Variable Displacement Vane Pumps - · PDF filevariable displacement vane pumps ... (max. of...

8
GB-V-117 Rev. 6/97 Variable Displacement Vane Pumps VVA 10/20/40, 20 series and VVA 80, 10 series single and multiple pumps Basic Characteristics Types Single and multiple pumps . . . . . . (Multiples can include fixed displacement sections) Displacement (variable sections) 10 to 83 cm 3 /r . . . . . . Speed range 800 to 1800 r/min . . . . . . . . Max. operating pressure up to 100 bar . . General Description VVA pumps are pressure compensated variable displacement vane pumps having separate adjustments for pressure compensation and maximum displacement. Pressure compensator options include single and dual adjustable pressure designs. Modular design enables the user to build multiple pumps (max. of three pump sections) quickly from individual pump sections and adaptor kits containing all the necessary parts. Multiple pumps can contain pump sections of the VVA type only or a mix of VVA and Vickers vane pumps. Functional Symbols Single pumps VVA pump with ‘C’ compensator VVA pump with ‘CD’ compensator Multiple pumps, typical VVA double pumps with ‘CD’ and ‘C’ compensator sections Sectional Illustration Transverse section through ‘C’ compensator, 20 design example Vickers ® Vane Pumps

Transcript of Variable Displacement Vane Pumps - · PDF filevariable displacement vane pumps ... (max. of...

Page 1: Variable Displacement Vane Pumps -  · PDF filevariable displacement vane pumps ... (max. of three pump sections) quickly from individual pump ... Hydraulic fluids

GB-V-117Rev. 6/97

Variable Displacement Vane PumpsVVA 10/20/40, 20 series and VVA 80, 10 series single and multiple pumps

Basic CharacteristicsTypes Single and multiple pumps. . . . . .

(Multiples can include fixeddisplacement sections)

Displacement(variable sections) 10 to 83 cm3/r. . . . . . Speed range 800 to 1800 r/min. . . . . . . . Max. operating pressure up to 100 bar. .

General DescriptionVVA pumps are pressure compensatedvariable displacement vane pumpshaving separate adjustments for pressurecompensation and maximumdisplacement. Pressure compensatoroptions include single and dual adjustablepressure designs.

Modular design enables the user to buildmultiple pumps (max. of three pumpsections) quickly from individual pumpsections and adaptor kits containing allthe necessary parts. Multiple pumps cancontain pump sections of the VVA typeonly or a mix of VVA and Vickers vanepumps.

Functional SymbolsSingle pumps

VVA pump with‘C’ compensator

VVA pump with‘CD’ compensator

Multiple pumps, typical

VVA double pumps with ‘CD’ and ‘C’compensator sections

Sectional IllustrationTransverse section through ‘C’compensator, 20 design example

Vickers®

Vane Pumps

Page 2: Variable Displacement Vane Pumps -  · PDF filevariable displacement vane pumps ... (max. of three pump sections) quickly from individual pump ... Hydraulic fluids

2

Model Code

Mounting Port OptionCode flange ∆ type for:

R � G(BSPF) VVA10,20,40and 80

� NPT VVA10

P♦ SAE ‘B’ UNF/SAE VVA20SAE ‘C’ O-ring VVA40SAE ‘D’ VVA80

∆ 4-bolt square� See ‘Installation dimensions’ section♦ Recommended for exports to USA

and USA-influenced markets

Single pumps or VVA sections of multiple pumps.

VVA** (*) * - C(D) * * W-*0

Geometric displacement, max.

3 4 5 761 2

1

10 = 10 cm3/r 40 = 43 cm3/r20 = 19 cm3/r 80 = 83 cm3/r

2 Pump section, multiple pumps

VVA**(F)R models

F = Shaft-end section of all modelsor VVA-type center section oftriple pumps

Omit for single pumps and VVA-typerear-end sections of multiple pumps.

VVA**(*)P models

F = Shaft-end sectionM = VVA-type center section of triple

pumpsE = VVA-type rear-end section of

multiple pumpsOmit for single pumps

3 Mounting flange/port typecombinations

4 Control Type

C = Pressure compensatorCD = Dual pressure compensator

5 Pressure compensatoradjustment ranges

For VVA 10, 20 and 40 pumpsA = 12-25 barB = 20-40 barC = 30-63 barD = 50-100 barFor VVA 80 pumpsA = 10-35 barB = 20-70 bar

6 Pressure compensatoradjustment method

W = Screw with locknutK = Micrometer knob with keylock

(Option for type C compensatorsonly)

7

20 series for VVA 10, 20 and 40 models10 series for VVA 80 modelsSubject to change. Installationdimenstions remain unaltered for designnumbers *0 to *9 inclusive.

Design number

Multiple pumps, completeSee ‘Multiple pumps’ section.

Operating Data

� Pressure, displacement and speedlimits

Pressure limits

Variable displacement pump orsectionsInlet port –0,2 bar to + 1,0 bar. . . . . . . . Outlet port:VVA 10/20/40 100 bar max. contin.. . . . VVA 80 70 bar max. contin.. . . . . . . . . . Pilot pressure port (‘CD’ compensators):VVA 10/20/40 100 bar max. contin.. . . . VVA 80 70 bar max. contin.. . . . . . . . . . Drain port 1,0 bar max.. . . . . . . . . . . . . .

Fixed displacement section(s) ofmultiple pumpsSee leaflet of appropriate pump as listedin the ‘Multiple pumps’ section.Note that max. pressure for an applicationmay be limited by the torque capacity ofthe variable pump section(s); see ‘Driveshaft rotation and load limits’ section onnext page.

Geometric displacementFor variable pumps and sections, see‘Model code’ above. For any fixeddisplacement sections of multiple pumps,refer to ‘Technical information’ leafletV-108.

Speed limitsAll models 800 to 1800 r/min.. . . . . . . . .

� Performance dataTypical characteristics at 1450 r/min,50�C oil temperature, 24 cSt oil viscosity.

� Control dataFor variable displacement pumps orsections.

Pressure compensator, ‘C’ typeTypical flow/pressure characteristicsshown by performance curves onprevious page. Choice of adjustablepressure ranges defined in model codeabove.

Dual pressure compensator, ‘CD’ typeTwo separately-adjustable pressuresettings can be selected by remotecontrol. Suitable controls are DG4V-3solenoid operated, DG17V-3 hand leveroperated or DG20V-3 cam lever operateddirectional control valves (For details see‘Directional controls’ leaflet V-637 forDG4V-3 valves or V-623 for DG17V andDG20V-3 valves). The remote controlshould be applied as in the followingexample:

Compensator pilot port

Remote control valve

Page 3: Variable Displacement Vane Pumps -  · PDF filevariable displacement vane pumps ... (max. of three pump sections) quickly from individual pump ... Hydraulic fluids

3

Operating Data

Fixed displacement sections of multiple pumps:see appropriate leaflet, listed in ‘Multiple pumps’section

20

15

10

5

0

2

3

4

1

020100 30 40 50 60 70 80 90 100

VVA 10

Effe

ctiv

e flo

w r

ate

(l/m

in)

Sha

ft in

put p

ower

(kW

)

10

80

60

40

20

0

10

15

20

5

0200 30 40 50 60 70 80 90 100

VVA 40

Effe

ctiv

e flo

w r

ate

(l/m

in)

Sha

ft in

put p

ower

(kW

)

10 200 30 40 50 60 70 80 90 100

VVA 20

VVA 80

6

9

3

0

Sha

ft in

put p

ower

(kW

)

30

20

10

0

Effe

ctiv

e flo

w r

ate

(l/m

in)

10 200 30 40 50 60 70

60

40

20

0

120

100

80E

ffect

ive

flow

rat

e (l/

min

)

15

12

6

4

2

0

Sha

ft in

put p

ower

(kW

)

Pressure (bar)

Pressure (bar)

Pressure (bar)

Pressure (bar)

A low pressure setting is obtained whenthe compensator pilot port is drained toreservoir. Conversely, a high setting isobtained when pump outlet pressure isconnected to the pilot port. Instructionsfor adjusting the pressure settings aregiven on page 4.

� Hydraulic fluidsAntiwear hydraulic coils in accordancewith ‘Technical information’ leaflet B-920.

Maximum viscosity at startingFull displacement 800 cSt. . . . . . . . . . . . Zero displacement 200 cSt. . . . . . . . . . .

Running viscosity rangeVariable displacement singleand multiple pumps 16 to 160 cSt. . . . . . Multiple pumps that includeGPA model fixed displacementsection(s) 30 to 45 cSt. . . . . . . . . . . . . . . Multiple pumps that includea V10 model fixed displacementsection 16 to 54 cSt. . . . . . . . . . . . . . . . . .

� Temperature limitsAmbient and operating temperature . . . .

–10�C to + 70�C. . . . . . . . . . . . . . . . . . . .

� Filtration requirements25 µm absolute or finer

� Drive shaft rotation and load limits

Direction of rotationSingle pumps and all multiple pumps areavailable for clockwise rotation only,viewed at the shaft end.

Torque limits

Single and double pumpsNo special check required.

Triple pumpsThose comprised of three VVA sectionsrequire no special check, but for all otherscheck that shaft loadings for eachapplication do not exceed the limits in thefollowing table where:p1, p2 and p3 = Max. pressure (bar)

of section (referencedfrom shaft end) for theapplication.

V1, V2 and V3 = Max. displacement(cm3/r) of section(referenced from theshaft end) for theapplication.

ShaftCheck that

Shaftendpumpmodel

p1 V1 +p2 V2 + p3 V3

p2 V2 + p3 V3

VVA 10 � 3000bar cm3/r

� 2000bar cm3/r

VVA 20 � 5700bar cm3/r

� 3800bar cm3/r

VVA 40 � 12900bar cm3/r

� 8600bar cm3/r

Drive arrangementDirect drive through a flexible coupling ispreferred. If an indirect drive and/or oneimposing axial loading is envisaged,please consult your Vickersrepresentative.

Page 4: Variable Displacement Vane Pumps -  · PDF filevariable displacement vane pumps ... (max. of three pump sections) quickly from individual pump ... Hydraulic fluids

4

Installation Dimensions, Single Pumps

N

– High pressure settingWith pump outlet pressure applied atcompensator pilot port, turn locknut#2 anticlockwise to increase, orclockwise to decrease pressuresetting.

Caution – This setting must notexceed the maximum for theappropriate range as listed underin the ‘Model Code’ section.

Type ‘C’ compensator adjustment

Slacken locknut or turn key (asappropriate) anticlockwise to unlock.Turn adjusting screw clockwise toincrease or anticlockwise to decreasepressure setting. Re-tighten lockingdevice.

Type ‘CD’ compensator adjustment– Low pressure

With pilot port drained to reservoir,adjust low pressure setting as fortype ‘C’ compensator

VVA single pumps

5

Drain

InletA

UT

S

B CDE

f

MZ

R c

G H

F L

VX1

h

P

OQ

Inlet

Outlet

g max. 25

XK

e

b

YW

Jd

18 toremovekey(Type ‘C’ compensator with

micrometer adjustment option.)

a

Type ‘C’ pressurecompensator s

Locknut AdjustingScrew

Locknut #1

AdjustingScrew

Locknut #2

Type ‘CD’pressure

compensator s

1st angleprojection

mm (unless otherwise indicated)

s

A a B b C c D d E e F f

VVA 10(F)RVVA 20(F)RVVA 40(F)RVVA 80(F)R

20253336

100�0,2125�0,2160�0,2200�0,2

15151620

6.h96.h9

10.h910.h9

1111

20,521,535,341,3

G1/4″G1/4″G3/8″G1/2″

G1/8″G1/8″G1/8″G1/8″

24243034

9111418

34,534,56875

20253321

VVA 10(*)P 20 100�0,2 15 3,193,15

1 20,6 1/4″NPT

1/8″NPT

24 9 34,5 15,5

VVA 20(*)P 25 127�0,2 15 3,203,17

1 20,6 7/16″-20

UNF-2B1/8″NPT

24 11 34,5 20

VVA 40(*)P 33 161,9�0,2 16 6,386,35

1 34,6 9/16″-18

UNF-2B1/8″NPT

30 14 68 27

VVA 80(*)P 36 228,5�0,2 20 9,559,52

1 42,3 3/4″-10

UNF-2B1/8″NPT

34 20 68 22

G g H h J K L M N O P Q

VVA 10(F)RVVA 20(F)RVVA 40(F)RVVA 80(F)R

28285858

256271326428

2,52,567

81012–

697696

125

95110150200

G3/8″G1/2″G1″G11/4″

G1/2″G3/4″G11/4″G11/2″

15162025

16202227

586583

100

47,55575

100

VVA 10(*)P 28 256 2,5 8 69 95 3/8″NPT

1/2″NPT

15 16 58 47,5

VVA 20(*)P 28 271 2,5 10 76 110 3/4″-16UNF-2B

11/16″-12UNF-2B

16 20 65 55

Page 5: Variable Displacement Vane Pumps -  · PDF filevariable displacement vane pumps ... (max. of three pump sections) quickly from individual pump ... Hydraulic fluids

5

VVA 40(*)P 58 326 6 12 96 150 15/16″-12UNF-2B

17/8″-12UNF-2B

20 22 83 75

VVA 80(*)P 58 428 1 – 125 200 15/8″-12UNF-2B

17/8″-12UNF-2B

22 25 100 100

Page 6: Variable Displacement Vane Pumps -  · PDF filevariable displacement vane pumps ... (max. of three pump sections) quickly from individual pump ... Hydraulic fluids

6

Installation Dimensions, Single Pumps

R S T U V W X Y Z X1

VVA 10(F)RVVA 20(F)RVVA 40(F)RVVA 80(F)R

80.h8100.h8125.h8160.h8

18.k619.k632.k638.k6

444

10

9111418

20253335

239259326430

227243298390

113126170240

141170254250

53689197

VVA 10(*)P 80.h8 19,04819,035

4 9 20 239 227 113 141 53

VVA 20(*)P 101,60101,55

19,0519,02

4 11 25 259 243 126 170 68

VVA 40(*)P 127,00126,95

31,7531,70

4 14 33 326 298 170 254 91

VVA 80(*)P 152,40152,35

38,1038,05

9 18 36 430 390 240 250 97

Installation Dimensions, Multiple Pumps

Comprising pump sections and adapterkit(s) to be ordered as (and supplied as)separate items for assembly by the user.Approved combinations are shown belowfollowed by information about possiblenon-VVA pump sections, a list of adapterkits and assembly information.

For triple pumps, check that the max.torque resulting from the proposedapplication will not exceed that defined inthe ‘Drive Shaft Rotation and TorqueLimits’ section.

Basic modelDimensions

Pump combinationBasic modelcombination A B C D E F

AC

E∆∆ D

VVA 10/VVA 10VVA 20/VVA 10VVA 20/VVA 20VVA 40/VVA 10VVA 40/VVA 20VVA 40/VVA 40VVA 80/VVA 10VVA 80/VVA 20VVA 80/VVA 40VVA 80/VVA 80

165,5197195258256292,5258,5256,5292298,5

272303,5330,5364,5391,5478,5365392478478,5

20252533333335353535

185,5217220278281325,5278,5281,5325333,5

F∆E∆

∆ D

C

B

A

VVA 10/VVA 10/VVA 10VVA 20/VVA 10/VVA 10VVA 20/VVA 20/VVA 10VVA 20/VVA 20/VVA 20VVA 40/VVA 10/VVA 10VVA 40/VVA 20/VVA 10VVA 40/VVA 20/VVA 20VVA 40/VVA 40/VVA 10VVA 40/VVA 40/VVA 20VVA 40/VVA 40/VVA 40VVA 80/VVA 10/VVA 10VVA 80/VVA 20/VVA 10VVA 80/VVA 20/VVA 20VVA 80/VVA 40/VVA 10VVA 80/VVA 40/VVA 20VVA 80/VVA 40/VVA 40VVA 80/VVA 80/VVA 10VVA 80/VVA 80/VVA 20VVA 80/VVA 80/VVA 40VVA 80/VVA 80/VVA 80

165,5197195195258256256292,5292,5292,5258,5256,5256,5292292292298,5298,5298,5298,5

331362,5392390423,5453451550,5548,5585424453,5451,5550548584,5557555590,5597

437,5469498,5525,5530559,5586,5656,5684771530,5560587656,5683,5770,5663,5690,5776,5777

2025252533333333333335353535353535353535

185,5217220220278281281325,5325,5325,5278,5281,5281,5325325333,5333,5333,5333,5333,5

351382,5412415443,5473476570,5573,5618444473,5476,5570573617,5577580623,5632

Page 7: Variable Displacement Vane Pumps -  · PDF filevariable displacement vane pumps ... (max. of three pump sections) quickly from individual pump ... Hydraulic fluids

7

Installation Dimensions, Multiple Pumps

Basic modelDimensions

Pump combinationBasic modelcombination A B C D E F

CA

∆ D 2424.6

VVA 10/V 10VVA 20/V 10VVA 40/V 10

172,5205266

299,5�332 �

393 �

202533

AB

C

∆ DE 2424.6

VVA 10/VVA 10/VVA 10VVA 20/VVA 10/VVA 10VVA 20/VVA 20/VVA 10VVA 40/VVA 10/VVA10VVA 40/VVA 20/VVA10VVA 40/VVA 40/VVA10

165,5197195258256292,5

338369,5400430,5461558,5

465496,5527557,5588685,5

202525333333

185,5217220278281325,5

� Maximum. Can be less, dependent on the displacement sizes of the sections.D Stated values apply to VVA**(F)R models.

Non-VVA pump sectionsRefer to the following table for details ofpossible fixed displacement pumps.

Displacement(cm3/r) persection

Max.pressure(bar)

Model seriesand type

Technicalinformationleaflet

6,5 to 16,4 155V10 vane pumps, singlemodels V-108

Adapter kits

Pumps sectioncombination Kit model

VVA 10 + V 10VVA 10 + VVA 10VVA 20 + V 10VVA 20 + VVA 10VVA 20 + VVA 20VVA 40 + V 10VVA 40 + VVA 10VVA 40 + VVA 20VVA 40 + VVA 40VVA 80 + VVA 10VVA 80 + VVA 20VVA 80 + VVA 40VVA 80 + VVA 80

AK-VVA 10/V 10AK-VVA 10/10AK-VVA 20/V 10AK-VVA 20/10AK-VVA 20/20AK-VVA 40/V 10AK-VVA 40/10AK-VVA 40/20AK-VVA 40/40AK-VVA 80/10AK-VVA 80/20AK-VVA 80/40AK-VVA 80/80

Example:

For a VVA 40/VVA 20/V 10 combination,two adapter kits are required:

1 of AK-VVA 40/201 of AK-VVA 20/V 10

Page 8: Variable Displacement Vane Pumps -  · PDF filevariable displacement vane pumps ... (max. of three pump sections) quickly from individual pump ... Hydraulic fluids

8

Assembly of Multiple Pumps

Bolt torque, lubricated

Bolt size Torque (Nm)

M6 13 – 15M8 31 – 37M10 59 – 73M12 103 – 127M16 257 – 315

�Not used for following pump combinationsVVA 20/VVA 20VVA 20/V 10VVA 40/VVA 20VVA 40/V 10

Front orcenter pumpsection

O-ring

Bolt

Coupling

Separator �(included incoupling)

Adapter

Bolt

O-ringRearpumpsection

Mass Approx.Single pumps, sections and adapterkits:VVA 10*R/P 5,6 kg. . . . . . . . . . . . . . . . . VVA 10R/P 5,7 kg. . . . . . . . . . . . . . . . . . VVA 20*R/P 9,6 kg. . . . . . . . . . . . . . . . . VVA 20R/P 9,9 kg. . . . . . . . . . . . . . . . . . VVA 40*R/P 23,8 kg. . . . . . . . . . . . . . . . VVA 40R/P 23,2 kg. . . . . . . . . . . . . . . . . VVA 80*R/P 37,8 kg. . . . . . . . . . . . . . . . VVA 80R/P 37,4 kg. . . . . . . . . . . . . . . . . Non-VVA pump sections See leaflets. .

listed on previous page. . . . . . . . . . . . . . AK-VVA 10/V 10 1,0 kg. . . . . . . . . . . . . AK-VVA 10/10 1,0 kg. . . . . . . . . . . . . . . AK-VVA 20/V 10 1,1 kg. . . . . . . . . . . . . AK-VVA 20/10 1,1 kg. . . . . . . . . . . . . . . AK-VVA 20/20 1,1 kg. . . . . . . . . . . . . . . AK-VVA 40/V 10 2,0 kg. . . . . . . . . . . . . AK-VVA 40/10 2,0 kg. . . . . . . . . . . . . . . AK-VVA 40/20 2,0 kg. . . . . . . . . . . . . . . AK-VVA 40/40 3,7 kg. . . . . . . . . . . . . . . AK-VVA 80/10 3,5 kg. . . . . . . . . . . . . . . AK-VVA 80/20 3,7 kg. . . . . . . . . . . . . . . AK-VVA 80/40 5,0 kg. . . . . . . . . . . . . . . AK-VVA 80/80 6,0 kg. . . . . . . . . . . . . . .

Multiple pumps:Total masses of relevant pump sectionsand adapter kit(s).

Mounting AttitudeOptional

Ordering ProcedureSpecify quantities and full modeldesignations of all items required. In thecase of multiple pump sections andadapter kits e.g. for two typicalVVA 20/VVA 10/V 10 combinations:

2 of VVA 20FR-CBWW-20 pump2 of VVA 10FR-CBWW-20 pump2 of V 10-IB5B-1A-20 pump2 of AK-VVA 20/10 adapter kit2 of AK-VVA 10/V 10 adapter kit