User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power...

24
User’s Manual Before using the inverter, you need to read and save the safety instructions.

Transcript of User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power...

Page 1: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

User’s Manual

Before using the inverter, you need to read and save the

safety instructions.

Page 2: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert
Page 3: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

SHI 400 / SHI 600 / SHI 1000

Pure Sine Wave Inverter

The information presented in this document does

not form part of any quotation or contract, is believed

to be accurate and reliable and may be changed without

notice.

Page 4: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

TABLE OF CONTENTS

1. Introduction ................................................... 1

2. Mechanical Drawings .................................... 2

3. Important Safety Instructions ........................ 5

4. Inverter Operation ......................................... 6

5. Function ......................................................... 7

6. Troubleshooting ........................................... 13

7. Maintenance ................................................ 14

8. Technical Specification ............................... 15

Page 5: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

1

1. Introduction

Thanks for purchasing our company’s power inverter of SHI series.

The product is a sine wave power inverter which can convert

12V/24V/48V DC to 220V AC (50Hz/60Hz) based on high performance

DSP full digital and intelligent design. It has the features of high

reliability, high efficiency, low weight, small volume, full protection

functions, easy installation and operation. The inverter can be applied in

many fields especially for solar photovoltaic power system.

Powerful DSP digital and intelligent design

Wide DC input voltage range

Pure sine wave output with high efficiency and stability

Excellent EMC design

Low output harmonic distortion(THD≤3%)

Two on-off control mode: local main switch and remote control

switch

LED indicators for input voltage range, load power range, normal

output & failure state

Load short-circuit, overload, input voltage under/over and

over-temperature protections and alarms, inverter’s inner fault

protections.

RS-232 communication interface connecting with PC or other control

and monitor device.

Fitted for many kinds of AC loads such as household appliances,

electric tools and industrial devices

Wide working temperature range (industrial level)

Page 6: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

2

2. Mechanical Drawings

SHI 400

(Unit: mm)

Page 7: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

3

SHI 600

Page 8: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

4

SHI 1000

Page 9: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

5

3. Important Safety Instructions

As an AC power supply equipment, the inverter’s output voltage is

with the same level as that of household power plug. Mind the AC output

terminals, or you may get an electric shock!

Attentions:

Connect the DC input according strictly to the requirement. The

power inverter has a relatively wide input range, but too high or too

low input may cause problems even destroy the inverter.

Do not expose the inverter to humid, flammable, explosive or dust

environment. Do not install the inverter in airproof location and keep

enough space around the inverter.

Make sure the air ventilation clearance around the inverter is more

than 10cm, for when the inverter works continuously its surface may

became very hot. Keep away from the material or device which may

suffer from high temperature when the inverter is working.

Connect the load devices to the AC output outlet, then the DC input.

Make sure both the input and output connects are correct, switch on

the inverter first and then turn on the load.

Do not connect the battery charger or similar devices to the input

terminal of the inverter.

Do not put the inverter close to the open lead-acid battery because the

sparkle in the terminals may ignite the hydrogen released by the

battery.

Do not attempt to repair the fault inverter yourself, otherwise it may

lead to a serious accident. Please connect the manufacture’s engineer.

Page 10: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

6

4. Inverter Operation

Connect the input and output terminals accurately by referring to the

previous chapter. Use the ON / OFF switch on the front panel to turn the

power on. Turn AC loads on one by one after the output of the inverter is

normal, in order to prevent protections resulted from the surge power.

Set the power switch to the OFF position.

Insert the load’s plug into the inverter’s output outlet.

Connect the battery(‘+’ terminal with red line,’-‘ with black line). Do

not connect them by contraries, or it will damage the power inverter.

Switch the inverter to ON and then turn the loads on one by one.

Check the operation state of both power inverter and loads. ‘Green’

of the LED indicator means the state is normal.

If there are different loads, it is suggested that turn on the load with

large startup current first, such as television, then turn on the load

such as lamp when the inverter works stable.

If the failure LED indicator is ‘Red’ and the buzzer alarms or no

output when you turn on devices, switch off the loads and power

inverter immediately. Check the system by referring to the

troubleshooting guide. Turn on the devices again according to the

operation methods after the failure is removed.

Page 11: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

7

5. Function

DC Input Panel

Protective Earth Ground

Fan Ventilatio

n

DC Input Terminal

NEG

DC Input Terminal

POS

SHI 400 / SHI 600:

Protective Earth Ground

Fan Ventilatio

n

DC Input Terminal

POS

DC Input Terminal

NEG

SHI 1000:

Page 12: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

8

AC Output Panel

Power Supply

Switch AC Outlet Monitor Port

(RS-232)

LED

Indicators

SHI 400 / SHI 600 / SHI 1000:

Page 13: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

9

Input Level: Display Input Voltages

LED Status Nominal input

12V DC

Nominal input

24V DC

Nominal input

48V DC

RED

Slow Blink <10.8 V <21.6 V <43.2 V

RED 10.8~11.25 V 21.6~22.5 V 43.2~45.0 V

ORANGE 11.25~12.0 V 22.5~24.0 V 45.0~48.0 V

GREEN 12.0~14.5 V 24.0~29.0 V 48.0~58.0 V

ORANGE

Fast Blink 14.5~16.0 V 29.0~32.0 V 58.0~64.0 V

RED

Fast Blink >16.0 V >32.0 V >64.0 V

Load Level: Display AC Loads(Watts)

LED Status SHI 400 SHI 600 SHI 1000

OFF <20VA <30VA <50VA

GREEN 20VA~240 VA 30VA~360 VA 50VA~600 VA

ORANGE 240VA~320 VA 360VA~480 VA 600VA~800 VA

ORANGE

Slow Blink 320VA~360 VA 480VA~540 VA 800VA~900 VA

RED ≥360 VA ≥540 VA ≥900 VA

RED

Slow Blink Overload

RED

Fast Blink Short Circuit

Page 14: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

10

Output & Fault Status

LED Status Status

GREEN Output Ok

RED Fast Blink Overload or Short circuit, Output Off

RED Slow Blink Over or Low input voltage, Output Off

ORANGE Fast Blink Over temperature, Output Off

RED Inverter Fault, Output Off

OFF Power Off or Power Saving Mode,Output Off

Alarms

Alarms Status

Buzzer Sounds

Overload or Short circuit, Output Off

Over or Low input voltage, Output Off

Over temperature, Output Off

Inverter Fault, Output Off

Page 15: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

11

Protections

Output Short Circuit Protection

The inverter switches off the output immediately when the

connecting load is short. Then it recovers the output automatically

after delaying 5 seconds. If the short circuit status still remains when

the inverter tries to recover for three times, you should clear the load

faults then restart the inverter manually or by remote mode.

Overload Protection

The inverter switches off the output after working for 30, 5 and

1.5 seconds when the load power is over 125% of rated value, 150%

of rated value and 200% of rated value respectively.

Input Low Voltage Protection

The output is switched off when the input voltage is low than

90% of the rated value.

Input Over Voltage Protection

The output is switched off when the input voltage is over than

133% of the rated value.

Fault Protection

The inverter will shut down when the output voltage falls below

176V, or above 264V or when the inverter has inner fault.

Page 16: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

12

Over Temperature Protection

The inverter will shut down when the power device’s

temperature is over 75℃.

Fan Ventilation

The fan runs when the output power is more than 5% of rated

value.

Page 17: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

13

6. Troubleshooting

WARNING:

High voltage is inside the inverter, do not open or disassemble

it! Attempting to service the unit yourself may cause the risk of

electrical shock or fire!

Problem Possible Cause Solution

Input LED

blink, fault red

LED slow blink

Input voltage is

too high or too low

Measure the input voltage. The

inverter recovers when the

input becomes normal.

Load LED

blink, fault red

LED fast blink

Overload or load

short

Check out if the AC load is

within the rated power or

whether there is load short.

Fault orange

LED fast blink

Over temperature

inside the inverter

Improve the quality of

ventilation and do not block

the vents. Restart the inverter

when it is cool down.

Fault red LED Inverter

abnormal

Remove all the connected

plugs then restart. If inverter

works well, please check the

load and line. If the LED

keeps red, the inverter has

inside faults and should be

returned to the factory

Page 18: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

14

7. Maintenance

You must do regular proper maintenance on inverter.

You should clean the cover regularly with a cloth to prevent

accumulation of dust and dirt, tighten the screws on the DC input

terminals.

The warranty period of this product is one year from the date of

original purchase. This limited warranty is void if the unit is abused,

modified, installed improperly, or had its housing removed. The

manufacture is not liable for damages arising from the use, misuse, or

operation of this product.

During the warranty period, defective units will be repaired or

replaced (with the same or a comparable model).

Please properly keep the maintenance card for after-sale service.

Page 19: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

15

8. Technical Specification

DC Input

Model SHI 400

/12-220

SHI 400

/24-220

SHI 600

/12-220

SHI 600

/24-220

SHI 1000

/24-220

SHI 1000

/48-220

Input rated

voltage

12V 24V 12V 24V 24V 48V

Input voltage

range

10.8-16

VDC

21.6-32

VDC

10.8-16

VDC

21.6-32

VDC

21.6-32

VDC

43.2-64

VDC

No-Load

Current

≤1300

mA

≤600

mA

≤1200

mA

≤600

mA

≤1000

mA

≤600

mA

AC Output

Model SHI 400/12-220

SHI 400/12-220

SHI 600/12-220

SHI 600/24-220

SHI 1000/24-220

SHI 1000/48-220

Output Voltage 220V±5%

Rated Power 400VA 600VA 1000VA

Maximum Short

Time Power 600VA 5s 900VA 5s 1500VA 5s

Surge Power 800VA 1.5s 1200VA 1.5s 2000VA 1.5s

Output Mode Single phase

Frequency 50Hz±2%

Load Power Factor COSθ-90°~ COSθ+90°

Output Waveform

Distortion THD≤ 3%

Efficiency at Rated

Power ≥90%

Page 20: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

16

Mechanical parameters

Model SHI 400/12-220

SHI 400/12-220

SHI 600/12-220

SHI 600/24-220

SHI 1000/24-220

SHI 1000/48-220

Exterior

(L*W*H mm) 273×158×71.5 304×175×71.5 370×201×90.5

Installation

(L*W mm) 210×146 196×164 207×189

Net weight (kg) 2.2 2.65 4.35

Environmental parameters

Working Temperature -20℃~+55℃

Storage temperature -25℃~ +60℃

Altitude < 5000 m

Relative Humidity < 90%(non-condensation)

Page 21: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert
Page 22: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert
Page 23: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert
Page 24: User’s Manual · 2013-04-23 · 1 1. Introduction Thanks for purchasing our company’s power inverter of SHI series. The product is a sine wave power inverter which can convert

BEIJING EPSOLAR TECHNOLOGY CO., LTD.

Tel: +86-10-82894112 / 82894962

Fax: +86-10-82894882

E-mail: [email protected]

Website: http://www.epsolarpv.com/