Copyright © 2007 Greenheck Fan Corp. 1 Greenheck Kitchen Ventilation Systems Variable Volume Option

Transcript of Variable Volume Option -...

Page 1: Variable Volume Option - airflowspecialists.comairflowspecialists.com/pdffiles/KVS_VariableVolume'07-NoQuestions.pdf · Commercial kitchen exhaust hoods shall comply with the requirements

Copyright © 2007 Greenheck Fan Corp.1

Greenheck Kitchen Ventilation Systems

Variable Volume Option

Page 2: Variable Volume Option - airflowspecialists.comairflowspecialists.com/pdffiles/KVS_VariableVolume'07-NoQuestions.pdf · Commercial kitchen exhaust hoods shall comply with the requirements

Copyright © 2007 Greenheck Fan Corp.2

Variable Volume Kitchen Ventilation Systems

A system designed to vary the exhaust and supply volume using variable frequency drives.

Page 3: Variable Volume Option - airflowspecialists.comairflowspecialists.com/pdffiles/KVS_VariableVolume'07-NoQuestions.pdf · Commercial kitchen exhaust hoods shall comply with the requirements

Copyright © 2007 Greenheck Fan Corp.3

Optic SensorKey Pad VFDs

I/O Processor

Exhaust Collar

Temp Sensor

System Components

Page 4: Variable Volume Option - airflowspecialists.comairflowspecialists.com/pdffiles/KVS_VariableVolume'07-NoQuestions.pdf · Commercial kitchen exhaust hoods shall comply with the requirements

Copyright © 2007 Greenheck Fan Corp.4

Energy Savings Example

Constant CFM - Fan on all Day 3300 CFM100% Fan

50% Fan

30% Fan

0% Fan6 7 8 9 10 11 12 1 2 3 4 5 6 7 8 9 10 11

Represents Variable Exhaust Fan System

Operating HoursBreakfast Lunch Dinner

Page 5: Variable Volume Option - airflowspecialists.comairflowspecialists.com/pdffiles/KVS_VariableVolume'07-NoQuestions.pdf · Commercial kitchen exhaust hoods shall comply with the requirements

Copyright © 2007 Greenheck Fan Corp.5

Energy Savings Payback

• Typical paybacks average 1 to 3 years.• Air flow reduction is typically between 10% and

50%• Applications requiring heated and cooled have the

shortest payback period.

Page 6: Variable Volume Option - airflowspecialists.comairflowspecialists.com/pdffiles/KVS_VariableVolume'07-NoQuestions.pdf · Commercial kitchen exhaust hoods shall comply with the requirements

Copyright © 2007 Greenheck Fan Corp.6

Features

• Air purged optic sensor• 100% Over ride switch• Mount and pre-programmed components• System monitoring and programming at the

keypad• Built-in timer for automatic on/off capability• Automatic optic sensor calibration

Page 7: Variable Volume Option - airflowspecialists.comairflowspecialists.com/pdffiles/KVS_VariableVolume'07-NoQuestions.pdf · Commercial kitchen exhaust hoods shall comply with the requirements

Copyright © 2007 Greenheck Fan Corp.7

Benefits

• Saves energy• Prolongs equipment life• Enhances employee comfort• Reduced hood noise• Low fan maintenance• May qualify for energy rebate• “Soft-Starting” fans

Page 8: Variable Volume Option - airflowspecialists.comairflowspecialists.com/pdffiles/KVS_VariableVolume'07-NoQuestions.pdf · Commercial kitchen exhaust hoods shall comply with the requirements

Copyright © 2007 Greenheck Fan Corp.8

Options

• Comfort mode sensor• Winter set-back • Humidity sensor• IAQ sensor• Fire safety control

Page 9: Variable Volume Option - airflowspecialists.comairflowspecialists.com/pdffiles/KVS_VariableVolume'07-NoQuestions.pdf · Commercial kitchen exhaust hoods shall comply with the requirements

Copyright © 2007 Greenheck Fan Corp.9

Mechanical Code Compliance

2006 International Mechanical Code507.1 GeneralCommercial kitchen exhaust hoods shall comply with the requirements of this section. Hoods shall be Type I or Type II and shall be designed to capture and confine cooking vapor and residues.

Exceptions:Net exhaust volumes for hoods shall be permitted to be reduced during no-load cooking conditions, where engineered or listed multi-speed or variable-speed controls automatically operate the exhaust system to maintain capture and removal of cooking effluents as required by this section.

Page 10: Variable Volume Option - airflowspecialists.comairflowspecialists.com/pdffiles/KVS_VariableVolume'07-NoQuestions.pdf · Commercial kitchen exhaust hoods shall comply with the requirements

Copyright © 2007 Greenheck Fan Corp.10

NFPA-96 Compliance

• NFPA-96 2008 Edition• 8.2.1 Air Velocity• 8.2.1.1 • The air velocity through any duct shall not be • less than 152.4m/min. (500 ft/min)

Page 11: Variable Volume Option - airflowspecialists.comairflowspecialists.com/pdffiles/KVS_VariableVolume'07-NoQuestions.pdf · Commercial kitchen exhaust hoods shall comply with the requirements

Copyright © 2007 Greenheck Fan Corp.12

Number one in air movement and control.

greenheck.com

Fans and Ventilators

Energy Recovery

Ventilators & Make-Up Air

Units

Kitchen Ventilation Systems

Dampers and Louvers

Centrifugal and Vane Axial Fans

Page 12: Variable Volume Option - airflowspecialists.comairflowspecialists.com/pdffiles/KVS_VariableVolume'07-NoQuestions.pdf · Commercial kitchen exhaust hoods shall comply with the requirements

Copyright © 2007 Greenheck Fan Corp.13

The mission of Greenheck is to be the market leader in the development, manufacture and worldwide sale of quality air moving and control equipment with total commitment to customer service.