User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A...

19
Part Number: 31505548 RMS-RELAY01A User Manual Issue 05 Date 2015-12-25 HUAWEI TECHNOLOGIES CO., LTD.

Transcript of User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A...

Page 1: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

Part Number: 31505548

RMS-RELAY01A

User Manual

Issue 05

Date 2015-12-25

HUAWEI TECHNOLOGIES CO., LTD.

Page 2: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd. i

Copyright © Huawei Technologies Co., Ltd. 2015. All rights reserved.

No part of this document may be reproduced or transmitted in any form or by any means without prior

written consent of Huawei Technologies Co., Ltd.

Trademarks and Permissions

and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.

All other trademarks and trade names mentioned in this document are the property of their respective

holders.

Notice

The purchased products, services and features are stipulated by the contract made between Huawei and

the customer. All or part of the products, services and features described in this document may not be

within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements,

information, and recommendations in this document are provided "AS IS" without warranties, guarantees or

representations of any kind, either express or implied.

The information in this document is subject to change without notice. Every effort has been made in the

preparation of this document to ensure accuracy of the contents, but all statements, information, and

recommendations in this document do not constitute a warranty of any kind, express or implied.

Huawei Technologies Co., Ltd.

Address: Huawei Industrial Base

Bantian, Longgang

Shenzhen 518129

People's Republic of China

Website: http://e.huawei.com

Page 3: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual About This Document

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

ii

About This Document

Purpose

This document describes the RMS-RELAY01A card in terms of its appearance, functions,

ports, and installation. The card is an optional communications component of the

UPS2000-G-(6 kVA–20 kVA), UPS2000-A-(6 kVA–10 kVA), and UPS5000-A-(30 kVA–120

kVA). UPS is short for uninterruptible power system.

The Modbus card has an exquisite, advanced, and unique design, and features high

performance and reliability.

Intended Audience

This document is intended for:

Sales engineer

Technical support engineer

System engineer

Hardware installation engineer

Commissioning engineer

Data configuration engineer

Maintenance engineer

Symbol Conventions

The symbols that may be found in this document are defined as follows.

Symbol Conventions

Symbol Description

Indicates an imminently hazardous situation which, if

not avoided, will result in death or serious injury.

Indicates a potentially hazardous situation which, if not

avoided, could result in death or serious injury.

Page 4: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual About This Document

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

iii

Symbol Description

Indicates a potentially hazardous situation which, if not

avoided, may result in minor or moderate injury.

Indicates a potentially hazardous situation which, if not

avoided, could result in equipment damage, data loss,

performance deterioration, or unanticipated results.

NOTICE is used to address practices not related to

personal injury.

Calls attention to important information, best practices

and tips.

NOTE is used to address information not related to

personal injury, equipment damage, and environment

deterioration.

Change History

Changes between document issues are cumulative. The latest document issue contains all the

changes made in earlier issues.

Issue 05 (2015-12-25)

Updated the issue of this document, as the pictures in chinese document changed.

Issue 04 (2015-06-25)

Support UPS2000-A-(6 kVA–10 kVA) and UPS5000-A-(30 kVA–120 kVA).

Issue 03 (2014-05-15)

Updated the pictures in this document.

Issue 02 (2013-08-24)

Updated the pictures in this document.

Issue 01 (2013-05-15)

This is the first release.

Page 5: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual Contents

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

iv

Contents

About This Document .................................................................................................................... ii

1 Safety Precautions ......................................................................................................................... 1

2 Overview ......................................................................................................................................... 2

2.1 Introduction .................................................................................................................................................................. 2

2.2 Functions ...................................................................................................................................................................... 2

2.3 Typical Application Scenario ........................................................................................................................................ 3

3 Function Description .................................................................................................................... 5

3.1 Pins on the DB25 Port .................................................................................................................................................. 5

3.2 DB25 Cable .................................................................................................................................................................. 7

3.3 Electrical Specifications of the Output Dry Contact Relay .......................................................................................... 7

4 Installation...................................................................................................................................... 9

4.1 Unpacking and Checking .............................................................................................................................................. 9

4.2 Tool Preparation ............................................................................................................................................................ 9

4.3 Installation Procedure ................................................................................................................................................. 10

4.4 Setting the Dry Contact Parameters ............................................................................................................................ 11

A Acronyms and Abbreviations .................................................................................................. 14

Page 6: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual 1 Safety Precautions

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

1

1 Safety Precautions

1. Only professional technical personnel designated by Huawei are allowed to install and

operate the RMS-RELAY01A card.

2. Carefully read this document before operating the RMS-RELAY01A card. Keep this

document for future use.

3. Before handling the RMS-RELAY01A card, get tools insulated, and take off metal

articles such as watches and rings.

4. To avoid damage, move the RMS-RELAY01A card gently.

5. Connect the DB25 port to safety low-voltage circuits. Otherwise, the RMS-RELAY01A

card may be damaged, or even security accidents may occur.

6. External devices must meet the electrical specifications of the RMS-RELAY01A card.

Page 7: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual 2 Overview

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

2

2 Overview

2.1 Introduction

The RMS-RELAY01A card is installed in an optional card slot on the UPS and supports hot

swap. The dry contact card provides six alarm dry contact outputs (normal mode, battery

mode, bypass mode, battery undervoltage, bypass backfeed, and UPS faults) and two dry

contract control inputs (one is for shutdown signals, and the other is reserved).

For UPS5000-A-(30 kVA–120 kVA), the output dry contacts are available, and input dry contacts are

unavailable.

Table 2-1 lists basic specifications of the RMS-RELAY01A card.

Table 2-1 Basic specifications

Model Appearance Specifications

RMS-RELAY01A

Applicable UPS: UPS2000-G-(6

kVA–20 kVA), UPS2000-A-(6

kVA–10 kVA), and UPS5000-A-(30

kVA–120 kVA).

Ambient temperature and humidity:

–40°C to +65°C; 5%–95% RH.

2.2 Functions

The RMS-RELAY01A card has six alarm outputs, as described in Table 2-2. Set the dry

contacts on the liquid crystal display (LCD). Each dry contact can be associated with a type of

alarms.

Page 8: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual 2 Overview

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

3

Table 2-2 RMS-RELAY01A card functions

Dry Contact Type Function Dry Contact No. Dry Contact Definition

Output Normal mode 1 Normal mode, or

normal mode in

ECO mode

Battery mode 2 Battery mode, or

battery mode in

ECO mode

Bypass mode 3 Bypass mode or

ECO mode

Battery undervoltage 4 The monitoring

system determines

that the battery

voltage is low

according to the

battery management

solution.

Bypass backfeed 5 The UPS reports

bypass feedback

alarms.

UPS faults 6 Critical alarms are

generated.

Input Shutdown 1 An inverter

shutdown instruction

is delivered.

Reserved 2 Reserved

For UPS2000-G-(6 kVA–20 kVA), the output dry contact No. of the RMS-RELAY01A card is

configurable on the LCD. For details, see 4.4 Setting the Dry Contact Parameters.

2.3 Typical Application Scenario

Figure 2-1 shows a typical application scenario in which the RMS-RELAY01A card reports

five working modes of the UPS.

Page 9: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual 2 Overview

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

4

Figure 2-1 Typical application scenario

Page 10: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual 3 Function Description

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

5

3 Function Description

3.1 Pins on the DB25 Port

Figure 3-1 Pins on the DB25 port

Table 3-1 Description of the pins on the DB25 port

Pin No. Signal Input/Output Description

1 AGND Output External analog

ground

2 INPUT2 Input External Boolean

value 2 input

3 None None Unused

4 None None Unused

Page 11: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual 3 Function Description

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

6

Pin No. Signal Input/Output Description

5 OUTPUT6– Output Dry contact 6

common terminal

6 OUTPUT5_B Output Dry contact 5

normally closed

(NC) contact

7 OUTPUT5_A Output Dry contact 5

normally open (NO)

contact

8 OUTPUT4– Output Dry contact 4

common terminal

9 OUTPUT3_B Output Dry contact 3 NC

contact

10 OUTPUT3_A Output Dry contact 3 NO

contact

11 OUTPUT2– Output Dry contact 2

common terminal

12 OUTPUT1_B Output Dry contact 1 NC

contact

13 OUTPUT1_A Output External dry contact

1 NO contact

14 INPUT1 Input External Boolean

value 1 input

15 None None Unused

16 None None Unused

17 OUTPUT6_B Output Dry contact 6 NC

contact

18 OUTPUT6_A Output Dry contact 6 NO

contact

19 OUTPUT5– Output Dry contact 5

common terminal

20 OUTPUT4_B Output Dry contact 4 NC

contact

21 OUTPUT4_A Output Dry contact 4 NO

contact

22 OUTPUT3– Output Dry contact 3

common terminal

23 OUTPUT2_B Output Dry contact 2 NC

contact

24 OUTPUT2_A Output Dry contact 2 NO

Page 12: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual 3 Function Description

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

7

Pin No. Signal Input/Output Description

contact

25 OUTPUT1– Output Dry contact 1

common terminal

3.2 DB25 Cable

Figure 3-2 DB25 cable

The DB25 cable, which is delivered along with the RMS-RELAY01A card, is 1.5 meters long.

To increase the length, add a magnetic ring to the connector of the DB25 cable. Table 3-2 lists

the specifications of magnetic rings from three vendors.

Table 3-2 Specifications of magnetic rings from three vendors

Vendor Magnetic Ring

DMEGC R10K

TDK HS10

TDG TS10

The initial magnetic conductivity of manganese and zinc magnetic rings is greater than 10,000. The

recommended internal diameter of magnetic rings is greater than 10 mm (easy for wire coiling). The

number of coiling circles is 5 or more.

3.3 Electrical Specifications of the Output Dry Contact Relay

Table 3-3 lists electrical specifications of the output dry contact relay.

Page 13: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual 3 Function Description

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

8

Table 3-3 Electrical specifications of the output dry contact relay

Item Specifications

Maximum contact power 30 W

Rated contact voltage 30 V DC

Rated contact current 1 A

Input dry contact voltage 12–24 V DC

Page 14: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual 4 Installation

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

9

4 Installation

4.1 Unpacking and Checking

After you receive the RMS-RELAY01A card, unpack the case and check as follows:

Visually inspect the appearance for shipping damage. If it is damaged, notify the carrier

immediately.

Check that the fittings comply with the order. If some fittings are missing or do not

comply with the packing list, record the information and contact your local Huawei

office immediately.

4.2 Tool Preparation

Table 4-1 Tools

Tools

Insulated Phillips

screwdriver

Multimeter Labels Polyvinyl chloride

(PVC) insulation

tape

Protective gloves ESD gloves Cable ties N/A

N/A

Page 15: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual 4 Installation

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

10

4.3 Installation Procedure

The methods for installing RMS-RELAY01A cards are the same on different UPSs. The

RMS-RELAY01A card is installed in the optional card slot INTELLISLOT at the rear panel

of the UPS2000 and installed in the slot for dry contact card at the rear panel of the

UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions.

Procedure

Step 1 Check that the following items are available. One RMS-RELAY01A card, one DB25 cable,

and one RMS-RELAY01A User Manual.

Step 2 Remove the optional card slot cover from the UPS, as shown in Figure 4-1. Keep the screws

for use in Step 3, and the cover for future use.

Figure 4-1 Removing the optional card slot cover

Step 3 Insert the RMS-RELAY01A into the optional card slot along the guide rails, as shown in

Figure 4-2, and then tighten the screws.

The card uses M3 screws. The recommended torque is 0.5 N·m.

Page 16: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual 4 Installation

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

11

Figure 4-2 Inserting the RMS-RELAY01A into the optional card slot

Step 4 Connect one end of the cable to the DB25 port on the RMS-RELAY01A card and the other

end to the customer equipment, as shown in Figure 4-3, and then tighten the screws.

Figure 4-3 Connecting the RMS-RELAY01A card to customer equipment

----End

4.4 Setting the Dry Contact Parameters

UPS2000-A-(6 kVA–10 kVA) and UPS5000-A-(30 kVA–120 kVA) can not set monitoring

parameter on the LCD.

Page 17: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual 4 Installation

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

12

For UPS2000-G-(6 kVA–20 kVA), after you install the RMS-RELAY01A card, set the dry

contact on the LCD.

Procedure

Step 1 Press on the LCD. On the main menu, choose Settings.

Step 2 Enter a password. (The preset password is 000001.)

Step 3 Select Communication Card.

Step 4 Press , the Communication Card screen is displayed. Set the dry contact parameters

for RMS-RELAY01A card.

Multiple statuses can be associated with one dry contact, but one status cannot be associated with

multiple dry contacts.

Normal mode parameter

Set the output dry contact associated with normal mode. When the UPS is in normal or

ECO mode, this dry contact is enabled. The value ranges from Dry contact1 to Dry

contact6. The default value is Dry contact1.

Battery mode parameter

Page 18: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual 4 Installation

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

13

Set the output dry contact associated with battery mode. When the UPS is in battery or

battery ECO mode, this dry contact is enabled. The value ranges from Dry contact1 to

Dry contact6. The default value is Dry contact2.

Bypass mode parameter

Set the output dry contact associated with bypass mode. When the UPS is in bypass or

ECO mode, this dry contact is enabled. The value ranges from Dry contact1 to Dry

contact6. The default value is Dry contact3.

Batt. undervolt parameter

Set the output dry contact associated with low battery voltage. When the system battery

voltage is low, this dry contact is enabled. The value ranges from Dry contact1 to Dry

contact6. The default value is Dry contact4.

BPS backfeed parameter

Set the output dry contact associated with bypass backfeed. When a bypass backfeed

alarm is generated, this dry contact is enabled. The value ranges from Dry contact1 to

Dry contact6. The default value is Dry contact5.

Faulty UPS parameter

Set the output dry contact associated with UPS faults. When a critical alarm is generated,

this dry contact is enabled. The value ranges from Dry contact1 to Dry contact6. The

default value is Dry contact6.

----End

Page 19: User Manual - Huawei UPS · 2017-08-31 · UPS5000-A. The installation position of RMS-RELAY01A cards based on actual conditions. Procedure Step 1 Check that the following items are

RMS-RELAY01A

User Manual A Acronyms and Abbreviations

Issue 05 (2015-12-25) Huawei Proprietary and Confidential

Copyright © Huawei Technologies Co., Ltd.

14

A Acronyms and Abbreviations

E

ECO economy control operation

ESD electrostatic discharge

L

LCD liquid crystal display

N

NC normally closed

NO normally open

P

PVC polyvinyl chloride

U

UPS uninterruptible power system