Series TDA-V
Features For commercial and industrial applications where large
volumes of air are required at moderate to high pressure,
special designed integral straightening vanes, reduced
turbulence, provide high performance and low sound level.
Construction Double flanged casing is produced in mild steel or
galvanised Steel, the impeller having manually adjustable
pitch aerofoil blades is made of PPG, PAG or Aluminium.
FinishAvailable in standard finishes of galvanisation or painting.
Operating Temperature
-20°C to + 55°C Motors Totally enclosed Class ‘F’ motor, to a min. IP54 protection
are fitted as standard. Standard motor up to 2.2kW are
usually supplied on DOL starting, motor 3.0kW and above
are star/delta starting.
Airflow DirectionAir flowing from impeller to motor is fitted as standard.
DIRECT DRIVEN
MODEL: TDA 315-V / 12AA / 5-5 /__/_
Airflow direction – B
Blade angle - 20°, 22°, 24°, 26°, 28°, 30°,
32°, 34°, 36°, 38°, 40°, 42°, 44°
- __/__
Motor no. of pole – 2 or 4
Motor Power kW
8° x Ø10
Ø3
15
355
Ø3
55
Ø3
95
* All Dimension in mm
Kruger* certies that the TDA 315 -V shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certied Ratings Program.*Kruger Ventilation Industries Asia Co., Ltd
*Kruvent Industries (M) Sdn. Bhd
*Kruger Ventilation (Taiwan) Co., Ltd *Guangzhou Kruger Ventilation Co., Ltd
*Kruger Ventilation Industries (Vietnam) Co., Ltd*Kruger Ventilation Industries (India) Pvt. Ltd*Kruger Ventilation Industries (North India) Pvt. Ltd*Kruger Ventilation Industries (Thailand) Co., Ltd
*P.T. Kruger Ventilation Indonesia*Shanghai Kruger Ventilation Co., Ltd *Wuhan Kruger Ventilation Co., Ltd
1
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).
- Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation
type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings applies to air performance only. dBA levels are not licensed by AMCA international.
0
20
40
60
80
100
120
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7
To
tal P
ressu
re (
Pa)
0.00
0.02
0.04
0.06
0.08
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 1 2 3 4 5 6 7 8
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
44°
20°22° 24°
26°28°
30°32°
34°36°
38°40°
42°
42°40°38°
36°34°
26°
32°30°
28°24°
22°20°
44°
44°
22° 24° 26°20°
28° 30°32° 34° 36°38°40°42°
56
58
58
60
58
59
60
61
61
62
61
64
64
62
62
62
62
63
63
60
TDA 315-V / 12AA/ 5-5/ _ _ / _1450rpm - 50Hz
2
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).
- Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation
type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
300
350
400
450
500
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
To
tal P
ressu
re (
Pa)
0.0
0.2
0.4
0.6
0.8
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12 14 16
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
44°
20° 22° 24° 26°28°
30°32°
34°36°
38°40°
42°
42°40°38°36°34°
26°
32°30°28°
24°22°20°
44°
44°
22° 24°26°
20°
28° 30° 32°34° 36°38°40°42°
73
75
75
77
75
76
77
78
78
79
78
81
81
79
78
79
79
80
80
TDA 315-V / 12AA/ 5-5/ _ _ / _2850rpm - 50Hz
3
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).
- Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation
type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings applies to air performance only. dBA levels are not licensed by AMCA international.
0
20
40
60
80
100
120
140
160
180
200
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
To
tal P
ressu
re (
Pa)
0.00
0.03
0.06
0.09
0.12
0.15
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
44°
20° 22° 24°26°
28°30°
32°34°
36°38°
40°42°
42°40°
3836°34°
26°
32°30°
28°24°
22°20°
44°
44°
22° 24°26°
20°
28°30° 32° 34° 36°
38°40°42°
0 2 4 6 8 10
61
63
63
65
63
64
65
66
66
67
66
69
69
67
67
67
67
68
65
68
TDA 315-V / 12AA/ 5-5/ _ _ / _1750rpm - 60Hz
4
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).
- Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation
type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings applies to air performance only. dBA levels are not licensed by AMCA international.
0
100
200
300
400
500
600
700
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
To
tal P
ressu
re (
Pa)
0.0
0.2
0.4
0.6
0.8
1.0
1.2
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12 14 16 18 20
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
44°
20° 22°24° 26°
28°30°
32°34°
36°38°
40°42°
42°40°38°
36°34°
26°
32°30°28°
24°22°20°
44°
44°
22° 24° 26°20°
28° 30° 32° 34° 36°38°40° 42°
77
79
79
81
79
80
81
82
82
83
83
85
85
83
83
83
83
84
84
TDA 315-V / 12AA/ 5-5/ _ _ / _3450rpm - 60Hz
5
Series TDA-V
Features For commercial and industrial applications where large
volumes of air are required at moderate to high pressure,
special designed integral straightening vanes, reduced
turbulence, provide high performance and low sound level.
Construction Double flanged casing is produced in mild steel or
galvanised Steel, the impeller having manually adjustable
pitch aerofoil blades is made of PPG, PAG or Aluminium.
FinishAvailable in standard finishes of galvanisation or painting.
Operating Temperature
-20°C to + 55°C Motors Totally enclosed Class ‘F’ motor, to a min. IP54 protection
are fitted as standard. Standard motor up to 2.2kW are
usually supplied on DOL starting, motor 3.0kW and above
are star/delta starting.
Airflow DirectionAir flowing from impeller to motor is fitted as standard.
DIRECT DRIVEN
MODEL: TDA 355-V / 12AA / 5-5 /__/_
Airflow direction – B
Blade angle - 24°, 26°, 28°, 30°, 32°, 34°,
36°, 38°, 40°, 42°, 44°
- __/__
Motor no. of pole – 2 or 4
Motor Power kW
355
Ø3
55
Ø3
95
Ø4
35
8° x Ø10
* All Dimension in mm
Kruger* certies that the TDA 355 -V shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certied Ratings Program.*Kruger Ventilation Industries Asia Co., Ltd
*Kruger Ventilation (Taiwan) Co., Ltd *Guangzhou Kruger Ventilation Co., Ltd
*Kruger Ventilation Industries (Vietnam) Co., Ltd*Kruger Ventilation Industries (India) Pvt. Ltd*Kruger Ventilation Industries (North India) Pvt. Ltd*Kruger Ventilation Industries (Thailand) Co., Ltd
*P.T. Kruger Ventilation Indonesia*Shanghai Kruger Ventilation Co., Ltd *Wuhan Kruger Ventilation Co., Ltd
*Kruvent Industries (M) Sdn. Bhd
6
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
0
20
40
60
80
100
120
140
160
0.0 0.2 0.4 0.6 0.8 1.0
To
tal P
ressu
re (
Pa)
0.00
0.05
0.10
0.15
0.20
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
44°
24°26°
28°30°
32°34°
36°38°
40°42°
42°40°38°36°34°
26
32°30°
28°
24°
44°
44°
24° 26° 28°30° 32°
34° 36° 38° 40°42°
61
63
64
64
67
68
68
64
65
64
65
66
66
65
65
66
66
67
68
0 2 4 6 8 10
TDA 355-V / 12AA/ 5-5/ _ _ / _1450rpm - 50Hz
7
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
100
200
300
400
500
600
700
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
To
tal P
ressu
re (
Pa)
0.0
0.3
0.6
0.9
1.2
1.5
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 5 10 15 20
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
44°
24°26°
28°30°
32°34°
36°38°
40°42°
42°40°38°36°34°
26°
32°30°
28°
24°
44°
24° 26°
44
28°30° 32°
34° 36° 38° 40°42°
78
80
81
81
81
82
81
83
83
82
82
84
85
85
83
83
8482
85
TDA 355-V / 12AA/ 5-5/ _ _ / _2850rpm - 50Hz
8
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
20
40
60
80
100
120
140
160
180
200
220
240
260
0.0 0.2 0.4 0.6 0.8 1.0 1.2
To
tal P
ressu
re (
Pa)
0.00
0.05
0.10
0.15
0.20
0.25
0.30
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
44°
2426°
28°30°
32°34°
36°38°
40°42°
42°40°38°36°34°
26°
32°30°
28°
44°
44°
24° 26° 28° 30° 32°34°36°
38° 40°42°
0 2 4 6 8 10 12
72
73
73
69
66
68
69
69
70
69
70
71
71
70
70
71
73
72
71
24°
TDA 355-V / 12AA/ 5-5/ _ _ / _1750rpm - 60Hz
9
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
0
100
200
300
400
500
600
700
800
900
1000
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4
To
tal P
ressu
re (
Pa)
0.0
0.4
0.8
1.2
1.6
2.0
2.4
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 5 10 15 20
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
44°
24°26°
28°30°
32°34°
36°38°
40°42°
42°40°38°36
34°
26°
32°30°
28°
24°
44°
44°
24° 26°28° 30° 32°
34° 36° 38° 40° 42°
82
84
85
85
85
86
85
87
86
87
86
87
87
88
89
88
89
89
86
TDA 355-V / 12AA/ 5-5/ _ _ / _3450rpm - 60Hz
10
Series TDA-V
Features For commercial and industrial applications where large
volumes of air are required at moderate to high pressure,
special designed integral straightening vanes, reduced
turbulence, provide high performance and low sound level.
Construction Double flanged casing is produced in mild steel or
galvanised Steel, the impeller having manually adjustable
pitch aerofoil blades is made of PPG, PAG or pressure-
casted Aluminium.
FinishAvailable in standard finishes of galvanisation or painting.
Operating Temperature
-20°C to + 55°C Motors Totally enclosed Class ‘F’ motor, to a min. IP54 protection
are fitted as standard. Standard motor up to 2.2kW are
usually supplied on DOL starting, motor 3.0kW and above
are star/delta starting.
Airflow DirectionAir flowing from impeller to motor is fitted as standard.
DIRECT DRIVEN
MODEL: TDA 400-V / 12AA / 5-5 /__/_
Airflow direction – B
Blade angle - 18°, 20°, 22°, 24°, 26°, 28°, 30°,
32°, 34°, 36°, 38°, 40°, 42°
- __/__
Motor no. of pole – 2, 4 or 6
Motor Power kW
12° x Ø10355
Ø4
00
Ø4
40
Ø4
80
* All Dimension in mm
Kruger* certies that the TDA 400 -V shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certied Ratings Program.*Kruger Ventilation Industries Asia Co., Ltd
*Kruger Ventilation (Taiwan) Co., Ltd *Kruger Ventilation Industries (Vietnam) Co., Ltd*Kruger Ventilation Industries (India) Pvt. Ltd*Kruger Ventilation Industries (North India) Pvt. Ltd*Kruger Ventilation Industries (Thailand) Co., Ltd
*P.T. Kruger Ventilation Indonesia*Shanghai Kruger Ventilation Co., Ltd *Wuhan Kruger Ventilation Co., Ltd
*Kruvent Industries (M) Sdn. Bhd
*Guangzhou Kruger Ventilation Co., Ltd
11
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (KW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
10
20
30
40
50
60
70
80
90
100
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
To
tal P
ressu
re (
Pa)
0.00
0.02
0.04
0.06
0.08
0.10
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 1 2 3 4 5 6 7
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
34°36°
38°40°
42°
42°40°
38°36°
34°
26°
32°
30°
28°
24°22°
20°18°
18° 22° 24° 26°20° 28° 30° 32° 34° 36° 38° 40° 42°
61
61
65
65
62
62
62
68
67
67
68
71
71
69
71
67
67
68
69
TDA 400-V / 12AA/ 5-5/ _ _ / _950rpm - 50Hz
12
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (KW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
To
tal
Pre
ssu
re (
Pa)
0.0
0.1
0.2
0.3
0.4
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
34°36°
38°40°
42°
42°40°
38°36°
34°
26°
32°30°
28°
24°22°
20°18°
18° 22° 24° 26°20° 28° 30° 32° 34° 36° 38° 40° 42°
72
72
77
78
73
73
73
79
79
78
79
83
83
81
73
78
78
79
80
TDA 400-V / 12AA/ 5-5/ _ _ / _1450rpm - 50Hz
13
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (KW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
100
200
300
400
500
600
700
800
900
0.0 0.5 1.0 1.5 2.0 2.5 3.0
To
tal P
ressu
re (
Pa)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.5 1.0 1.5 2.0 2.5 3.0
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 5 10 15 20
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18° 20°22° 24°
26°28°
30°32°
34°36°
38°40°
42°
42°40°
38°36°
34°
26°
32°
30°
28°
24°22°
20°18°
18° 22° 24° 26°20° 28° 30° 32° 34°36° 38° 40° 42°
89
89
94
99
90
90
91
97
97
96
97
102
102
99
100
96
96
96
97
TDA 400-V / 12AA/ 5-5/ _ _ / _2850rpm - 50Hz
14
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (KW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
20
40
60
80
100
120
140
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3
To
tal P
ressu
re (
Pa)
0.00
0.05
0.10
0.15
0.20
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0 1.1 1.2 1.3
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
34°36°
38°40°
42°
42°40°
38°36°
34°
26°
32°
30°
28°
24°22°
20°18°
18° 22° 24° 26°20° 28° 30° 32° 34° 36° 38° 40°
42°
66
66
71
71
67
67
67
73
72
72
73
77
76
75
76
72
72
73
74
TDA 400-V / 12AA/ 5-5/ _ _ / _1150rpm - 60Hz
15
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (KW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
40
80
120
160
200
240
280
320
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
To
tal P
ressu
re (
Pa)
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
34°36°
38°40°
42°
42°40°
38°36°
34°
26°
32°
30°
28°
24°22°20°
18°
18° 22° 24°26°
20° 28° 30° 32° 34° 36° 38° 40°42°
0 2 4 6 8 10 12 14
76
77
82
83
78
78
78
84
83
83
84
89
88
86
87
83
83
84
85
TDA 400-V / 12AA/ 5-5/ _ _ / _1750rpm - 60Hz
16
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (KW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6
To
tal P
ressu
re (
Pa)
0.0
1.0
2.0
3.0
4.0
5.0
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 5 10 15 20
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18° 20°22°
24°26°
28°30°
32°34°
36°38°
40°42°
42°40°
38°36°
34°
26°
32°
30°
28°
24°22°
20°18°
18° 22° 24° 26°20° 28° 30° 32° 34° 36° 38° 40° 42°
94
94
99
104
95
95
96
102
102
101
102
108
106
104
105
100
100
100
102
TDA 400-V / 12AA/ 5-5/ _ _ / _3450rpm - 60Hz
17
Series TDA-V
Features For commercial and industrial applications where large
volumes of air are required at moderate to high pressure,
special designed integral straightening vanes, reduced
turbulence, provide high performance and low sound level.
Construction Double flanged casing is produced in mild steel or
galvanised Steel, the impeller having manually adjustable
pitch aerofoil blades is made of PPG, PAG or pressure-
casted Aluminium.
FinishAvailable in standard finishes of galvanisation or painting.
Operating Temperature
-20°C to + 55°C Motors Totally enclosed Class ‘F’ motor, to a min. IP54 protection
are fitted as standard. Standard motor up to 2.2kW are
usually supplied on DOL starting, motor 3.0kW and above
are star/delta starting.
Airflow DirectionAir flowing from impeller to motor is fitted as standard.
DIRECT DRIVEN
MODEL: TDA 450-V / 12AA / 5-5 /__/_
Airflow direction – B
Blade angle - 16°, 18°, 20°, 22°, 24°, 26°, 28°, 30°,
32°, 34°, 36°, 38°
- __/__
Motor no. of pole – 2, 4 or 6
Motor Power kW
12° x Ø10400
Ø4
50
Ø4
90
Ø5
30
* All Dimension in mm
Kruger* certies that the TDA 450 -V shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certied Ratings Program.*Kruger Ventilation Industries Asia Co., Ltd
*Kruger Ventilation (Taiwan) Co., Ltd *Kruger Ventilation Industries (Vietnam) Co., Ltd*Kruger Ventilation Industries (India) Pvt. Ltd*Kruger Ventilation Industries (North India) Pvt. Ltd*Kruger Ventilation Industries (Thailand) Co., Ltd
*P.T. Kruger Ventilation Indonesia*Shanghai Kruger Ventilation Co., Ltd *Wuhan Kruger Ventilation Co., Ltd
*Kruvent Industries (M) Sdn. Bhd
*Guangzhou Kruger Ventilation Co., Ltd
18
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- dBA levels are not licensed by AMCA International. The AMCA Certified Ratings Seal applies to air performance only.
0
10
20
30
40
50
60
70
80
90
100
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
To
tal
Pre
ssu
re (
Pa)
0.00
0.03
0.06
0.09
0.12
0.15
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4
To
tal E
ffic
ien
cy (
%))
Q [m3/s]
Q [m3/s]
0 1 2 3 4 5 6 7 8
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
34°36°
38°
16°
16°
38°36°
34°
26°
32°30°
28°
24°22°
20°18°
18°22°
24°26°
20°
28° 30° 32° 34° 36° 38°
16°
53
56
58
59
56
57
61
60
60
61
62
62
62
64
63
TDA 450-V / 12AA/ 5-5/ _ _ / _950rpm - 50Hz
19
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction. - The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA International.
0
50
100
150
200
250
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2
To
tal
Pre
ssu
re (
Pa)
0.0
0.1
0.2
0.3
0.4
0.5
0.6
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2
To
tal E
ffic
ien
cy (
%))
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
34°36°
38°
16°
16°
38°36°
34°
26°
32°30°
28°
24°22°
20°18°
18°22°
24° 26°
20°
28°30° 32° 34° 36°
38°
16°
64
67
69
70
67
68
72
71
71
72
73
73
73
75
74
TDA 450-V / 12AA/ 5-5/ _ _ / _1450rpm - 50Hz
20
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA International.
0
100
200
300
400
500
600
700
800
900
0.0 0.6 1.2 1.8 2.4 3.0 3.6 4.2
To
tal
Pre
ssu
re (
Pa)
0
1
2
3
4
5
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.6 1.2 1.8 2.4 3.0 3.6 4.2
To
tal E
ffic
ien
cy (
%))
Q [m3/s]
Q [m3/s]
0 5 10 15 20 25
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°
32°34°
36°38°
16°
16°
38°36°
34°
26°
32°30°
28°
24°22°
20°18°
18°22°
24°26°
20°
28° 30° 32° 34° 36° 38°
16°
81
84
86
84
84
85
90
88
88
89
90
90
90
92
91
TDA 450-V / 12AA/ 5-5/ _ _ / _2850rpm - 50Hz
21
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA International.
0
20
40
60
80
100
120
140
160
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8
To
tal
Pre
ssu
re (
Pa)
0.00
0.05
0.10
0.15
0.20
0.25
0.30
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8
To
tal E
ffic
ien
cy (
%))
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
34°36°
38°
16°
16°
38°
36°34°
26°
32°30°
28°
24°22°
20°18°
18°22°
24°26°
20°
28° 30° 32° 34°36°
38°
16°
58
61
63
64
61
62
66
65
65
66
67
67
69
68
TDA 450-V / 12AA/ 5-5/ _ _ / _1150rpm - 60Hz
22
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).. - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA International.
0
50
100
150
200
250
300
350
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6
To
tal
Pre
ssu
re (
Pa)
0.0
0.2
0.4
0.6
0.8
1.0
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6
To
tal E
ffic
ien
cy (
%))
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12 14 16
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°
28°30°
32°34°
36°
38°
16°
16°
38°36°
34°
26°
32°30°
28°
24°22°
20°18°
18°22°
24°26°
20°
28° 30° 32° 34° 36° 38°
16°
69
72
74
75
72
73
77
76
76
77
78
78
78
80
79
TDA 450-V / 12AA/ 5-5/ _ _ / _1750rpm - 60Hz
23
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA International.
0
100
200
300
400
500
600
700
800
900
1000
1100
1200
1300
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
To
tal P
ressu
re (
Pa)
0
1
2
3
4
5
6
7
8
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 5 10 15 20 25 30
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°
28°
30°
32°34°
36°38°
16°
16°
38°36°
34°
26°
32°30°
28°
24°22°
20°18°
18°22° 24°
26°
20°
28° 30° 32° 34° 36°38°
16°
85
88
90
91
88
89
93
92
92
93
94
94
94
96
95
TDA 450-V / 12AA/ 5-5/ _ _ / _3450rpm - 60Hz
24
Series TDA-V
Features For commercial and industrial applications where large
volumes of air are required at moderate to high pressure,
special designed integral straightening vanes, reduced
turbulence, provide high performance and low sound level.
Construction Double flanged casing is produced in mild steel or
galvanised Steel, the impeller having manually adjustable
pitch aerofoil blades is made of PPG, PAG or pressure-
casted Aluminium.
FinishAvailable in standard finishes of galvanisation or painting.
Operating Temperature
-20°C to + 55°C Motors Totally enclosed Class ‘F’ motor, to a min. IP54 protection
are fitted as standard. Standard motor up to 2.2kW are
usually supplied on DOL starting, motor 3.0kW and above
are star/delta starting.
Airflow DirectionAir flowing from impeller to motor is fitted as standard.
DIRECT DRIVEN
MODEL: TDA 500-V / 12AA / 9-9 /__/_
Airflow direction – B
Blade angle - 14°, 16°, 18°, 20°, 22°, 24°, 26°, 28°,
30°, 32°, 34°
- __/__
Motor no. of pole – 2, 4 or 6
Motor Power kW
12° x Ø10500
Ø5
00
Ø5
40
Ø5
80
* All Dimension in mm
Kruger* certies that the TDA 500 -V shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certied Ratings Program.*Kruger Ventilation Industries Asia Co., Ltd
*Kruger Ventilation (Taiwan) Co., Ltd *Kruger Ventilation Industries (Vietnam) Co., Ltd*Kruger Ventilation Industries (India) Pvt. Ltd*Kruger Ventilation Industries (North India) Pvt. Ltd*Kruger Ventilation Industries (Thailand) Co., Ltd
*P.T. Kruger Ventilation Indonesia*Shanghai Kruger Ventilation Co., Ltd *Wuhan Kruger Ventilation Co., Ltd
*Kruvent Industries (M) Sdn. Bhd
*Guangzhou Kruger Ventilation Co., Ltd
25
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
20
40
60
80
100
120
140
160
180
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8
To
tal P
ressu
re (
Pa)
0.0
0.1
0.2
0.3
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8
To
tal E
ffic
ien
cy (
%))
Q [m3/s]
Q [m3/s]
0 1 2 3 4 5 6 7 8 9
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18° 20° 22° 24°26°
28°30°
32°
14°
26°
32°30°
28°
24°22°20°18°
18°22° 24° 26°
20°
28°30° 32°
16°
34°
16°
14°
34°
16°
14°
34°
70
67
65
67
67
66
66
67
67
68
68
68
68
68
69
68
68
68
TDA 500-V / 12AA/ 9-9/ _ _ / _950rpm - 50Hz
26
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction. - The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
300
350
400
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8
To
tal P
ressu
re (
Pa)
0.0
0.2
0.4
0.6
0.8
1.0
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2 2.4 2.6 2.8
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12 14
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18° 20° 22° 24°26°
28°30°
32°
14°
26°
32°
30°
28°
24°22°20°18°
18°22° 24°
26°
20°
28° 30° 32°
16°
34°
16°
14°
34°
16°
14°
34°
81
78
77
79
77
77
79
79
79
79
79
80
79
80
81
80
80
80
TDA 500-V / 12AA/ 9-9/ _ _ / _1450rpm - 50Hz
27
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
300
600
900
1200
1500
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
To
tal P
ressu
re (
Pa)
0.0
0.1
0.2
0.3
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5
To
tal E
ffic
ien
cy (
%))
Q [m3/s]
Q [m3/s]
0 5 10 15 20 25
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18° 20° 22°24°
26°
28°30°
32°
14°
26°
32°30°
28°
24°22°20°18°
18°22° 24°
26°
20°
28° 30° 32°
16°
34°
16°
14°
34°
16°
14°
34°
95
94
97
98
94
95
97
95
96
96
97
96
97
97
98
97
97
97
TDA 500-V / 12AA/ 9-9/ _ _ / _2850rpm - 50Hz
28
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2
To
tal P
ressu
re (
Pa)
0.0
0.1
0.2
0.3
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 1.6 1.8 2.0 2.2
To
tal E
ffic
ien
cy (
%))
Q [m3/s]
Q [m3/s]
0 1 2 3 4 5 6 7 8 9 10 11
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18° 20° 22°24°
26°
28°30°
32°
14°
26°
32°30°
28°
24°22°20°18°
18°22° 24° 26°
20°
28° 30° 32°
16°
34°
16°
14°
34°
16°
14°
34°
72
75
72
71
71
71
72
72
72
73
73
73
74
73
73
73
73
73
TDA 500-V / 12AA/ 9-9/ _ _ / _1150rpm - 60Hz
29
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (KW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
100
200
300
400
500
600
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
To
tal P
ressu
re (
Pa)
0.0
0.4
0.8
1.2
1.6
2.0
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5
To
tal E
ffic
ien
cy (
%))
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12 14 16
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18° 20° 22° 24°26°
28°30°
32°
14°
26°
32°30°
28°
24°22°
20°18°
18°22° 24°
26°
20°
28° 30° 32°
16°
34°
16°
14°
34°
16°
14°
34°
83
82
86
84
82
83
83
83
83
84
84
84
84
84
84
84
85
TDA 500-V / 12AA/ 9-9/ _ _ / _1750rpm - 60Hz
30
Series TDA-V
Features For commercial and industrial applications where large
volumes of air are required at moderate to high pressure,
special designed integral straightening vanes, reduced
turbulence, provide high performance and low sound level.
Construction Double flanged casing is produced in mild steel or
galvanised Steel, the impeller having manually adjustable
pitch aerofoil blades is made of PPG, PAG or pressure-
casted Aluminium.
FinishAvailable in standard finishes of galvanisation or painting.
Operating Temperature
-20°C to + 55°C Motors Totally enclosed Class ‘F’ motor, to a min. IP54 protection
are fitted as standard. Standard motor up to 2.2kW are
usually supplied on DOL starting, motor 3.0kW and above
are star/delta starting.
Airflow DirectionAir flowing from impeller to motor is fitted as standard.
DIRECT DRIVEN
MODEL: TDA 560-V / 12AA / 9-9 /__/_
Airflow direction – B
Blade angle - 12°, 14°, 16°, 18°, 20°, 22°, 24°, 26°,
28°, 30°, 32°
- __/__
Motor no. of pole – 2, 4 or 6
Motor Power kW
12° x Ø10500
Ø5
60
Ø6
60
Ø6
05
* All Dimension in mm
Kruger* certies that the TDA 560 -V shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certied Ratings Program.*Kruger Ventilation Industries Asia Co., Ltd
*Kruger Ventilation (Taiwan) Co., Ltd *Kruger Ventilation Industries (Vietnam) Co., Ltd*Kruger Ventilation Industries (India) Pvt. Ltd*Kruger Ventilation Industries (North India) Pvt. Ltd*Kruger Ventilation Industries (Thailand) Co., Ltd
*P.T. Kruger Ventilation Indonesia*Shanghai Kruger Ventilation Co., Ltd *Wuhan Kruger Ventilation Co., Ltd
*Kruvent Industries (M) Sdn. Bhd
*Guangzhou Kruger Ventilation Co., Ltd
31
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
20
40
60
80
100
120
140
160
180
0.0 0.5 1.0 1.5 2.0 2.5
To
tal P
ressu
re (
Pa)
0.0
0.1
0.2
0.3
0.4
0.5
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.5 1.0 1.5 2.0 2.5
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 1 2 3 4 5 6 7 8 9 10
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
14°
26°
32°30°
28°
24°22°
20°18°
18°
22° 24° 26°
20°
28° 30° 32°
16°
12°16°
14°12°
16°
14°12°
72
70
73
70
70
70
69
70
69
69
71
71
71
71
TDA 560-V / 12AA/ 9-9/ _ _ / _950rpm - 50Hz
32
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
300
350
400
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
To
tal P
ressu
re (
Pa)
0.0
0.3
0.6
0.9
1.2
1.5
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12 14 16
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
14°
26°
32°30°
28°
24°
22°20°
18°
18°22°
24° 26°
20°
28° 30° 32°
16°
12°16°
14°12°
16°
14°12°
83
81
81
84
80
80
81
81
80
80
82
82
82
83
TDA 560-V / 12AA/ 9-9/ _ _ / _1450rpm - 50Hz
33
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
200
400
600
800
1000
1200
1400
1600
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
To
tal P
ressu
re (
Pa)
0
2
4
6
8
10
12
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
To
tal E
ffic
ien
cy (
%))
Q [m3/s]
Q [m3/s]
0 5 10 15 20 25 30
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
14°
26°
32°30°
28°
24°22°
20°18°
18°
22° 24°26°
20°
28° 30° 32°
16°
12°16°
14°12°
16°
14°12°
99
99
100
99
97
96
97
97
96
98
98
98
99
100
TDA 560-V / 12AA/ 9-9/ _ _ / _2850rpm - 50Hz
34
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
0.0 0.5 1.0 1.5 2.0 2.5 3.0
To
tal P
ressu
re (
Pa)
0.0
0.1
0.2
0.3
0.4
0.5
0.6
0.7
0.8
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.5 1.0 1.5 2.0 2.5 3.0
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 1 2 3 4 5 6 7 8 9 10 11 12
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
14°
26°
32°30°
28°
24°22°
20°18°
18°
22°24° 26°
20°
28° 30° 32°
16°
12°16°
14°12°
16°
14°12°
77
75
75
78
74
74
75
75
74
74
76
76
76
76
TDA 560-V / 12AA/ 9-9/ _ _ / _1150rpm - 60Hz
35
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
100
200
300
400
500
600
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
To
tal
Pre
ssu
re (
Pa)
0.0
0.3
0.6
0.9
1.2
1.5
1.8
2.1
2.4
2.7
3.0
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
To
tal
Eff
icie
ncy (
%))
Q [m3/s]
Q [m3/s]
0 5 10 15 20
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
14°
26°
32°30°
28°
24°22°20°
18°
18°
22° 24°26°
20°
28° 30° 32°
16°
12°16°
14°12°
16°
14°12°
86
88
88
84
85
86
85
85
84
85
86
86
87
87
TDA 560-V / 12AA/ 9-9/ _ _ / _1750rpm - 60Hz
36
Series TDA-V
Features For commercial and industrial applications where large
volumes of air are required at moderate to high pressure,
special designed integral straightening vanes, reduced
turbulence, provide high performance and low sound level.
Construction Double flanged casing is produced in mild steel or
galvanised Steel, the impeller having manually adjustable
pitch aerofoil blades is made of PPG, PAG or pressure-
casted Aluminium.
FinishAvailable in standard finishes of galvanisation or painting.
Operating Temperature
-20°C to + 55°C Motors Totally enclosed Class ‘F’ motor, to a min. IP54 protection
are fitted as standard. Standard motor up to 2.2kW are
usually supplied on DOL starting, motor 3.0kW and above
are star/delta starting.
Airflow DirectionAir flowing from impeller to motor is fitted as standard.
DIRECT DRIVEN
MODEL: TDA 630-V / 12AA / 12-12 /__/_
Airflow direction – B
Blade angle - 8°, 10°, 12°, 14°, 16°, 18°, 20°, 22°,
24°, 26°, 28°, 30°, 32°, 34°, 36°, 38°,
40°
- __/__
Motor no. of pole – 4 or 6
Motor Power kW
12° x Ø10500
Ø6
30
Ø6
75
Ø7
30
* All Dimension in mm
Kruger* certies that the TDA 630 -V shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certied Ratings Program.*Kruger Ventilation Industries Asia Co., Ltd
*Kruger Ventilation (Taiwan) Co., Ltd *Kruger Ventilation Industries (Vietnam) Co., Ltd*Kruger Ventilation Industries (India) Pvt. Ltd*Kruger Ventilation Industries (North India) Pvt. Ltd*Kruger Ventilation Industries (Thailand) Co., Ltd
*P.T. Kruger Ventilation Indonesia*Shanghai Kruger Ventilation Co., Ltd *Wuhan Kruger Ventilation Co., Ltd
*Kruvent Industries (M) Sdn. Bhd
*Guangzhou Kruger Ventilation Co., Ltd
37
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
To
tal P
ressu
re (
Pa)
0.0
0.3
0.6
0.9
1.2
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 3 6 9 12
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
34°36°
38°40°
14°
40°38°
36°34°
26°
32°30°
28°
24°22°
20°18°
18°22° 24°
26°
20°
28° 30° 32° 34° 36° 38° 40°
16°
12°10°8°
16°
14°12°10°8°
16°
14°12°8° 10°
79
79
77
78
78
80
79
78
79
81
80
81
81
82
82
82
83
84
TDA 630-V / 12AA/ 12-12/ _ _ / _950rpm - 50Hz
38
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.l
0
100
200
300
400
500
600
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5
To
tal P
ressu
re (
Pa)
0
1
2
3
4
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 3 6 9 12 15 18
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
34°36°
38°40°
14°
40°38°
36°34°
26°
32°30°
28°
24°22°
20°18°
18°22° 24°
26°
20°
28°30° 32° 34° 36° 38° 40°
16°
12°10°8°
16°
14°12°10°8°
16°
14°12°
8°10°
90
88
87 91
89
89
91
89
90
93
92
92
92
92
93
93
95
94
TDA 630-V / 12AA/ 12-12/ _ _ / _1450rpm - 50Hz
39
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
40
80
120
160
200
240
280
320
360
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
To
tal P
ressu
re (
Pa)
0.0
0.5
1.0
1.5
2.0
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 3 6 9 12 15
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
34°36°
38°40°
14°
40°38°
36°34°
26°
32°30°
28°
24°22°
20°18°
18°
22° 24° 26°
20°
28°30° 32° 34° 36° 38° 40°
16°
12°10°8°
16°
14°12°10°8°
16°
14°12°8° 10°
84
8582
83
83
85
83
84
85
86
86
86
87
87
87
88
89
TDA 630-V / 12AA/ 12-12/ _ _ / _1150rpm - 60Hz
40
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
100
200
300
400
500
600
700
800
900
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
To
tal P
ressu
re (
Pa)
0
1
2
3
4
5
6
7
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0.0 1.0 2.0 3.0 4.0 5.0 6.0 7.0 8.0
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 3 6 9 12 15 18 21 24
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
34°36°
38°40°
14°
40°38°
36°34°
26°
32°30°
28°
24°22°
20°18°
18°22° 24°
26°
20°
28° 30° 32° 34° 36° 38° 40°
16°
12°10°8°
16°
14°12°10°8°
16°
14°12°
8°10°
96
93
94
93
93
96
95
94
96
97
96
97
97
97
97
98
99
TDA 630-V / 12AA/ 12-12/ _ _ / _1750rpm - 60Hz
41
Series TDA-V
Features For commercial and industrial applications where large
volumes of air are required at moderate to high pressure,
special designed integral straightening vanes, reduced
turbulence, provide high performance and low sound level.
Construction Double flanged casing is produced in mild steel or
galvanised Steel, the impeller having manually adjustable
pitch aerofoil blades is made of PPG, PAG or pressure-
casted Aluminium.
FinishAvailable in standard finishes of galvanisation or painting.
Operating Temperature
-20°C to + 55°C Motors Totally enclosed Class ‘F’ motor, to a min. IP54 protection
are fitted as standard. Standard motor up to 2.2kW are
usually supplied on DOL starting, motor 3.0kW and above
are star/delta starting.
Airflow DirectionAir flowing from impeller to motor is fitted as standard.
DIRECT DRIVEN
MODEL: TDA 710-V / 14 AA / 12-12 /__/_
Airflow direction – B
Blade angle - 16°, 18°, 20°, 22°, 24°, 26°, 28°, 30°,
32°, 34°, 36°, 38°, 40°
- __/__
Motor no. of pole – 4 or 6
Motor Power kW
500
Ø7
10
Ø7
55
Ø8
10
18° x Ø12
* All Dimension in mm
Kruger* certies that the TDA 710 -V shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certied Ratings Program.*Kruger Ventilation Industries Asia Co., Ltd
*Kruger Ventilation (Taiwan) Co., Ltd *Kruger Ventilation Industries (Vietnam) Co., Ltd*Kruger Ventilation Industries (India) Pvt. Ltd*Kruger Ventilation Industries (North India) Pvt. Ltd*Kruger Ventilation Industries (Thailand) Co., Ltd
*P.T. Kruger Ventilation Indonesia*Shanghai Kruger Ventilation Co., Ltd *Wuhan Kruger Ventilation Co., Ltd
*Kruvent Industries (M) Sdn. Bhd
*Guangzhou Kruger Ventilation Co., Ltd
42
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
300
350
0 1 2 3 4 5 6
To
tal P
ressu
re (
Pa)
0.0
0.5
1.0
1.5
2.0
2.5
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0 1 2 3 4 5 6
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12 14
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
26°
32°30°
28°
24°22°20°
18°
18°22° 24° 26°
20°28°
30° 32°
16°
16°
36°34°
16°
36°34°
34°36°
38°40°
38°40°
38° 40°
80
79
80
80
79
78
7880
78
79
79
82
81
83
84
84
82
84
85
85
TDA 710-V / 14AA/ 12-12/ _ _ / _950rpm - 50Hz
43
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
100
200
300
400
500
600
700
800
0 1 2 3 4 5 6 7 8 9
To
tal P
ressu
re (
Pa)
0
2
4
6
8
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0 1 2 3 4 5 6 7 8 9
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 5 10 15 20
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
26°
32°30°
28°
24°22°
20°18°
18°22° 24° 26°
20°28° 30°32°
16°
16°
36°34°
16°
36°34°
34°36°
38°40°
38°40°
38° 40°
90
90
91
90
89
8991
89
93
90
90
92
94
95
95
93
95
96
96
TDA 710-V / 14AA/ 12-12/ _ _ / _1450rpm - 50Hz
44
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
300
350
400
450
500
0 1 2 3 4 5 6 7 8
To
tal P
ressu
re (
Pa)
0.0
1.0
2.0
3.0
4.0
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0 1 2 3 4 5 6 7 8
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 5 10 15 20
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
26°
32°30°
28°
24°22°
20°18°
18°22° 24° 26°
20°28° 30°32°
16°
16°
36°34°
16°
36°34°
34°36°
38°40°
38°
40°
38° 40°
84
84
85
85
84
83
8385
83
87
84
84
86
88
89
87
89
90
TDA 710-V / 14AA/ 12-12/ _ _ / _1150rpm - 60Hz
45
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
200
400
600
800
1000
1200
0 1 2 3 4 5 6 7 8 9 10 11
To
tal P
ressu
re (
Pa)
0
2
4
6
8
10
12
14
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0 1 2 3 4 5 6 7 8 9 10 11
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 5 10 15 20 25
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
26°
32°
30°28°
24°22°
20°18°
18°22° 24° 26°
20°28°
30° 32°
16°
16°
36°34°
16°
36°34°
34°36°
38°40°
38°40°
38° 40°
95
94
96
96
94
93
93
94
98
94
94
97
99
99
99
98
100
100
100
TDA 710-V / 14AA/ 12-12/ _ _ / _1750rpm - 60Hz
46
Series TDA-V
Features For commercial and industrial applications where large
volumes of air are required at moderate to high pressure,
special designed integral straightening vanes, reduced
turbulence, provide high performance and low sound level.
Construction Double flanged casing is produced in mild steel or
galvanised Steel, the impeller having manually adjustable
pitch aerofoil blades is made of PPG, PAG or pressure-
casted Aluminium.
FinishAvailable in standard finishes of galvanisation or painting.
Operating Temperature
-20°C to + 55°C Motors Totally enclosed Class ‘F’ motor, to a min. IP54 protection
are fitted as standard. Standard motor up to 2.2kW are
usually supplied on DOL starting, motor 3.0kW and above
are star/delta starting.
Airflow DirectionAir flowing from impeller to motor is fitted as standard.
DIRECT DRIVEN
MODEL: TDA 800-V / 14AA / 12-12 /__/_
Airflow direction – B
Blade angle - 12°, 14°, 16°, 18°, 20°, 22°, 24°, 26°,
28°, 30°, 32°
- __/__
Motor no. of pole – 4 or 6
Motor Power kW
18° x Ø12560
Ø8
00
Ø8
45
Ø9
00
* All Dimension in mm
Kruger* certies that the TDA 800 -V shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certied Ratings Program.*Kruger Ventilation Industries Asia Co., Ltd
*Kruger Ventilation (Taiwan) Co., Ltd *Kruger Ventilation Industries (Vietnam) Co., Ltd*Kruger Ventilation Industries (India) Pvt. Ltd*Kruger Ventilation Industries (North India) Pvt. Ltd*Kruger Ventilation Industries (Thailand) Co., Ltd
*P.T. Kruger Ventilation Indonesia*Shanghai Kruger Ventilation Co., Ltd *Wuhan Kruger Ventilation Co., Ltd
*Kruvent Industries (M) Sdn. Bhd
*Guangzhou Kruger Ventilation Co., Ltd
47
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
300
350
0 1 2 3 4 5 6 7 8
To
tal P
ressu
re (
Pa)
0
1
2
3
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0 2 4 6 8
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12 14
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
14°
26°
32°
30°
28°
24°22°
20°18°
18°22° 24° 26°
20°
28° 30° 32°
16°
12°
16°
14°12°
16°
14°12°
83
82
86
86
83
82
87
83
82
88
88
83
83
89
89
TDA 800-V / 14AA/ 12-12/ _ _ / _950rpm - 50Hz
48
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
100
200
300
400
500
600
700
800
0 1 2 3 4 5 6 7 8 9 10 11 12
To
tal P
ressu
re (
Pa)
0
2
4
6
8
10
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0 1 2 3 4 5 6 7 8 9 10 11 12
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 5 10 15 20
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°
28°30°
32°
14°
26°
32°
30°
28°
24°22°
20°18°
18°22° 24° 26°
20°
28° 30° 32°
16°
12°
16°
14°12°
16°
14°12°
94
92
97
97
94
93
98
94
93
99
99
94
94
100
100
TDA 800-V / 14AA/ 12-12/ _ _ / _1450rpm - 50Hz
49
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
300
350
400
450
500
0 1 2 3 4 5 6 7 8 9 10
To
tal P
ressu
re (
Pa)
0
1
2
3
4
5
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0 1 2 3 4 5 6 7 8 9 10
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 5 10 15
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
14°
26°
32°
30°
28°
24°
22°20°
18°
18°22° 24° 26°
20°
28° 30° 32°
16°
12°
16°
14°12°
16°
14°12°
88
87
91
91
88
87
92
88
87
93
93
88
88
94
94
TDA 800-V / 14AA/ 12-12/ _ _ / _1150rpm - 60Hz
50
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).) - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
200
400
600
800
1000
1200
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
To
tal P
ressu
re (
Pa)
0
2
4
6
8
10
12
14
16
18
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 5 10 15 20 25
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°
32°
14°
26°
32°
30°
28°
24°22°
20°18°
18°22° 24° 26°
20°
28° 30° 32°
16°
12°
16°
14°12°
16°
14°12°
98
97
102
102
98
98
103
99
97
104
104
98
98
105
105
TDA 800-V / 14AA/ 12-12/ _ _ / _1750rpm - 60Hz
51
Series TDA-V
Features For commercial and industrial applications where large
volumes of air are required at moderate to high pressure,
special designed integral straightening vanes, reduced
turbulence, provide high performance and low sound level.
Construction Double flanged casing is produced in mild steel or
galvanised Steel, the impeller having manually adjustable
pitch aerofoil blades is made of PPG, PAG or pressure-
casted Aluminium.
FinishAvailable in standard finishes of galvanisation or painting.
Operating Temperature
-20°C to + 55°C Motors Totally enclosed Class ‘F’ motor, to a min. IP54 protection
are fitted as standard. Standard motor up to 2.2kW are
usually supplied on DOL starting, motor 3.0kW and above
are star/delta starting.
Airflow DirectionAir flowing from impeller to motor is fitted as standard.
DIRECT DRIVEN
MODEL: TDA 900-V / 14AA / 12-12 /__/_
Airflow direction – B
Blade angle - 10°, 12°, 14°, 16°, 18°, 20°, 22°, 24°,
26°, 28°, 30°, 32°
- __/__
Motor no. of pole – 4 or 6
Motor Power kW
18° x Ø12630
Ø9
00
Ø9
45
Ø1
00
0
* All Dimension in mm
Kruger* certies that the TDA 900 -V shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certied Ratings Program.*Kruger Ventilation Industries Asia Co., Ltd
*Kruger Ventilation (Taiwan) Co., Ltd *Kruger Ventilation Industries (Vietnam) Co., Ltd*Kruger Ventilation Industries (India) Pvt. Ltd*Kruger Ventilation Industries (North India) Pvt. Ltd*Kruger Ventilation Industries (Thailand) Co., Ltd
*P.T. Kruger Ventilation Indonesia*Shanghai Kruger Ventilation Co., Ltd *Wuhan Kruger Ventilation Co., Ltd
*Kruvent Industries (M) Sdn. Bhd
*Guangzhou Kruger Ventilation Co., Ltd
52
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
300
350
400
450
0 1 2 3 4 5 6 7 8 9 10 11 12
To
tal
Pre
ssu
re (
Pa)
0
1
2
3
4
5
6
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0 1 2 3 4 5 6 7 8 9 10 11 12
To
tal
Eff
icie
ncy (
%)
Q [m3/s]
Q [m3/s]
0 5 10 15
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
14°
26°
32°30°
28°
24°22°
20°18°
18°
22° 24°26°20°28° 30° 32°
16°
12°10°
16°
14°12°
10°
16°
14°12°
10°
86
86
87
83
86
85
84
86
87
87
85
89
TDA 900-V / 14AA/ 12-12/ _ _ / _950rpm - 50Hz
53
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
100
200
300
400
500
600
700
800
900
1000
0 3 6 9 12 15 18
To
tal
Pre
ssu
re (
Pa)
0
5
10
15
20
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0 3 6 9 12 15 18
To
tal
Eff
icie
ncy (
%)
Q [m3/s]
Q [m3/s]
0 5 10 15 20 25
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
30°32°
14°
26°
32°30°
28°
24°22°
20°18°
18°
22° 24°26°20°
28° 30° 32°
16°
12°10°
16°
14°12°
10°
16°
14°12°
10°
97
97
98
95
97
96
95
97
97
98
100
TDA 900-V / 14AA/ 12-12/ _ _ / _1450rpm - 50Hz
54
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
100
200
300
400
500
600
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
To
tal P
ressu
re (
Pa)
0
2
4
6
8
10
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 5 10 15 20
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°
20°
22°24°
26°28°
30°32°
14°
26°
32°30°
28°
24°22°
20°18°
18°
22° 24° 26°20° 28° 30° 32°
16°
12°10°
16°
14°12°
10°
16°
14°12°10°
91
91
92
89
91
90
89
91
91
92
94
TDA 900-V / 14AA/ 12-12/ _ _ / _1150rpm - 60Hz
55
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
200
400
600
800
1000
1200
1400
0 2 4 6 8 10 12 14 16 18 20 22
To
tal
Pre
ssu
re (
Pa)
0
5
10
15
20
25
30
35
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0 2 4 6 8 10 12 14 16 18 20 22
To
tal
Eff
icie
ncy (
%)
Q [m3/s]
Q [m3/s]
0 5 10 15 20 25 30
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°
20°22°
24°26°
28°30°
32°
14°
26°
32°30°
28°
24°
22°20°
18°
18°
22°24° 26°20°
28° 30° 32°
16°
12°10°
16°
14°12°
10°
16°
14°12°10°
101
101
102
99
101
103
100
100
102
101
103
105
TDA 900-V / 14AA/ 12-12/ _ _ / _1750rpm - 60Hz
56
Series TDA-V
Features For commercial and industrial applications where large
volumes of air are required at moderate to high pressure,
special designed integral straightening vanes, reduced
turbulence, provide high performance and low sound level.
Construction Double flanged casing is produced in mild steel or
galvanised Steel, the impeller having manually adjustable
pitch aerofoil blades is made of PPG, PAG or pressure-
casted Aluminium.
FinishAvailable in standard finishes of galvanisation or painting.
Operating Temperature
-20°C to + 55°C Motors Totally enclosed Class ‘F’ motor, to a min. IP54 protection
are fitted as standard. Standard motor up to 2.2kW are
usually supplied on DOL starting, motor 3.0kW and above
are star/delta starting.
Airflow DirectionAir flowing from impeller to motor is fitted as standard.
DIRECT DRIVEN
MODEL: TDA 1000-V / 14AA / 12-12 /__/_
Airflow direction – B
Blade angle - 4°, 6°, 8°, 10°, 12°, 14°, 16°, 18°, 20°,
22°, 24°, 26°, 28°
- __/__
Motor no. of pole – 4, 6 or 8
Motor Power kW
630
Ø1
00
0
Ø1
05
0
Ø1
10
0
24° x Ø12
* All Dimension in mm
Kruger* certies that the TDA 1000 -V shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certied Ratings Program.*Kruger Ventilation Industries Asia Co., Ltd
*Kruger Ventilation (Taiwan) Co., Ltd *Kruger Ventilation Industries (Vietnam) Co., Ltd*Kruger Ventilation Industries (India) Pvt. Ltd*Kruger Ventilation Industries (North India) Pvt. Ltd*Kruger Ventilation Industries (Thailand) Co., Ltd
*P.T. Kruger Ventilation Indonesia*Shanghai Kruger Ventilation Co., Ltd *Wuhan Kruger Ventilation Co., Ltd
*Kruvent Industries (M) Sdn. Bhd
*Guangzhou Kruger Ventilation Co., Ltd
57
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
300
0 2 4 6 8 10 12
To
tal P
ressu
re (
Pa)
0
1
2
3
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0 2 4 6 8 10 12
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12 14
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°28°
14°
26°28°
24°22°
20°18°
18° 22° 24° 26°20°
28°
16°
12°10°
16°
14°12°10°
16°
14°12°
10°
8°6°
4°
8°6°4°
8°6°
4°
84
85
85
84
84
87
68
83
87
87
68
82
83
83
70
84
85
85
TDA 1000-V / 14AA/ 12-12/ _ _ / _725rpm - 50Hz
58
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).) - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.l
0
50
100
150
200
250
300
350
400
450
0 2 4 6 8 10 12 14 16
To
tal P
ressu
re (
Pa)
0
2
4
6
8
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0 2 4 6 8 10 12 14 16
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 5 10 15 20
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°
24°
26°
28°
14°
26°
28°
24°22°
20°
18°
18° 22° 24° 26°20°
28°16°
12°10°
16°
14°12°10°
16°
14°12°
10°
8°6°
4°
8°6°4°
8°6°
4°
91
91
91
91
90
93
75
89
93
93
75
89
89
89
77
91
91
91
TDA 1000-V / 14AA/ 12-12/ _ _ / _950rpm - 50Hz
59
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).) - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.l
0
200
400
600
800
1000
1200
0 4 8 12 16 20 24
To
tal P
ressu
re (
Pa)
0
5
10
15
20
25
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0 4 8 12 16 20 24
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 5 10 15 20 25 30
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°
28°
14°
26°28°
24°
22°
20°18°
18° 22° 24° 26°20°
28°
16°
12°10°
16°
14°12°10°
16°
14°12°
10°
8°6°
4°
8°6°
4°
8°6°
4°
101
101
101
103
101
100
103
86
100
103
86
101
101
101
88
103
103
103
TDA 1000-V / 14AA/ 12-12/ _ _ / _1450rpm - 50Hz
60
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).) - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.l
0
50
100
150
200
250
300
350
400
0 3 6 9 12 15
To
tal P
ressu
re (
Pa)
0
1
2
3
4
5
6
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0 3 6 9 12 15
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12 14 16 18
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°
28°
14°
26°28°
24°22°
20°18°
18° 22° 24° 26°20°
28°16°
12°10°
16°
14°12°
10°
16°
14°12°
10°
8°6°
4°
8°6°4°
8°6°
4°
89
89
89
89
88
91
73
87
91
91
73
87
87
87
75
89
89
89
TDA 1000-V / 14AA/ 12-12/ _ _ / _875rpm - 60Hz
61
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).) - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.l
0
100
200
300
400
500
600
700
0 2 4 6 8 10 12 14 16 18 20
To
tal P
ressu
re (
Pa)
0
2
4
6
8
10
12
14
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0 2 4 6 8 10 12 14 16 18 20
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 5 10 15 20 25
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°
24°26°
28°
14°
26°
28°
24°22°
20°18°
18° 22° 24° 26°20°
28°
16°
12°10°
16°
14°12°
10°
16°
14°12°
10°
8°6°
4°
8°6°4°
8°6°
4°
95
96
95
95
94
98
80
94
98
98
80
94
94
94
82
96
96
96
TDA 1000-V / 14AA/ 12-12/ _ _ / _1150rpm - 60Hz
62
- Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.l
0
200
400
600
800
1000
1200
1400
1600
0 5 10 15 20 25 30
To
tal P
ressu
re (
Pa)
0
5
10
15
20
25
30
35
40
45
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0 5 10 15 20 25 30
To
tal E
ffic
ien
cy (
%)
Q [m3/s]
Q [m3/s]
0 5 10 15 20 25 30 35
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°
28°
14°
26°28°
24°22°
20°
18°
18° 22° 24°26°
20°28°
16°
12°10°
16°
14°12°
10°
16°
14°12°
10°
8°6°
4°
8°6°4°
8°6°
4°
105
105
105
105
104
107
91
104
107
107
91
104
104
104
93
106
106
106
TDA 1000-V / 14AA/ 12-12/ _ _ / _1750rpm - 60Hz
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories).
.
63
Series TDA-V
Features For commercial and industrial applications where large
volumes of air are required at moderate to high pressure,
special designed integral straightening vanes, reduced
turbulence, provide high performance and low sound level.
Construction Double flanged casing is produced in mild steel or
galvanised Steel, the impeller having manually adjustable
pitch aerofoil blades is made of PPG, PAG or pressure-
casted Aluminium.
FinishAvailable in standard finishes of galvanisation or painting.
Operating Temperature
-20°C to + 55°C Motors Totally enclosed Class ‘F’ motor, to a min. IP54 protection
are fitted as standard. Standard motor up to 2.2kW are
usually supplied on DOL starting, motor 3.0kW and above
are star/delta starting.
Airflow DirectionAir flowing from impeller to motor is fitted as standard.
DIRECT DRIVEN
MODEL: TDA 1120-V / 14AA / 12-12 /__/_
Airflow direction – B
Blade angle - 0°, 2°, 4°, 6°, 8°, 10°, 12°, 14°, 16°,
18°, 20°, 22°, 24°, 26°
- __/__
Motor no. of pole – 4, 6 or 8
Motor Power kW
24° x Ø12900
Ø1
12
0
Ø1
18
5
Ø1
25
0
* All Dimension in mm
Kruger* certies that the TDA 1120 -V shown herein is licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA publication 211 and comply with the requirements of the AMCA Certied Ratings Program.*Kruger Ventilation Industries Asia Co., Ltd
*Kruger Ventilation (Taiwan) Co., Ltd *Kruger Ventilation Industries (Vietnam) Co., Ltd*Kruger Ventilation Industries (India) Pvt. Ltd*Kruger Ventilation Industries (North India) Pvt. Ltd*Kruger Ventilation Industries (Thailand) Co., Ltd
*P.T. Kruger Ventilation Indonesia*Shanghai Kruger Ventilation Co., Ltd *Wuhan Kruger Ventilation Co., Ltd
*Kruvent Industries (M) Sdn. Bhd
*Guangzhou Kruger Ventilation Co., Ltd
64
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
300
0 2 4 6 8 10 12 14 16
To
tal P
ressu
re (
Pa)
0
1
2
3
4
5
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0 2 4 6 8 10 12 14 16
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12 14 16
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°
20°22°
24°26°
14°
26°
24°
22°20°
18°
18°22° 24° 26°20°
16°
12°10°
16°
14°12°
10°
16°
14°12°10°
8°6°
4°
8°6°4°
8°6°
4°
2°0°
2°0°
2°0°
91
89
92
91
89
94
85
89
91
77
89
92
92
78
90
93
93
TDA 1120-V / 14AA/ 12-12/ _ _ / _725rpm - 50Hz
65
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
100
200
300
400
500
0 2 4 6 8 10 12 14 16 18 20
To
tal P
ressu
re (
Pa)
0
2
4
6
8
10
12
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0 2 4 6 8 10 12 14 16 18 20
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 2 4 6 8 10 12 14 16 18 20
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°
14°
26°24°
22°20°
18°
18°22° 24° 26°20°
16°
12°10°
16°
14°
12°10°
16°
14°12°10°
8°6°
4°
8°6°4°
8°6°
4°
2°0°
2°0°
2°0°
98
96
98
98
96
100
91
96
98
84
96
99
99
85
97
100
100
TDA 1120-V / 14AA/ 12-12/ _ _ / _950rpm - 50Hz
66
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
200
400
600
800
1000
1200
0 4 8 12 16 20 24 28 32
To
tal P
ressu
re (
Pa)
0
10
20
30
40
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0 4 8 12 16 20 24 28 32
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 5 10 15 20 25 30
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°20°
22°24°
26°
14°
26°
24°
22°20°
18°
18° 22° 24° 26°20°16°
12°10°
16°
14°12°
10°
16°
14°12°10°
8°6°
4°
8°6°4°
8°6°
4°
2°0°
2°0°
2°0°
108
106
110
108
106
111
102
106
108
109
95
107
109
96
108
110
110
TDA 1120-V / 14AA/ 12-12/ _ _ / _1450rpm - 50Hz
67
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
50
100
150
200
250
300
350
400
0 2 4 6 8 10 12 14 16 18 20
To
tal P
ressu
re (
Pa)
0
2
4
6
8
Ab
so
rbe
d P
ow
er
(kW
)
0
10
20
30
40
50
60
70
80
0 2 4 6 8 10 12 14 16 18 20
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 5 10 15 20
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°
20°
22°24°
26°
14°
26°
24°
22°
20°18°
18°22° 24° 26°20°
16°
12°10°
16°
14°12°
10°
16°
14°12°10°
8°6°
4°
8°6°4°
8°6°
4°
2°0°
2°0°
2°0°
96
94
96
96
94
98
89
94
96
82
94
97
97
83
95
98
98
TDA 1120-V / 14AA/ 12-12/ _ _ / _875rpm - 60Hz
68
- Performance certified is for installation type D - ducted inlet, ducted outlet. Performance ratings do not include the effects of appurtenances (accessories). - Power ratings (kW) does not include transmission losses.
- The A-weighted sound ratings shown have been calculated per AMCA Standard 301. Values shown are for inlet Lwi(A) sound power level for installation type D - ducted inlet, ducted outlet, rating include the effect of duct end correction.
- The AMCA Certified Ratings Seal applies to air performance only. dBA levels are not licensed by AMCA international.
0
100
200
300
400
500
600
700
0 2 4 6 8 10 12 14 16 18 20 22 24 26
To
tal P
ressu
re (
Pa)
0
4
8
12
16
20
Ab
so
rbed
Po
wer
(kW
)
0
10
20
30
40
50
60
70
80
0 2 4 6 8 10 12 14 16 18 20 22 24 26
To
tal E
ffic
ien
cy
(%
)
Q [m3/s]
Q [m3/s]
0 5 10 15 20 25
V [m/s]
Lw(A) [dB(A)]
γ=1.22kg/m3
18°
20°
22°24°
26°
14°
26°24°
22°
20°18°
18°22° 24° 26°20°
16°
12°10°
16°
14°12°
10°
16°
14°12°10°
8°6°
4°
8°6°4°
8°6°
4°
2°0°
2°0°
2°0°
102
100
103
102
100
104
96
100
102
89
103
101
103
90
102
104
104
TDA 1120-V / 14AA/ 12-12/ _ _ / _1150rpm - 60Hz
69
• THAILAND (Regional HQ) • AUSTRALIA
KRUGER VENTILATION INDUSTRIES ASIA CO. LTD. S&P-KRUGER AUSTRALIA PTY LTD 30/159 Moo 1, Sinsakorn Industrial Estate, 2 Cunningham St, Moorebank N.S.W. 2170
Chetsadawithi Road, Khok Kham Mueng, Samuthsakorn 74000, Thailand Tel. + 61 2-98227747
Tel. + 662 1054298 - Fax + 662 0248256-9 Fax. + 61 2-98227757
Website: www.krugerfan.com Email: [email protected]
• (BEIJING) • CHINA (GUANGZHOU)
BEIJING KRUGER VENTILATION CO. LTD GUANGZHOU KRUGER VENTILATION CO. LTD Level 7, A Block, Rising International Building, 29 JingHai San Road, BDA, No. 9 Huahui Road, Huashan, Huadu,
Beij ing, P.R.China 100176 Guangzhou, P.R. China 510880
Tel. + 86 10-67881366 - Fax + 86 10-67880566 Tel. + 86 20-66356635 - Fax + 86 20-86786001/86786500
Email: krugertj@krugertj .com Email: [email protected]
• CHINA (SHANGHAI) • CHINA (TIANJIN)
SHANGHAI KRUGER VENTILATION CO. LTD TIANJIN KRUGER VENTILATION CO. LTD No. 500 Yuanguo Road, Ant ing, Jiading, No.168 Anyuan Road, Jingj in Science and Technology Park
Shanghai 201814 P.R. China Wuqing District , Tianj in, China
Tel. + 86 21-69573266 - Fax + 86 21-69573296 Tel. + 86 22-22143480/3481 - Fax + 86 22-22143482
Email: [email protected] Email: krugertj@krugertj .com
• CHINA (WUHAN) • DUBAI
WUHAN KRUGER VENTILATION CO. LTD KRUGER VENTILATION INDUSTRIES, GULF BRANCH No. 805, Huian Ave, Dongxihu District, Wuhan, Hubei, P.R. China 430000 Jebel Ali Free Zone Area (JAFZA) P.O. Box No. 262949, Dubai, UAE Tel. + 86 27- 83248840/83060522/83097505 Tel. + 971 4 8819188/8832017
Fax + 86 27- 83261886 Fax. + 971 4 8832018
Email: [email protected] Email: [email protected]
• HONG KONG • INDIA
KRUGER VENTILATION (HONG KONG) LIMITED KRUGER VENTILATION INDUSTRIES (INDIA) PVT LTD Flat C, 9/F, Yeung Yiu Chung (No.8) Industrial Building, Kruger Centre, Mumbai-Nasik Highway, 20 Wang Hoi Road, Kowloon Bay, Kowloon, Hong Kong Kalamgaon, Shahapur, Thane 421601, Maharashtra, India
Tel. + 852 22469182 - Fax + 852 22469187 Tel. + 91 9960558899/9975577211 - Fax + 91 2527 240075
Email: [email protected] Email: [email protected]
• INDIA (NORTH) • INDONESIA
KRUGER VENTILATION INDUSTRIES (NORTH INDIA) PVT LTD P.T. KRUGER VENTILATION INDONESIA Plot No. - 191, Sector - 59, Ballabgarh, Faridabad - 121 004, Haryana, India JL. Teuku Umar No.20, Tel. + 91-9958991660/9717449696 Karawaci - Tangerang 15115, Indonesia Fax. + 91-1294135820 Tel. + 62 21-5512288/5513557 - Fax + 62 21-5513502 Email: [email protected] Email: [email protected]
• KOREA • MALAYSIA
NEOMATE CO. LTD KRUVENT INDUSTRIES (M) SDN BHD 2-1010, Ace High Tech City B/D, 775 Gyeongin-ro, Lot 850, Jalan Subang 7, Taman Perindustrian Subang,
Yeongdeungpo-gu, Seoul, Korea. Postal Code 07299 47500, Subang Jaya, Selangor D.E.
Tel. + 82-2-2679-2052 - Fax. + 82-2-2679-2174 Tel. + 603 80743399 - Fax + 603 80743388
Email: [email protected] Email: [email protected]
• MYANMAR • PHILIPPINES
KRUGER VENTILATION (MYANMAR) CO.LTD KRUGER M&E INDUSTRIES CORPORATION Room No. F21, Thiri Yadanar Whole Sale Market , (Htawunbe) FAPI Compound, E. Rodriguez Ave.
Toe Chae Ward, North Okkalapa Township, Yangon. Tunasan, Munt inlupa City 1773, Philippines
Tel. + 959 763141081/2/3 Tel. + 63 2-8622892/4/6/7, 5534059 - Fax + 63 2-8622891
Email: [email protected] Email: [email protected]
• SINGAPORE • TAIPEI
KRUGER ENGINEERING PTE LTD KRUGER VENTILATION (TAIWAN) CO. LTD No. 10 Buroh Street # 06-06, West Connect Building, No. 157, Ping-an Rd, Hengfeng Village,
Singapore 627564 Dayuan Shiang Taoyuan County 337, Taiwan
Tel. + 65 68631191 - Fax + 65 68631151 Tel. + 886 3-3859119 - Fax + 886 3-3859118
Email: [email protected] Email: [email protected]
• THAILAND • VIETNAM
KRUGER VENTILATION IND. (THAILAND) CO. LTD KRUGER VENTILATION INDUSTRIES (VIETNAM) CO. LTD 30/105 Moo 1, Sinsakorn Industrial Estate, Lot A7. 2-4, C2 Road, Thanh Thanh Cong IZ,
Chetsadawithi Road, Khok Kham Mueng, Samuthsakorn 74000, Thailand Trang Bang Dist. Tay Ninh Province, Vietnam
Tel. + 662 1050399 - Fax + 662 1050370-2 Tel. + 84-276 3585200/01/02 - Fax + 84-276 3585199
Email: [email protected] Email: [email protected]
The company is always improving and developing its products, therefore the company reserves the right of making changes to the illustrated products.
Certified dimension can be provided upon request.
Edition 1
Printed in November 2018
CHINA