13jun131
Operator TrainingMCM-400
12 June 2013 Stefaan Verkest – version 00
Agenda
1. Key features of the product
2. Identification of main parts
3. Powering the system on/off
4. Connections
5. On Screen Display (OSD) or ‘Menu’
6. Basic operations
7. Maintenance
8. Limitations and restrictions
9. Diagnostics
10.List of available documentation
11.Who to contact in case of problems
MCM-4002
13jun132
Key features of the product (1)
Image processing box Dedicated to Galaxy 4K series projector (and only to this one)
Designed for single and multi-projector V&AR display systems▫ Geometry correction (Warping)
▫ Color alignment (Dynacolor)
▫ Edge blending (Soft edge)
▫ Image correction on a pixel-by-pixel base (Alpha/Beta planes)
Passive stereo Output can run synchronously with selected input Controlled via RCU (IR)
MCM-4003
Key features of the product (2)
Very suitabe in▫ Corporations: multi channel collaboration rooms, flat and
curved screens
▫ Automotive, Oil & Gas, Scientific research:3D visualization
▫ Command and control displays: high resolution
MCM-4004
13jun133
Key features of the product (3)
MCM-400 makes a perfect match with Galaxy 4K, because:▫ MCM-400 converts source timings to fit Galaxy 4K input requirements
- Wider range of source signals
- Easy and cheaper preview
- 4 quadrant input (2x2) possible instead of 2x1
▫ EDID can be easily customized in MCM-400
▫ MCM-400 allows for much easier alignment (which makes it indispensable in case of multiple channel displays):- Geometry
- Colors
- Soft edge
▫ MCM-400 can be used as mini switcher (e.g. 4K mono source – 2K stereo source)
▫ MCM-400 allows image correction on a pixel-by-pixel basis
MCM-4005
Identification of the main parts (1)
MCM-4006
Diagnostic LEDsDiagnostic LEDs
Mount plateMount plate
IR receiverIR receiver
13jun134
Identification of the main parts (2)
MCM-4007
Description
1 Power IN
2 Fuse
3 R&D ports
4 IR receiver
5 Network
6 Not used
7 Not used
8 Not used
9 Source inputs
10 Output 1
11 Output 2
Identification of the main parts (3)
MCM-4008
Power supplyPower supply
Remote Control UnitRemote Control Unit
Power cordPower cord
13jun135
Powering the system ON and OFF (1)
Powering ON1. Connect the power supply
to the MCM-400
2. Connet the power cord to the power supply
3. Connect the power cord to the wall outlet.
4. Wait for the unit to come to active mode (ON).
MCM-4009
Powering the system ON and OFF (2)
Switching OFFi.e. switching from Active mode to Standby mode
1. In Active mode, press the on/off key for 3 seconds.
2. The “ON” LED turns off and the “STANDBY” LED turns on.
MCM-40010
13jun136
Powering the system ON and OFF (3)
Switching ONi.e. switching from Standby mode to Active mode
1. In Standby mode, press the on/off key for 1 second.
2. The “STANDBY” LED turns off and the “ON” LED turns on.
MCM-40011
Powering the system ON and OFF (4)
Powering OFF1. Switch off the MCM-400
2. Disconnect the power cord from the wall outlet.
MCM-40012
13jun137
Connections
Additional information▫ DVI connectors do not
support analog signals
▫ SL-DVI and DL-DVI available at input side
▫ DVI out timings are designed to match Galaxy 4K input requirements
MCM-40013
On Screen Display (OSD) or ‘Menu’ (1)
In the ‘Menu’▫ “<Main menu item>”: press the down
arrow key on the RCU to open the drop down menu (e.g. Installation)
▫ “<Text>...” :a new dialog box or edit box opens when selecting and confirming this item (e.g. IR address...)
▫ “<Text>►”: press the right arrow key on the RCU to open the drop down menu (e.g. Edid ►)
MCM-40014
IR address...
13jun138
On Screen Display (OSD) or ‘Menu’ (2)
In edit boxes of the ‘Menu’▫ Select the edit field and confirm
▫ Use arrow keys ◄ and ►to select the character to be changed
▫ Use arrow keys ▲ and ▼ to change the selected character, orUse the keys 0..9 to enter a digit
MCM-40015
Basic operations (1)
MCM-40016
Setting the RCU address▫ Common MCM-400 IR
address is “0” by default
Setting the MCM-400 IR address IR address...
13jun139
Basic operations (2)
MCM-40017
Connecting to Galaxy 4K: make sure to know the hostname or IP address of the Galaxy 4K to which the MCM-400 is connected.
IR address...
Basic operations (3)
MCM-40018
Selecting a source via “Source selection” (single source)
Selecting sources (single source or stitched layout) via “Window files” (advised)
13jun1310
Basic operations (4)
MCM-40019
Switching from mono to passive stereo (and vice versa)
Basic operations (5)
MCM-40020
Freeze - Unfreeze
13jun1311
Basic operations (6)
MCM-40021
Image settings: do not change in multi-channel systems!
Basic operations (7)
MCM-40022
Enabling defined color correction (Dynacolor)▫ Enabling Dynacolor only makes sense if colors have been
calibrated and/or aligned during installation
▫ In multi channel systems, Dynacolor should always be enabled!
13jun1312
Maintenance (1)
First use▫ Check device and cables on damage
Weekly maintenance▫ Check device and cables on damage: repair or replace
damaged items
▫ Display test patterns and check the projected image
MCM-40023
Maintenance (2)
Monthly maintenance▫ Vacuum clean air inlet grids in dusty environment
Yearly maintenance▫ Clean the device
MCM-40024
13jun1313
Maintenance (3)
MCM-40025
Condition based maintenance▫ Make a backup each time settings are changed
▫ Upgrade the firmware if needed
▫ Replace the batteries of the RCU
Limitations and restrictions
10°C – 50°F < Operational temperature < 40°C – 104°F
MCM-40026
13jun1314
Diagnostics
Diagnostic LEDs
MCM-40027
LED/ status Nopower
Standby mode Configuring Active mode IR activity
Hardware error
STANDBY (red) OFF ON ON OFF NA NA
ON (green) OFF OFF ON ON NA NA
ERROR (red) OFF OFF OFF OFF NA ON
IR (green) OFF ON (network ok)OFF (no network)
ON ON (network ok)OFF (no network)
BLINKING NA
List of available documentation
Basic user
▫ User guide: R5905191
▫ Safety manual: R5905189
▫ WEEE Recycling passport: R5905545
Advanced user / administrator▫ API command set:
R5905498
MCM-40028
13jun1315
Who to contact in case of problems (1)
First line help:
▫ Contact a certified MCM-400 specialist in your company
Escalation flow:
▫ Contact your local Barco Partner or Integrator
▫ Contact Barco support:www.barco.com Training & Support > Support
MCM-40029
Who to contact in case of problems (2)
Make sure to have the following information available:
▫ Device identification
▫ Diagnostics information
MCM-40030
13jun1316
Who to contact in case of problems (3)
Make sure to have the following information available:
▫ Window (file) information
MCM-40031
www.twitter.com/Barco
www.facebook.com/Barco
www.youtube.com/BarcoTV