V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box...

33

Transcript of V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box...

Page 1: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats
Page 2: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

V. Benda

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 2

Page 3: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

B163 main requirements

• To be recuperated 163 cold box

Fresca

7 Cryostats including their distribution line and 1.9 K pumping system

• New infrastructure 163 combined valve box

Related cryogenic lines• Combined line for Fresca, Fresca 2, Cryostats

• Lines to cold box

• 1.9 K pumping line including heater

• 163/165 transfer line

New 1.9 K pumping unit, 2.3 g/s @ 10 mbar

GHe panel for Fresca 2 and Fresca including He guards

12 000 l LHe Dewar instead the existing 6 000 l LHeDewar if approved

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 3

Page 4: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

B. 163 current state

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 4

Page 5: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

B. 163, elements to be recuperated MEYLSQLH0002

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 5

7 cryostats including the cryogenic

line and 1.9 K pumping system

Fresca

Cold box

Page 6: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

B165 main requirements

• To be recuperated 165 cold box

165 Filling station

• New infrastructure 20 000 l LHe Dewar replacing the existing 5 000 l LHe

Dewar

165 combined valve box

Related cryogenic lines• From 165 CB to 165 combine valve box

• From 165 combined valve box to the Filling station

• From 165 combined valve box to Trailer Dewar

• 163/165 transfer line

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 6

Page 7: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

B. 165, elements to be replaced

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 7

Page 8: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

Common 165 & 163, LN distribution

• Valve box

• Related cryogenic lines

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 8

Page 9: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

Preliminary simplified flow scheme

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 9

163 Dewar6 000 l

165 Dewar 20 000 l

CB 163 CB 165

Trailer Dewar

Fresca Fresca 2

Filling station

7x small cryostats

LPGazo

Gazo LP Gazo

Gazo LP Gazo

Gazo

Valve box 163

Valve box 165

He gas panel F

He gas panel F2

B. 163

B. 165

Cryogenic valves

Warm valves

LP

B. 163

B. 165

Page 10: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

163 Combine valve box

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 10

Combined line: Fresca + Fresca 2

Gazo/LPGazo/LP

Gazo/LP

CB 163

HP GHe

To 7 cryostats

To 165 Dewar

LHe in

LHe out

LHe in

Cold GHe out

Fresca 2 Fresca1.9 K

pumping line

163 LHe Dewar

163 valve box

1 2 3 4 5 6 7 8 9 11 12 13 14 15 16

Fresca 2

1-GHe return, external2-GHe return, internal3-LN in, shield4-CD/WU, external down5-LHe in, external up6-LHe in, internal7-1.9 K LHe in, external8-1.9 K pumping, external9-1.9 K pumping, internal

Fresca

11-1.9 K pumping, internal12-1.9 K pumping, external13-LHe in, internal14-LHe in, external15-GHe return internal16-GHe return, external

HX

MIXMIX

Valve box shield

CD/WU

LN, shield

LHe

GHe return

1.9 K pumping

*On an outlet of 7 cryostats LN line continues directly to 163 CB or to LN phase separator and later on to 163 CB (if content of GN is too high).

*

Gazo/LP

Pre-cooling line

Gazo/LP

22 may 2017

Page 11: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

Fresca 2 simplified schema

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 11

Internal cryostat

Current lead

External cryostat

Current lead

GHe outlet, warm

GHe outlet, warm

2

6

9

1

5

8

7

4

Internal cryostat

2-GHe return, internal6-LHe in, internal9-1.9 K pumping, internal

External cryostat

1-GHe return, external5-LHe in, external up7-1.9 K LHe in, external8-1.9 K pumping, external4-CD/WU, external down & filling

Page 12: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

165 Combined valve box

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 12

CB 165

To filling station

Gazo/LP

Gazo/LP

Line 165/163 pre-cooling

LN

To B. 163

165 Dewar

LHe in

LHe out

LHe in

Cold GHe out

165 valve box

LN

LHe

GHe return

VB shield

Trailer Dewar

Page 13: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

B. 165 existing simplified layout

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 13

Page 14: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

B. 165 proposed preliminary layout

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 14

Page 15: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

B. 163 proposed preliminary layout 3D,a

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 15

Page 16: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

B. 163 proposed preliminary layout 3D, b

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 16

Extra civil

engineering

required

Page 17: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

B.163 combine line at reverse side

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 17

Page 18: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

B.163 combined line at reverse side, top view

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 18

Page 19: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

Building 163 equipment

Approximate mass of components:• Dewar ≈ 9T

• Valve box ≈ 3T

• Fresca ≈ TBC (approx. 20 T)

• Fresca 2 ≈ TBC (approx. 20T)

Mass distribution:• Assuming mass is equally distributed over the area of the pit floor.

• Area of pit = 4.85 m * 2.43 m = 11.79 m²

• Total mass ≈ 50 T

• Distributed mass ≈ 4.24 T/m² (limit = 1T/m²)

Conclusion:• The current strength of the floor of the pit should be confirmed as the drawing is

old.

• If the drawing found is correct civil works may be required to strengthen the pit.

R.GUEYDAN - TE/CRG/ME19/06/2017

Page 20: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

Cryogenic infrastructure for Fresca 2 in B.163

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 20

CB 163

HX

MIX

GN to atmosphere

Warm GHe outlet of CLs

Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line

To 7 cryostats

To 165 Dewar

Page 21: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

Cool down/warm up - external

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 21

CB 163

HX

MIX

GN to atmosphere

Warm GHe outlet of CLs

Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line

Page 22: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

LHe filling - external

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 22

CB 163

HX

MIX

GN to atmosphere

Warm GHe outlet of CLs

Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line

Page 23: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

LHe nominal inlet - external

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 23

CB 163

HX

MIX

GN to atmosphere

Warm GHe outlet of CLs

Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line

Page 24: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

1.9 K pumping - external

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 24

CB 163

HX

MIX

GN to atmosphere

Warm GHe outlet of CLs

Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line

Page 25: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

LHe to internal – cool down & filling

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 25

CB 163

HX

MIX

GN to atmosphere

Warm GHe outlet of CLs

Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line

Page 26: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

LHe internal - nominal

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 26

CB 163

HX

MIX

GN to atmosphere

Warm GHe outlet of CLs

Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line

Page 27: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

1.9 K circuit - internal

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 27

CB 163

HX

MIX

GN to atmosphere

Warm GHe outlet of CLs

Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line

Page 28: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

LN shield circuit

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 28

CB 163

HX

MIX

GN to atmosphere

Warm GHe outlet of CLs

Fresca 2 double cryostat 163 combine valve boxCombine cryogenic line

Page 29: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

Infrastructure for Fresca 2, optionvalves relocation from main valve box to local distribution valve boxes

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 29

Fresca 2, 9 lines Fresca, 6 lines

Fresca 2 distribution valve box, 5 valves

Fresca distribution valve box, 3 valves

163 valve box, 13 valves

To 1.9 K pumping unit

To 163 cold box

To 7 cryostats

To B. 165

163 LHe Dewar

LP

LPLP

Main combined line, 7 lines

F2 combined line. 4 lines

F combined line, 3 lines

Fresca 2

1-GHe return, external2-GHe return, internal3-LN in, shield4-CD/WU, external down5-LHe in, external up6-LHe in, internal7-1.9 K LHe in, external8-1.9 K pumping, external9-1.9 K pumping, internal

Fresca

11-1.9 K pumping, internal12-1.9 K pumping, external13-LHe in, internal14-LHe in, external15-GHe return internal16-GHe return, external

1 23 4 5 6 7 8 9 15 11 12 13 14 16

HP

Page 30: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

Fresca 2 infrastructure - option

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 30

Page 31: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

Fresca 2 infrastructure - option, top view

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 31

Page 32: V. Benda - indico.cern.ch · 15-GHe return internal 16-GHe return, external HX MIXMIX Valve box shield CD/ WU LN, shield LHe GHe return 1.9 K pumping * On an outlet of 7 cryostats

Planning

6/19/2017 163/165 upgrade - Fresca 2, CRG/VB 32

1 week delay in

design phase