URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March...

34
Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA

Transcript of URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March...

Page 1: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

Master Use Major Revision/Recommendation Design Guidance Meeting

March 21st, 2017

DPD Project Number : 3027199 / 3021375

URBANGREENV I L L A

Page 2: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

TABLE OF CONTENTS

2 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

DEVELOPMENT OBJECTIVES

RECOMMENDATION MEETING SUMMARY

ARCHITECTURAL CONCEPT

LANDSCAPING CONCEPT

MATERIALS

3

4

8

26

30

TABLE OF CONTENTS

Page 3: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

DEVELOPMENT OBJECTIVES

3March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

We expect the Urban Green Villa Project to bring an increased level of vitality to the community along this part of 3rd Avenue and surroundings by virtue of being a 24/7 occupied building. Urban Green Villa will bring lights-on after-hours to this block, as well as generating business for its own retail space, and surrounding businesses in the area. The canopies along the 3rd Avenue and Battery Street frontages will be an asset to residents, retail customers, and also to commuters along this part of the 3rd Avenue transit corridor. Landscaping is planned to soften the line between project and city, to create a relaxed and engaging pedestrian flow, and will be designed in concert with planned transit stops.

Our goal is to create a project that engages the Belltown and larger community, creates opportunities for cultural, work, and residential living, and brings human scale and nature to the street along this block. We do this by shaping the street level through landscaping, retail and residential lobbies, by introducing green walls and gardens (sky garden), and by drawing cues from traditional architecture in the area, such as bay windows, which signify residential occupancy, but freshly interpreted.

NEIGHBORHOOD ATMOSPHERE

2401 3rd Avenue, Seattle, WA

Lots 7 and 8, block 25, second addition to that plat of the city of Seattle as laid off by A.A. Denny and W.N. Bell (Commonly known as Bell & Denny’s 2nd Addition to the city of Seattle), according to the plat thereof, recorded in volume 1 of plats, page 77, in King County, Washington.

065600-0215

DMR/R 125/65

12,960 sf

12 floor - Mixed-use residential building containing:• 132 Residential Units• 5,000 sf ground floor retail

space• 73 parking stalls (underground)

PROJECT DATA:Building Address:

Legal Description:

Assessor’s Tax Parcel #:

Current Zoning:

Gross Lot Area:

Project Description:

STREET VIEW : BUILDING CORNER AT 3RD AVENUE & BATTERY STREET

Page 4: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

RECOMMENDATION MEETING SUMMARY

4 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

BOARD DIRECTION

1. Refine the cascading green notch to accommodate additional plant layering and growth in both upward and downward directions and revise the glazing beyond to a material such

as concrete or brick. (A-2, B-4, D-2)2. Revise the multi-story green wall to one story. (D-2)

GREEN NOTCH

STREET VIEW - ALONG BATTERY STREETHANGING VINE WITH VERTICAL TRELLIS

REFERENCE IMAGE

Within the green notched area on south building facade, hanging vine strengthen the continuity of vertically oriented Green characteristics with a cascading effect. For maintaining wide visibility to the community, hanging vine wall is recessed by 4’ from property line.Configuration of stepped sky terraces on L7, L9 and L11 is the same as scheme 1. Also the configuration of living wall on L1 and L2 is the same as scheme 1 for wider visibility to the community.

CASCADING PLANTING SCHEME

Page 5: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

RECOMMENDATION MEETING SUMMARY

5March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

GREEN NOTCH - ORIGINAL

FLOOR PLAN (LEVEL 3)

CONTINUOUS VERTICAL GREEN FEATURE

• 2’ recessed Full Height Vine Wall from Level 1 through Level 6 for continuous Green effect.

• Street level planter for additional layer of Green Feature, providing clean environment and protection for Living Wall.

FLOOR PLAN (LEVEL 1)

GREEN NOTCH

TERRACED VERTICAL GREEN FEATURE

• 4’ recessed Planter with Hanging Vines from Level 3 through Level 6 to repeat terracing effect of upper floors of Green Feature.

• 2’ recessed Living Wall from Level 1 through Level 2 for parmanent Green Accent.

• Street level planter for additional layer of Green Feature, providing clean environment and protection for Living Wall.

FLOOR PLAN (LEVEL 3)

FLOOR PLAN (LEVEL 1)

Page 6: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

RECOMMENDATION MEETING SUMMARY

6 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

EARLY DESIGN GUIDANCE October 20, 20151) Streetscape: The board gave direction on the architectural expression related to the streetscape.a. Discussing the podium options for the tower, the Board unanimously supported

Option B as the transparent base expression promotes pedestrian interaction. (Guidelines C1, C3.1)

b. Acknowledging that brick material is characteristics of Belltown, the Board questioned if the proposed strip of brick on the street level facade is consistent with the overall concept. The Board recommended further developing the street level facade and directed the applicant to provide a brick option and an alternate cladding option at the next meeting. (Guidelines B4)

STREET SCAPE AND MATERIAL DETAILING

MATERIAL REFERENCE IMAGE(MODULAR BRICK FINISH - STACK BOND)

STREET VIEW ALONG 3RD AVENUE (LOOKING SOUTH)

FACADE DIAGRAM - 3RD AVENUEFACADE DIAGRAM - 3RD AVENUE

PODIUM WINDOW LAYOUTWindows are aligned to accent panels above.

BOARD DIRECTION

5. For the podium, refine the brick size to fit the module. (B-4)6. Extend the storefront glazing down to the sidewalk. (B-4, C-1)

Page 7: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

RECOMMENDATION MEETING SUMMARY

7March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

STREET SCAPE AND MATERIAL DETAILING

STREET VIEW ALONG 3RD AVENUE (LOOKING SOUTH)

BOARD DIRECTION

5. For the podium, refine the brick size to fit the module. (B-4)6. Extend the storefront glazing down to the sidewalk. (B-4, C-1)

FACADE -STOREFRONT GLAZING - 3RD AVENUE

Page 8: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

ARCHITECTURAL CONCEPT

8 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

With building design elements of repetitive building massing pattern of staggered bay windows and reduced scaled pattern for the building mass with a residential entry, the Project strengthen the neighborhood characteristics to suite for majority of new local residents.

The residential entry is designed with an enhanced building identity signage and a community friendly green wall for lively appearance to the neighborhood.

3RD AVENUE FACADE

Page 9: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

ARCHITECTURAL CONCEPT

9March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

In addition to unique characteristics of bay windows, historically recognized brick facade creates strong horizontal connection to both new and histrical neighboring buildings.

Within the community consisted with mixture of historical low-rise buildings and newer existing massive buildings, vertically applied Green Strip/ Notch softens urban massing environment that we are anticipating in the near future.

BATTERY STREET FACADE

Page 10: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

10 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

KEY FACTORS

ADJUSTED FACADE EXPRESSION - PUNCHED WINDOWS ON ALL FACADES

• Energy Saving - Lowering the Building Transparency Rate impacts on Energy Cost

• Providing Operable Window for Natural Ventilation - Establish Minimum Standard of Indoor Air Quality Performance, Reduce VOC

• Adding Rooftop Solar Panel - Generating Renewable Energy On Site• Escalating Construction Cost of Window Wall System• More Consistent with Surrounding Neighborhood Context• Maximizes Glazing Area for The Type of System• Reinforces the residential use character of the building • Provides better consistency with other facades within the Belltown

district

Heat Loss ( Original Facade - 20,507 sf, 245,264 BTUH Loss New Facade - 18,173 sf, 217,349 BTUH Loss)

Page 11: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

11March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

Heat Loss ( Original Facade - 20,507 sf, 245,264 BTUH Loss New Facade - 18,173 sf, 217,349 BTUH Loss)

SOUTH FACADE COMPARISON

CURRENT PROPOSED FACADEORIGINALLY PROPOSED FACADE - PUNCHED WINDOWS ON ALL FACADES- WINDOW WALL ON EAST AND NORTH FACADES

40.22% TOTAL GLAZED 41.89% TOTAL GLAZED AREA

Page 12: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

12 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

EAST ELEVATION COMPARISON

CURRENT PROPOSED ELEVATIONORIGINALLY PROPOSED ELEVATION - PUNCHED WINDOWS ON ALL FACADES - WINDOW WALL ON EAST AND NORTH FACADES

NOTE: THIS ELEVATION IS FOR WINDOW OPENING COMPARISON ABOVE 3RD FLOOR. FOR 2ND FLOOR WINDOW LAYOUT, PLEASE REFER TO RENDERINGS IN PREVIOUS PAGES.

39.7% TOTAL GLAZED 40.6% TOTAL GLAZED

Page 13: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

13March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

39.7% TOTAL GLAZED

EAST FACADE COMPARISON

CURRENT PROPOSED FACADEORIGINALLY PROPOSED FACADE - PUNCHED WINDOWS ON ALL FACADES- WINDOW WALL ON EAST AND NORTH FACADES

29.6% TOTAL GLAZED 40.4% TOTAL GLAZED

Page 14: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

14 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

SOUTH ELEVATION COMPARISON

CURRENT PROPOSED ELEVATIONORIGINALLY PROPOSED ELEVATION - PUNCHED WINDOWS ON ALL FACADES- WINDOW WALL ON EAST AND NORTH FACADES

NOTE: THIS ELEVATION IS FOR WINDOW OPENING COMPARISON ABOVE 3RD FLOOR. FOR 2ND FLOOR WINDOW LAYOUT, PLEASE REFER TO RENDERINGS IN PREVIOUS PAGES.

40.6% TOTAL GLAZED AREA43.1% TOTAL GLAZED AREA

Page 15: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

15March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

CURRENT PROPOSED FACADE - MATERIAL CONFIRMATION

GREEN NOTCH - BUILDING COMPONENTS PAINTED GLAZING VINYL WINDOW - BUILDING COMPONENTS

BUILDING FACADE COMPONENTS

GROUND FACE CMU - WITH WATER REPELLENT

REPLACED WITH PAINTED GLAZING VINYL WINDOW, TYP.

IN ORDER TO MAINTAIN REPETITIVE FACADE OPENING DESPITE STRUCTURAL ELEMENTS BEHIND, THESE PANELS WILL BE REPLACED WITH WINDOWS W/ PAINTED GLAZING WITH FRAMED WALL BEHIND.

PREFINISHED WIRE MESH TRELLIS

LEVEL 1120' - 10"

LEVEL 2137' - 0"

LEVEL 3147' - 7"

LEVEL 4157' - 2"

LEVEL 5166' - 9"

LEVEL 6176' - 4"

LEVEL 7185' - 11"

LEVEL 8195' - 6"

LEVEL 9205' - 1"

LEVEL 10214' - 8"

LEVEL 11224' - 3"

LEVEL 12233' - 10"

TOP OF PENTHOUSE266' - 11"

1245678 2.13.14.15.1

LEVEL R1244' - 11"

BASE ELEVATION120' - 11"

85' FROM BASE POINT205' - 11"

TOP OF AMENITY246' - 2"125' HEIGHT LIMIT

245' - 11"

LEVEL R2257' - 5"

35.9

DRAWN BY:PM:

DATE DESCRIPTION

© GWest Architecture, LLC. All rights reserved. No part of this document maybe reproduced in any form or by any means without permission in writing fromGWest Architecture, LLC

A

B

C

D

E

F

G

H1 2 3 4 5 6 7 8 9 10

GWest Architecture, LLC.

address :3601 Fremont Ave. N., Suite 314

Seattle, WA 98301, USA.

Phone : 206.812.8886Fax : 206.812.8885

gwestarch.com

NOT FOR CONSTRUCTION

1/3/

2017

11:

41:0

6 AM

BIM

360

://G

15-0

08 3

RD

& B

ATTE

RY/

G15

-008

3rd

&Bat

tery

_Cen

tral.r

vt

2401 3RD AVE.SEATTLE, WA 98121

Unnamed

01/03/17

P_A3.09

Author-

G15-008

2401 3RD AVE.CD 100%

12/30/2016GWest Architecture, LLC/ Lee Loveland

15-0

01

SCALE: 1/8" = 1'-0"1 0_EAST ELEVATION Copy 1

Page 16: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

LEXI

NGTO

N AP

ARTM

ENTS

LEXI

NGTO

N AP

ARTM

ENTS

ARCHITECTURAL CONCEPT

+121.90

+120.50

+121.50

+120.13

+118.35

16 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

108’

108’

120’

120’

+120.40

L1 FLOOR PLAN

LEGEND

RESIDENTIALRETAILAMENITYCOMMON AREAPUBLIC TERRACEMEPGARAGEPROPERTY LINE

Page 17: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

ARCHITECTURAL CONCEPT

17March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

108’

108’

120’

120’

108’

108’

120’

120’

L2 FLOOR PLAN L3 - L6 TYPICAL FLOOR PLAN

LEGEND

RESIDENTIALRETAILAMENITYCOMMON AREAPUBLIC TERRACEMEPGARAGEPROPERTY LINE

Page 18: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

ARCHITECTURAL CONCEPT

18 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

108’

108’

120’

120’

108’

108’

120’

120’

L7 - L8 TYPICAL FLOOR PLAN L9 - L10 TYPICAL FLOOR PLAN

LEGEND

RESIDENTIALRETAILAMENITYCOMMON AREAPUBLIC TERRACEMEPGARAGEPROPERTY LINE

Page 19: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

ARCHITECTURAL CONCEPT

19March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

108’

108’

120’

120’

L11 - L12 TYPICAL FLOOR PLAN ROOFTOP (R1) FLOOR PLAN

120’

120’

108’

108’LEGEND

RESIDENTIALRETAILAMENITYCOMMON AREAPUBLIC TERRACEMEPGARAGEPROPERTY LINE

Page 20: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

ARCHITECTURAL CONCEPT

+120.05+121.90

20 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

PROP

ERTY

LINE

89’-8”(90’ max allowed for building modulation above 65’ along 3rd Ave)

PROP

ERTY

LINE

125’-

0”(M

AXIM

UM H

EIGH

T ALL

OWED

FOR

THE

SIT

E)

16’-6

”10

’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

11’-1

”23

’-0”

120’-11”BASE ELEVATION

EAST ELEVATION

Page 21: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

ARCHITECTURAL CONCEPT

+121.90+120.40

21March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

PROP

ERTY

LINE 14’-4”

2’-0”Alley setback

PROP

ERTY

LINE

125’-

0”(M

AXIM

UM H

EIGH

T ALL

OWED

FOR

THE

SIT

E)

16’-6

”10

’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

11’-1

”23

’-0”

120’-11”BASE ELEVATION

SOUTH ELEVATION

Page 22: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

ARCHITECTURAL CONCEPT

+120.40+118.35

22 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

PROP

ERTY

LINE

PROP

ERTY

LINE

125’-

0”(M

AXIM

UM H

EIGH

T ALL

OWED

FOR

THE

SIT

E)

16’-6

”10

’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

11’-1

”23

’-0”

120’-11”BASE ELEVATION

WEST ELEVATION

Page 23: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

ARCHITECTURAL CONCEPT

+118.35+120.05

23March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

PROP

ERTY

LINE

PROP

ERTY

LINE

125’-

0”(M

AXIM

UM H

EIGH

T ALL

OWED

FOR

THE

SIT

E)

16’-6

”10

’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

9’-7”

11’-1

”23

’-0”

120’-11”BASE ELEVATION

NORTH ELEVATION

BOARD DIRECTION

8. Revise the blank walk treatment to a uniform dark painted surface. (C-3)

Page 24: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

ARCHITECTURAL CONCEPT

24 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

LEGEND

RESIDENTIALRETAILAMENITYCOMMON AREATERRACEMEPGARAGEPROPERTY LINE

PROP

ERTY

LINE

PROP

ERTY

LINE

NORTH - SOUTH ELEVATION

Page 25: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

ARCHITECTURAL CONCEPT

25March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

LEGEND

RESIDENTIALRETAILAMENITYCOMMON AREATERRACEMEPGARAGEPROPERTY LINE

PROP

ERTY

LINE

PROP

ERTY

LINE

EAST - WEST ELEVATION

Page 26: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

LANDSCAPING CONCEPT

26 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

Page 27: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

LANDSCAPING CONCEPT

27March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

BOARD DIRECTION

3. Provide adequate size for the rooftop tree planters to enable healthy tree growth. (B-4, D-2)

Page 28: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

LANDSCAPING CONCEPT

28 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

The key design element of rooftop features is Green Design, a continuous design feature of the Project elevated from ground level landscaping.

Functionality of rooftop Green Design provides practical aspects of “Green Effects for Residents” to the highest level of the Project.

In addition, the dog park with artificial turf supports Green Effect to the rooftop environment.

ROOFTOP LANDSCAPING DESIGN

Signature rooftop tree(Reminds users that they are a part of the nature)

Perimeter planter(Add framing effect to enhance the rooftop community area)

Rooftop pedestal paver(Lighter material color to reduce solar heat gain)

Dog Park(Communicaion area among dogs/ owners)

P-Patch(Area to appreciate nature for plant/ vegetable growth)

BOARD DIRECTION

3. Provide adequate size for the rooftop tree planters to enable healthy tree growth. (B-4, D-2)

Page 29: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

ROOFTOP RAILING SYSTEM

29March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

LANDSCAPING AND ARCHITECTURAL DETAILING - RAILING

ROOF EDGE CONDITIONRoof edge condition consists of 1’ setback ,2’+ high metal parapet wall with 2’+ high glass guardrail that provides transparency to reduce visual heavyness from street view.

BOARD DIRECTION

4. For the parapet/guardrail detailing, either provide a glass railing or prefabricated black flat stop guardrail with vertical rails. (A-2, B-4)

Page 30: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

MATERIALS

30 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

BUILDING MATERIAL DATA:

METAL FINISHMT1: ACCENT PANEL Color: Silver Metalic System: Formed Aluminum

MT2: MISCELLANEOUS METAL Color: Dark Gray System: Prefinished Aluminum

MT3: METAL CLADDING (ROOFTOP) Color: Dark Gray System: Prefinished Aluminum

MT4: METAL MULLION (WINDOW WALL) Color: Dark Gray System: Window Wall System

FIBER CEMENT FINSIHFC1: MAIN PANEL Color: Dark Gray System: Swiss Pearl/ Carat

FC2: ACCENT PANEL Color: Coral System: Swiss Pearl/ Carat

MASONRY FINISHBR1: BRICK VENEER (STACK BOND) Color: Red Brown System: Brick veneer

PAINT FINISHPT1: MAIN COLOR Color: Light Gray/ PANTONE 420C System: Polyurea Coating

PT2: DARK COLOR Color: Medium Gray/ PANTONE 424C System: Polyurea Coating

PT3: ACCENT COLOR Color: Coral/ PANTONE 1675C System: Polyurea Coating

GLAZINGGL1: INSULATED LOW-E GLASS Color: Clear System: Double Glazing (1/2” Air Gap) Data: 11% reflectance out, 68% transmittance

NORTH WALL COLOR

MT1

GL1

BR1

FC2

FC1

MT2,3,4

PT3PT2PT1

Page 31: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

MATERIAL

31March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

1.

Page 32: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

Board Recommendation, the following departures were requested:

1. Loading Berth (SMC 23.54.035): The Code requires two loading berths 35’ in length. The applicant proposes two loading berths measuring 10’ in width and 25’ in length.

Proposed two (2) loading berths measuring 10’ in width X 25’ in length. Required number of loading berths is proposed. In order to accommodate expected active retail businesses on the ground level, two (2) loading berths (25’ in length) are proposed. The project consists of one bedroom units as majority of residential units and some two bedroom units. Therefore, for the project, small size of loading berths are suggested for practical operation.

For MUP # 3021375,The Board unanimously supported the departure request asconsolidating the loading berth size allows for additional retail/commercial space and better meets Design Guideline C6.I. Address Alley Functions.

PREVIOUSLY APPROVED DEPARTURE - LOADING BERTH

32 March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

Page 33: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

Board Recommendation, the following departures were requested:2. Maximum Width, Depth and Separation (SMC 23.49.164.A): The Code specifies a 90’ maximum width for the portion of a structure above 65’ along and parallel to Avenues. The applicant proposes 105’ for the west façade for levels 7 and 8.

Proposed West side of the building on L7 and L8 to be beyond 90 feet in width (105 feet) parallel to 3rd Avenue with the condition of less than 120 feet in depth (105 feet) parallel to Battery Street (east/west street). For the purpose of breaking the mass facing Battery Street, notched building spaces as sky terraces were created. In order to create feasible and attractive building volume for the site at the same time following the guidance / regulation, the project design applied with positive justifications of regulation was carried out. Design Guidelines: A-1 / Respond to the physical environment, A-2/ Enhance the skyline, B-2/ Create a transition in bulk and scale, B-4 / Design a well- proportioned and unified building.

For MUP # 3021375,The Board unanimously supported the departure request since the volume added to the upper floors is less than the volume removed for the notches, which creates interest and design logic for the whole building. The resulting design better meets Design Guidelines A2 Enhance the skyline, B2 Create a transition in bulk & scale and B4 Design a well-proportioned & unified building.

PREVIOUSLY APPROVED DEPARTURE - MAXIMUM WIDTH,DEPTH AND SEPARATION

ROOF TERRACACACACEACROOF TERRACER F TER ACE

RACERACERACERACERAROOF TERROOF TERROO T RR

UNIT

UNIT

UNIT

RROOF TER TERRACETERRACEACEROOF TERRACER OF TER ACE

TRASHSH

MECH./ELEC.L

ELEV.ELEV

ELEV.

UNIT

UNIT

UNITU UNITN

UNIT

F TOP UNITTTITTTTTTTNOFORORORORROOOOORR P UNNNNITN TTN TNN TTTNNOOF TOPRORRORORORRRO

UNIT UNIT

DEPARTURE REQUEST

UNIT

50 June 14, 20162401 3RD AVENUE / DownTown DRB Recommendation Meeting / GWest Architecture, LLC

DEVELOPMENTSTANDARD

REQUIREMENT PROPOSED RATIONAL

DEPARTURE REQUEST #3

SMC 23.49.164.A

Maximum Width, Depth and Separation

Width and Depth Limits.A maximum width and depth for the portion of a structure above 65 feet in height is 90 feet on Avenues and 120 feet on east/ west streets. The maximum applies to the width and depth of portions of structure as measured parallel to any street lot line.

Proposed west side of the building on L7 and L8 to be beyond 90 feet in width (105 feet) parallel to 3rd Avenue with the condition of less than 120 feet in depth (105 feet) parallel to Battery Street (east/ west street).

For the purpose of breaking the mass facing Battery street, notched buiding spaces as sky terraces were created. In order to create feasible and attractive building volume for the site at the same time following the guidance/ regulation, the project design

Design Guidelines: A-1/ Respond to the physical environment, A-2/ Enhance the skyline, B-2/ Create a transition in Bulk & scale,

L7 - L8 TYPICAL FLOOR PLAN BUILDING FACADE FACING BATTERY STREET

BUILDING FACADE FACING 3RD AVENUE

Battery StreetAREAS CREATED FOR POSITIVE BUILDING CHARACTER

Adjacent Property

BALANCED AREA (L7 & L8)

3rd A

venu

e90

’Ma

ximum

Widt

hBa

lance

d ou

t buil

ding

secti

on15’

40’-4”

Alley

DNDN

PUUPUPPPPPP

PUBLICCLUPPUBLICTTERRACETERRACEECARTTERRACE

33'--66

""

DNDN

RELOCATED VOLUMEMinimized visibility in Avenue street view13,465 cf.

REMOVED VOLUMEAdded Facade Modulationfor community enhancement28,379 cf.

65’

± 20

481 sf

603 sf

PROPOSEDPROPOSEDPROPOSEDPROPOSED

PROPOSEDPROPOSEDPROPOSEDPROPOSED

DESIGN GUIDELINES

A-1: Respond to the physical environment.A-2: Enhance the skyline.B-2: Create a transition in bulk & scale.

building.C-2: Design facades of many scales.D-1: Provide inviting & usable open space.D-2: Enhance the buidling with landscaping.D-5: Provide adequate lighting.

ROOF TERRACACACACEACROOF TERRACER F TER ACE

RACERACERACERACERAROOF TERROOF TERROO T RR

UNIT

UNIT

UNIT

RROOF TER TERRACETERRACEACEROOF TERRACER OF TER ACE

TRASHSH

MECH./ELEC.L

ELEV.ELEV

ELEV.

UNIT

UNIT

UNITU UNITN

UNIT

F TOP UNITTTITTTTTTTNOFORORORORROOOOORR P UNNNNITN TTN TNN TTTNNOOF TOPRORRORORORRRO

UNIT UNIT

DEPARTURE REQUEST

UNIT

50 June 14, 20162401 3RD AVENUE / DownTown DRB Recommendation Meeting / GWest Architecture, LLC

DEVELOPMENTSTANDARD

REQUIREMENT PROPOSED RATIONAL

DEPARTURE REQUEST #3

SMC 23.49.164.A

Maximum Width, Depth and Separation

Width and Depth Limits.A maximum width and depth for the portion of a structure above 65 feet in height is 90 feet on Avenues and 120 feet on east/ west streets. The maximum applies to the width and depth of portions of structure as measured parallel to any street lot line.

Proposed west side of the building on L7 and L8 to be beyond 90 feet in width (105 feet) parallel to 3rd Avenue with the condition of less than 120 feet in depth (105 feet) parallel to Battery Street (east/ west street).

For the purpose of breaking the mass facing Battery street, notched buiding spaces as sky terraces were created. In order to create feasible and attractive building volume for the site at the same time following the guidance/ regulation, the project design

Design Guidelines: A-1/ Respond to the physical environment, A-2/ Enhance the skyline, B-2/ Create a transition in Bulk & scale,

L7 - L8 TYPICAL FLOOR PLAN BUILDING FACADE FACING BATTERY STREET

BUILDING FACADE FACING 3RD AVENUE

Battery StreetAREAS CREATED FOR POSITIVE BUILDING CHARACTER

Adjacent Property

BALANCED AREA (L7 & L8)

3rd A

venu

e90

’Ma

ximum

Widt

hBa

lance

d ou

t buil

ding

secti

on15’

40’-4”

Alley

DNDN

PUUPUPPPPPP

PUBLICCLUPPUBLICTTERRACETERRACEECARTTERRACE

33'--66

""

DNDN

RELOCATED VOLUMEMinimized visibility in Avenue street view13,465 cf.

REMOVED VOLUMEAdded Facade Modulationfor community enhancement28,379 cf.

65’

± 20

481 sf

603 sf

PROPOSEDPROPOSEDPROPOSEDPROPOSED

PROPOSEDPROPOSEDPROPOSEDPROPOSED

DESIGN GUIDELINES

A-1: Respond to the physical environment.A-2: Enhance the skyline.B-2: Create a transition in bulk & scale.

building.C-2: Design facades of many scales.D-1: Provide inviting & usable open space.D-2: Enhance the buidling with landscaping.D-5: Provide adequate lighting.

33March 21st, 20172401 3RD AVENUE / Master Use Major Revision/ Recoomendation Design Guidance Meeting / GWest Architecture, LLC

Page 34: URBAN GREEN VILLA - Seattle...Master Use Major Revision/Recommendation Design Guidance Meeting March 21st, 2017 DPD Project Number : 3027199 / 3021375 URBAN GREEN VILLA TABLE OF CONTENTS

NORTH FACADE COMPARISON

CURRENT PROPOSED FACADEORIGINALLY PROPOSED FACADE