1600 1700 114.3 8400 600x115 850 101.6x250

BRIT-08 SRTLR011 11000 193.7 1750 1850 139.7 9250 600x115 1000 127x300

BRIT-09 SRTLR012 12000 193.7 1750 2000 139.7 10250 600x115 1000 127x300

VenturaThe Structural Steel Division Of LED Evolution

Page 3: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale 1:1

ROOT MOUNTED MEDIUM DUTY

BRIT-R-MD Edition A Sheet 1/1

STEEL POLE - ROOT MOUNTED - TUBULAR - MEDIUM DUTY - REMOVABLE ARM

Serial No

Model No

Height Bot. Dia

Bot. Height

Length Planted

Top Dia

Top Length

Door Opening

Door loc. above GL

Spigot Dia x Length

G I A F J E C x D1 B L x K

(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)

BRIT-19 SRTMR040 4000 168.3 1250 800 76.1 2750 600x115 600 Nil

BRIT-20 SRTMR050 5000 168.3 1250 850 76.1 3750 600x115 600 Nil

BRIT-21 SRTMR060 6000 168.3 1250 1000 88.9 4750 600x115 600 76.1x200

BRIT-22 SRTMR070 7000 168.3 1400 1200 114.3 5600 600x115 650 101.6x250

BRIT-23 SRTMR080 8000 168.3 1400 1350 114.3 6600 600x115 650 101.6x250

BRIT-24 SRTMR090 9000 168.3 1600 1500 139.7 7400 600x115 850 127x300

BRIT-25 SRTMR010 10000 168.3 1600 1700 139.7 8400 600x115 850 127x300

BRIT-26 SRTMR011 11000 193.7 1750 1850 168.3 9250 600x115 1000 139.7x300

BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300

ROOT MOUNTED MEDIUM DUTY

VenturaThe Structural Steel Division Of LED Evolution

Page 4: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale 1:1

ROOT MOUNTED HEAVY DUTY

BRIT-R-HD Edition A Sheet 1/1

STEEL POLE - ROOT MOUNTED - TUBULAR - HEAVY DUTY - REMOVABLE ARM

Serial No

Model No

Height Bot. Dia

Bot. Height

Length Planted

Top Dia

Top Length

Door Opening

Door loc. above GL

Spigot Dia x Length

G I A F J E C x D B L x K

(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)

BRIT-37 SRTHR040 4000 168.3 1250 800 114.3 2750 600x115 600 101.6x250

BRIT-38 SRTHR050 5000 168.3 1250 1000 114.3 3750 600x115 600 101.6x250

BRIT-39 SRTHR060 6000 168.3 1250 1200 114.3 4750 600x115 600 101.6x250

BRIT-40 SRTHR070 7000 193.7 1400 1400 114.3 5600 600x115 650 101.6x250

BRIT-41 SRTHR080 8000 193.7 1400 1600 114.3 6600 600x115 650 101.6x250

BRIT-42 SRTHR090 9000 193.7 1600 1800 139.7 7400 600x115 850 127x300

BRIT-43 SRTHR010 10000 193.7 1600 2000 139.7 8400 600x115 850 127x300

BRIT-44 SRTHR011 11000 219.1 1750 2200 168.3 9250 600x115 1000 139.7x300

BRIT-45 SRTHR012 12000 219.1 1750 2400 168.3 10250 600x115 1000 139.7x300

ROOT MOUNTED HEAVY DUTY

VenturaThe Structural Steel Division Of LED Evolution

Page 5: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale 1:1

BASE PLATE MOUNTED LIGHT DUTY

BRIT-B-LD Edition A Sheet 1/1

STEEL POLE - BASE PLATE MOUNTED - TUBULAR - LIGHT DUTY - REMOVABLE ARM

Serial No

Model No

Height Bot. Dia

Bot. Height

Bot. Thk.

Base Plate Top Dia

Top Thk.

Top Length

Door Opening

Door loc. above GL

Z O Y S x S x T R X U x V W

(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)

BRIT-10 SBTLR040 4000 139.7 1250 4.5 280x280x12 76.1 3.2 2750 500x100 600

BRIT-11 SBTLR050 5000 139.7 1250 4.5 280x280x12 76.1 3.2 3750 500x100 600

BRIT-12 SBTLR060 6000 139.7 1250 4.5 280x280x12 76.1 3.2 4750 500x100 600

BRIT-13 SBTLR070 7000 168.3 1400 4.5 290x290x16 88.9 3.2 5600 600x115 650

BRIT-14 SBTLR080 8000 168.3 1400 4.5 290x290x16 88.9 3.2 6600 600x115 650

BRIT-15 SBTLR090 9000 168.3 1600 4.5 400x400x25 114.3 3.6 7400 600x115 850

BRIT-16 SBTLR010 10000 168.3 1600 4.5 400x400x25 114.3 3.6 8400 600x115 850

BRIT-17 SBTLR011 11000 193.7 1750 4.8 400x400x25 139.7 4.5 9250 600x115 1000

BRIT-18 SBTLR012 12000 193.7 1750 4.8 400x400x25 139.7 4.5 10250 600x115 1000

BASE PLATE MOUNTED LIGHT DUTY

VenturaThe Structural Steel Division Of LED Evolution

Page 6: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale 1:1

BASE PLATE MOUNTED MEDIUM DUTY

BRIT-B-MD Edition A Sheet 1/1

STEEL POLE - BASE PLATE MOUNTED - TUBULAR - MEDIUM DUTY - REMOVABLE ARM

Serial No

Model No

Height Bot. Dia

Bot. Height

Bot. Thk.

Base Plate Top Dia

Top Thk.

Top Length

Door Opening

Door loc. above GL

Z O Y S x S x T R X U x V W

(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)

BRIT-28 SBTMR040 4000 168.3 1250 4.5 290x290x16 76.1 3.2 2750 600x115 600

BRIT-29 SBTMR050 5000 168.3 1250 4.5 290x290x16 76.1 3.2 3750 600x115 600

BRIT-30 SBTMR060 6000 168.3 1250 4.5 290x290x16 88.9 3.2 4750 600x115 600

BRIT-31 SBTMR070 7000 168.3 1400 4.5 400x400x25 114.3 3.6 5600 600x115 650

BRIT-32 SBTMR080 8000 168.3 1400 4.5 400x400x25 114.3 3.6 6600 600x115 650

BRIT-33 SBTMR090 9000 168.3 1600 4.5 400x400x25 139.7 4.5 7400 600x115 850

BRIT-34 SBTMR010 10000 168.3 1600 4.5 400x400x25 139.7 4.5 8400 600x115 850

BRIT-35 SBTMR011 11000 193.7 1750 4.5 400x400x25 168.3 4.5 9250 600x115 1000

BRIT-36 SBTMR012 12000 193.7 1750 4.5 400x400x25 168.3 4.5 10250 600x115 1000

BASE PLATE MOUNTED MEDIUM DUTY

VenturaThe Structural Steel Division Of LED Evolution

Page 7: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale 1:1

BASE PLATE MOUNTED HEAVY DUTY

BRIT-B-HD Edition A Sheet 1/1

STEEL POLE - BASE PLATE MOUNTED - TUBULAR - HEAVY DUTY - REMOVABLE ARM

Serial No

Model No

Height Bot. Dia

Bot. Height

Bot. Thk.

Base Plate Top Dia

Top Thk.

Top Length

Door Opening

Door loc. above GL

Z O Y S x S x T R X U x V W

(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)

BRIT-46 SBTHR040 4000 168.3 1250 4.5 290x290x16 114.3 3.6 2750 600x115 600

BRIT-47 SBTHR050 5000 168.3 1250 4.5 290x290x16 114.3 3.6 3750 600x115 600

BRIT-48 SBTHR060 6000 168.3 1250 4.5 400x400x25 114.3 3.6 4750 600x115 600

BRIT-49 SBTHR070 7000 193.7 1400 4.5 400x400x25 114.3 3.6 5600 600x115 650

BRIT-50 SBTHR080 8000 193.7 1400 4.5 400x400x25 114.3 3.6 6600 600x115 650

BRIT-51 SBTHR090 9000 193.7 1600 4.5 400x400x25 139.7 4.5 7400 600x115 850

BRIT-52 SBTHR010 10000 193.7 1600 4.5 400x400x25 139.7 4.5 8400 600x115 850

BRIT-53 SBTHR011 11000 219.1 1750 4.8 510x510x30 168.3 4.5 9250 600x115 1000

BRIT-54 SBTHR012 12000 219.1 1750 4.8 510x510x30 168.3 4.5 10250 600x115 1000

BASE PLATE MOUNTED HEAVY DUTY

VenturaThe Structural Steel Division Of LED Evolution

Page 8: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 29/11/2014 Scale 1:1

6 METRE MID HINGED POLE

BRIT-6M-MH Edition A Sheet 1/1

APPLICABLE TOLERANCES

Height of pole <=10M ±1%

Height of pole >10M ±1.2%

Bracket projection length ±2%

Lantern fixing angle ±2°

Door opening & cable entry slot +10mm -0mm

Column circumference ±1%

Deviation in shape of circular cross section ±3%

Spigot length (vertical & angular) ±2mm

Dia. of lantern pipes EN 10210-2 Table 2 EN 10219-2 Table 2

Verticality 1°

Thickness EN 10051

Bracket & deviation ±5°

APPLICABLE STANDARDS

Design BS EN 40

Material (Steel) Column & Bracket EN 10025, EN 10149, EN 10210, EN 10219

Materials (Foundation Bolts) EN 10025 gr S 235 JR

Galvanising BS EN 1461

Protection (Door) EN 60529 - IP 3X

Impact Protection (Door) EN 50102 - IK08

Washers EN ISO 7093

Welding Process EN 1011-1, EN 1011-2

Welding Procedures EN 288-1, EN 288-2

Wind Actions EN 1991-1-4:2005 Eurocode 1 BS 6399

Inspection Documentation EN 10204

Visual Inspection (Welding) EN 571-1

6 METRE MID HINGED POLE

VenturaThe Structural Steel Division Of LED Evolution

Page 9: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 29/11/2014 Scale 1:1

TAPERED OCTAGONAL SERIES

BRIT-XX-TO Edition A Sheet 1/1

STEEL POLE - BASE PLATE MOUNTED - TAPERED - OCTAGONAL - REMOVABLE ARM

Serial No

Model No

Height Top Dia

Bot. Dia

Base Plate Anchor Bolts Door Opening

Door loc. above GL

Y P T P x P x O W x V U

(mm) (mm) (mm) (mm) (mm) (mm) (mm)

BRIT-64 SBTOR040 4000 76 130 280x280x12 M16x500 - 4 Nos 300x85 500

BRIT-65 SBTOR050 5000 76 144 280x280x12 M16x500 - 4 Nos 300x85 500

BRIT-66 SBTOR060 6000 76 158 290x290x16 M20x500 - 4 Nos 300x85 500

BRIT-67 SBTOR070 7000 76 183 400x400x25 M24x600 - 4 Nos 600x115 500

BRIT-68 SBTOR080 8000 76 183 400x400x25 M24x600 - 4 Nos 600x115 600

BRIT-69 SBTOR090 9000 76 210 400x400x25 M24x600 - 4 Nos 600x115 600

BRIT-70 SBTOR010 10000 76 210 400x400x25 M24x600 - 4 Nos 600x115 600

BRIT-71 SBTOR011 11000 76 232 400x400x25 M24x600 - 4 Nos 600x115 600

BRIT-72 SBTOR012 12000 76 232 400x400x25 M24x600 - 4 Nos 600x115 600

STEEL POLE - ROOT MOUNTED - TAPERED - OCTAGONAL - REMOVABLE ARM

Serial No

Model No

Height Top Dia

Bot. Dia

Length Planted

Door Opening

Door loc. above GL

Cable Entry Slot Position below NGL

Cable Entry Slot

Size

I A E J H x G F D C x B

(mm) (mm) (mm) (mm) (mm) (mm) (mm) (mm)

BRIT-55 SRTOR040 4000 76 130 600 300x85 500 350 150x50

BRIT-56 SRTOR050 5000 76 144 800 300x85 500 350 150x50

BRIT-57 SRTOR060 6000 76 158 1000 300x85 500 350 150x50

BRIT-58 SRTOR070 7000 76 183 1200 600x115 500 350 150x50

BRIT-59 SRTOR080 8000 76 183 1200 600x115 600 350 150x50

BRIT-60 SRTOR090 9000 76 210 1500 600x115 600 350 150x50

BRIT-61 SRTOR010 10000 76 210 1500 600x115 600 350 150x50

BRIT-62 SRTOR011 11000 76 232 1700 600x115 600 350 150x50

BRIT-63 SRTOR012 12000 76 232 1700 600x115 600 350 150x50

TAPERED OCTAGONAL SERIES

VenturaThe Structural Steel Division Of LED Evolution

Page 10: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS

15 METER MONO POLE

BRIT-15M-M Edition A Sheet 1/1

A

B

C

D

E

Door at the top of the pole to accessTo secure cables complete with cable restraining bar

Brackets to suit soll ladder and fall arrest system on 700 centres

Top of pole capped, drilled and tapped to suit antenna fixing tube (tube dia to be confirmed) Cable exit holes to customers preference

Ladder brackets start 2-3 metres from ground level. Access made via removable ladder

Shaft constructed from heavy duty Ø273 circular hollow section

A

B

C

D

E

15 METRE MONO POLE

VenturaThe Structural Steel Division Of LED Evolution

Page 11: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS

CAMERA / FLOODLIGHTING HINGED POLE

BRIT-CF-H Edition A Sheet 1/1

The columns are designed to withstand wind speed of 50m/s, topography, ground roughness & statistical factor of 1.0

Columns are manufactured in compliance to British Standard BS 5649 / EN 40

Materials used for lighting columns are in compliance to EN 10025/JIS G3101 SS400

Lighting columns are longtitudenally seam welded conform to BS 5135 by automatic continuous metal inert gas (MIG) process

Columns are anti-corroded by hot-dip galvanising, compliance to galvanising standard BS 729 : 1971

Service door dimensions are given as a guide only. The engineer must satisfy himself that the dimension given is adequate for the installation of the required control gears

All dimensions are in mm unless otherwise specified

TECHNICAL SPECIFICATIONS

CAMERA / FLOODLIGHTING HINGED POLE

VenturaThe Structural Steel Division Of LED Evolution

Page 12: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS

CCTV CITY CENTRE POLE

BRIT-CC-CC Edition A Sheet 1/1

Structural Steelwork: BS EN 10210-1:1994, BS EN 10210-2:1997

General Steelwork:BS 1449:1991, BS 1387:1985, BS EN 10025:1993

Welding Procedures:Comply with BS 5135:1994

Hot Dipped Galvanised:BS EN 729:1971, BS EN ISO 1461:1999

Fastners:Grade 8.8 BS 3692:2001, BS 4190:2001, DIN 931, DIN 934

Design Wind Loadings:Based on CP3 Chapter V Pt 2 (1972) & BS 6399 Pt 2 (1997)

Paint Finishes:BS 4800 & RAL colour range

MANUFACTURING STANDARDS

CITY CENTRE POLE - BASE PLATE MOUNTED

Serial No Height Pole Dia

Cabinet Height

Cabinet Size

Base Plate Thickness

Door Apperture

Weight

A B C D

(m) (mm) (mm) (mm2) (mm) (mm) (kg)

CCP3DD 3 168 1400 500 12 900(h)x300(w) 200

CCP4DD 4 168 1400 500 12 900(h)x300(w) 225

CCP5DD 5 168 1400 500 12 900(h)x300(w) 250

CCP6DD 6 168 1400 500 12 900(h)x300(w) 275

CCP7DD 7 168 1400 500 15 900(h)x300(w) 300

CCP8DD 8 168 1400 500 15 900(h)x300(w) 325

CCP9DD 9 219 1400 500 20 900(h)x300(w) 425

CCP10DD 10 219 1400 500 20 900(h)x300(w) 460

CCP11DD 11 219 1400 500 25 900(h)x300(w) 495

CCP12DD 12 219 1400 500 25 900(h)x300(w) 530

CCTV CITY CENTRE POLE

VenturaThe Structural Steel Division Of LED Evolution

Page 13: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS

CCTV FIXED SQUARE POLE

BRIT-CC-FS Edition A Sheet 1/1

Structural Steelwork: BS EN 10210-1:1994, BS EN 10210-2:1997

General Steelwork:BS 1449:1991, BS 1387:1985, BS EN 10025:1993

Welding Procedures:Comply with BS 5135:1994

Hot Dipped Galvanised:BS EN 729:1971, BS EN ISO 1461:1999

Fastners:Grade 8.8 BS 3692:2001, BS 4190:2001, DIN 931, DIN 934

Design Wind Loadings:Based on CP3 Chapter V Pt 2 (1972) & BS 6399 Pt 2 (1997)

Paint Finishes:BS 4800 & RAL colour range

MANUFACTURING STANDARDS

FIXED SQUARE POLE - BASE PLATE MOUNTED

Serial No Height Pole Size

Gusset Thickness

Base Plate Thickness

Door Apperture

Weight

A B

(m) (mm2) (mm) (mm) (mm) (kg)

FSP3 3 100 6 12 400(h)x90(w) 100

FSP4 4 100 6 12 400(h)x90(w) 110

FSP5 5 120 6 12 400(h)x110(w) 130

FSP6 6 120 6 12 400(h)x110(w) 150

FSP7 7 120 8 15 400(h)x110(w) 225

FSP8 8 150 8 15 450(h)x130(w) 248

FSP9 9 150 10 20 450(h)x130(w) 359

FSP10 10 150 10 20 450(h)x130(w) 400

FSP11 11 200 15 25 500(h)x180(w) 425

FSP12 12 200 15 25 500(h)x180(w) 460

CCTV FIXED SQUARE POLE

VenturaThe Structural Steel Division Of LED Evolution

Page 14: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS

S C C TILT DOWN POLE

BRIT-SCC-TD Edition A Sheet 1/1

Structural Steelwork: BS EN 10210-1:1994, BS EN 10210-2:1997

General Steelwork:BS 1449:1991, BS 1387:1985, BS EN 10025:1993

Welding Procedures:Comply with BS 5135:1994

Hot Dipped Galvanised:BS EN 729:1971, BS EN ISO 1461:1999

Fastners:Grade 8.8 BS 3692:2001, BS 4190:2001, DIN 931, DIN 934

Design Wind Loadings:Based on CP3 Chapter V Pt 2 (1972) & BS 6399 Pt 2 (1997)

Paint Finishes:BS 4800 & RAL colour range

MANUFACTURING STANDARDS

S C C TILT DOWN POLE - BASE PLATE MOUNTED

Serial No Height Pivot Height / Size

Lower Section /

Size

Upper Section /

Size

Extension Length /

Size

Gussett Thickness

Base Plate Thickness

Door Apperture

Rear TIlt Clearance

Weight

A B C D F

(m) (mm / mm2) (m / mm2) (m / mm2) (m / mm2) (mm) (mm) (mm) (mm) (kg)

SCC3TD 3 1500 / 200 3 / 120 N/A N/A 6 12 400(h)x100(w) 1500 165

SCC4TD 4 1500 / 200 3 / 120 1 / 100 N/A 6 12 400(h)x100(w) 1500 196

SCC5TD 5 1500 / 200 3 / 120 2 / 120 N/A 8 15 400(h)x120(w) 1500 281

SCC6TD 6 1500 / 200 3 / 200 3 / 150 N/A 10 20 400(h)x170(w) 1500 450

SCC7TD 7 2000 / 200 3 / 200 3 / 150 1 / 100 10 20 400(h)x170(w) 2000 500

SCC8TD 8 2000 / 200 3 / 200 3 / 150 2 / 100 10 20 400(h)x170(w) 2000 533

SCC9TD 9 2000 / 200 3 / 200 3 / 150 3 / 100 12 25 400(h)x170(w) 2000 566

SCC10TD 10 2000 / 200 4 / 200 3 / 150 3 / 100 12 25 400(h)x170(w) 2000 592

S C C TILT DOWN POLE

VenturaThe Structural Steel Division Of LED Evolution

Page 15: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS

CCTV VANDAL RESISTANT POLE

BRIT-CC-VR Edition A Sheet 1/1

This range protects against the following:

• Ramming by vehicles• Pole cabinet being torched• Pole shaft being cut• Camera theft• Camera attack by projectiles

Optional Extras:

• Double skin cabinet and shaft• Various anti-ram type bases available• Various decorative designs available• Anti-ladder brackets• Top pole cage• All poles can be painted to any RAL / BS colour• Anti-tamper switches can be fitted to doors• Anti-poster / graffiti / climb paints can be applied

CCTV VANDAL RESISTANT POLE

VenturaThe Structural Steel Division Of LED Evolution

Page 16: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS

2 FIXED CAMERA & 1 PTZ BRACKET

BRIT-2FC-B Edition A Sheet 1/1

Camera adaptor to accept 2 x fixed cameras / 1 x PTZ cameras

The ACME BRIT-2FC-B bracket allows 2 x fixed cameras and 1 x PTZ camera to be mounted to our entire pole / tower range. Bracket fitted with 2 fully rotational swivel mounts to achieve the best camera position. (other uses) The standard 101.6PTZ fixing can be used to mount a dome swan neck type mount and the swivel bracket can be removed to fit lights.

Product:• Brackets fully cable managed for a tamper proof installation• Will fit to all ACME poles and towers• Fully galvanised for maximum weather protection• Painted to most RAL / BS colours• Fully rotational swivel mounts for camera positioning• Hole centres on mounting plate to suit most housings• Bracket is fitted to pole by standard 101.6PCD fixing

Camera Arm Length Upstands Available

A B

375mm 150 / 300 / 500

A A

B

2 FIXED CAMERA & 1 PTZ BRACKET

VenturaThe Structural Steel Division Of LED Evolution

Page 17: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS

CCTV FIXED HOUSING BRACKET

BRIT-FH-B Edition A Sheet 1/1

Fixed housing bracket

Fixed wall mount brackets are the perfect solution to mount static cameras externally to brickwork, cladded type buildings. Fitted with a fully rotational swivel mount to position camera were required

Product:• Fully galvanised for maximum weather protection• Painted to most RAL / BS colours if required• Fitted with fully rotational swivel mounts to position camera housing where required• Customised outreach lengths available• Sleeved anchors can be supplied for wall fixing• CMA corner mount adaptors convert this bracket to corner mount

Camera Arm Length

A

350mm / 600mm

A

CCTV FIXED HOUSING BRACKET

VenturaThe Structural Steel Division Of LED Evolution

Page 18: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS

DOME BRACKET CORNER MOUNT

BRIT-CM-DB Edition A Sheet 1/1

Dome bracket corner mount

These swept dome brackets are available to suit most dome manufacturers fixings. THese are manufactured with heavy duty fixings to suit brickwork, cladded buildings.

Product:• Fully galvanised for maximum weather protection• Painted to most RAL / BS colours if required• Fixings available to suit most manufacturers domes• Bracket is fitted to wall via 8 No 12mm holes• Various dome leg heights available

Product Code Swan Neck Outreach Swan Neck Height Corner Strap Length

A B C

SDBCM 500 700 400

A

C

BR250

DOME BRACKET CORNER MOUNT

VenturaThe Structural Steel Division Of LED Evolution

Page 19: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

1 2 3 4

1 4

A

B

C

D

E

F

A

B

C

D

E

F

Ventura (Europe) - 1000 North Circular Road, London NW2 7JP www.venturalighting.co.uk Tel: +44 (0) 208 208 4081

DESIGN SUBJECT TO CONTINUOUS IMPROVEMENT - COPYRIGHT VENTURA (EUROPE) 2014

Itemref Quantity Title/Name, Designation, Material, Dimension, etc. Article No./Reference

Designed & Checked by SSG Approved by (Date) 13/11/2014 Scale NTS

FOUNDATION FOR HINGED POLE

BRIT-F-H Edition A Sheet 1/1

Foundation Details

The below recommended foundation details are typical and some site conditions may require increased concrete base sizes. A minimum soil bearing of 75 n/m sq is assumed. We recommend pressures below the minimum are assessed by a structural engineer.

Product Code Height (m) Base Area (mm) Depth (mm) Concrete Vol (M2)

W x W D

VLIP3 3 1000 x 1000 500 0.5

VLIP4 4 1000 x 1000 750 0.75

VLIP5 5 1000 x 1000 750 0.75

VLIP6 6 1000 x 1000 1000 1

VLIP7 7 1200 x 1200 1000 1.44

VLIP8 8 1300 x 1300 1000 1.69

VLIP9 9 1400 x 1400 1000 1.96

VLIP10 10 1500 x 1500 1000 2.25

VLIP11 11 1700 x 1700 1200 3.46

VLIP12 12 1750 x 1750 1200 3.67

D

Template

65mm

Bolt Plates

Cable Duct

Concrete Base

W x W

1. Excavate hole as per recommended area and depth2. Assemble root base as shown in diagram 1 ensuring that it is level and that four studs protrude at 65mm above base of wooden setting template.3. Ensure ducting is in place (we recommend that a minimum of 150mm extrudes from ground level), if required this can be trimmed back once concrete is set.4. Pour concrete ensuring that it is a mix of M20 grade.5. Push template and bolts into concrete and level accordingly.6. When fitting the column, remove template and ensure that the concrete base is in complete contact with the underside of the column and torque the nuts to 230-270 Nm (175-200 ft/lb).7. When the column has been fitted, protect the studs with a suitable protective coating. Denzo tape or similar is recommended.8. After reinstatement it is essential that a load bearing grout is used to fill the void between base plate and concrete. Failure to do so may cause deflection in pole. It is recommended that the poles are grouted internally to ensure water tight.

Diagram 1Template Assembled

Diagram 2Foundation Cross Section

FOUNDATION FOR HINGED POLE

VenturaThe Structural Steel Division Of LED Evolution

Page 20: Ventura - LED · PDF file · 2016-11-22Ventura Lighting (Europe) - 1000 North Circular Road, ... BRIT-27 SRTMR012 12000 193.7 1750 2000 168.3 10250 600x115 1000 139.7x300 ... Design

VenturaThe Structural Steel Division Of LED Evolution

Ventura Lighting (Europe) - 1000 North Circular Road, London NW2 7JPWeb: www.venturalighting.co.uk Tel: +44 (0)20 8208 4081