![Page 1: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7](https://reader037.fdocuments.in/reader037/viewer/2022090611/607ad6e03060a814aa2f18d1/html5/thumbnails/1.jpg)
InstantWaterHeater
CIS-E363DCRCIS-E369DCR
User Manual
![Page 2: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7](https://reader037.fdocuments.in/reader037/viewer/2022090611/607ad6e03060a814aa2f18d1/html5/thumbnails/2.jpg)
PARTS IDENTIFICATION
When the Shower is used by someone such as child, elderly person, sick person 1.5 and physically handicapped person, the concern person is kindly requested to pay attention and check the shower temperature by using hand from time to time.
In me of lightning/thunder, switch "off'' the electric supply to the shower unit in advance to protect the shower unit against possible damage.
1.6
Note: When removing the unit from package, small amount of water may found inside. This is normal as the unit is tested during manufacturing process.
Improper grounding could cause electrical shock.
User is advised to test and adjust the water temperature before bathing.
1.7 e used.
IMPORTANT SAFETY INFORMATION
For Pump Model, it is highly recommended to connect the Water Inlet Connection to tank storage supply, otherwise it may cause damage to the Pump Motor.
maximum 2
working pressure of 6 bars.
2
GG
Fig 1.
32 32
19
20
21
22
23
24
25
26
27
28
29
19
20
21
22
23
24
25
27
28
29
30
31
8
9
10
8
9
10
2. Face Sticker
1. Front Cover
3. Indicator Lamp
5. Temperature Control Knob
4. Pump Knob
6. Test / Reset Button
7. Pump Booster Button
9. Flow Regulator Valve
10. Filter Valve
11. Rain Shower Head
12. Sliding Rail
13. Wall Bracket
14. Hand Shower
15. Shower Holder
16. PVC Hose 1.5m
17. Selector Valve
20. PCB Board
21. Thermostat
23. Terminal Block
22. Heater Tank
24. Main PCB Board
25. Water Outlet Connection
26. AC Pump
27. TRIAC
28. Water INLET Connection
29. Reed Switch Assy
30. SMPS PCB Board
31. D.C Silent Pump
18. PVC Hose 1.0m
32. Mesh Filter
19. Heater Base
8. Stop Valve
5
11
12
13
14
15
16
17
18
8
9
10
1
2
3
6
7
4
32
![Page 3: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7](https://reader037.fdocuments.in/reader037/viewer/2022090611/607ad6e03060a814aa2f18d1/html5/thumbnails/3.jpg)
Minimum Conductor Size (csa)
TABLE 1-ELECTRICAL LOADING TABLE
INSTALL THE HEATER UNIT
HEATER UNIT INSTALLATION DIAGRAM
RAIL BRACKET COVER & CAP DISMANTLE STEPS
RAIL BRACKET OPEN THE RAIL BRACKET COVERBY TURNING ANTI CLOCKWISE & USING SCREW DRIVER TO OPEN THE CAP
RAIL BRACKET COVER COME-OUT
1 2 3
RAIN SHOWER SET INSTALLATION PROCEDURES
G
65mm
255mm
![Page 4: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7](https://reader037.fdocuments.in/reader037/viewer/2022090611/607ad6e03060a814aa2f18d1/html5/thumbnails/4.jpg)
shower holder
top rail bracket
slider rail
selector valve
1. 2.
STEP 1Insert the Top Rail Bracket, Adjustable Shower Holder, & Bottom Rail Bracket to the Slider Rail.
STEP 2Connect the Selector Valve to the bottom of Slider Rail.
bottom rail bracket
38mm
38mm
1300
mm
650m
m
wall plug hole screw
mounting terminal
3. 4.
Select a suitable position for the Rain Shower Set then mark 4 screws point(2 on top and 2 on bottom). The gap of2 screw hole was 38mm. It is recommended that the Top Rail Bracket position at height of 1950mm to the floorand Bottom Rail Bracket 1300mm to the floor.
wall plug
STEP 4Use 6mm diameter drill and make the wall plug holes in
depth of 34mm. Insert the wall plugs and mounting terminal firmly in position with the screw provided.
STEP 5Mount the Slider Rail (connected with Rail Bracket, Adjustable Shower Holder and Selector Valve)
to the mounting terminal by turns the terminal cover.
5.
STEP 3
1200
mm
650m
m10
0mm
PVC hose
rain showerhead
shower head
7. 8.
STEP 7Connect the Rain Shower Head to the top of Slider Rail, 1.5Meter PVC Hose to Hand Shower Head and 1Meter PVC Hose to the Heater. Connected be sure to put in the Rubber Washer.
STEP 8Recommended Height for Rain Shower Set.
rubberwasher
a
b
c
d
rail bracket cap
hexagon tool
plastic nut
6.
STEP 6Remove the cover and cap from the Rail Bracket (Fig. 3A) and screw the rail bracket by turning the cover clockwise. Using hexagon tool to tighten the plastic nut to the desire position and then replace the cover.
rail bracketcover
rain showerhead
continue from RAIN SHOWER SET INSTALLATION PROCEDURES continue from RAIN SHOWER SET INSTALLATION PROCEDURES
![Page 5: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7](https://reader037.fdocuments.in/reader037/viewer/2022090611/607ad6e03060a814aa2f18d1/html5/thumbnails/5.jpg)
2.5of
.
.
4.
5. Do not use white tape during installation.
6.
7.8.
Improper grounding could cause electrical shock.
continue from ELECTRICAL INSTALLATION -IMPORTANT
ELECTRICAL INSTALLATION -IMPORTANT
Make sure to put the Mesh Filter between Stop Valve and incomingwater piping.
3. If in any case, the Stop Valve is not use or omitted, make sure to put the Mesh Filter between the heater unit inlet pipe and incoming water pipe.
PLUMBING PROCEDURE - IMPORTANT
correctover tighten and damage
7 8
(*) To ensure the power cord NOTtouch copper flange.
G
Side Entry A
(*)
B
![Page 6: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7](https://reader037.fdocuments.in/reader037/viewer/2022090611/607ad6e03060a814aa2f18d1/html5/thumbnails/6.jpg)
continue from ELECTRICAL INSTALLATION - IMPORTANT
TEST RUN
8
9
10
11 ON/OFF
6. The earth indicator will turn "ON" if wiring is done correctly. When earth indicator is "OFF", please check the following:-
- Improper earthing - Live (L) and Neutral (N) reversed.
continue from TEST RUN
9 10
Release Knob
G
Positionthis Way
Positionthis Way
7 turn
knob
- Press the ‘’RESET’’ button, the 3 LED indicator lights shall run ON/OFF 3 times in sequences to indicate self check as in No.2 above and the Heater Unit should resume normal function, the Green LED Indicator should light on.
Switch on the electrical supply. The 3 LED indicator light shall run ON/OFF 3 times in sequences to indicate the set are self checking.
VARIABLE SWITCH
Positionthis Way
Positionthis Way
![Page 7: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7](https://reader037.fdocuments.in/reader037/viewer/2022090611/607ad6e03060a814aa2f18d1/html5/thumbnails/7.jpg)
11 12
test at least once a month).
8
HAND SHOWER ACTION
MAINTENANCE
continue from MAINTENANCE
10
(Fig. 9 & Fig. 10 )
Fig. 9.
Fig. 9.
0
9
CLOSEOPEN
INTERNAL STRAINER
OPEN CLOSE
FLOW REGULATOR
MESH FILTER
BUILT-IN FILTER
Clean the Handshower Head holes by using the soft brush from time to time.(Recommended once a week)Note: Take care not to damage the holes of the Handshower Head during cleaning.
8
WIRING DIAGRAM
LIVE
NEUTRAL
Main Supply220 -240 V ~ a.c
TRIAC
Lout
Nout (Nin )
(Lin )
Electronic ELCB,15mA Sensitivity
Heater Control
ResetTestPump Booster
T2
G
AutoThermostat
ManualThermostat
Pump On/Off
Power On/OffTemperature Control
On/Off Switch
Led Board
SMPS PCBASSY
Silent Pump,
WIRING DIAGRAM - DPDT ( SILENT PUMP MODEL)
![Page 8: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7](https://reader037.fdocuments.in/reader037/viewer/2022090611/607ad6e03060a814aa2f18d1/html5/thumbnails/8.jpg)
continue from WIRING DIAGRAM
13 14
LIVE
NEUTRAL
Main Supply220 -240 V ~ a.c
TRIAC
Lout
Nout (Nin )
(Lin )
Electronic ELCB,15mA Sensitivity
WIRING DIAGRAM - DPDT MODEL
(*) For PUMP Model
Note : (*) For Pump Model
AC PUMP,120W, 240V d.c
Heater Control
ResetTestPump Booster
T2
G
(*)
AutoThermostat
ManualThermostat
Pump On/Off
Power On/OffTemperature Control
On/Off Switch
Led Board
LIVE
NEUTRAL
Main Supply220 -240 V ~ a.c
TRIAC
(Nin )
(Lin )
Electronic ELCB,15mA Sensitivity
Heater Control
ResetTestPump Booster
T2
G
Pump On/Off
Power On/OffTemperature Control
On/Off Switch
Led Board
SMPS PCBASSY
Silent Pump,
AutoThermostat
WIRING DIAGRAM - SINGLE POLE MODEL ( SILENT PUMP MODEL) ELECTRICAL SPECIFICATION
EP : 6.0 Kg - ELCB, A.C PUMPESP : 5.3 Kg - ELCB, SILENT PUMP
250 X 400 X 105 mm
3.3kW 230Va.c.
2
0.1 Bar (10kPa)Min. INLET WATER PRESSURE
Max. INLET WATER PRESSURE 6.0 Bar (0.6MPa)
continue from WIRING DIAGRAM
WIRING DIAGRAM - SINGLE POLE MODEL
LIVE
NEUTRAL
Main Supply220 -240 V ~ a.c
TRIAC
(Nin )
(Lin )
Electronic ELCB,15mA Sensitivity
(*) For PUMP Model
Note : (*) For Pump Model
AC PUMP,120W, 240V d.c
Heater Control
ResetTestPump Booster
T2
G
(*)
Pump On/Off
Power On/OffTemperature Control
On/Off Switch
Led Board
AutoThermostat