Urinary Incontinence

20
Urinary Incontinence Biopolymer GmbH & Co.KG - Germany

description

Biopolymer GmbH & Co.KG - Germany. Urinary Incontinence. Biopolymer GmbH & Co.KG - Germany. Treatment Options:. Physical Therapy: a conservative early stage treatment for UI , including pelvic floor muscles training known as Kegel exercise. Medications: by means of pharmaceutical drugs - PowerPoint PPT Presentation

Transcript of Urinary Incontinence

Page 1: Urinary Incontinence

Urinary IncontinenceBiopolymer GmbH & Co.KG - Germany

Page 2: Urinary Incontinence

Treatment Options:1. Physical Therapy:

a conservative early stage treatment for UI , including pelvic floor muscles training known as Kegel exercise.

2. Medications: by means of pharmaceutical drugs

( fesoterodine, tolterodine, oxybutynin, ..etc ).

3. devices: absorbent pads,urinary catheters.

4. Surgical procedures.

5. Bulking agents – Urethral Injections of impant material.

Biopolymer GmbH & Co.KG - Germany

Page 3: Urinary Incontinence

Treatment Options:Surgical procedures:

1. TVT: Tension-Free transvaginal sling.

2. TOT: Transoburator tape sling.

3. Mini Sling ( mini-arc ) ( TVT-secure)

4. Marshal-Marchetti-Krantz: retropubic suspension / bladder neck suspension

5. Artificial unrinary sphincter.

Biopolymer GmbH & Co.KG - Germany

Page 4: Urinary Incontinence

Treatment Options:Urethral Injections – Bulking Agents:

Is a minimal surgical procedure providing

An alternative in treatment options:

The Ideal Bulking agent of choice must include following charecteristics:

1. Biocompatible.

2. Biodegradable.

3. Bio-stable: no deformation after injection.

4. No Migration after implantion.

5. No erosion after implantion.

6. Easy to applicate – without the need to apply pressure when injecting.

Biopolymer GmbH & Co.KG - Germany

Page 5: Urinary Incontinence

Treatment Options:Available Bulking Agents for UI:

1. Polytetrafluoroethylene(teflon) : no longer used.

2. Autologous fat: no longer used.

3. Macroplastique: silicone elastomer polydimethylsiloxane suspended in polyvinylpyrrolidone PVP Carrier.It is a permanent implant applied by transurethral technique – injection beneath the lining of urethra – can cause urethral erosion with irreversable damage in case of failure of procedure – procedure must be done in operation room.

4. Contigen: Glutar aldehyde cross linked bovine collagen: it begins degradation within 12 weeks with complete degaradation within 19month , and patient must undergo a skin test to exclude hypersinsensitivity due to collagen ( animal origin ) before one month of the procedure.

Biopolymer GmbH & Co.KG - Germany

Page 6: Urinary Incontinence

Treatment Options:Available Bulking Agents:

5. Bulkamid: 25% polyacrylamide hydrogel , 97% apyrogenic water, is a permanent implant (nonbiodegradable)

6. Durasphere: carbon coated zirconium oxide particles suspended in water soluble B-glucan vehicle , is a permanent implant, upon clinical trials Durasphere migrates from impantation site which might cause permanent urinary retention.

7. Coaptite: calcium hydroxylapatite particles suspended in sodium carboxymethylcellulose , water, glycerin gel form carrier, upon clinical trials the particles becomes deformed, irregular along with migration from injection site resulting in periurethral fibrosis, obstruction, prolapse.

Biopolymer GmbH & Co.KG - Germany

Page 7: Urinary Incontinence

Treatment Options:Available Bulking Agents:

8. Tegress: formrly known as URYX : ethylenevinyl alcohol copolymer suspended in dimethyl sulfoxide: have discontinued sales due to reports of 37% erosion rates.

9. Zuidex: Dextranomere microspheres in cross linked hyaluronic acid carrier.

10.Urodex : DEAE-Sephadex- Dextran positively Charged Dextranomere.

Urodex composition:

Sodium Hyaluronate cross linked: 17mg

DEAE Sephadex Dextran + chagre: 50mg

Sodium Chloride: 6.9mg

Water for injection: 1.0ml

Biopolymer GmbH & Co.KG - Germany

Page 8: Urinary Incontinence

Urodex designed Technolgy:Why to use Urodex ? What is the added

Benefits of Urodex ?

In order to realize the added benefits of Urodex, a summary explaining the designation technology of the product will answer many questions that may arise.

1. In SUI and as the condition is resulting from pelvic floor muscles weakness that leads to insufficient closure of urethra, basically a material that acts as a bulking agent is needed in order to act in increased tissue thickness at injection site that will aid in complete closure when muscles plays its normal role. and accordingly, the material of choice was DEAE-DEXTRAN ( Diethylaminoethyl- Dextran) , the choice was based upon that Dextran is a Biocompatible , Biodegradable, non-immunogenic molecule.

Dextran: consists of linked glucan with side chains attached to the 3-position of the backbone glucose units, and it is produced by bacterial fermentation process ( non- animal origin ).

Biopolymer GmbH & Co.KG - Germany

Page 9: Urinary Incontinence

Urodex designed Technolgy:2. DEAE-Dextran Biomaterial cannot be introduced by injection

And as the concept of the products is based upon – minimal

Surgical procedure – a carrier material is needed to carry the DEAE-DEXTRAN to site of implantation, the choice of carrier material was the specially designed cross linked hyaluronic acid

Technically adjusted to play the role of a ( carrier ), again the choice was upon that HA is a biocompatible, biodegradable,

Non-immunogenic molecule.

3. After that and as a long duration effect is favorable in treatment of SUI the Specially designed cross linking process was applied to DEAE-DEXTRAN to obtain a cross Linked DEAE-DEXTRANOMERE or what is called a DEAE-Sephadex-Dextran , SephadexIs a trade mark for cross linked dextran, where cross linking process results in a long termDuration of the implant to be degraded gradually.

Biopolymer GmbH & Co.KG - Germany

Page 10: Urinary Incontinence

Urodex designed Technolgy:4. Finally, a ( fine tuning ) process was created by Biopolymer GmbH – Germany to ensure maximum effect results outcome for

the product ( Urodex ) to be unique and distinguished in SUI Treatment options, the ( fine tuning ) was made by creating a positive charge on DEAE-Sephadex – Dextran which stimulates collagen formation in site of implantation and leading by that for optimum results in treatment of SUI by stimulating tissue regeneration process.

Accordingly, DEAE-Sephadex-Dextran is a polycationic cross linked dextran with tissue regeneration stimulating effect.

5. Accordingly, the benefits of Urodex are summarized as following:A. Biocompatible: as the used materials is a natural component of human body tissues, it

is non-immunogenic ( non-animal origin ) , and biocompatibility is optimal due to formation of fibroblast and collagen fibers that surrounds the microparticles.

B. Biodegradable: the used materials are completely degradable with safe clinical profile.C. Long action duration: due to cross linking process that extends up to 5 five years.D. No Migration from implant site: due to positively charged microparticles – the positive

charge plays a role in ( ancoring ) the implant through inter-cellular interactions leading to fibroblasts and collagen fibers surrounding the implant material as well that microparticles size used ensures no migration. ( safe particel size – 80 micron ).

E. Stimulation of collagen formation: due to positive charges.

Biopolymer GmbH & Co.KG - Germany

Page 11: Urinary Incontinence

Urodex Kit:

Urodex Kit:4 syringes – 1.0ml2 sterile needles 20G1 Applicator1 catheter

Biopolymer GmbH & Co.KG - Germany

Page 12: Urinary Incontinence

Urodex Applicator Special design for minimal

invasive and safe implantation

Controlled implantation in a 4-position (3, 6, 9, 12) symmetrical placement with injection volume of 1.0ml per position.

Periurethral Injection technique.

Biopolymer GmbH & Co.KG - Germany

Page 13: Urinary Incontinence

Urodex Applicator Designed with measurements

for implantation in precise site. After measurement of urethra by

catheter , transfer the length to the applicator, insert the applicator into urethra to the previosuly marked measurement and inject the implant material.

Video is available for procedure.

Biopolymer GmbH & Co.KG - Germany

Page 14: Urinary Incontinence

URODEX Injection Introduce mounted

needle in the applicator

Important! Opening of the needle in direction upward

Biopolymer GmbH & Co.KG - Germany

Page 15: Urinary Incontinence

The Implantation 1 syringe/1 ml in

position 3

Biopolymer GmbH & Co.KG - Germany

Page 16: Urinary Incontinence

The Implantation 1 syringe/1 ml in

position 9

Biopolymer GmbH & Co.KG - Germany

Page 17: Urinary Incontinence

The Implantation 1 syringe/1 ml in

position 12

Biopolymer GmbH & Co.KG - Germany

Page 18: Urinary Incontinence

The Implantation 1 syringe/1 ml in

position 6

Biopolymer GmbH & Co.KG - Germany

Page 19: Urinary Incontinence

Clinical trialsBiopolymer GmbH & Co.KG - Germany

Page 20: Urinary Incontinence

Biopolymer GmbH & Co.KG - Germany

Thank you