V O - L E D Job Name Notes Type A D J U S T A B L E … · Painted with a lighting grade baked ......
-
Upload
trinhkhuong -
Category
Documents
-
view
213 -
download
0
Transcript of V O - L E D Job Name Notes Type A D J U S T A B L E … · Painted with a lighting grade baked ......
■ A unique bi-level LED luminairecontrolled by an integral ultra-sonicmotion sensor, designed to providesafe, dependable illumination whileconserving energy. Suitable forceiling or wall mounting
■ Bi-level fixtures operate at a lowstandby light level, offering safetyand security with full light outputinstantly upon occupancy with areasfully lit only as needed
■ Ideal for stairwells, restrooms,laundry rooms and other areas wheremaximum light levels are not requiredon a constant basis
■ For safety and compliance purposesin areas designated as emergencyegress, we recommend choosing astandby light level that will provideminimum code compliant light levelswhile in the standby mode (in mostmunicipalities, this is 1 FC average)
■ Driver integrated adjustable full lightlevel (user selectable) (Low, Med,High) - see chart on back
■ Fixture integrated standby light level(user selectable) 10, 20, 30 or 40% offull
■ DLC qualified when driver switched tolow power setting (factory default)
■ Housings are die-formed of codegauge steel
■ Quality construction throughout forlong-term dependable service
■ Ends are die formed for a clean,smooth look
■ Ample knockouts are provided forconvenient mounting with recessedor surface power feeds
■ Meets ADA requirements for wallmounting
■ One-piece extruded, hightransmission, frosted linear ribbedacrylic is standard for excellent LEDdiffusion and maxiumum light output -see back for options
■ Grooved formation on the edges allowfor a tight, no light leak attachment tothe body
■ High quality MPCB (metal coreboards) are assembled in the USAwith Samsung LEDs ensuring highefficiency and long life. L70 > 85,000hrs
■ All electrical components areU.L. listed or recognized
■ All fixtures are U.L. listed and IBEWunion made
■ High frequency, extremely sensitiveultra-sonic, internally mounted
■ LED status indicator light■ 5 minute walk-test feature, easy-set
time and sensitivity controls,compact design
■ Time delay adjustable to 5, 10, 15 or30 minutes
■ 5 years - part replacement only(Please see our Terms & Conditionspage at www.lamarlighting.com fordetails)
■ Painted with a lighting grade bakedwhite enamel, having a reflectancefactor exceeding 87% for premiumquality and durability
R
Occu-smart is a registered trademark of LaMar Lighting Co., Inc.
Job Name
Catalog Number
Notes Type
V O - L E DS E R I E S
A D J U S T A B L EL I G H T L E V E L
L E DV O Y A G E R
G E N 2 Occu-smart bi-level LED lighting complies with ashrae 90.1-2010 andmeets the requirements of NYC Local law 47*Units must be correctly adjusted to provide required minimum light levels(5000K LED units will charge most photoluminescent tape products)
d i f f u s e r
f e a t u r e s c o n s t r u c t i o n
L E D
e l e c t r i c a l
s e n s o r
w a r r a n t y
f i n i s h
RRU-2 emergency shunt relay(see options on back)
U S A
MADE IN THEMMAA HHEELaMar Lighting assumes no responsibility for misapplication of fixtures
Due to the rapid advancements in LED technology, pleaseconsult our website for the most current technical data.
Revised9/17
SIZE24 - 2’48 - 4’ POWER
A - Adjustable poweruser selectable output powerSee chart below*DLC qualified when driver switched tolow power setting (factory default)
EM - Emergency pack, >90 min., >500 lumensRRU21 - 120V emergency shunt relay (must specify)RRU27 - 277V emergency shunt relay (must specify)
VOL A ASSERIES
VOLFA - Frosted polycarbonatePF - Perforated metal - white
LENSOPTIONS
30 - 3000K35 - 3500K40 - 4000K50 - 5000K
COLORTEMP
AS - User selectable standby options10, 20, 30 & 40% nominal light output(factory shipped 10% standby level)
STANDBYOPTIONS
GENERALOPTIONS
LAMAR LIGHTING 485 Smith Street, Farmingdale, NY 11735 • Tel (631) 777-7700Fax (631) 777-7705 • Outside NY (800) 724-7743 • www.lamarlighting.com
NOTE: SPECIFICATIONS AND DIMENSIONAL DATA ARESUBjECT TO ChANGE wIThOUT NOTICE
BEFORE INSTALLATION, PLEASE CONSULT YOUR LOCALORDINANCES AND BUILDING CODES FOR COMPLIANCE
Fixtures with high frequency or ultra-sonic sensors should berigedly mounted in wind prone areas
Note for glow in the dark exit signs, tapes and other similarproducts: many phosphorescent materials may not properly chargeunder LED light. It is the responsibility of the end user to determinesuitability of the product for their specific application
V O - L E DS E R I E S
A D J U S T A B L E L I G H TL E V E L L E D V O Y A G E Ro r d e r i n g g u i d e
cross sections
d i m e n s i o n a l d a t a
Revised9/17
R
48”
24” 1.125”
3.5”
36”6”
7.8”
.875 KO
6”
4X 0.25”
4’ MODEL
0.25”
.
3.99
2” 2”
0.25”
.960 K.O.MOUSE HOLE
TYP8"
3
Scan QR codeto be directed
to ourhome page!
Due to the rapid advancements in LED technology, pleaseconsult our website for the most current technical data.
2’ VOYAGER 4’ VOYAGER
Full Power
Full Lumens5000K
40% DIM30% DIM20% DIM
Shown4 .953 .90
10% DIM
48W17W13W10W6W
HIGH1140 MA
14W5W5W4W3W
LOW(DLC qualified)
310 MA1495
19W7W6W5W4W
MED440 MA
206025W8W7W5W4W
HIGH571 MA
259225W10W8W6W5W
LOW(DLC qualified)
620 MA2990
36W13W11W8W5W
MED880 MA
4119 5176
Wattages shown are nominal and subject to industry tolerances
24”
7.8”
1.42”12”
5.5”
.250 Mntg Hole x2
5.5”13”
2’ Model
Approx Lumen Multiplier5000K Shown4000K .953000K .90
1
The UL924 listed RRU-2 emergency shunt relay allows emergency luminaires controlled by a 0-10Vdriver or ballast to be automatically illuminated to full brightness during a utility power failure or roompower interruption.
This requires the luminaire to be connected to a generator or invertor protected circuit and the controlmodule to be connected to a standard ‘always on’ circuit.
Protected by one or more US PatentsNos. 7,271,543 & 7,081,715
LaMar Lighting assumes no responsibility for misapplication of fixtures
Consult factory for additional options not shown or listed