Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

43
Validation of Geant4 (V4.2) for GLA ST-LAT - Comparison with Theory, Beam Test Data and EGS4 – S. Ogata, T. Mizuno, H. Mizushima (Hiroshima/SLAC) P. Valtersson, M. Sjogren (Royal Inst. of Tech/SLAC) T. Kamae, H. Tajima (SLAC) (Note) This report covers the work done between Dec. 2000 to Nov. 2001 at SLAC. Note that similar work has been in progress in Italy. Our focus has been in the electromagnetic processes. (Contents) 1. Comparison with Theory 2. Comparison with Results of Beam Test Engineering Model 3. Comparison with EGS4

description

Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 – S. Ogata, T. Mizuno, H. Mizushima (Hiroshima/SLAC) P. Valtersson, M. Sjogren (Royal Inst. of Tech/SLAC) T. Kamae, H. Tajima (SLAC) (Note) - PowerPoint PPT Presentation

Transcript of Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Page 1: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Validation of Geant4 (V4.2) for GLAST-LAT- Comparison with Theory, Beam Test Data and EGS4 –

S. Ogata, T. Mizuno, H. Mizushima (Hiroshima/SLAC)P. Valtersson, M. Sjogren (Royal Inst. of Tech/SLAC)

T. Kamae, H. Tajima (SLAC)

(Note)• This report covers the work done between Dec. 2000 to Nov. 2001 at SLAC. Note that similar

work has been in progress in Italy.• Our focus has been in the electromagnetic processes.

(Contents)1. Comparison with Theory2. Comparison with Results of Beam Test Engineering Model3. Comparison with EGS4

Page 2: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Bethe-Bloch Formula

Default Geant4 parametersused in the study (exception:EM shower study)

Page 3: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Landau distribution (proton1)

Page 4: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Landau Distribution (proton)

Page 5: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Landau Distribution (proton3)

Page 6: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Landau Distribution (Electron1)

Page 7: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Landau Distribution (Electron2)

Page 8: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Mean range (Proton1)

Page 9: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Mean range (Proton2)

Page 10: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Pair Creation (G4 vs. EGS4: Fix needed in G4) No.1

Page 11: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Pair Creation (G4 vs. EGS4: Fix needed in G4) No.2

Page 12: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Moller Scattering (G4 vs Theory: Fix needed in G4?)

Page 13: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Multiple Scattering(G4 vs. BTEM: Proton) No.1

Page 14: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Multiple Scattering(G4 vs. BTEM: Proton) No.2

Page 15: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Average Cluster Size (G4 vs. BTEM: Proton and Positron)

Page 16: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Average Cluster Size (G4 vs. BTEM: Different proton runs)

Page 17: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Average No. Hits (G4 vs. BTEM: Proton and Positron)

Page 18: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Average No. Hits (G4 vs. BTEM: Positron w/ charge sharing)

Page 19: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Average No. Hits (G4 vs. BTEM: Positron w/lower threshold)

Page 20: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Total No. Hits (G4 vs. BTEM: Proton/Positron at 0/30 deg)

Page 21: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Cluster Size (G4 vs. BTEM: Proton at 0 deg: No.1)

Page 22: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Cluster Size (G4 vs. BTEM: Proton at 0 deg: No.2)

Page 23: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Cluster Size (G4 vs. BTEM: Proton at 30 deg: No.1)

Page 24: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Cluster Size (G4 vs. BTEM: Proton at 30 deg: No.2)

Page 25: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Cluster Size (G4 vs. BTEM: Positron at 0 deg)

Page 26: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

No. Hits (G4 vs. BTEM)Positron at 0 deg)

Page 27: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

No. Hits (G4 vs. BTEM)Positron at 30 deg)

Page 28: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Average No. Hits (G4 vs. BTEM: Positron after a cut)

Page 29: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

Average No. Hits (G4 vs. BTEM: Positron study)

Page 30: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

EM Shower (G4 vs EGS4): Cutoff Parameters

Page 31: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

EM Shower (G4 vs EGS4): Geometry1

Page 32: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

EM Shower (G4 vs EGS4): Geometry2,3

Page 33: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

EM Shower (G4 vs EGS4): Energy Leakage after 20RL

Page 34: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

EM Shower (G4 vs EGS4): Longitudinal Profile No.1

Page 35: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

EM Shower (G4 vs EGS4): Longitudinal Profile No.2

Page 36: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

EM Shower (G4 vs EGS4): Lateral Profile No.1

Page 37: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

EM Shower (G4 vs EGS4): Lateral Profile No.2

Page 38: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

EM Shower (G4 vs EGS4): Lateral Profile No.3

Page 39: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

EM Shower (G4 vs EGS4): Lateral Profile No.4

Page 40: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

EM Shower (G4 vs EGS4): Profile near the Core No.1

Page 41: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

EM Shower (G4 vs EGS4): Profile near the Core No.2

Page 42: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

EM Shower (G4 vs EGS4): Parameter Dependence

Page 43: Validation of Geant4 (V4.2) for GLAST-LAT Comparison with Theory, Beam Test Data and EGS4 –

ConclusionValidation of Geant4 (V4.2) for GLAST-LAT- Comparison with Theory, Beam Test Data and EGS4 –

(Note)• This report covers the work done between Dec. 2000 to Nov. 2001 at SLAC. Note that similar

work has been in progress in Italy.• Our focus has been in the electromagnetic processes.

(Conclusion)1. Geant4 is as good as any existing EM simulator now 2. Implement in BFEM G4 and study effects of proposed fixes

(angular distr.)