(48 X 48) KCN - 448 KCN - 778 (72 X 72) KCN - 998 (96 X 96) KCN - 888 (48 X 96) KCN - 668 (96 X 48) USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models: KCN - 448/778/998/668/888 ) SAFETY INSTRUCTION This controller is meant for counter applications. It is important to read the manual prior to installing or commissioning of controller. All safety related instruction appearing in this manual must be followed to ensure safety of the operating personnel as well as the instrument. GENERAL v The controller must be configured correctly for intended operation. Incorrect configuration could result in damage to the equipment or the process under control or it may lead personnel injury. v The controller is generally part of control panel and in such a case the terminals should not remain accessible to the user after installation. MECHANICAL v The Controller in its installed state must not come in close proximity to any corrosive/combustible gases, caustic vapors, oils, steam or any other process by products. v The Controller in its installed state should not be exposed to carbon dust, salt air, direct sunlight or radiant heat. v Ambient temperature and relative humidity surrounding the controller must not exceed the maximum specified limit for proper operation of the controller. v The controller in its installed state must be protected against excessive electrostatic or electromagnetic interferences. Ventilation holes provided on the chassis of the instrument are meant for thermal dissipation hence should not be obstructed in the panel. ELECTRICAL v The controller must be wired as per wiring diagram & it must comply with local electrical regulation. v Care must be taken not to connect AC supplies to low voltage sensor input. v Circuit breaker or mains s/w with fuse (275V/1A) must be installed between power supply and supply terminals to protect the controller from any possible damage due to high voltage surges of extended duration. v Circuit breaker and appropriate fuses must be used for driving high voltage loads to protect the controller from any possible damage due to short circuit on loads. v To minimize pickup of electrical noise, the wiring for low voltage DC and sensor input must be routed away from high current power cables. Where it is impractical to do this, use shielded ground at both ends. v The controller should not be wired to a 3-Phase supply with unearthed star connection. Under fault condition such supply could rise above 264 VAC which will damage the controller. v The Electrical noise generated by switching inductive loads might create momentary Fluctuation in display, alarm latch up, data loss or permanent damage to the instrument. To reduce this use snubber circuit across the load. SPECIFICATIONS: Display : 4 digit, height 0.56" 4 digit, height 0.39" LED Indications : a] Output (OP1 & OP2) b] Batch c] Auto Reset time No. of Set points : 1 settings : Through Keyboard Range : 1 to 9999 counts 1 to 9999 Batch Reset : a) Front Switch (Programmable) b) Remote Reset (Via Rear terminals) Timing Accuracy : 0.05% Full Scale Repeat Accuracy : 0.01% Outputs : 5 Amp @ 230VAC Relay (1C/O) x 2 Reset : a] Front switch (Programmable) b] Remote Reset (via rear terminals) C] On power interruption(Programmable) 2 Memory : Non-Volatile (E prom) Memory Retention : Up to 10 years Relay Outputs : 5 Amp @230VAC Relay (1C/O) x 2 Sensor Supply : 12 VDC (+10%) @ 50mA Supply : 90 to 270 VAC Mounting : Panel Housing : ABS Plastic O OP. Temperature : O~55 C Humidity : 95% RN (Non Condensing) CONFIGURABLE PARAMETERS: Maximum I/P freq. : (a) Low (For DC I/P) (b) Medium (C) High Count Direction : Up / Down Function : On delay / Off delay Counter Operating : (a) Latch O/P Mode (b) Auto Reset (c) Time Pulse Repeat (TPR) Over Run : Enable / Disable Front Reset : Enable / Disable Hold I/P : Enable / Disable Memory Back up : Enable / Disable Scaler (settable ) : 0.001 to 999 Output 2 Function : a) Auxiliary Contact B) Batch Mode 1 Document Name : OIM KCN-XX8(Ver 2.0) Page 1 of 6

Transcript of USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models…hemtraders.com/images/pdf/KCN-XX8.pdf ·...

Page 1: USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models…hemtraders.com/images/pdf/KCN-XX8.pdf · USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models: KCN ... controller must not

(48 X 48)KCN - 448 KCN - 778

(72 X 72)KCN - 998

(96 X 96)KCN - 888

(48 X 96)KCN - 668

(96 X 48)

USER’S OPERATING MANUAL FOR DIGITAL COUNTER

(Models: KCN - 448/778/998/668/888 )

SAFETY INSTRUCTIONThis controller is meant for counter applications. It is important to

read the manual prior to installing or commissioning of controller.

All safety related instruction appearing in this manual must be

followed to ensure safety of the operating personnel as well as

the instrument.

GENERALv The controller must be configured correctly for intended

operation. Incorrect configuration could result in damage to

the equipment or the process under control or it may lead

personnel injury.v The controller is generally part of control panel and in such a

case the terminals should not remain accessible to the user

after installation.

MECHANICALv The Controller in its installed state must not come in close

proximity to any corrosive/combustible gases, caustic

vapors, oils, steam or any other process by products.v The Controller in its installed state should not be exposed to

carbon dust, salt air, direct sunlight or radiant heat.v Ambient temperature and relative humidity surrounding the

controller must not exceed the maximum specified limit for

proper operation of the controller.v The controller in its installed state must be protected against

excessive electrostatic or electromagnetic interferences.

Ventilation holes provided on the chassis of the instrument

are meant for thermal dissipation hence should not be

obstructed in the panel.

ELECTRICALv The controller must be wired as per wiring diagram & it must

comply with local electrical regulation.v Care must be taken not to connect AC supplies to low voltage

sensor input.v Circuit breaker or mains s/w with fuse (275V/1A) must be

installed between power supply and supply terminals to

protect the controller from any possible damage due to high

voltage surges of extended duration.v Circuit breaker and appropriate fuses must be used for

driving high voltage loads to protect the controller from any

possible damage due to short circuit on loads.v To minimize pickup of electrical noise, the wiring for low

voltage DC and sensor input must be routed away from high

current power cables. Where it is impractical to do this, use

shielded ground at both ends.v The controller should not be wired to a 3-Phase supply with

unearthed star connection. Under fault condition such supply

could rise above 264 VAC which will damage the controller.v The Electrical noise generated by switching inductive loads

might create momentary Fluctuation in display, alarm latch

up, data loss or permanent damage to the instrument. To

reduce this use snubber circuit across the load.

SPECIFICATIONS: Display : 4 digit, height 0.56" 4 digit, height 0.39"

LED Indications : a] Output (OP1 & OP2)

b] Batch

c] Auto Reset time

No. of Set points : 1

settings : Through Keyboard

Range : 1 to 9999 counts 1 to 9999 Batch

Reset : a) Front Switch (Programmable)

b) Remote Reset (Via Rear terminals)

Timing Accuracy : 0.05% Full Scale

Repeat Accuracy : 0.01%

Outputs : 5 Amp @ 230VAC Relay (1C/O) x 2

Reset : a] Front switch (Programmable) b] Remote Reset (via rear terminals) C] On power interruption(Programmable)

2 Memory : Non-Volatile (E prom)

Memory Retention : Up to 10 years

Relay Outputs : 5 Amp @230VAC Relay (1C/O) x 2

Sensor Supply : 12 VDC (+10%) @ 50mA

Supply : 90 to 270 VAC

Mounting : Panel

Housing : ABS PlasticO OP. Temperature : O~55 C

Humidity : 95% RN (Non Condensing) CONFIGURABLE PARAMETERS:

Maximum I/P freq. : (a) Low

(For DC I/P) (b) Medium

(C) High

Count Direction : Up / Down

Function : On delay / Off delay

Counter Operating : (a) Latch O/P

Mode (b) Auto Reset

(c) Time Pulse Repeat (TPR)

Over Run : Enable / Disable

Front Reset : Enable / Disable

Hold I/P : Enable / Disable

Memory Back up : Enable / Disable

Scaler (settable ) : 0.001 to 999

Output 2 Function : a) Auxiliary Contact

B) Batch Mode

1 Document Name : OIM KCN-XX8(Ver 2.0) Page 1 of 6

Page 2: USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models…hemtraders.com/images/pdf/KCN-XX8.pdf · USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models: KCN ... controller must not

MODEL:-KCN-448/KCN-778/KCN-998/ KCN-888/KCN-668

OVER ALL DIMENSIONS & PANEL CUT OUT (IN MM)

TABLE : 1

ModelDim

48

72

96

48

96

48

72

96

96

48

8

10

10

10

10

85

65

65

65

65

44

68

92

92

44

44

68

92

44

92

9

9

9

9

9

A B HC D F GE

43

66

89

43

89

KCN-448

KCN-778

KCN-998

KCN-888

KCN-668

MECHANICAL INSTALLATIONThe label on the controller identifies the serial number, wiring connections and batch number.

INSTALLATION GUIDELINES

1. Prepare the cut-out with proper dimension as shown in figure. 2. Remove clamp from controller 3. Push the controller through panel cut-out and secure the

controller in its place by tightening the side clamp.

E

DC H

A

B

F

G

PANELCUTOUT

ELECTRICAL INSTALLATION

A

B DC H

E

G

FPANELCUTOUT

B

A E

DC H

G

FPANEL

CUTOUT

CAUTION: To prevent the risk of electrical shock, switch off the power before making/removing any connection or removing the controller from its enclosure.

SUPPLY

L

N

1 2 3 4 5 6

7 8 9 10 11 12

15

16

13

14

NO NCCM

RELAY1

SSR1

NO NCCM

RELAY2

1 2 3 4 5 6

10 11 12 13 14 15 16 17 18

7 8 9

NO NCCM

RELAY1

SSR1

NO NCCM

RELAY2SUPPLY

L N

1 2 3 4 5 6

109 11 12 13 14 15 16

7 8

NO NCCM

RELAY1

SSR1

SUPPLY

L N

KCN-778 KCN-998 KCN-668/KCN-888

FRONT PANEL LAYOUT

SSR2

BZR

NO NCCM

RELAY2

SSR2

BZRSSR2

BZR

PNPNPN

+12V +12VI/P1 I/P1I/P2 I/P2GND GNDRST RST +12V I/P1 I/P2 GND RST

NPN

2 Document Name : OIM KCN-XX8(Ver 2.0) Page 2 of 6

SUPPLY

L N

1 2 3 4 5

7 8 9 10

11

12 15

1613

14

NO1 NC1CM1

RELAY1

SSR1

KCN-444

NO

NC

CM

RE

LA

Y2

SS

R2

BZ

R

PNP

+12V I/P1 I/P2 GND RST

6

KCN-668

RL1 RL2 Rt Batch

RST

-counti KCN-94

1

2

43

86 75

KCN-448

RL1 RL2 Rt Batch

RST

KCN-44-Count

1

2

43

86 75

KCN-998

KCN-99-count

RL2

Rt

Batch

RL1

RST

1

2

43

86 75

KCN-888

RL2

Rt

Batch

RL1

-Counti KCN-49

RST

1

2

4

3

8

6

7

5

UpperDisplay

LowerDisplay

STATUSLED

SETKEY

UPKEY

DOWNKEY

SHIFTKEY

NO. NAME FUNCTION

(1) For count Setting. To access Configuration mode at power on. To scroll the parameter & to store its value.

(2) (3)

RL1 Glows when OP1 is ON & RL2 Glows when OP2 is ON. time running. Batch Led Glows when OP2 is configure in Batch mode & flashes while actual batch count display.

Rt Led flashes when Auto reset OR T.P.R

It will display Set count in run mode. Parameter in program mode.(1) (2)

It will display Actual set count in run mode. Sub Parameter in program mode.(1) (2)1

2

3 & 4

5

6

7

8

KCN-778

-count KCN-77

RL1

RL2

Rt

Batch

RST

1

2

43

86 75

(1) To decrease / alter parameter value in program mode. (2) To reset the counter

To increase/alter parameter value in program mode.

To select the particular digit for increment and decrement.

Page 3: USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models…hemtraders.com/images/pdf/KCN-XX8.pdf · USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models: KCN ... controller must not

PARAMETER

DESCRIPTION DEFAULTLOWER

DISPLAYUPPER

DISPLAY

This option doesn't appear if the dot position for scale is at 4th position. User can set screen resolution for RUN Mode.

Resolution

If selected this by the user, In run mode the display will show the counting with out any Decimal Point.

This parameter occurs only if Auto Reset/TPR mode is selected, in Mode1. User can select from Bach/Auxiliary operation for 2nd o/p. In case of latched o/p Auxiliary mode is selected by default.

AUXILIARY: If selected , OP2 can be used as Auxiliary contact. Both the relay output will

ON/OFF together as per the ON/OFF Delay.

nd 2 Output

ModeBatch

NONE

nd 2 Output

BatchEnable

BatchReset

Enable

ENABLE: If selected; when in view mode, user can reset the bach count by pressing down key located at front panel for 3sec.

This feature is useful to avoid unauthorized attempt to reset the bach count during run mode.

This parameter occurs only if bach operation is selected for 2nd o/p. This parameter lets the user enable/disable the bach count reset from down/reset key.

DISABLE: If selected ; user can not reset the bach count by pressing down key located at front panel.

BATCH: If selected , Output2 used as a Batch mod. When Batch count EQUAL S.Bch output2

will on & the output of second relay will remain ON until user press the reset key for 3second

when Batch count displyed.

ENABLE: If selected; when in set mode, user can set the Bach count by using UP/DOWN/SHIFT Key

This feature is useful to avoid unauthorized attempt to change the Bach count during run mode.

This parameter occurs only if bach operation is selected for 2nd o/p. This parameter lets the user enable/disable the Bach count setting in 'set mode'.

DISABLE: If selected; In set mode user can only view the Bach count setting but cannot change the value.

5 Document Name : OIM KCN-XX8(Ver 2.0) Page 5 of 6

By pressing set key in Run Mode display shows batch count. while a showing batch if reset key is pressed than only batch count will reset to zero

Batch ResetCount Reset

If front Reset is enable then after set count by pressing the RST Key count reset to zero & Relay change its status. If reset key is press before set count then only count reset to zero RLY status not changed.

Reset function

Page 4: USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models…hemtraders.com/images/pdf/KCN-XX8.pdf · USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models: KCN ... controller must not

UP Counting Down Counting

On reset display shows 0000. At each count pulse Counter increment count upwards towards the set point. At set point display shows TW value. (If non over run selected)

SET

O

Count Value

On Reset display shows TW Value At each count pluse counter decrement count downwards from the set point to Zero.

SET

O

Count Value

The O/P is energised at the end of the counting cycle. (When the number of pulses received equal to set value) Relay remain on till the unit is reset

UP Counting

SET

O

Count Value

RLY 1

RST

The O/P is energised at the start of the counting cycle and de-energizedat its completion. (When the number of pulses received equal to set count)Relay remain off till the unit is reset.

Up Counting

SET

O

Count Value

RLY 1

RST

ON Delay OFF Delay

Count Direction

Delay Mode

O/P Mode

Over Run mode

In overrun mode the counter continued counting after the set value has been crossed.

2nd O/P Mode

2nd RLY can be configuring as an o/p for a batch counter. In Autoreset or TPR mode,whenever the number of pulses received equal to set value batch counter increments by one. when batch count equals to the set Batch count 2nd RLY energizes & remain on till the unit is reset.

O

RLY 1

SET

a) Auxiliary :- 2nd RLY can be used as a Auxiliary contact.

b) Batch :

After set count display shows TW Value (if UP Counting) or 0000 (if down counting) & Relay changes its status accordingly ON & OFF delay & remain in this condition, until reset key or rear reset pressed. (NOTE : Batch counting is not valid in this mode)

SET

O

Count Value

RLY 1

Latch O/P Mode(up counting & on delay)

Auto Reset Mode

The O/P (relay) changes state (according to the on delay or off delay mode selected) at the end of the count cycle, for the auto reset time after which the counter automatically reset and begins the next count cycle. The unit remains reset for the programmed auto reset time duration and resumes operation after this period has elapsed

SET

O

Count Value

RLY 1AR AR = Auto Reset Time

(up counting & on delay)

After set count RLY changes its status accordingly ON or OFF delay. For a programed pulse time(t) at the end of the count cycle, the count automatically reset & count cycle repeats. Process counting continues uninterrupted during pulse time.

Time Pulse Repeat Mode

(up counting & on delay)

SET

O

Count Value

RLY 1TPRTPR = Time Pulse Repeat

O

RLY 1

SET

RLY 2

6 Document Name : OIM KCN-XX8(Ver 2.0) Page 6 of 6

USER GUIDE

338, New Sonal Link Service Ind. Est. no.2 , Link Road, Malad (W), Mumbai - 400064. Tel: 022-66939916/17. Fax: 022-66939918 E-mail:[email protected] ; Website: innovativeinstruments.co.in

Mfgd by: Innovative InstrumentsPrecision unrivalled

Page 5: USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models…hemtraders.com/images/pdf/KCN-XX8.pdf · USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models: KCN ... controller must not

DelayMode

ON

User can select among ON Delay / OFF Delay Mode described as follows,

ON DELAY: During Counter is in run mode; both Relay O/Ps still remain de-energised(OFF). At the completion of count ; both O/Ps change its state(ON) & remain in that state until user press RESET or next cycle begins(in auto reset mode & TPR mode).

OFF DELAY: During Counter is in run mode; Both Relay O/Ps get energized (ON). At the completion of count ; both relay O/Ps change its state (OFF) & remain in that state until user press RESET or next cycle begins(in auto reset mode & TPR mode).

PROGRAMMINGUSER LIST : To access the user list press SET key once.(All following selected parameter’s code as shown in shaded will be displayed for01 sec. followed by their values / options)

CONFIGURATION MODE: 1. TO ENTER IN THIS MODE: PRESS AND HOLD DOWN "SET" KEY FOR 3 SEC. AT POWER ON.2."CNFG", "LIST" MESSAGE WILL BE DISPLAYED ON UPPER & LOWER DISPLAY RESPECTIVELY AND IT WILL REMAIN STEADY FOR 3 SEC. NOW UNIT WILL ALLOW THE USER TO CONFIGURE DIFFERENT PARAMETERS WITH OPTIONS AS DESCRIBED BELOW. 3. PRESS UP OR DOWN KEY TO SCROLL BETWEEN THE PARAMETER OPTIONS. 4. USE Up/Down/Shift KEY TO SET NUMERIC VALUES OF THE PARAMETERS.ALL FOLLOWING SELECTED PARAMETER CODE AS SHOWN IN SHADED WILL BE ON THE LOWER DISPLAY AND THEIR OPTIONS VALUE WILL BE DISPLAYED ON THE UPPER DISPLAY.

In normal mode, The lower display shows the value of 'set count' while the upper display shows the actual value of count (in accordance with the scale) given at the input terminal. If 'Front reset' is enable than the value of count can be reset by pressing reset/dn key.

In normal mode, Press the 'up' key to view the present value of Bach count. 'B.CNT' will be displayed on the lower display & the present value of 'Bach count' will be displayed on the upper display. The Bach led flashes every 500ms to indicate' view mode'. If batch reset is enabled than the Bach count can be reset by pressing the reset/dn key for 3 sec. Press the 'set' key or wait for 3sec to exit this mode.

Count Direction

UP

Input Frequency

User can select an option from Very Low/Low/Med/High according to the frequency of count pulse at the input terminal. This feature is useful in avoiding noise signal.

PARAMETER

DESCRIPTION DEFAULTLOWER

DISPLAYUPPER

DISPLAY

THIS PARAMETER ALLOWS USER TO SET COUNTING DIRECTION FOR RUN MODE AS FOLLOWS:

UP COUNTING: If selected; counting starts from 0000 up to set count in ascending order.

DOWN COUNTING: If selected; counting starts from set count to 0000 in descending order.

CAUTION: The stored value of count (if any) resets on changing the direction off counting.

SET MODE

RUN MODE

VIEW MODE

PARAMETER

RANGE DESCRIPTION DEFAULT

In RUN mode, Press the 'set' key to set the desired count value. 'S.CNT' will be displayed on the lower display & last stored/default value of 'set count' will be displayed on the upper display. User can change this value by using Up/Down/Shift key. Press the 'set' key to store the desired value & move to next parameter (in case of auto reset ot TPR mode) or the RUN mode. 'Set count' decimal value will be set depending on the screen resolution.

Set Batch

Set Count

0 - 9999

1

This parameter occurs after the above parameter, if 'Auto reset' or 'TPR' is selected as output mode. 'S.BCH' will be displayed on the lower display while the last stored/default value of 'Bach' will be displayed on the upper display. This value can be changed by using Up/Down/Shift key. Press the 'set' key to store the desired value and enters the 'run' mode again.

LOWERDISPLAY

UPPERDISPLAY

D e p e n d s on screen resolution

1

0

0

Count

Bachcount

Dependson screenresolution

LOW

Dependson screenresolution

LOW FREQUENCY: If selected; COUNT INPUT FREQUENCY UP TO 10Hz.

VERY LOW FREQUENCY: If selected; COUNT INPUT FREQUENCY UP TO 3Hz.

MEDIUM FREQUENCY: If selected;; COUNT INPUT FREQUENCY UP TO 100HZ.

HIGH FREQUENCY: If selected; COUNT INPUT FREQUENCY UP TO 1KHz.

3 Document Name : OIM KCN-XX8(Ver 2.0) Page 3 of 6

Page 6: USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models…hemtraders.com/images/pdf/KCN-XX8.pdf · USER’S OPERATING MANUAL FOR DIGITAL COUNTER (Models: KCN ... controller must not

OutputMode

User can select Output mode among LO/TPR/Auto Reset described as follows,

TOGGLE OUTPUT MODE: If selected ; when actual counts reaches its set value ,Relay O/Ps will get l changes its state.

AUTO RESET OUTPUT MODE : When relay contacts change its state after the set value of count has been reached; it will remain in same position & wait for end of auto reset time(it can be set by user). On completion of this time, counter will reset i.e. relay contact positions initialize depending on 'ON' or 'OFF' Delay mode selected &counter will start counting again. There are two different modes of operation in auto reset mode.

PARAMETER

DESCRIPTION DEFAULTLOWER

DISPLAYUPPER

DISPLAY

Mode 2Time

FrontReset

Enable

This parameter lets the user enable/disable the count reset from down/reset key.

DISABLE: If selected; user can not reset the counter by pressing down key located at front

panel. Only remote reset at back terminal is allowed. This feature is useful to avoid unauthorized

attempt to reset the counter during run mode.

ENABLE: If selected; user can reset the counter by pressing down key located at front panel.

Auto ResetTPR OUTPUT MODE: If selected; when relay contacts change its state after the set value of count has been reached; Relays will remain in this state for 'TPR' time (it can be set by user). On completion of this time, relay contact positions initialize depending on 'ON' or 'OFF' Delay mode selected. Unlike Auto reset mode, counting continues during the TPR time. There are two different modes of operation in TPR mode.

MOD1

MODE 2: In TPR Mode2, User ca set two different ON/OFF time for both relay output as per the ON/OFF Delay.

MODE 1: If selected; user can set 'Auto Reset/TPR' time. The On/OFF time for first relay output

is same as 'Auto Reset/TPR' time. In case of auxiliary operation, 2nd relay will have same on/off

time.(if used for Bach operation 2nd relay remains on after set Bach count has been reached)

This parameter occurs only if 'Auto Reset 'or 'TPR' mode is selected. User can select any one of

the two modes described below:

Mode ForTPR Time

OR

This parameter occurs only if Latch o/p mode is selected. User can enable/disable counting after set value of count is reached.

Enable: If selected; counting continues after the set value of count is reached. Only the o/p remains latched thereafter until count is reset.

Disable: If selected; counting stops after the set value of count is reached. The o/p & count remains latched thereafter until count is reset.

Over RunMode

Disable

This parameter appears only if mode 1 is selected. Last stored value of time appears on the upper display. User can set Auto Reset/TPR time by using Up/Down/Shift key. Time can be set to a precision of one decimal point.

Mode 1Time

000.1

This parameter appears only if mode 2 is selected. Last stored value of time1 appears on the upper display. User can set Auto Reset/TPR time1 by using Up/Down/Shift key. Time1 can be set to a precision of one decimal point.

000.1This parameter appears only if mode 2 is selected. Last stored value of time2 appears on the upper display. User can set Auto Reset/TPR time2 by using Up/Down/Shift key. Time2 can be set to a precision of one decimal point.

MemoryBackup EnableEnable

Set DPPoint

User can set position of decimal point for scale factor. The last set value of scale will appear on the upper display & the lower display will toggle b/w “SELt” & “DP” Position of decimal point can be shifted by using the shift key.

0001

ScaleFactor

User can set the value of scale factor. The last stored value of scale with decimal position as set above appears on the upper display. In run mode, on receiving a count pulse the counter will increment count value by the scale factor provided by the user.

0001

DISABLE: If selected; when power fails when counter is running; At the time when power is

restored ; counter will be re-set & counting will restart(depending on the output mode)

ENABLE: If selected ; when power fails during counter is running ; counter will continue

operation from the last count value & relay will be either ON or OFF (depending on mode

selected) at the time when power is restored.

This feature enables user to select memory back up facility at the time of power fail during timer is running.

4 Document Name : OIM KCN-XX8(Ver 2.0) Page 4 of 6