PL01301001E For more information visit: www.cutler-hammer.eaton.com VCP-T, VCP-TR, T-VAC & T-VACR Vacuum Circuit Breakers Price List New Information Description Page VCP-T, VCP-TR, T-VAC & T-VACR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . 2 VCP-T & T-VAC Drawout Cassettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4 Dimensional Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5 VCP-T Drawout Circuit Breakers (Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6 VCP-TR Fixed Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7 T-VAC Drawout Circuit Breakers (Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8 T-VACR Fixed Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 VCP-T & T-VAC Drawout Cassettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Digitrip RMS Trip Units (Protective Relays) . . . . . . . . . . . . . . . . . . . . . . . . . . . 10 Digitrip RMS Trip Unit Current Sensors & Matching Rating Plugs . . . . . . . . . 11 Electric Charging Option (Factory Installed) . . . . . . . . . . . . . . . . . . . . . . . . . . . 11 Second Shunt Trip Device (Factory Installed). . . . . . . . . . . . . . . . . . . . . . . . . . 12 Close Spring Release Device (Factory Installed) . . . . . . . . . . . . . . . . . . . . . . . 12 Undervoltage Release Device (Factory Installed) . . . . . . . . . . . . . . . . . . . . . . . 12 Field Installable Accessories/Components (Optional) . . . . . . . . . . . . . . . . . . . 13 Selection/Order Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Transcript of VCP-T, VCP-TR, T-VAC & T-VACR Vacuum Circuit Breakers · VCP-T, VCP-TR, T-VAC & T-VACR Vacuum...

  • PL01301001E For more information visit: www.cutler-hammer.eaton.com

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    Price List

    New Information

    Description Page

    VCP-T, VCP-TR, T-VAC & T-VACR Circuit Breakers . . . . . . . . . . . . . . . . . . . . . .

    2

    VCP-T & T-VAC Drawout Cassettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    4

    Dimensional Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    5

    VCP-T Drawout Circuit Breakers (Only). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    6

    VCP-TR Fixed Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    7

    T-VAC Drawout Circuit Breakers (Only) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    8

    T-VACR Fixed Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    9

    VCP-T & T-VAC Drawout Cassettes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    10

    Digitrip RMS Trip Units (Protective Relays) . . . . . . . . . . . . . . . . . . . . . . . . . . .

    10

    Digitrip RMS Trip Unit Current Sensors & Matching Rating Plugs. . . . . . . . .

    11

    Electric Charging Option (Factory Installed) . . . . . . . . . . . . . . . . . . . . . . . . . . .

    11

    Second Shunt Trip Device (Factory Installed). . . . . . . . . . . . . . . . . . . . . . . . . .

    12

    Close Spring Release Device (Factory Installed) . . . . . . . . . . . . . . . . . . . . . . .

    12

    Undervoltage Release Device (Factory Installed). . . . . . . . . . . . . . . . . . . . . . .

    12

    Field Installable Accessories/Components (Optional) . . . . . . . . . . . . . . . . . . .

    13

    Selection/Order Entry . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

    15

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • For more information visit: www.cutler-hammer.eaton.com PL01301001E

    Price List

    Page

    2

    Effective: February 2003

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    VCP-T, VCP-TR, T-VAC & T-VACR Circuit Breakers

    Standard Features

    Grounded steel barrier between mechanism and primary conductors.

    Spring loaded, silver-plated primary disconnects (drawout breaker).

    Silver-plated primary connections (fixed circuit breaker).

    Manual charging of closing springs (includes shunt trip).

    Integral spring charging handle.

    Auxiliary switch (5a and 5b contacts).

    Mechanical operations counter.

    24, 48, 125 and 250 Vdc, 120 and 240 Vac control.

    Shunt trip.

    ON and OFF pushbuttons.

    Integral lifting hooks.

    Through or behind door operation.

    Identified/dedicated secondaries.

    Secondary umbilical cord (drawout circuit breaker).

    Secondary disconnect block (fixed circuit breaker).

    Two-step stored energy mechanism.

    O – 0.3s – CO – 15s – CO.

    Anti-pump.

    Trip free.

    Latch check switch.

    Visible contact erosion indicator.

    Visible contact wipe indicator.

    Disconnect, Test and Connect (drawout circuit breaker).

    Integral levering mechanism(drawout circuit breaker).

    Field installable accessories.

    ANSI IEC

    Up to 15 kVUp to 25 kAUp to 1200 A (drawout)Up to 1600 A (fixed)

    Up to 17.5 kVUp to 25 kAUp to 1250 A (drawout)Up to 1600 A (fixed)

    Fixed Circuit Breaker Drawout Circuit Breaker(Optional Trip Unit Installed)

    Drawout Circuit Breaker and Drawout Cassette

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • PL01301001E For more information visit: www.cutler-hammer.eaton.com

    Price List

    Effective: February 2003 Page

    3

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    General Overview

    Eaton’s Cutler-Hammer VCP-T (ANSI) and T-VAC (IEC) vacuum circuit breakers are drawout devices used in conjunction with drawout cassettes. VCP-TR (ANSI) and T-VACR (IEC) vacuum circuit breakers are fixed mounted devices.

    VCP-T and T-VAC drawout circuit breakers are comprised of two parts. One part, the upper breaker element, is much like the fixed circuit breaker. The second part, the lower portion, is called the cradle. The cradle primarily provides the levering mechanism for moving the drawout circuit breaker into and out of the CONNECTED position within the drawout cassette.

    All circuit breakers utilize a two-step stored energy mechanism.

    The fixed type VCP-TR and T-VACR circuit breakers use copper primary conductors with silver-plated connec-tions. Upper and lower terminals have two holes for making bolted horizontal bus or cable connections. Secondary connections can be made through a standard secondary disconnect block or an optional screw type terminal block available in kit form.

    The drawout type VCP-T and T-VAC circuit breakers utilize spring loaded, silver-plated primary disconnects to make their primary connection. The primary disconnects mate with the rigidly mounted, silver-plated stabs mounted in the rear of the drawout cassette. Secondary connec-tions are made through the use of an umbilical cord which comes from the factory already attached to the drawout circuit breaker. The unat-tached end of the umbilical cord is connected to the drawout cassette during equipment installation.

    All circuit breakers, whether fixed or drawout, are supplied as standard with a front mounted 5a and 5b contact auxiliary switch for customer use.

    Both fixed and drawout manually operated circuit breakers are supplied with one shunt trip. Manually operated circuit breakers are normally closed and opened by hand using the manual ON and manual OFF buttons respec-tively. Access to these buttons can be limited or prevented through the use of optional covers.

    The standard shunt trip is used to elec-trically trip (open) the circuit breaker remotely. In addition, other optional electrically operated devices are avail-able to close or trip manually operated circuit breakers remotely.

    Manually operated circuit breakers are pre-wired to accept the addition of an optional spring charging motor.

    For electrically operated circuit break-ers, the springs are normally charged through the use of an electric motor. A factory supplied electrically oper-ated circuit breaker is always equipped with a spring release to close the circuit breaker electrically and a shunt trip to trip (open) the circuit breaker electrically. A second shunt trip or an undervoltage release are other available optional devices.

    All circuit breakers have a trip free operation feature and a mechanical anti-pump feature as standard. Any circuit breaker capable of being electri-cally closed is provided with a latch check switch. The latch check switch ensures that all closing conditions are met before the circuit breaker can be electrically closed.

    A variety of other optional devices are available for specific applications and/or requirements, such as the fam-ily of microprocessor-based trip units (protective relays) Digitrip

    E

    RMS.

    Typical Fixed Circuit Breaker Rear View

    Typical Drawout Circuit Breaker Rear View

    Secondary Umbilical Cord Shown Attached to Drawout Circuit Breaker

    Digitrip RMS Programmable Trip Unit Installed

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • For more information visit: www.cutler-hammer.eaton.com PL01301001E

    Price List

    Page

    4

    Effective: February 2003

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    VCP-T & T-VAC Drawout Cassettes

    General Overview

    The drawout cassette is designed to support the drawout circuit breaker and provide a means by which the drawout circuit breaker can complete its secondary and primary electrical connections.

    VCP-T and T-VAC drawout cassettes permit the drawout circuit breakers to be in one of three positions within the cassettes: DISCONNECT, TEST and CONNECT.

    The cassette provides a compatible sec-ondary connector for attachment of the one end of the secondary umbilical cord.

    Silver-plated primary stabs are rigidly mounted in the rear of the cassette to engage the spring loaded primary disconnects on the rear of the circuit breaker.

    The levering mechanism, as described earlier, is part of the circuit breaker. The cassette does, however, provide a positive guidance as the circuit breaker is levered into and out of the CON-NECTED position.

    Primary connection stabs are provided on the rear of the cassette for connec-tion into the system in which the cir-cuit breaker will function.

    Metallic primary safety shutters are provided as standard in all cassettes. The shutters cover the fixed primary stabs when the circuit breaker is not in the CONNECTED position. As the circuit breaker is levered to the CON-NECTED position, the safety shutters automatically move out of the way permitting the primary connection to be made. A standard padlocking device is provided to permit padlock-ing the primary shutters in an OPEN position or CLOSED position.

    There are two different drawout cas-settes used with VCP-T and T-VAC dra-wout circuit breakers. Which cassette is used is determined by the lightning impulse withstand voltage (LIWV) of the circuit breaker selected. All circuit breakers rated for 60 kV LIWV, whether VCP-T or T-VAC, use a Style 69C3350G01 drawout cassette. All circuit breakers rated for 75 or 95 kV LIWV, whether VCP-T or T-VAC, use a Style 69C3350G02 drawout cassette. Both drawout cassette provide the same standard features and serve the exact same purpose. Visually, there are few noticeable differences between the two cassettes.

    Levering Circuit Breaker Into Cassette

    Circuit Breaker in CONNECTED Position in Cassette

    Typical 60 kV Cassette Front View

    Typical 60 kV Cassette Rear View

    Typical 75/95 kV Cassette Front View

    Typical 75/95 kV Cassette Rear View

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • PL01301001E For more information visit: www.cutler-hammer.eaton.com

    Price List

    Effective: February 2003 Page

    5

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    Dimensional Details

    Typical Dimensions

    The drawings provided on this page provide typical dimensional informa-tion associated with VCP-T and T-VAC drawout circuit breakers, associated drawout cassettes, as well as VCP-TR and T-VACR fixed circuit breakers.

    Figure 1. VCP-T and T-VAC Drawout Circuit Breaker and Cassette Dimensions in Inches (mm)

    Figure 2. VCP-TR and T-VACR Fixed Circuit Breaker Dimensions in Inches (mm)

    17.00(431.8)

    21.24(539.5)

    5.90(149.9)

    5.90(149.9)

    34.76(882.9) 33.76

    (857.5)

    25.28(642.1)

    22.72(577.1)

    30.38(771.7)

    9.35(237.5)

    12.32(312.9)

    Optional CustomerConnection

    Vertical Barrier(15 kV Only)

    11 GaugeSteel Barrier

    5.13(130.3)

    5.13(130.3)

    1.25(31.8).33

    (8.4)

    3.12(79.2)

    16.34(415.0)

    10.10(256.5)

    3.12(79.2)

    1.97(50.0)

    13.85(351.8)

    7.19(182.6)

    10.31(261.9)

    13.50(342.9)3.65

    (92.7)18.61

    (472.7)

    .38(9.7)

    9.74(247.4)

    19.48(494.8)

    20.45(519.4)

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • For more information visit: www.cutler-hammer.eaton.com PL01301001E

    Price List

    Page

    6

    Effective: February 2003

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    VCP-T Drawout Circuit Breakers (Only)

    The list prices shown in

    Table 1

    are for standard VCP-T drawout circuit breakers with an electric charging motor, one shunt trip, a spring release coil and a latch check switch. The circuit breaker list prices do not include Digitrip RMS trip units (protective relays) or drawout cassettes.

    Consult the Cutler-Hammer business for the list price of a manually operated VCP-T drawout circuit breaker

    .

    Table 1. ANSI Type VCP-T Circuit Breaker Complete With Levering Mechanism (ANSI C37.04 and C37.09)

    1

    Drawout cassette not included with circuit breaker in

    Table 1

    . Refer to

    Table 5

    for a compatible drawout cassette and list price adder.

    2

    Refer to

    Table 6

    for the 520V, 1150V or 1150Vi Digitrip RMS trip unit with rating plug and sensors list price adders. Refer to

    Table 7

    for rating plug/sensor selections.

    3

    Refer to

    Table 8

    for electric charging motor control voltage selections.

    4

    Refer to

    Tables 9

    ,

    10

    ,

    11

    and

    12

    for additional factory and/or field installed accessory selections and list price adders.

    5

    Use Type 150 VCP-T when 95 kV Impulse Withstand required.

    Identification Rated Values Ordering

    CircuitBreakerType

    RatedVoltage

    Insulation Level ContinuousCurrent

    Short CircuitBreakingCurrent

    2 SecondShort TimeCurrent

    Short CircuitMakingCurrent

    MechanicalEnduranceC – O

    PriceU.S. $

    1234

    PowerFrequency

    ImpulseWithstand

    kV rms kV rms kV Peak Amperes kA rms kA rms kV Peak Operations

    50 VCP-T16 4.76 19 60 600 8001200

    16 16 42 20,00020,00010,000

    11,200.11,400.11,600.

    50 VCP-T20 4.76 19 60 600 8001200

    20 20 52 10,00010,00010,000

    11,500.11,700.11,900.

    50 VCP-T25 4.76 19 60 600 8001200

    25 25 65 10,00010,00010,000

    11,600.11,800.12,100.

    75 VCP-T16 8.25 20 60

    5

    600 8001200

    16 16 42 20,00020,00010,000

    12,500.12,700.12,900.

    75 VCP-T20 8.25 20 60

    5

    600 8001200

    20 20 52 10,00010,00010,000

    13,100.13,300.13,500.

    75 VCP-T25 8.25 20 60

    5

    600 8001200

    25 25 65 10,00010,00010,000

    13,700.13,900.14,100.

    150 VCP-T16 15.00 36 95 600 8001200

    16 16 42 10,00010,00010,000

    13,000.13,200.13,400.

    150 VCP-T20 15.00 36 95 600 8001200

    20 20 52 10,00010,00010,000

    13,600.13,800.14,000.

    150 VCP-T25 15.00 36 95 600 8001200

    25 25 65 10,00010,00010,000

    14,200.14,400.14,600.

    15 kV VCP-T Drawout Circuit Breaker and Drawout Cassette

    Front View 15 kV VCP-T Drawout Circuit Breaker Including Levering Mechanism (Trip Unit Optional)

    Rear View 15 kV VCP-T Drawout Circuit Breaker

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • PL01301001E For more information visit: www.cutler-hammer.eaton.com

    Price List

    Effective: February 2003 Page

    7

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    VCP-TR Fixed Circuit Breakers

    The list prices shown in

    Table 2

    are for standard VCP-TR fixed circuit breakers with an electric charging motor, one shunt trip, a spring release coil and a latch check switch. The circuit breaker list prices do not include Digitrip RMS trip units (protective relays).

    Consult the Cutler-Hammer business for the list price of a manually operated VCP-TR fixed circuit breaker

    .

    Table 2. ANSI Type VCP-TR Circuit Breaker (ANSI C37.04 and C37.09)

    1

    Refer to

    Table 6

    for the 520V, 1150V or 1150Vi Digitrip RMS trip unit with rating plug and sensors list price adders. Refer to

    Table 7

    for rating plug/sensor selections.

    2

    Refer to

    Table 8

    for electric charging motor control voltage selections.

    3

    Refer to

    Tables 9

    ,

    10

    ,

    11

    and

    12

    for additional factory and/or field installed accessory selections and list price adders.

    4

    Use Type 150 VCP-T when 95 kV Impulse Withstand required.

    Front View 15 kV VCP-TR Fixed Circuit Breaker Rear View 15 kV VCP-TR Fixed Circuit Breaker

    Identification Rated Values Ordering

    CircuitBreakerType

    RatedVoltage

    Insulation Level ContinuousCurrent

    Short CircuitBreakingCurrent

    2 SecondShort TimeCurrent

    Short CircuitMakingCurrent

    MechanicalEnduranceC – O

    PriceU.S. $

    123

    PowerFrequency

    ImpulseWithstand

    kV rms kV rms kV Peak Amperes kA rms kA rms kV Peak Operations

    50 VCP-TR16 4.76 19 60 60012001600

    16 16 42 20,00020,00010,000

    9,800.10,000.10,200.

    50 VCP-TR20 4.76 19 60 60012001600

    20 20 52 10,00010,00010,000

    10,400.10,600.10,800.

    50 VCP-TR25 4.76 19 60 60012001600

    25 25 65 10,00010,00010,000

    11,000. 11,200.11,400.

    75 VCP-TR16 8.25 20 60

    4

    60012001600

    16 16 42 20,00020,00010,000

    10,800. 11,000.11,200.

    75 VCP-TR20 8.25 20 60

    4

    60012001600

    20 20 52 10,00010,00010,000

    11,400. 11,600.11,800.

    75 VCP-TR25 8.25 20 60

    4

    60012001600

    25 25 65 10,00010,00010,000

    12,000. 12,200.12,400.

    150 VCP-TR16 15.00 36 95 60012001600

    16 16 42 10,00010,00010,000

    11,300. 11,500.11,700.

    150 VCP-TR20 15.00 36 95 60012001600

    20 20 52 10,00010,00010,000

    11,900. 12,100.12,300.

    150 VCP-TR25 15.00 36 95 60012001600

    25 25 65 10,00010,00010,000

    12,500. 12,700.12,900.

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • For more information visit: www.cutler-hammer.eaton.com PL01301001E

    Price List

    Page

    8

    Effective: February 2003

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    T-VAC Drawout Circuit Breakers (Only)

    The list prices shown in

    Table 3

    are for standard T-VAC drawout circuit breakers with an electric charging motor, one shunt trip, a spring release coil and a latch check switch. The circuit breaker list prices do not include Digitrip RMS trip units (protective relays) or drawout cassettes.

    Consult the Cutler-Hammer business for the list price of a manually operated T-VAC drawout circuit breaker.

    Table 3. IEC Type T-VAC Circuit Breaker Complete With Levering Mechanism (Certified to IEC62271-100)

    1

    Drawout cassette not included with circuit breaker in

    Table 3

    . Refer to

    Table 5

    for a compatible drawout cassette and list price adder.

    2

    Refer to

    Table 6

    for the 520V, 1150V or 1150Vi Digitrip RMS trip unit with rating plug and sensors list price adders. Refer to

    Table 7

    for rating plug/sensor selections.

    3

    Refer to

    Table 8

    for electric charging motor control voltage selections.

    4

    Refer to

    Tables 9

    ,

    10

    ,

    11

    and

    12

    for additional factory and/or field installed accessory selections and list price adders.

    5

    Use Type 175 T-VAC when 95 kV Impulse Withstand required.

    Front View 7.2 kV T-VAC Drawout Circuit Breaker Including Levering Mechanism (Trip Unit Optional)

    Rear View 7.2 kV T-VAC Drawout Circuit Breaker

    Identification Rated Values Ordering

    CircuitBreakerType

    VoltageClass(U)

    Insulation Level NormalCurrent(In)

    Short CircuitBreakingCurrent (Isc)

    3 SecondShort TimeCurrent

    Short CircuitMakingCurrent

    MechanicalEnduranceC – O

    PriceU.S. $

    1234

    PowerFrequency

    LightningImpulse (Uw)

    kV rms kV rms kV Peak Amperes kA rms kA rms kV Peak Operations

    72 T-VAC16 7.2 20 60 630 8001250

    16 16 42 20,00020,00010,000

    11,600.11,800.12,000.

    72 T-VAC20 7.2 20 60 630 8001250

    20 20 52 10,00010,00010,000

    12,100.12,300.12,500.

    72 T-VAC25 7.2 20 60 630 8001250

    25 25 65 10,00010,00010,000

    12,700. 12,900.13,100.

    120 T-VAC16 12.0 28 75

    5

    630 8001250

    16 16 42 10,00010,00010,000

    13,000. 13,200.13,400.

    120 T-VAC20 12.0 28 75

    5

    630 8001250

    20 20 52 10,00010,00010,000

    13,600. 13,800.14,000.

    120 T-VAC25 12.0 28 75

    5

    630 8001250

    25 25 65 10,00010,00010,000

    14,200. 14,400.14,600.

    175 T-VAC16 17.5 38 95 630 8001250

    16 16 42 10,00010,00010,000

    13,500. 13,700.13,900.

    175 T-VAC20 17.5 38 95 630 8001250

    20 20 52 10,00010,00010,000

    14,100. 14,300.14,500.

    175 T-VAC25 17.5 38 95 630 8001250

    25 25 65 10,00010,00010,000

    14,700. 14,900.15,100.

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • PL01301001E For more information visit: www.cutler-hammer.eaton.com

    Price List

    Effective: February 2003 Page

    9

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    T-VACR Fixed Circuit Breakers

    The list prices shown in

    Table 4

    are for standard T-VACR fixed circuit breakers with an electric charging motor, one shunt trip, a spring release coil and a latch check switch. The circuit breaker list prices do not include Digitrip RMS trip units (protective relays).

    Consult the Cutler-Hammer business for the list price of a manually operated VCP-TR fixed circuit breaker

    .

    Table 4. IEC Type T-VACR Circuit Breaker (Certified to IEC62271-100)

    1 Drawout cassette not included with circuit breaker in Table 3. Refer to Table 5 for a compatible drawout cassette and list price adder.2 Refer to Table 6 for the 520V, 1150V or 1150Vi Digitrip RMS trip unit with rating plug and sensors list price adders. Refer to Table 7 for rating

    plug/sensor selections. 3 Refer to Table 8 for electric charging motor control voltage selections. 4 Refer to Tables 9, 10, 11 and 12 for additional factory and/or field installed accessory selections and list price adders.5 Use Type 175 T-VAC when 95 kV Impulse Withstand required.

    Front View 7.2 kV T-VACR Fixed Circuit Breaker Rear View 7.2 kV T-VACR Fixed Circuit Breaker

    Identification Rated Values Ordering

    CircuitBreakerType

    VoltageClass(U)

    Insulation Level NormalCurrent(In)

    Short CircuitBreakingCurrent (Isc)

    3 SecondShort TimeCurrent

    Short CircuitMakingCurrent

    MechanicalEnduranceC – O

    PriceU.S. $1234

    PowerFrequency

    LightningImpulse (Uw)

    kV rms kV rms kV Peak Amperes kA rms kA rms kV Peak Operations

    72 T-VACR16 7.2 20 60 63012501600

    16 16 42 20,00020,00010,000

    10,800.11,000.11,200.

    72 T-VACR20 7.2 20 60 63012501600

    20 20 52 10,00010,00010,000

    11,400.11,600.11,800.

    72 T-VACR25 7.2 20 60 63012501600

    25 25 65 10,00010,00010,000

    12,000. 12,200.12,400.

    120 T-VACR16 12.0 28 75 5 63012501600

    16 16 42 10,00010,00010,000

    11,300. 11,500.11,700.

    120 T-VACR20 12.0 28 75 5 63012501600

    20 20 52 10,00010,00010,000

    11,900. 12,100.12,300.

    120 T-VACR25 12.0 28 75 5 63012501600

    25 25 65 10,00010,00010,000

    12,500. 12,700.12,900.

    175 T-VACR16 17.5 38 95 63012501600

    16 16 42 10,00010,00010,000

    11,800. 12,000.12,200.

    175 T-VACR20 17.5 38 95 63012501600

    20 20 52 10,00010,00010,000

    12,400. 12,600.12,800.

    175 T-VACR25 17.5 38 95 63012501600

    25 25 65 10,00010,00010,000

    13,000. 13,200.13,400.

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • For more information visit: www.cutler-hammer.eaton.com PL01301001E

    Price ListPage 10 Effective: February 2003

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    There are two different drawout cassettes used with VCP-T and T-VAC drawout circuit breakers. Select the cassette based on the rated impulse withstand voltage level of the VCP-T circuit breaker from Table 1 or the rated lightning impulse withstand voltage level of the T-VAC circuit breaker from Table 3.

    Table 5. Drawout Cassette

    Three Digitrip Trip Units are available: the 520V, 1150V and the 1150Vi. Three current sensors and one matching fixed rating plug are supplied as stan-dard with any trip unit model selected for use with circuit breakers from Tables 1, 2, 3 or 4. The current rating of the current sensors and matching rating plug are selected from Table 7.

    Table 6. Trip Unit Models

    Rated ImpulseWithstand or RatedLightning Impulse

    StyleNumber

    PriceU.S. $

    60 kV75 or 95 kV

    69C3350G0169C3350G02

    3050.3150.

    Trip UnitModel

    PriceU.S. $

    520V (w/o Communications)1150V (w/ Communications)1150Vi (w/ Communications)

    3510.5600.5485.

    VCP-T & T-VAC Drawout Cassettes

    Digitrip RMS Trip Units (Protective Relays)

    Drawout Cassette (Front View and Rear View)

    Model 520V Model 1150V (ANSI) Model 1150Vi (IEC)

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • PL01301001E For more information visit: www.cutler-hammer.eaton.com

    Price ListEffective: February 2003 Page 11

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    The available current sensors and matching rating plugs available for use with the trip units from Table 6 are shown in Table 7.

    Table 7. Current Sensors/Rating Plugs

    Standard circuit breakers include electric spring charging. When electric charging is selected, an electric motor is provided to charge the closing springs along with a spring release coil and a latch check switch to electri-cally close the circuit breaker. A shunt trip to trip (open) the circuit breaker electrically is standard for all circuit breakers. Choose the desired control voltage from Table 8.

    Table 8. Control Voltages

    Current Rating in Amperes

    100 300 6301200

    200 400 8001250

    250 60010001600

    Available Control Voltages

    24 Vdc 48 Vdc110 Vdc 125 Vdc220 Vdc

    250 Vdc110 Vac 120 Vac220 Vac 240 Vac

    Digitrip RMS Trip Unit Current Sensors & Matching Rating Plugs

    Electric Charging Option (Factory Installed)

    Electric Charging Motor Shown Installed

    Current Sensor Rating Plug

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • For more information visit: www.cutler-hammer.eaton.com PL01301001E

    Price ListPage 12 Effective: February 2003

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    Second Shunt Trip Device (Factory Installed)One shunt trip is supplied as standard with all breakers. An optional, factory installed second shunt trip along with a shunt trip switch is available.

    Table 9. Second Shunt Trip

    Close Spring Release Device (Factory Installed)A close spring release is always sup-plied with the electric charging motor. The close spring release is also avail-able as an optional device installed at the factory on manual breakers.

    Table 10. Close Spring Release

    Undervoltage Release Device (Factory Installed) The undervoltage release is an optional trip device which can be installed at the factory.

    Table 11. Undervoltage Release

    AvailableControl Voltages

    List PriceAdder U.S. $

    24 Vdc 48 Vdc110 Vdc

    270.270.270.

    125 Vdc220 Vdc250 Vdc

    270.270.270.

    110 Vac120 Vac220 Vac240 Vac

    270.270.270.270.

    AvailableControl Voltages

    List PriceAdder U.S. $

    24 Vdc 48 Vdc110 Vdc

    270.270.270.

    125 Vdc220 Vdc250 Vdc

    270.270.270.

    110 Vac120 Vac220 Vac240 Vac

    270.270.270.270.

    AvailableControl Voltages

    List PriceAdder U.S. $

    24 Vdc 48 Vdc110 Vdc

    425.425.425.

    125 Vdc220 Vdc250 Vdc

    425.425.425.

    110 Vac120 Vac220 Vac240 Vac

    425.425.425.425.

    Shunt Trip Device and Shunt Trip Switch Unmounted

    Close Spring Release Device Unmounted

    Undervoltage Release Device Unmounted

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • PL01301001E For more information visit: www.cutler-hammer.eaton.com

    Price ListEffective: February 2003 Page 13

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    Field Installable Accessories/Components (Optional)

    Table 12. Field Installed Accessories/ComponentsAccessory Itemand Description

    Style or Catalog Number

    List PriceAdder U.S. $

    Screw Type Terminal Block: Used with fixed breakers to terminate secondary wiring, leaving female secondary disconnect block.

    Style# 67A3151G01 450.

    Zero Sequence Transformer: (Vectorial Summation) Available with a 100:1 and 200:1 or 50:1 tap ratios.

    100/200 A50 A

    Style# 69C3016G01Style# 69C3016G02

    781.781.

    Digitrip RMS Hand-Held Tester: Used to perform functional local test through trip unit’s test receptacle.

    Cat.# MTST1 2,605.

    OFF Key Lock Provisions: Used to secure fixed circuit breaker in OFF (open) position. Customer responsible for supplying key lock (KirkT, Ronis or Castell) and field mounting the accessory.

    KirkRonisCastell

    Cat.# MBRLCKKCat.# MBRLCKRCat.# MBRLCKC

    410.410.410.

    Door Escutcheon and Gasket: Molded frame and gasket used to seal space between circuit breaker and compartment door cutout.

    Cat.# MDES 145.

    A variety of optional accessory items are available for installation in the field. Unlike the accessory items presented in Tables 6 through 11 which can be factory installed or field installed, items in Table 12 are always field installed.

    Screw Type Terminal Block

    Zero Sequence Transformer

    Hand-Held Tester

    Typical Cover Mounted Lock

    Door Escutcheon and Gasket

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • For more information visit: www.cutler-hammer.eaton.com PL01301001E

    Price ListPage 14 Effective: February 2003

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    Table 12. Field Installed Accessories/Components (Continued)Accessory Itemand Description

    Style or Catalog Number

    List PriceAdder U.S. $

    Pushbutton Cover: Padlockable cover limiting access to ON and OFF pushbuttons. Available with either a plastic or metal frame and both supplied with a hinged plastic window and a plastic closed button cover which blocks access to ON pushbutton.

    Metal Frame with Blocked Close Button CoverPlastic Frame with Blocked Close Button Cover

    Cat.# MCOVCCat.# MCOVH

    102.75.

    IP54 Transparent Cover Kit: Provides protection against dust and dripping water.

    Style# 2C14892G01 540.

    Spout Boot Kit: Kit provides required boots, fins and wire ties sufficient for six drawout circuit breaker cassette spouts, six boots, six fins and 18 wire ties).

    Style# 69C3320G01 1,350.

    Dummy Element Style# 67A3055G01 13,500.

    Simple Ground and Test Device Style# 67A3056G01 14,000.

    Levering-in CrankStandard Levering-in CrankSpin-free Levering-in Crank

    Style# 701B601G22Style# 701B601G21

    175.375.

    Pushbutton Covers

    IP54 Transparent Cover

    Spout Boot

    Dummy Element Ground & Test Device

    Levering-in Crank (Spin-free Model Shown)

    Metal Frame withHinged Plastic Windows

    CLOSEButton Cover

    Plastic Frame withoutHinged Plastic Windows

    Boot Fin

    Wire Tire

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • PL01301001E For more information visit: www.cutler-hammer.eaton.com

    Price ListEffective: February 2003 Page 15

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    Selection/Order Entry

    GeneralSelection and order entry consists of the following steps outlined below:

    1. Select the proper VCP-T, VCP-TR, T-VAC or T-VACR circuit breaker from Tables 1, 2, 3 or 4. Pay partic-ular attention to the information provided above each table and the footnotes at the bottom of each table.

    2. If a VCP-T circuit breaker is selected from Table 1 or a T-VAC circuit breaker is selected from Table 2, select the appropriate cassette from Table 5.

    3. If the circuit breaker selected from Tables 1, 2, 3 or 4 will be supplied with a Digitrip RMS trip unit (pro-tective relay), select the appropri-ate current sensor and rating plug rating from Table 6.

    4. Pick the desired electric charging motor control voltage from Table 8 for circuit breakers selected from Tables 1, 2, 3 or 4.

    5. Select other optional factory installed accessory items from Tables 9, 10 and 11.

    6. Select optional field installable accessory items from Table 12.

    7. All items to be ordered that are not factory installed must have the correct style or catalog num-ber followed by the description. Orders must be entered by style or catalog numbers.

    Order InformationThe following information, as a minimum, is required when ordering VCP-T, VCP-TR, T-VAC or T-VACR circuit breakers:

    1. Circuit breaker type.

    2. Continuous current.

    3. Any additional factory installed accessories.

    4. Control voltage and frequency of all electrical devices.

    5. The current rating of the current sensors and matching rating plug for circuit breakers equipped with a Digitrip RMS trip unit.

    6. Style number of the drawout cassette as a separate item if a VCP-T or T-VAC circuit breaker is being ordered.

    7. Style or catalog number and the description as separate items of any field installable accessory.

    8. The quantities of every item ordered.

    9. Any designated negotiation number.

    10. The order entry suffix is Y3.

    Kirk is a registered trademark of the Kirk Key Interlock Company LLC.

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com

  • Price ListPage 16 Effective: February 2003

    VCP-T, VCP-TR, T-VAC & T-VACRVacuum Circuit Breakers

    © 2003 Eaton CorporationAll Rights ReservedPrinted in USAPublication No. PL01301001EFebruary 2003

    Eaton CorporationCutler-Hammer business unit1000 Cherrington ParkwayMoon Township, PA 15108-4312USAtel: 1-800-525-2000www.cutler-hammer.eaton.com

    www.nationalswitchgear.comCourtesy of NationalSwitchgear.com