Page 1: US HIGHWAY 287, KIT CARSON COLORADO · 2017-08-17 · ASBESTOS INSPECTION REPORT 1.0 Introduction This report provides information regarding an asbestos building materials survey

ASBESTOS INSPECTION REPORT

FOR:

KIT CARSON LLC

AT

701 US HIGHWAY 287, KIT CARSON, COLORADO

AEM PROJECT NUMBER KCL001

PREPARED BY:

ABBEY ENVIRONMENTAL MANAGEMENT, INC.

MAY 16, 2016

Page 2: US HIGHWAY 287, KIT CARSON COLORADO · 2017-08-17 · ASBESTOS INSPECTION REPORT 1.0 Introduction This report provides information regarding an asbestos building materials survey

ASBESTOS INSPECTION REPORT

1.0 Introduction

This report provides information regarding an asbestos building materials survey performed at alocation approximately one-half mile south, and west of County Road 20, of the Town of Kit Carson,Colorado, on May 12, 2016. At the request of Kit Carson LLC, Abbey Environmental Management,Inc. (AEM) performed a visual inspection at a one level single wide mobile home, acquired samplesof suspect asbestos containing building materials (ACBM), assessed the condition of the materials,and determined estimated quantities of those suspect materials.

The purpose of the inspection was to determine locations and quantities of asbestos containingbuilding materials that would have to be abated by removal prior to the intended demolition of themobile home.

The subject property is a single wide mobile home located on a lot near Kit Carson, Colorado. Thesubject property is one level, with a living room, kitchen, two bedrooms and one bathroom. Thehouse is heated with central forced air. The roof is metal.

Samples of suspect materials were sent to Reservoirs Environmental Inc., 5801 Logan Street inDenver, Colorado. Reservoirs is a NVLAP accredited (#101896) laboratory for Polarized LightMicroscopy, the required method of analysis for asbestos.

Details of this survey and analysis follows. Please refer to the Bulk Sample Data Table for asummary of the laboratory analysis results.

2.0 Inspection Rationale

According to Federal EPA NESHAP regulations, and State of Colorado Regulation 8, buildings thathave suspect asbestos containing materials in excess of 160 square feet, 260 linear feet, or 35 cubicfeet (one 55 gallon drum in Colorado) require that a thorough inspection be performed prior torenovation or demolition. For Single Family Residential Dwellings, the trigger level for inspection is50 linear feet, 32 square feet, of the volume equivalent of a 55-gallon drum. AEM performed theinspection accordingly.

Colorado Regulation 8 requires that any friable ACBM with PLM lab result indicating more thanzero, but less than 1% (trace amounts) be Point Counted. No sample indicated trace levels ofasbestos in the survey that was representative of a homogeneous area declared to be ACM, so noPoint Counts were performed for that reason.

2

Page 3: US HIGHWAY 287, KIT CARSON COLORADO · 2017-08-17 · ASBESTOS INSPECTION REPORT 1.0 Introduction This report provides information regarding an asbestos building materials survey

The EPA AHERA regulation contains inspection protocol, and is considered to be the state of the artmethod for performing building inspections for asbestos in building materials. This inspection wasperformed according to those protocols, taking into account the limited scope of the inspection dueto limited destructive sampling.

All samples were acquired in a random manner that also represented the materials sampled. Anarrative description of the sampled materials and their relative locations is contained in the BulkSample Data Table. In addition, a copy of the Reservoirs laboratory report is attached.

All samples, assessment and inspection activities were performed by Kathleen Flanagan andSalvador Canales, EPA accredited and State of Colorado certified Asbestos Building Inspectors.Attached are copies of their certificates.

3.0 Inspection and Survey Findings/Recommendations

At the time of inspection, a total of five suspect materials were discovered and documented. None ofthe suspect materials were assumed to be asbestos containing. Samples were acquired of all of thesuspect materials and submitted for analysis. Following is a list of those suspect materials:

• Multi color sheet vinyl located in the kitchen of the unit. (One Sample)

• Cream colored square sheet vinyl located in the kitchen of the unit. (One Sample)

• Drywall and splatter texture located throughout the unit. (Three Samples)

• Pink insulation located in the kitchen ceiling. (One Sample)

• Multi colored square pattern sheet vinyl located in the bathroom of the unit. (OneSample)

A total of seven samples were acquired in the sampling event. Of these samples, no materialscontained detectable levels of asbestos through standard PLM analysis.

4.0 Conclusions and Recommendations

In the case of the asbestos in the texture on the drywall, sheet vinyl and insulating and roofingmaterials discovered during a thorough inspection in and on the subject mobile home abandoned at alocation approximately one-half mile south, and west of County Road 20, near the Town of KitCarson, Colorado, the mobile home is without CDPHE asbestos abatement regulations, because thesuspect ACM materials samples did not contain asbestos according standard PLM analysis.

3

Page 4: US HIGHWAY 287, KIT CARSON COLORADO · 2017-08-17 · ASBESTOS INSPECTION REPORT 1.0 Introduction This report provides information regarding an asbestos building materials survey

Please remember that only those suspect materials that appeared to have a potential for disturbanceduring the demolition process, were sampled. All workers should be aware of the potential for otherACM’s to be present under or behind those identified. All work should stop when these suspectmaterials are discovered. Suspect materials should be sampled and those samples be analyzed priorto work progressing that would disturb any suspect asbestos containing materials.

5.0 Bulk Sample Data Table

Sample Number Sample Description and Location Lab ResultPLM (P.C.)

701KC-24 Multicolor sheet vinyl with black mastic from the kitchenfloor at the opening in the wall.

ND

701KC-25 Cream colored sheet vinyl with white mastic from thekitchen at the opening.

ND

701KC-26 Drywall with splatter texture from the kitchen centerwhere damaged on the ceiling.

ND

701KC-27 Pink insulation from the kitchen from same locationabove.

ND

701KC-28 Drywall with splatter texture from hallway where hole isbetween bathroom and furnace.

ND

701KC-29 Drywall with splatter texture located on right side ofkitchen pass thru in living room.

ND

701KC-30 Multi colored square pattern sheet vinyl with yellowmastic from bath 1' from entry.'

ND

Note: PLM means Polarized Light Microscopy; P.C. means Point Count; ND means None Detected; TR means

Trace; JC means Joint Compound; Chry means Chrysotile Asbestos

4

Page 5: US HIGHWAY 287, KIT CARSON COLORADO · 2017-08-17 · ASBESTOS INSPECTION REPORT 1.0 Introduction This report provides information regarding an asbestos building materials survey

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2015

T:\QAQC\Lab\Reservoirs Environmental QA Manual.doc

Subcontract Number: NA

Laboratory Report: RES 350168-1

Project # / P.O. #  KCC001

Project Description: None Given

RES 350168-1

Sincerely,

May 16, 2016

Dear Customer,

Reservoirs Environmental, Inc. is an analytical laboratory accredited for the analysis of Industrial Hygiene and

Environmental matrices by the National Voluntary Laboratory Accreditation Program (NVLAP), Lab Code 101896-0

for Transmission Electron Microscopy (TEM) and Polarized Light Microscopy (PLM) analysis and the American

Industrial Hygiene Association (AIHA), Lab ID 101533 - Accreditation Certificate #480 for Phase Contrast

Microscopy (PCM) analysis. This laboratory is currently proficient in both Proficiency Testing and PAT programs

respectively.

Reservoirs Environmental, Inc. has analyzed the following samples for asbestos content as per your request. The

analysis has been completed in general accordance with the appropriate methodology as stated in the attached

analysis table. The results have been submitted to your office.

Abbey Environmental Management

10343 Federal Blvd. Unit J252

Westminster CO 80260

is the job number assigned to this study. This report is considered highly confidential

and the sole property of the customer. Reservoirs Environmental, Inc. will not discuss any part of this study with

personnel other than those of the client. The results described in this report only apply to the samples analyzed.

This report must not be used to claim endorsement of products or analytical results by NVLAP or any agency of the

U.S. Government. This report shall not be reproduced except in full, without written approval from Reservoirs

Environmental, Inc. Samples will be disposed of after sixty days unless longer storage is requested. If you have any

questions about this report, please feel free to call 303-964-1986.

Jeanne Spencer

President

P: 303-964-1986

F: 303-477-4275

5801 Logan Street, Suite 100 Denver, CO 80216

Page 1 of 1

1-866-RESI-ENV

www.reilab.com

Page 6: US HIGHWAY 287, KIT CARSON COLORADO · 2017-08-17 · ASBESTOS INSPECTION REPORT 1.0 Introduction This report provides information regarding an asbestos building materials survey

RES Job Number:

Client:

Client Project Number / P.O.:

Client Project Description:

Date Samples Received:

Turnaround:

Date Samples Analyzed:

RES 350168-1

Abbey Environmental Management

KCC001

None Given

May 12, 2016

24 Hour

May 16, 2016

TABLE: PLM BULK ANALYSIS, PERCENTAGE COMPOSITION BY VOLUME

Reservoirs Environmental, Inc.

Reservoirs Environmental QA Manual

Effective January 1, 2015

Q:\QAQC\LAB\Reservoirs Environmental QA Manual.doc

RESERVOIRS ENVIRONMENTAL INC.

NVLAP Lab Code 101896-0

Client

Sample

Number

Lab

ID Number

LAYER

Mineral

Method: EPA 600/R-93/116 - Short Report, Bulk

PhysicalDescription

SubPart

(%)

Visual

Estimate

(%)

ND=None DetectedTR=Trace, <1% Visual EstimateTrem/Act=Tremolite/Actinolite

NonAsbestosFibrous

Components(%)

Non-Fibrous

Components

(%)

Asbestos Content

7525701KC-24 EM 1629183 Tan/multi-colored sheet vinyl w/ gray/blue fibrous backing material

A 100 ND

7525701KC-25 EM 1629184 Beige sheet vinyl w/ white fibrous backing material & off white adhesive

A 100 ND

1000701KC-26 EM 1629185 White/off white paint w/ white granular textureA 12 ND

8515Pink/tan drywallB 88 ND

595701KC-27 EM 1629186 Pink/yellow insulationA 100 ND

1000701KC-28 EM 1629187 White granular texture w/ white paintA 10 ND

8515Pink/tan drywallB 90 ND

1000701KC-29 EM 1629188 Beige/off white paint w/ white granular textureA 12 ND

8515White/tan drywallB 88 ND

7525701KC-30 (labeled as 701KC-29) EM 1629189 Off white sheet vinyl w/ off white fibrous backing material & yellow adhesive

A 100 ND

TEM Analysis recommended for organically bound material (i.e. floor tile) if PLM results are <1%.

Analyst / Data QAAnalystAnalystAnalystAnalyst

P: 303-964-1986

F: 303-477-4275

1-866-RESI-ENV

www.reilab.com

5801 Logan Street, Suite 100, Denver, CO 80216

Page 1 of 1

Page 7: US HIGHWAY 287, KIT CARSON COLORADO · 2017-08-17 · ASBESTOS INSPECTION REPORT 1.0 Introduction This report provides information regarding an asbestos building materials survey
Page 8: US HIGHWAY 287, KIT CARSON COLORADO · 2017-08-17 · ASBESTOS INSPECTION REPORT 1.0 Introduction This report provides information regarding an asbestos building materials survey

_ . . . . .

Colorado Department of Public Health

and Environment

ASBESTOS CERTIFICATION*

T h i s c e r t i f i e s t h a t

Kathleen Flanagan Certification No.: 17251

h a s m e t t h e r e q u i r e m e n t s o f 2 5 - 7 - 5 0 7 , C . R . S . a n d A i r Q u a l i t y C o n t r o l C o m m i s s i o n R e g u l a t i o n N o . 8 , P a r t B , a n d i s h e r e b y c e r t i f i e d b y t h e

s t a t e o f C o l o r a d o i n t h e f o l l o w i n g d i s c i p l i n e :

Building Inspector*

p

Issued:

Expires:

June 12, 2015

June 12, 2016

* ry»/s certificate is vaiid oniy with the possession of a c u r r e n t Division-approved t r a i n i n g course certification i n the discipline specified above. '.HI.

A u t h o r i z e d A P C D R e p r e s e n ^ t i v e

S E A L

Page 9: US HIGHWAY 287, KIT CARSON COLORADO · 2017-08-17 · ASBESTOS INSPECTION REPORT 1.0 Introduction This report provides information regarding an asbestos building materials survey

m ^ ^ ^ ^ ^ ^ ^

3>i

Colorado Department of Public Health and Environment

ASBESTOS CERTIFICATION*

T h i s c e r t i f i e s t h a t

Salvador Canales Certification No.: 22492

h a s m e t t h e r e q u i r e m e n t s o f 2 5 - 7 - 5 0 7 , C . R . S . a n d A i r Q u a l i t y C o n t r o l C o m m i s s i o n R e g u l a t i o n N o . 8 , P a r t B , a n d i s h e r e b y c e r t i f i e d b y t h e

s t a t e o f C o l o r a d o i n t h e f o l l o w i n g d i s c i p l i n e :

Building Inspector*

Issued: October 15, 2015

Expires: October 15, 2016

* T h i s certificate is valid only with the possession o f a c u r r e n t Division-approved t r a i n i n g course certification i n the discipiine specified above.

m

Ajithorized APCD Representative

SEAL