Page 1: VC200-R · Rod Drop Module Signal Conditioner / Transmitter /Monitor Key Features • Displacement proximity probe • Keyphasor® signal • 4-20mA output for rod drop value •
Page 2: VC200-R · Rod Drop Module Signal Conditioner / Transmitter /Monitor Key Features • Displacement proximity probe • Keyphasor® signal • 4-20mA output for rod drop value •

1www.precisiontechplus.co.uk

VC200-R Rod Drop Module

Signal Conditioner / Transmitter /Monitor

Key Features• Displacement proximity probe• Keyphasor® signal• 4-20mA output for rod drop value • Measurement in 3 modes Keyphasor® triggered Average Mode Maximum value of rod drop • sensor OK status LED• DIN Rail Mounting• Push-in type connectors• Energized and De-energized relay option• Delay shutdown function• Modbus RTU support• Installation Up/Downward direction• Rotational speed display in RPM

MechanicalInput type 200mv/mils Displacement Sensor Case Material Plastic

(Other sensitivities available) Mounting DIN Rail TS35 (Top Hat)

Rod drop measurement Average, Maximum, Dimensions 134 x 99 x 22.5 mm (H x D x W)

Keyphasor® Triggered Connections Push in connector

Measurement Range 0-2mm Wire Size 0.5 to 4.0 mm

Keyphasor® Input Displacement or photo electric sensor Weight 110 g (nom)

Electrical EnvironmentalPower Input +24 V DC (50 mA) Operating Temperature Range 0 to 55 ºC

Output 4-20 mA= 0-2 mm Installation Category (IEC664) II

(Other ranges available) Equipment Class (IEC536) III

Adjustment Adjustment of zero point EMC EN61326-1:201

Communication Features Relays 1 SPDT, 1A Form C 24Vdc Configuration Software Vibsens-CNFG

Status LED 3 LEDs RPM of Machine, Communication Protocol Modbus RTU

Danger Relay, Sensor Error Communication Port RS-232

PLC

Configuration Software

Recorder

Rod DropTransmitter module

Trip

Dry contact relay

4-20mA

Modbus RTU

Configuration Type of Keypha-sor Sensor Sensitivity Full Scale

Range Drop Danger Installation Location

DelayTrip

RelayType

I = ISO (Standard Order)

F = Factory configured

VC200R is fully configured

via Modbus protocol

D= Displacementsensor

P= Photo electricsensor

200M = 200 mV/mils Displacement008I = 8 V/mm Displacement

XXXm/I = X v/mm

02 = 0-2mmXX =0-XX mm

0100=100 µm0200=200 µm0300=300 µm0400=400 µm

1500=1500 µmxxx=xxx µm

U= Upwarddirection

D= Downwarddirection

01=1s03=3s05=5s06=6s

10=10sXx=xxs

EN =EnergizedDE =De-energized

How To Order Standard order: I-D-200M-02-0800-U-3-EN

DSP Based

Eddy current probe(Rod drop)

Eddy current probe(Phase reference)

potentiometer(on front panel)

DisplacementProximity Probe

Technical Specifications

Page 3: VC200-R · Rod Drop Module Signal Conditioner / Transmitter /Monitor Key Features • Displacement proximity probe • Keyphasor® signal • 4-20mA output for rod drop value •

2www.precisiontechplus.co.uk

Thrust position Conditioner / TransmitterVC200-TThrust Module

Key FeaturesProximity sensor input4-20mA thrust position output Buffered output for dynamic signalTransducer OK status LEDCurrent loop Error status LEDDIN Rail mountingPush-in type connectorsBuffered output for dynamic signalDelay shutdown function

Configuration Sensor type Sensitivity Full Scale Range

NegativeAlert

PositiveAlert

DelayTrip

RelayType

I = ISO (Standard Order)

F = Factory configured

N= - 24v Power Supply

P= + 24v Power Supply

200M = 200 mV/mils sensitivity

008I = 8 V/mm sensitivity

XXXm/I = X v/mm

02 = 0-2mmXX =0-XX mm

100=100 µm200=200 µm300=300 µm400=400 µm500=500 µmxxx=xxx µm

100=100 µm200=200 µm300=300 µm400=400 µm500=500 µmxxx=xxx µm

01=1s03=3s05=5s06=6s

10=10sXx=xxs

EN =EnergizedDE =De-energized

How To Order Standard order: I-N-200M-02-500-500-3-EN

Analog

PLCRecorder

Buffer Output

Trip

Dry contact relay

4-20mA

DisplacementProximity

Probe

Dc-Gap Transmitter

module

Mechanical SpecificationsInput 200mv/mils Displacement transducer Case Material Plastic

(Other sensitivities available) Mounting DIN Rail TS35 (Top Hat)

Transducer Power +/- 24 VDC Dimensions 134 x 99 x 22.5 mm (H x D x W) including BNC

Maximum Current 50mA Connections Push in connector

Measurement Range 0-2mm Conductor Size 0.5 to 4.0 mm

Measurement mode: DC-Gap Value Weight 110 g (nom)

Electrical EnvironmentalInput power +24 V DC (50 mA) Operating Temperature Range 0 to 55 ºC

Output 1 4-20 mA= 0-2mm Installation Category (IEC664) II

(Other ranges available) Equipment Class (IEC536) III

Output 2 (BNC) Buffered dynamic signal output EMC EN61326-1:201

Relays 1 SPDT, 1A Form C 24Vdc

Status LED 4 LEDs Set point negative level, Set point

positive level, Loop and relay

Technical Specifications

Page 4: VC200-R · Rod Drop Module Signal Conditioner / Transmitter /Monitor Key Features • Displacement proximity probe • Keyphasor® signal • 4-20mA output for rod drop value •

3www.precisiontechplus.co.uk

• ICP® /Voltage/Current Transducer • Acceleration/Velocity/ Displacement input signal • 4-20 mA output for dynamic signal / overall value• Buffered output signal • ICP® sensor OK Function• Current loop Error Function• Delay Shutdown Function DIN Rail Mounted• Energized and De-energized relay option• Push-in type connectors

Signal Conditioner / TransmitterVC200-AVibration Module

Key Features

Technical Specifications MechanicalInput 100 mV/g constant current accelerometer

(Other sensitivities available) Case Material Plastic

Frequency Range 1 Hz to 10 kHz (-3dB) (Optional) Mounting DIN Rail TS35 (Top Hat)

Signal Conditioner: Butterworth Dimensions 134 x 99 x 22.5 mm (H x D x W) including BNC

force filter order 8-pole Connections Push in connector

Dynamic Range 80 db Conductor Size 0.5 to 4.0 mm

Measurement mode: Amplifier/integrator to obtain Weight 110 g (nom)

velocity or displacement response

Electrical Environmental

Power Input +24 V DC (50 mA)

Output 1 0-20 mm/s rms Velocity Operating temperature range 0 to 55 ºC

(Other ranges available) Installation Category (IEC664) II

Output 2 (BNC) Buffered acceleration signal Equipment Class (IEC536) III

Relays Output 1 SPDT, 1A Form C 24Vdc EMC EN61326-1:2013

LED Statuse 4 LEDs Power, Loop, ICP, and relay

Configuration Input type Input transducer Full Scale Range

Alert Value

Output Units

Low PassFilter

High Pass Filter Output Relay

Type

I = ISO (Standard Order)

S = Factory configured

A=Acceleration

V=Velocity

D= Displacement

500A = 500 mV/g Accelerometer100A = 100 mV/g Accelerometer050A = 50 mV/g Accelerometer010A = 10 mV/g Accelerometer

100V = 100 mV/IPS Velocity Sensor500V = 500 mV/IPS Velocity Sensor

200D = 200 mV/mils Displacement008D = 8 V/mm Displacement

01 = 0-20002 = 0-10005 = 0-4010 = 0-20

01=102=203=304=405=5xx=X

A=m/s2

V= mm/s

U=µm

01K =1KHz02K = 2KHz

xxK=XK

10= 10Hz02= 2Hz

O=4-20mA(Overall value)

D=4-20 mA (Dynamic signal)

EN =EnergizedDE =De-energized

How To Order Standard order: I-A-100A-02-05-V-01K-10-O-EN

Analog

PLC/DCS Trip

Dry contact relay

Vibration Transmitter module

Raw signal to data collector or analyzer

Buffer Output

Recorder4-20mA

Transducers

Page 5: VC200-R · Rod Drop Module Signal Conditioner / Transmitter /Monitor Key Features • Displacement proximity probe • Keyphasor® signal • 4-20mA output for rod drop value •

4www.precisiontechplus.co.uk

Signal Conditioner /Transmitter /MonitorVC210-AVibration module

MechanicalInput type 100 mV/g constant current accelerometer

(Other sensitivities available) Case Material Plastic

Frequency Range 1 Hz to 10 kHz (-3dB) (Optional) Mounting DIN Rail TS35 (Top Hat)

Filter Butterworth Dimensions 134 x 99 x 22.5 mm (H x D x W)

force filter order 8-pole Connections Push in Clamp

Dynamic Range 80 db Conductor Size 0.5 to 4.0 mm

Signal Conditioner: Amplifier/integrator to obtain Weight 110 gms (nom)

Electrical EnvironmentalPower Input +24 V DC (50 mA) Operating Temperature Range 0 to 55 ºC

Output 1 0-20 mm/s rms Velocity Installation Category (IEC664) II

(other ranges available) Equipment Class (IEC536) III

Output 2 (BNC) Buffered dynamic EMC EN61326-1:2013

acceleration signal Communication Features Relays 2 SPDT, 1A Form C 24Vdc Configuration Software Vibsens-CNFG

Statues LED 3 LEDs Run/Error, Trip, Alarm Communication Protocol Modbus RTU

Communication Port RS-232

velocity or displacement response

Microprocessor Based

PLC/DCS

Configuration Software

Recorder

Vibration measurement & transmissionmodule

ICP/Charge Sensor

Trip

Alarm

Dry contact relay

4-20mA

Modbus RTU

Configuration Input type

TransducerSensitivity

Full Scale Range

Alarm Value

TripValue

Output Units

Low PassFilter

High Pass Filter Output Relay

Type

I = ISO (Standard Order)

S = Factory config-

ured

VC200R is fully configured via

Modbus protocol

A= Acceler-ation

V=Velocity

D= Displace-ment

500A = 500 mV/g Accelerometer100A = 100 mV/g Accelerometer050A = 50 mV/g Accelerometer010A = 10 mV/g Accelerometer

100V = 100 mV/IPS Velocity Sensor500V = 500 mV/IPS Velocity Sensor

200D = 200 mV/mils Displacement008D = 8 V/mm Displacement

01 = 0-1002 = 0-2005 = 0-50

xx = X

01=102=203=304=405=5xx=X

01=102=203=304=405=5xx=X

A=m/s2

V= mm/s

U=µm

01K =1KHz02K = 2KHz

xxK=XK

10= 10Hz02= 2Hz

O=4~20mA(Overall data)

D=4~20 mA (Dynamic Data)

EN =EnergizedDE =De-energized

How To Order Standard order: I-A-100A-02-02-04-V-01K-10-O-EN

Key FeaturesICP® /Voltage/Current TransducerAcceleration/Velocity/ Displacement Output 4-20 mA output for dynamic signal / overall value2 output relays fully configurable with software Buffered acceleration output ICP® transducer OK status LEDDIN Rail MountingPush-in type connectorsEnergized and De-energized relay optionDelay shutdown functionSupported Modbus RTU Protocol

Technical Specifications