Page 2: Update Meeting

Final Combustion Data

Fuel Gross Heat of Combustion Standard Deviation

RKA ULSD 44.532 MJ/kg 1.184

Cert. ULSD 42.879 MJ/kg 0.532

Yellow Grease 2 38.273 MJ/kg 0.319

White Grease Next Diesel 38.266 MJ/kg 0.342

Soy 38.262 MJ/kg 0.749

Soy Next Diesel 37.774 MJ/kg 0.885

Palm Oil 37.931 MJ/kg 0.321

Poultry Fat 37.107 MJ/kg 0.976

Cotton Seed 38.236 MJ/kg 1.039

Page 3: Update Meeting

Final Combustion Data (con’t)

Fuel Net Heat of Combustion Difference

RKA ULSD 41.662 MJ/kg 2.870

Cert. ULSD 40.009 MJ/kg 2.870

Yellow Grease 2 35.776 MJ/kg 2.497

White Grease Next Diesel 35.854 MJ/kg 2.412

Soy 35.796 MJ/kg 2.466

Soy Next Diesel 35.315 MJ/kg 2.459

Palm Oil 35.359 MJ/kg 2.572

Poultry Fat 34.712 MJ/kg 2.395

Cotton Seed 35.757 MJ/kg 2.478

Page 4: Update Meeting

Final Combustion Data (con’t)

Fuel H:C Ratio Weight % H

RKA ULSD 1.86 13.35%

Cert. ULSD 1.86 13.35%

Yellow Grease 1.63 11.77%

White Grease Next Diesel 1.51 11.37%

Soy 1.65 11.62%

Soy Next Diesel 1.66 11.59%

Palm Oil 1.64 12.12%

Poultry Fat 1.53 11.29%

Cotton Seed 1.71 11.68%

Page 5: Update Meeting

Cold Filter Update

• Temperature controller– Jeremy is obtaining the special plug to hook

up to laptop– Will get plugs for heaters’ power supply– Cannot access program until temperature

controller is in computer

• Can now operate program from desk

Page 6: Update Meeting

Cold Filter Update (con’t)

• Added another thermocouple– Designed to take ambient temperature of

freezer– Will run temperature controller from this one

and fuel tank only– Thermocouple in filter will be collected but not

controlled

Page 7: Update Meeting

Future Work

• Temperature controller– Finish the heaters– Hook-up to laptop and program

• Do preliminary test runs with ULSD