AnyWire POKAYOKE TERMINAL (CC-Link Connection)
User’s Guide
First version 10/November/2009
Anywire Corporation
UMA-0A
○R ○R
i
Caution Items The cautions to this manual
1. This manual should be sends to last user.
2. Please perform operation of this product after often reading this manual and
understanding the contents.
3. This manual explains the functional details included in this product, and does not
guarantee suiting a visitor's specific purpose.
4. Reproducing and reproducing some or of this device without notice refuses.
5. It may change without a preliminary announcement about the contents of this manual in
the future. Warning Indication
"Warning" shows the contents a possibility of getting death or seriously injured is assumed to be, when handling is mistaken. "Caution" indicates that the failure to follow this instruction can result in minor injury or property damage.
In order to use it safely
◆ An AnyWire system is not a thing having a control function aimed for safe security. ◆ When as follows, while having care special about safety measures which
had a margin to rating and a function and to be used, such as a way and fail-safe, carried out, please consult to our company.
(1) The use for which high safety is needed - The use it is predicted to be to have big influence to a human life or
property - Device for medical treatments, device for safe, etc.
(2) When used for the system by which higher reliability is demanded - Use to vehicles control, combustion control device, etc.
� Please be sure to turn off a system before installation or exchange work.
� Please use an AnyWire system within the limits of the specification and
the conditions that were set to this manual.
CAUTION !!!!
WARNING !!!!
WARNING !!!!
ii
◆ Be sure not to turn on the 24V power before completing wiring and connecting in AnyWire System.
◆ Use a regulated power supply of 24V DC. Non-regulated power supply may cause a trouble to the system.
◆ Keep transmission cables and I/O cables away from high-voltage and power cables, though the AnyWire System has high noise margin.
◆ Be careful not to allow metal bits into the unit, the connectors or the terminal blocks, especially when wiring.
◆ Mis-wiring may cause failure. Consider the length and installation of cable wiring to keep connectors and cables from disconnecting or excessive distortion.
◆ Never solder the stranded wire to be connected with the terminal block, otherwise causing a defective contact.
◆ In case of long cable length of power line along the transmission lines, large voltage drops will occur and may cause voltage shortage for the distant Slave Units. In that circumstance, connect the local power supply units so that the prescribed voltage is secured at each local Slave Unit.
◆ Be careful of the following items about installation environment. · No exposing directly to the sunlight and ambient temperature is 0 to +55 ˚C. · Operating relative humidity is 10 to 90 % and no dew condensation by sudden temperature change
· No corrosive or inflammable gases · No direct vibration or impact
◆ Fasten terminal screws securely to avoid malfunction. ◆ In case of storage of the product, keep away from high temperature and
high humidity. (Storage temperature is –20 to 75˚C.) ◆ When the emergency stop circuit or the interlock circuit for safety are
arranged, provide these circuits outside the AnyWire System.
CAUTION !!!!
iii
Contents
1 Target Machines .............................................................................................................................................................1-1
2 Installation Processes ..................................................................................................................................................2-1
3 Transmission Line and Node ...................................................................................................................................3-2
4 AT0 (terminator) ..............................................................................................................................................................4-2
5 Parts Name........................................................................................................................................................................5-1
6 Connection.........................................................................................................................................................................6-1
6.1. CC-Link side (A) ....................................................................................................................................................6-1
6.2. POKAYOKETERMINAL side..........................................................................................................................6-3
6.3. AT0 side ....................................................................................................................................................................6-3
7 General Cautions about installation......................................................................................................................7-1
8 Set to AB023-C1L ....................................................................................................................................................... 8-1
9 Sho-haisen Bus Monitoring Function ...................................................................................................................9-1
10 Basic operating Indication of Each Device................................................................................................ 10-1
10.1. Basic indicator operation of AB023-C1L ............................................................................................... 10-2
10.2. Basic Indication Operation about A027XB-02G2-P......................................................................... 10-4
10.3. Standard indication operation of AT0...................................................................................................... 10-4
11 Attachment pipe of A027XB-02G2-P ........................................................................................................... 11-1
12 Exchanging lever of A027XB-02G2-P ......................................................................................................... 12-1
13 Exchange of Address Setting Switch Cover of A027XB-02G2-P.................................................. 13-1
14 Checklist...................................................................................................................................................................... 14-1
15 Reference..................................................................................................................................................................... 15-1
iv
AnyWire System Warranty
> Warranty period
The warranty of the Product delivered shall continue effective for one (1) year after the delivery
thereof to a location as designated by the original owner.
> Scope of warranty
Should a defect occur in any part of the Product during the foregoing warranty period when it is
used normally in accordance with specifications described in this User's Manual. The
Company shall replace or repair the defect without charge, except when it arises out of:
(1) The misuse or abuse of the Product by the owner;
(2) Other cause than the Product delivered;
(3) The unauthorized alternation or repair of the Product by any person other than the
Company's personnel;
(4) Any unusual force of nature, disasters and other causes beyond the Company's control.
The word "warranty" as used herein, means the warranty applicable to the delivered product
alone, and the Company is not liable for consequential or incidental damages induced by any
malfunction.
1-1
1111 Target Machines
Here is the target machine in this guide.
AB023-C1L (Bit distributed I/O Terminal for CC-Link)
A027XB-02G2-P (Lever changed type POKAYOKETERMINAL)
AT0 (Terminator for AnyWire Bitty series)
1-2
1....AB023-C1L should be used as the CC-Link remote device station
(up to four stations occupied).
2....Use remote register for I/O.
3....Usable transmission signal (DP or DN) cables Use AnyWire dedicated flat cable(Anywire type: FK4-075-100 cable with a size of 0.75mm2/4 wires).
4....Transmission line and power supply
Do not attempt to combine multi-cabtyre cable. It may lead to a malfunction.
Power suppy (DC24V, 0V) to all 027XB-02G2-P and AB023-C1L should be used commonly.
Prepare an AnyWire-dedicated power supply (24-VDC stabilized power supply).
Volatage applied to AB023-C1L should be set within 24V - 27.6V. A measure of power supply capacity(W); [0.035(A)×A027XB-02G2-P number of connection units+0.2(A)]×1.3×24(V)
5....Transmission Distance
Total extension including a branch is up to 100 m.
6....Set to Transmission Speed Set to transmission speed is unnecessary. ( For more details of transmission delay time, refer to User’s Manual of
AB023-C1L)
7....Number of Connecting Units A total of A027XB-02G2-P can be connected 128 units to the AB023-C1L. However, it should be within the number of transmission points can select in four patterns. (it is related to occupied stations of CC-Link). Add AB023-C1L when using more than 128 units. .
!!!! For your continued safety
1-3
→ Refer to Section 8 of Use’s Manual.
8....Terminator This terminator (AT0) contains a circuit that makes a transmission wave. Therefore, it is different between general “registers”. Note that a terminator has polarities. Connect properly.
DP::::White, DN::::Black
→For more details, refer to Section 3.
9....Address setting (Reference)
“Address setting” is the setting where should be allocated to “No. 0” of each terminal from the head address of AnyWire transmission frame. Each A027XB-02G2-P occupies each one point of I/O from the address.
Address is on decimal number system. Make destination number to add switch weight.(set to per one point) Set the address not to be orverlaped.
Ex))))
10....Address automatic recognition operation Operate address automatic recognition before first rststarting when branch
detection function being used.
Transmission of I/O data is operated by conduction.
Address “0” Occupied input # 0 and output # 0 in transmission frame
Address “1” Occupied input # 1 and output # 1 in transmission frame
2-1
2222 Installation Processes
Flow until start-up shows as below as a reference.
System design
Design
Meet terms and conditions
(A total extended distance or address setting)
Selection of connection devices
Set to each unit or connection device
の設置 Install Cables
Set to the maximum transmission distance (transmission clock) of Master Unit
Install and wiring each unit or connection devices
Set to the maximum transmission distance of slave units (transmission
clock) or address
Temporary system start-up (Address automatic recognition)
Error occurred (Error indication)
Setup the system
To change the switch setting, first turn off the power to the system.
4-2
3333 Transmission Line and Node
The number of connecting devices (A027XB-02G2-P) per one system should be in a following
condition.
・Number of connection units: up to 128 nodes
・Transmission line length: a total expanded 100m or less
・Number of a total transmission points:up to 256 points each I/O
No condition of wiring branch. An example of power-efficient configuration is shown below.
4444 AT0 (terminator)
Please keep the following conditions of AT1 connections.
AT0 is a unit for forming transmission waveforms.
Note that an AT0 has polarities. Incorrect connections may cause malfunctions or failures.
Connect a terminator to the transmission line at the farthest end from AB023-C1L in one system.
Connect to the end of terminal if the branch is 40m or more.
The branch over 40m is available up to 2 systems.
4-3
5-1
5555 Parts Name
■AB023-C1L
CC-Link Connection terminal
Station No Setting switch
SET Switch
Monitor Connection Port
MODE Setting Switch
Indicator LED Indicator LED
AnyWire Connection Terminal
5-2
■A027XB-02G2-P
■AT0
Eject Indicator
LINK indication
Eject check switch
Hexagon head bolt, fixed
Fixed tool
Connector for transmission line connection
LED
Cable for transmission line connection AWG18(0.75mm2
) 2 wires Insulation outer diameter Φ2.3
Address setting switch cover
Input indicator of eject check switch
6-1
6666 Connection
6.1.6.1.6.1.6.1. CC-Link side (A)
Connector terminal is attachable easily.
Type: MVSTBW2.5/5-STF-5.08AUM
(Manufactured by Phoenix Contact)
Connectable electric wire: 0.2 - 2.5m㎡ (AWG24 – 12)
Tightening Torque: 0.5 - 0.6N・m
Terminals Signals Line
Color
DA Communication cable Blue
DB Communication cable White
DG Communication Ground Yellow
SLD Shield of communication
cable
-
FG Frame Ground -
* SLD and FG are connected inside the unit.
For more details of CC-Link side of connecting method,
refer to each CC-Link Master Manual.
When detaching “CC-Link side connectors”, check to see that the fixation screws on both ends are
loosened (unplugged from the sockets) before pulling them off.
The devices could be damaged if the connectors are forcedly pulled off while they are still locked.
When installing the device, check to see that there will be no short-circuits due to feasings or
cast-off of the wires and securely tighten the screws at the both ends. (Tightening torque 0.5N-m)
In the case where AB023-C1L is to be the end station, the terminal that is provided with the Master Unit must be attached in between DA and DB. This terminating resistance is needed in addition to the one that is inserted in between DA and DB of the Master Unit. The communication might not be successfully completed on the CC-Link side if not these terminals are not used.
Communication cables and terminal should be crimped together by ferrule. They should be
connected to connectors. Make sure that the cable is not loose and insert to the one terminal.
Otherwise, the cable may come off the connector.
Screw, fixed
AAAA
6-2
Sho-haisen Bus side (B)
Terminal board is 8-pole-M3 terminal board.
Connectable electric wire: AWG22 - 14
Tightening Torque: 0.8N・m
24V
0V
Connect to DC24V stabilized power supply.
35mA×number of connecting units of A027XB-02G2-P+200mA]×the
capacity must be more than 1.3×24V
DP Transmission line (positive side)
DN Transmission line (negative side)
LG Connected to the neutral point of the noise filter.
Ground if any malfunctions due to the 24V related power source noise are
experienced.
In that case, the grounding work of Class D rating must be conducted
individually.
6-3
6.2.6.2.6.2.6.2. POKAYOKETERMINAL side
A027XB-02G2-P is attached LP connectors.
Wiring is set by insulation displacement contact in any position of dedicated flat cable
(FK4-075-100) and being combined with connector of A027XB-02G2-P. LP connector
(LP4-BK-10P) can be branch or linking between the same types of connector.
For more details of insulation displacement contact work, refer to “Link Connector insulation
displacement method of Flat Cable.
6.3.6.3.6.3.6.3. AT0 side
To operate insulation displacement contact of a link connector to the end of AT0 cable.
It is recommended that dedicated tools use.
For more details of insulation displacement contact, refer to “Link Connector insulation
displacement method of Flat Cable”.
LP connector PIN
No. Contents
AT0 cable
color
1 DN Black
2 DP White
LP connector of the unit side (attached)
LP connector (LP4-BK-10P), the trunk side of Sho-haisen Bus
Use of LP connector (LP4-OR-10P)
6-4
3 Spare -
4 Spare -
7-1
7777 General Cautions about installation
� Select the terminal board and connector according to the kinds of cables or purpose of usage. � Check to see whether the core wire color for connecting the cable is correct. � Do not reuse the connector that has been crimped once as this may lead to contact failure. � Related devices should be turned off when:
- mounting devices or units - detaching devices such as Master units or slave units - setting or changing address - processing or connecting cables - connecting I/O devices, including sensors or actuators
� Always cables in AnyWire System away from high-voltage and power cables. (recommended avoiding 100mm or longer)
� Do not use cable with coiling as transmission condition may not be guaranteed.
* Do not use plural transmission Line (D, G) with many cable lines together. It has the possibility that the equipment operates faultily due to the cross talk when it is transmitted together.
G
G
D
D
G
G
D
D
* Set the diameter of the transmission line at more than 0.75 mm2. * Connect to DP or DN properly. * Be careful of the voltage drop by the cable. Equipment operates faultily due to the voltage drop. * A line to connect to the connector terminal isn't to do solder. A line causes a looseness contact defect
� MONITOR Connector
This connector is for connecting maintenance monitor.
System 1 System 1
System 2 System 2
8-1
8888 Set to AB023-C1L
CC-Link side setting((((C))))
Station number is set by “Station No.” setting switch (C).
It can be set from 1 to 64.
If the node address is the same as that of another node, a duplicate node address error occurs,
making it impossible to establish communication.
Maximum setting stations by number of occupied stations are
shown below.
Communication speed is set by “B. RATE” setting switch (D)(D)(D)(D).
When set “5” or more, “ERR” LED is flashing.
Sho-haisen Bus side setting (D)
The transmission distance can be selected using MODE setting switch.
(The following “SW-*” responds to labels 1-6).
SW-2,1 Set a transmission points (=occupied station number) by ON/OFF of switch-1 or 2.
“ STATION No.” setting switches STATION No.
×10 ×1
1 0 1
2 0 2
3 0 3
・ ・ ・
62 6 2
63 6 3
64 6 4
Number of
occupied stations Maximum Setting Station Number
1 64
2 63
3 62
4 61
B.RATE
Setting Switch Communication speed
0 156Kbps
1 625Kbps
2 2.5Mbps
3 5Mbps
4 10Mbps
5 -F Error
DDDD
CCCC
8-2
SW-3-6 Reserved. Use when the setting is OFF.
MODE
setting
switches
Number of Transmission
points
1 2 Input Output Total
Number of CC-Link
occupied stations
OFF OFF 256
points
256
points
512
points 4
ON OFF 192
points
192
points
384
points 3
OFF ON 128
points
128
points
256
points 2
ON ON 64
points
74
points
128
points 1
Always turn off the power before setting the DIP switches.
Setting changes when applying current are not valid.
9-1
9999 Sho-haisen Bus Monitoring Function
Summary
AB027-C1L has a memory function to memorize the address of A027XB-02G2-P connected to
AB027-C1L to E2PROM. This memory information has been stored when power is turned off.
This memorized address is sent sequentially during operation. If there is no response from
A027XB-02G2-P, “ALM” LED indicates as disconnection. By using this function, it is possible to
disconnection detection if transmission line is branched.
Automatic Address Identification((((E))))
”Automatic Address Identification” is the operation to have the addresses
of connected Slave Units memorized in E2PROM.
Procedure
1. Check to see that all the Slave Units are properly operating.
2. Press “SET” Switch until the “SET” LED (orange) is lights up.
3. Address memorization is completed when the “SET” LED are flashing
(Flashing quickly) after it has lit for a while.
“Address automatic recognized order as following situations.
- When all A027XB-02G2-P are connecting and operating.
- When A027XB-02G2-P are added.
- When address of A027XB-02G2-P are deleted
- When address of A027XB-02G2-P are changed.
� Input/Output might not be possible while Automatic Address Identification is in operation.
Operate Automatic Address Identification in the condition that will not interfere with the
operation of devices such as to stop the PLC Program execution, etc.
� Automatic Address Identification does not operate when there are any errors of Sho-haisen Bus
or for approximately five seconds after tuning on the power or resetting the error status.
� Do not operate address automatic recognition when disconnection error is occurred in operation.
The information of disconnection may be lost.
Monitoring operation
The addresses registered will be sent out one by one and when the response is not returned, it will be
displayed as disconnection by “ALM” LED.
This error information will be retained until the power is turned off or error status is reset.
(Refer to section “LED Indications”.)
EEEE
10-1
10101010 Basic operating Indication of Each Device
Status indication (F)
Each device has monitor indication for operating state. Check that each device work properly after
connection and conduction.
Each setting or connection may correct, device indicator shows in the table below.
Indication Status Indication Status
RUN Lights
up LINK Flashing
ERR Goes
out RDY
Lights up
SD Lights
up SET
Goes out
CC-Link side
RD Lights
up
Sho-haisen Bus side
After checking this status, operate “Automatic address recognition” and register connecting terminal.
(See User’s Manual of AB023-C1L.)
In the beginning of conducting, “LINK” indication turns on "Lights up". It means
A027XB-02G2-P is not registered by “Automatic address recognition”.
When registered “Automatic address recognition” operation, disconnecting monitoring function of transmission
line becomes effective.
Data transmission is operating regardless “Automatic address recognition”
After operating “Automatic address recognition”, “LINK” indicator turns on "Flashing". It means
operating in normal status. In the case of indicated status other than those listed above, remove the
failure according to the following contents.
FFFF
10-2
10.1.10.1.10.1.10.1. Basic indicator operation of AB023-C1L
Green LED shows the operation of normal status. ■ Status of CC-Link-side Indicators
LED Lights up Goes out Flashing
RUN
(Green) Successfully transmitting
Transmission cable is disconnected. Transmission cable wiring is wrong. Transmission speed Setting is wrong. The hardware is being reset.
-
ERR
(Red)
− CRC Error − Error detected in Station Setting SW (Set to either 0 or any number larger than 62) − Error detected in Baud Rate SW Setting • (Set to any number larger
than 5)
Successfully transmitting The hardware is being reset.
When Baud Rate or
station number switch
changed from the setting
of reset (flashing for four
second), restore setting
and then may go out.
SD
(Yellow) Sending Data
−Transmission cable is disconnected. − Transmission cable wiring is wrong. − Transmission speed Setting is wrong. The hardware is being reset.
-
RD
(Yellow) Sending Data
− Transmission Cable is disconnected. − Transmission Cable wiring is wrong. The hardware is being reset.
-
■Indication of the status of Sho-haisen Bus
Indication Name Color Meanings
Lights
up
This unit is in operation.
RDY Ready Green Goes
out
The power is not supplied, or this unit is faulty.
Flashing Data is being transmitted normally.
LINK Transmission
distance Green Goes
out
This unit is faulty.
SET Automatic
address Orange
Lights
up
Automatic address recognition is in progress.
10-3
Goes
out
Data is being transmitted normally. recognition
indication
Flashing The recognized address is being written to
EEPROM.
Confirm the next first.
(1) The "RDY" LED of AB023-C1L should be lighted on.
(2) The "LINK" LED of all POKAYOKETERMINAL (A027XB-02G2-P) should be flashed.
(3) The power supply voltage of AB023-C1L should be a thing in a range of 24 - 27.6V.
(4) Wiring and connection should be certain.
(5) The address establishment should be accurate, not overlapping.
(6) Use transmission line with a size of at least 0.75mm2.
(7) Total extension of transmission length should be up to 100m.
(8) Umber of connecting units of POKAYOKETERMINAL (A027XB-02G2-P) should be up to 128
units and used points should be up to 256 points.
10-4
10.2.10.2.10.2.10.2. Basic Indication Operation about A027XB-02G2-P
A027XB-02G2-P has a monitoring function.
LINK lamp indicates a system status.
Eject indicator lamp indicates an eject position in green.
■Indications of Sho-haisen Bus side
10.3.10.3.10.3.10.3. Standard indication operation of AT0
When transmission signal is received in normal connecting status,
Red LED (J) lights up (low brightness).
Indicate LED Indicate
status Monitor contents
Flashing Transmission
signal reception
Turn Lights
up LINK: Red (G)
Goes out
Disconnection of
power,
Transmission
error
(Disconnection or
short-circuit)
Lights up Eject indicator lamp:Green
(H) Goes out Eject order
IIII
GGGG HHHH
10-5
JJJJ
11-1
11111111 Attachment pipe of A027XB-02G2-P
POKAYOKETERMINAL (A027XB-02G2-P) is attachable to Φ28 pipe. (ex: creform or creform pipe
of Yazaki Kako Corporation).
[1] Hook the boss of fitting B onto the Hinji part of the body.
[2] Hook fitting B onto the pipe, and then pull the body to make the connection. When the body pawl snaps into the flute of fitting B, a temporary fixing has been made.
[3] Slide to the body and adjust the position.
[4] Once the position has been determined, fasten fitting B to the pipe with the provided bolts. M6 bolt Tightening Torque: 1.5 -2N・m
Body
Fitting B
Hinji part
Flute of Fitting B
Body tab
Hexagon head bolt (M6×15) attached with one on the body
Pipe
12-1
12121212 Exchanging lever of A027XB-02G2-P
“Rubber lever” of eject recognized switch of A027XB-02G2-P is changeable.
Changing procedure is as follows.
[1111] Disinstallation of Rubber Lever
Rubber lever holding ring
Rubber lever
Front view
●
(1) Put a black part of rubber lever holding ring to direction B and loosen the ring after removing a mating.
Rubber lever fixture
[1] Rubber lever
[2] Rubber lever holding ring
(2) Remove the rubber lever in numerical order, [1] → [2].
12-2
[2] Installation of Rubber Lever
Rubber lever fixture
[1] New rubber lever
[2] Rubber lever holding ring
■Exchange rubber lever set Type: A027XB-LSE-06B-01-5P (Packs of 5 sets)
Rubber lever
Rubber lever holding ring
[1]Put a new rubber lever in holing fitting properly and put a tuber lever holding ring through a lever. Use new holding ring.
Rubber lever Holding ring attach position (D)
Rubber lever
Mating status at tightening
Rubber lever holding ring
External diameter of
rubber lever
(2)Attach a rubber lever holding ring to a position on the front side. After tightening, check that lever is fixed properly.
Front view
13-1
13131313 Exchange of Address Setting Switch Cover of A027XB-02G2-P
Exchange address setting switch covers which are lost or damaged for new one. Attachment
method is as follows.
Address setting switch cover is opened when it slides to the left. And the cover is removed when
it slides more. When attached switch cover, put the cover flitter in the main body’s rail and slide to
the right.
Address setting switch cover
Open
Put a pawl of the part of ○ in a rail and slide it.
Cross-section view
Put a tab of cover one by one.
14-1
14141414 Checklist
Main check items are as follows.
[1] Link indicator of A027XB-02G2-P does not light up. It may have a loose connection of transmission line.
・Is selected proper connector for cable size?
・Do all hooks of insulation displacement contact of LP connector put properly?
・Do connectors put each other properly?
・Is screw terminal board of AB023-C1L loosen?
A027XB-02G2-P connection may be improper.
・Are 128 units or more connected?
・Eject indicator does not light up.
[2] Eject indicator lamp of A027XB-02G2-P is flashing at random times. Transmission signal is not reached to predetermined duration or voltage as a result of
external factor.
・Is a total length of transmission lines up to 100m?
・Is the voltage being supplied to AB023-C1L low?
・Is power capacity being supplied to AB023-C1L not enough?
・Is A027XB-02G2-P set properly?
[3]Input signal of eject check switch of A027XB-02G2-P does not turn on. Transmission signal is not reached to predetermined duration or voltage as a result of
external factor including a failure of lever.
・Is a lever of eject check switch broken?
・Are input CH number or bit position correct?
・Is the total length of transmission lines over 100m?
・Is the voltage being supplied to AB023-C1L low?
[4] Error information on AB023-C1L Indications about CC-Link
Communication is completed if both SR and RD light up.
In the case of indicated pattern other than those listed above, remove the failure according to the
table of section 10.1.
Indication about AnyWire
Receiving and sending of transmission signal is completed if RDY lights up or LINK is flashing.
Remove the failure as following section 10.1if LINK may light up or flash.
[5] LED of AT0 does not light up.
Connection of DP and DN is connected properly or transmission signal id no reached.
Check if the cable wirings are correctly completed.
****If there are problems other than those listed above, contact us.
15-1
15151515 ReferenceReferenceReferenceReference
Parameter Setting is required in order for the communication between Master Station and Remote I/O
station, remote device station as well as local station on CC-Link.
A parameter setting example of AB023-C1L (remote device station) is shown below:
Moreover, refer to “CC-Link System Master/Local Unit User’s Manual (detailed version)” and related documents by Mitsubishi Electric.
1. Parameter setting example by CPU of Q series
CC-Link Master Unit : The head I/O number is “0”.
AB023-C1L : When station number is “1”.
A1S62PN
A2USCPU
A1SJ61BT11 CC-Link Master unit X/Y00 - X/Y1F
Ver.1.1
CC-Link Bit distributed I/O terminal AB023-C1L Station No. 1 (Set to four stations occupied from the station No 1 to No 4.)
15-2
CC-Link parameter can be set from the Parameter Setting Screen of Programming Software GX
Developer on the Q CPU, QnA, Q4AR, QnAS or QnASH CPU.
[Setting Example] Check the [Project Data List] on the Displayed Menu. The screen shown below will appear by clicking
[Parameter] → [Network Parameter] → [CC-LINK] in the displayed Project Window.
Enlarged screen of what is shown in the frame will be shown in the next section.
15-3
■when connected to AB023-C1L (one unit)
Set each field to meet the specification of the system that is used by the customer.
Setting Items Contents
Head I/O No. Input the head I/O number that the CC-Link is attached by the unit
of 16 points.
Mode setting Select from remote net-ver.1 mode, remote net-ver.2 mode and
Remote Net – Additional mode to meet the customer’s system.
The total Number of Connections Input the total number of units that include the reserved stations
and inactivated stations in the range from 1 to 64. Remote Input (RX) Refresh Device
Enter the device name and device number of X, M, L, B, D, W, R
and ZR. Remote output (RY) Refresh device
Enter the device name and device number of Y, M, L, B, T, C, ST,
D, W, R and ZR. Remote Register (RWr) Refresh
Device
Enter the device name and device number of M, L, B, D, W, R,
and ZR
Remote Register (RWr) Refresh
Device
Enter the device name and device number of M, L, B, T, C, ST, D,
W, R and ZR. Special Relay (SB) Refresh
device
Enter the device name and device number of M, L, B, D, W, R, SB
and ZR. Special Register (SW) Refresh
device
Enter the device name and device number of M, L, B, D, W, R,
SW and ZR.
15-4
■Station Information Setting [Station Information Setting] Window shown below will open by a double click on [Station Information].
Set [Station Type] to [Remote Device Station] and [Occupied Number of Station] to [4-Station
Occupation].
The response of each signal and device are shown below.
Signals Corresponding device
Error flag X17A note 1)
Error reset required flag Y17A note 2)
Input (256 points) M0 - M255
Output (256 points) M400 - M655
Input and output are provided by the remote register. In this case, MO - M255 are for inputs and M400 -
M655 are for outputs. X100 - X17F and Y100 – Y17F are occupied when X17A is used as error status
flag and Y17A is used as error reset required flag. note1), note2)
15-5
■When connected to AB023-C1L (2 units)
The response of each signal and device will be as are shown below.
Signals Corresponding device
station No. 1
Corresponding device
station No. 5
Error status flag X17A note 1) X1FA note 1)
Error reset required flag Y17A note 2) Y1FA note 2)
Input (256 points) MO - M255 M256 - M511
Output (256 points) M800 - M1055 M1056 - M1311
Input and output are provided by the remote register. In this case, MO - M511 are for inputs and M800
–M1311 are for outputs. X100 - X1FF and Y100 – Y1FF are occupied when X17A is used as error
status flag and Y17A is used as error reset required flag. note1), note2)