Page 1: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7

InstantWaterHeater

CIS-E363DCRCIS-E369DCR

User Manual

Page 2: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7

PARTS IDENTIFICATION

When the Shower is used by someone such as child, elderly person, sick person 1.5 and physically handicapped person, the concern person is kindly requested to pay attention and check the shower temperature by using hand from time to time.

In me of lightning/thunder, switch "off'' the electric supply to the shower unit in advance to protect the shower unit against possible damage.

1.6

Note: When removing the unit from package, small amount of water may found inside. This is normal as the unit is tested during manufacturing process.

Improper grounding could cause electrical shock.

User is advised to test and adjust the water temperature before bathing.

1.7 e used.

IMPORTANT SAFETY INFORMATION

For Pump Model, it is highly recommended to connect the Water Inlet Connection to tank storage supply, otherwise it may cause damage to the Pump Motor.

maximum 2

working pressure of 6 bars.

2

GG

Fig 1.

32 32

19

20

21

22

23

24

25

26

27

28

29

19

20

21

22

23

24

25

27

28

29

30

31

8

9

10

8

9

10

2. Face Sticker

1. Front Cover

3. Indicator Lamp

5. Temperature Control Knob

4. Pump Knob

6. Test / Reset Button

7. Pump Booster Button

9. Flow Regulator Valve

10. Filter Valve

11. Rain Shower Head

12. Sliding Rail

13. Wall Bracket

14. Hand Shower

15. Shower Holder

16. PVC Hose 1.5m

17. Selector Valve

20. PCB Board

21. Thermostat

23. Terminal Block

22. Heater Tank

24. Main PCB Board

25. Water Outlet Connection

26. AC Pump

27. TRIAC

28. Water INLET Connection

29. Reed Switch Assy

30. SMPS PCB Board

31. D.C Silent Pump

18. PVC Hose 1.0m

32. Mesh Filter

19. Heater Base

8. Stop Valve

5

11

12

13

14

15

16

17

18

8

9

10

1

2

3

6

7

4

32

Page 3: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7

Minimum Conductor Size (csa)

TABLE 1-ELECTRICAL LOADING TABLE

INSTALL THE HEATER UNIT

HEATER UNIT INSTALLATION DIAGRAM

RAIL BRACKET COVER & CAP DISMANTLE STEPS

RAIL BRACKET OPEN THE RAIL BRACKET COVERBY TURNING ANTI CLOCKWISE & USING SCREW DRIVER TO OPEN THE CAP

RAIL BRACKET COVER COME-OUT

1 2 3

RAIN SHOWER SET INSTALLATION PROCEDURES

G

65mm

255mm

Page 4: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7

shower holder

top rail bracket

slider rail

selector valve

1. 2.

STEP 1Insert the Top Rail Bracket, Adjustable Shower Holder, & Bottom Rail Bracket to the Slider Rail.

STEP 2Connect the Selector Valve to the bottom of Slider Rail.

bottom rail bracket

38mm

38mm

1300

mm

650m

m

wall plug hole screw

mounting terminal

3. 4.

Select a suitable position for the Rain Shower Set then mark 4 screws point(2 on top and 2 on bottom). The gap of2 screw hole was 38mm. It is recommended that the Top Rail Bracket position at height of 1950mm to the floorand Bottom Rail Bracket 1300mm to the floor.

wall plug

STEP 4Use 6mm diameter drill and make the wall plug holes in

depth of 34mm. Insert the wall plugs and mounting terminal firmly in position with the screw provided.

STEP 5Mount the Slider Rail (connected with Rail Bracket, Adjustable Shower Holder and Selector Valve)

to the mounting terminal by turns the terminal cover.

5.

STEP 3

1200

mm

650m

m10

0mm

PVC hose

rain showerhead

shower head

7. 8.

STEP 7Connect the Rain Shower Head to the top of Slider Rail, 1.5Meter PVC Hose to Hand Shower Head and 1Meter PVC Hose to the Heater. Connected be sure to put in the Rubber Washer.

STEP 8Recommended Height for Rain Shower Set.

rubberwasher

a

b

c

d

rail bracket cap

hexagon tool

plastic nut

6.

STEP 6Remove the cover and cap from the Rail Bracket (Fig. 3A) and screw the rail bracket by turning the cover clockwise. Using hexagon tool to tighten the plastic nut to the desire position and then replace the cover.

rail bracketcover

rain showerhead

continue from RAIN SHOWER SET INSTALLATION PROCEDURES continue from RAIN SHOWER SET INSTALLATION PROCEDURES

Page 5: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7

2.5of

.

.

4.

5. Do not use white tape during installation.

6.

7.8.

Improper grounding could cause electrical shock.

continue from ELECTRICAL INSTALLATION -IMPORTANT

ELECTRICAL INSTALLATION -IMPORTANT

Make sure to put the Mesh Filter between Stop Valve and incomingwater piping.

3. If in any case, the Stop Valve is not use or omitted, make sure to put the Mesh Filter between the heater unit inlet pipe and incoming water pipe.

PLUMBING PROCEDURE - IMPORTANT

correctover tighten and damage

7 8

(*) To ensure the power cord NOTtouch copper flange.

G

Side Entry A

(*)

B

Page 6: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7

continue from ELECTRICAL INSTALLATION - IMPORTANT

TEST RUN

8

9

10

11 ON/OFF

6. The earth indicator will turn "ON" if wiring is done correctly. When earth indicator is "OFF", please check the following:-

- Improper earthing - Live (L) and Neutral (N) reversed.

continue from TEST RUN

9 10

Release Knob

G

Positionthis Way

Positionthis Way

7 turn

knob

- Press the ‘’RESET’’ button, the 3 LED indicator lights shall run ON/OFF 3 times in sequences to indicate self check as in No.2 above and the Heater Unit should resume normal function, the Green LED Indicator should light on.

Switch on the electrical supply. The 3 LED indicator light shall run ON/OFF 3 times in sequences to indicate the set are self checking.

VARIABLE SWITCH

Positionthis Way

Positionthis Way

Page 7: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7

11 12

test at least once a month).

8

HAND SHOWER ACTION

MAINTENANCE

continue from MAINTENANCE

10

(Fig. 9 & Fig. 10 )

Fig. 9.

Fig. 9.

0

9

CLOSEOPEN

INTERNAL STRAINER

OPEN CLOSE

FLOW REGULATOR

MESH FILTER

BUILT-IN FILTER

Clean the Handshower Head holes by using the soft brush from time to time.(Recommended once a week)Note: Take care not to damage the holes of the Handshower Head during cleaning.

8

WIRING DIAGRAM

LIVE

NEUTRAL

Main Supply220 -240 V ~ a.c

TRIAC

Lout

Nout (Nin )

(Lin )

Electronic ELCB,15mA Sensitivity

Heater Control

ResetTestPump Booster

T2

G

AutoThermostat

ManualThermostat

Pump On/Off

Power On/OffTemperature Control

On/Off Switch

Led Board

SMPS PCBASSY

Silent Pump,

WIRING DIAGRAM - DPDT ( SILENT PUMP MODEL)

Page 8: User Manual - Cornell Appliances | A Simpler Lifesg.cornellappliances.com/wp-content/uploads/2018/10/IM...User is advised to test and adjust the water temperature before bathing. 1.7

continue from WIRING DIAGRAM

13 14

LIVE

NEUTRAL

Main Supply220 -240 V ~ a.c

TRIAC

Lout

Nout (Nin )

(Lin )

Electronic ELCB,15mA Sensitivity

WIRING DIAGRAM - DPDT MODEL

(*) For PUMP Model

Note : (*) For Pump Model

AC PUMP,120W, 240V d.c

Heater Control

ResetTestPump Booster

T2

G

(*)

AutoThermostat

ManualThermostat

Pump On/Off

Power On/OffTemperature Control

On/Off Switch

Led Board

LIVE

NEUTRAL

Main Supply220 -240 V ~ a.c

TRIAC

(Nin )

(Lin )

Electronic ELCB,15mA Sensitivity

Heater Control

ResetTestPump Booster

T2

G

Pump On/Off

Power On/OffTemperature Control

On/Off Switch

Led Board

SMPS PCBASSY

Silent Pump,

AutoThermostat

WIRING DIAGRAM - SINGLE POLE MODEL ( SILENT PUMP MODEL) ELECTRICAL SPECIFICATION

EP : 6.0 Kg - ELCB, A.C PUMPESP : 5.3 Kg - ELCB, SILENT PUMP

250 X 400 X 105 mm

3.3kW 230Va.c.

2

0.1 Bar (10kPa)Min. INLET WATER PRESSURE

Max. INLET WATER PRESSURE 6.0 Bar (0.6MPa)

continue from WIRING DIAGRAM

WIRING DIAGRAM - SINGLE POLE MODEL

LIVE

NEUTRAL

Main Supply220 -240 V ~ a.c

TRIAC

(Nin )

(Lin )

Electronic ELCB,15mA Sensitivity

(*) For PUMP Model

Note : (*) For Pump Model

AC PUMP,120W, 240V d.c

Heater Control

ResetTestPump Booster

T2

G

(*)

Pump On/Off

Power On/OffTemperature Control

On/Off Switch

Led Board

AutoThermostat