UNIVERSITY TEXAS OF THE PERMIAN BASIN STC Lab 2216 …
Transcript of UNIVERSITY TEXAS OF THE PERMIAN BASIN STC Lab 2216 …
PROJECT LOCATION
385
YUKON RD.
52ND
UNIVERSITY
KERMIT HWY.
34721936
338
BUS20
I. 20
CR
AN
E16TH ST.
8TH ST.
2020
GR
AN
T
GO
LD
ER
CLEMENTS
2ND ST.
DIX
IE B
LV
D.
GO
LD
ER
A
VE
.
W. L
OO
P
33
8
302
AN
DR
EW
S H
WY
.
W. C
OU
NT
Y R
D.
338
1882
JB
S/P
AR
KW
AY
GR
AN
DV
IEW
MID
LA
ND
CO
.
338
MURPHY
UNION PACIFIC RAILROAD
8TH ST.
E. LOOP 338
191
338
554
EC
TO
R C
O.
To M
idla
nd191
To Midland
GR
AN
DV
IEW
46TH
LE
E
MONAHANS
42ND
40TH
38TH
22ND ST.
SA
N F
ER
NA
ND
OC
ON
OV
ER
38TH
TO
M G
RE
EN
AV
E.
I. 20
BUS20
MID
LA
ND
CO
.
EC
TO
R C
O.
AT
TS
XETE FO
SA
JAY
K.BRADFORD
15 2 4 4
REG
IS
TERED ARCHITEC
T
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texas
432-362-6565
www.jsarch.com
8/9/
2016
4:5
4:31
PM
A360
://20
16-2
2 UT
PB S
TC L
AB 2
216
Finis
h Ou
t/201
6-22
UTP
B ST
C LA
B 22
16 Fi
nish
Out
.rvt
A.0.0
COVER SHEET
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
A.0.0 COVER SHEET
A.0.1 ACCESSIBILITY
A.2.0 FLOOR PLAN, CEILING PLAN, SCHEDULES
A.2.1 INTERIOR ELEVATIONS & LAB EQUIPMENT SCHEDULE
Index to Drawings
ARCHITECTURAL
MECHANICAL
PLUMBING
M.0.1 Mechanical Details & SchedulesM.1.1 Mechanical Floor Plans
P.0.1 Plumbing Details & SchedulesP.1.1 Plumbing Floor Plans
Design Team
JSA ArchitectsArchitectOdessa, Texas
Agnew Associates, Inc.MPE Engineer
Lubbock, Texas
UNIVERSITY TEXAS OF THE PERMIAN BASINUNIVERSITY TEXAS OF THE PERMIAN BASINUNIVERSITY TEXAS OF THE PERMIAN BASINUNIVERSITY TEXAS OF THE PERMIAN BASIN
STC Lab 2216 Finish OutSTC Lab 2216 Finish OutSTC Lab 2216 Finish OutSTC Lab 2216 Finish Out
1VICINITY MAP
ELECTRICAL
E.0.1 Electrical Legend & SchedulesE.0.2 Electrical DetailsE.0.3 Electrical Riser DiagramE.1.1 Floor Plan - Electrical DemolitionE.2.1 Floor Plan - LightingE.3.1 Floor Plan - Power & CommunicationsE.4.1 Floor Plan - Fire Alarm & Equipment
RFP# 742-17-080
ADULTS - 2012 T.A.S. STANDARDS
OF DEADLOCKOR PUSH PLATE
OF HOSPITALARM PULL(VERTICAL TYPE)
OF ROLLERLATCH AND OFHOSPITALPUSH - PULLLATCH
OF DOORPULL GRIPAND OFPUSH - PULL PAIR
OF LEVERHANDLE, LATCHAND CROSS BARON FIRE EXIT DEVICE
THRESHOLD1/2" MAX.
DOOR HARDWARE LOCATIONSDOOR HARDWARE LOCATIONSDOOR HARDWARE LOCATIONSDOOR HARDWARE LOCATIONS SIGNAGESIGNAGESIGNAGESIGNAGE
F.F. F.F.
38
" 45
"
47
"
48
"
MIN.
9"
LATC
H S
IDE O
F DO
OR
DIMENSIONS OF PARKING SPACESDIMENSIONS OF PARKING SPACESDIMENSIONS OF PARKING SPACESDIMENSIONS OF PARKING SPACESREFER TO SITE PLAN FOR NUMBER AND LOCATIONS
OF ACCESSIBLE AND VAN-ACCESSIBLE SPACES
WHERE ACCESSIBLESPACE IS 132" WIDEPROVIDE ADDITIONALSIGNAGE ON POLE TOREAD "VAN-ACCESSIBLESPACE" MOUNTED 60" MIN.ABOVE GROUND TOBOTTOM OF SIGN
POLE MOUNTED ACCESSIBLE SIGNAGEIN ACCORDANCE WITH SUBSECTION 502.62012 TAS STANDARDS - LOCATED 60" MIN.ABOVE THE GROUND
ACCESSAISLE
60" MIN. 96" MIN.
FOR VANS
132" MIN
CURB RAMPSCURB RAMPSCURB RAMPSCURB RAMPS
36" MIN.
FLAREDSIDE
FLAREDSIDE
110
110
IF 'X' IS LESS THAN 36"THEN THE SLOPE OF THEFLARED SIDE SHALL NOTEXCEED 1:12
CURB RAMP TO BE INACCORDANCE WITH SECTION406 IN THE 2012 TAS STANDARDS
***
SLO
PE U
P 1:12
MAX.
42
"
F.F.
HIG
HEST
OPE
RABLE
PARTS
WHIC
HARE E
SSENTI
AL
TO B
ASIC
OPE
RATI
ON O
F TE
LEPH
ONE
27
" C
LE
AR
, M
IN.
46
" M
AX
. T
O
TO
SP
OU
T
36
" M
AX
.
TO
SP
OU
T
40
"
PUBLIC DEVICESPUBLIC DEVICESPUBLIC DEVICESPUBLIC DEVICES
PUBLICPUBLICPUBLICPUBLICTELEPHONETELEPHONETELEPHONETELEPHONE
ELECTRICELECTRICELECTRICELECTRICDRINKINGDRINKINGDRINKINGDRINKINGFOUNTAINFOUNTAINFOUNTAINFOUNTAIN
'X'
SLOPE DOWN
1:12 MAX.
SLOPE
DOWN
1:12 M
AX.
CURB RAMPSCURB RAMPSCURB RAMPSCURB RAMPS
CURB
60"
36" MIN.
F.F. F.F.
TO
P O
F S
EA
T
18
"
15
" M
IN.
TOILET ACCESSIBLETOILET ACCESSIBLETOILET ACCESSIBLETOILET ACCESSIBLE TOILET ACCESSIBLETOILET ACCESSIBLETOILET ACCESSIBLETOILET ACCESSIBLE
GRAB BARS
JUMBO TOILET PAPERDISPENSER
TOILET PAPERDISPENSER
TO
P O
F S
EA
T
18
"
FLUSH LEVER TOALWAYS POINT TOWARDSTHE WIDE SIDE OF THETOILET SPACE
GR
IPP
ING
SU
RF
AC
E
33
" -
36
" T
OP
OF
MAX.
12" 42" MIN.
36" MIN. 6"
GR
IPP
ING
SU
RF
AC
E
33
" -
36
" T
OP
OF
17"- 18"
40
" M
AX
.
F.F. F.F.
LAVATORY - ACCESSIBLELAVATORY - ACCESSIBLELAVATORY - ACCESSIBLELAVATORY - ACCESSIBLE LAVATORY - ACCESSIBLELAVATORY - ACCESSIBLELAVATORY - ACCESSIBLELAVATORY - ACCESSIBLE
74
" M
IN.
RE
FL
EC
TIV
E S
UR
FA
CE
40
" M
AX
. T
O B
OT
TO
M O
F
34
" M
AX
.
MIRROR
SOAP DISPENSER
ACCESSIBLETRIM
EQUIPMENTAREAM
EC
HA
NIS
M -
44
" M
AX
.
48
" M
AX
. T
O O
PE
RA
TIN
G
34
" M
AX
.
MIN.
8"
27
" M
IN.
9"
MIN
.
6" MAX. 11" MIN.15" MIN.
F.F.
URINALURINALURINALURINAL
PLANCLEAR
30" MIN.
EQ EQURINAL SCREEN
42
" M
AX
.
17
" M
AX
.
TAPERED ELONGATEDRIM
7"-9"
13
1/2
" M
IN.
CURB RAMP TO BE INACCORDANCE WITH SECTION406 IN THE 2012 TAS STANDARDS
STANDARD ROLL-IN TYPE SHOWER W/O SEATSTANDARD ROLL-IN TYPE SHOWER W/O SEATSTANDARD ROLL-IN TYPE SHOWER W/O SEATSTANDARD ROLL-IN TYPE SHOWER W/O SEAT
CLEAR FLOORAREA
60" MIN.
30
" M
IN.
INS
IDE
DIM
EN
SIO
N
30
" M
IN. C
LE
AR
CLEAR FLOORAREA
TRANSFER TYPE 36" x 36" SHOWER W/ SEATTRANSFER TYPE 36" x 36" SHOWER W/ SEATTRANSFER TYPE 36" x 36" SHOWER W/ SEATTRANSFER TYPE 36" x 36" SHOWER W/ SEAT
INSIDE DIMENSION
36" CLEAR
36
" M
IN.
INS
IDE
DIM
EN
SIO
N
36
" C
LE
AR
48" MIN.
1' - 6"
HIG
HE
R T
HA
N 2
7"
80
" M
IN.
4" MAX.
F.F.
PROTRUDING OBJECTSPROTRUDING OBJECTSPROTRUDING OBJECTSPROTRUDING OBJECTSTHESE DETAILS APPLY TO ALL ITEMS PERMANENTLY MOUNTED TO A WALLALONG THE ACCESSIBLE ROUTE - REFER TO SECTION 307 & 403
REFER TO SECTION 404.2.7
48
" M
AX
.
34
" M
IN.
REFER TO SECTION 703.4
CENTERLINE OFTACTILE CHARACTERS
DOOR FRAME
REFER TO SECTIONS 217, 308, 704 & 602
48
" M
AX
.
12
" M
IN.
MIN
.
1 1
/2"
54" MIN.
REFER TO SECTION 604 & 609 REFER TO SECTION 604 & 609
24" MIN.
MIN.
12"
MIN
.
1 1
/2"
REFER TO SECTION 605
INSULATE WATER SUPPLYAND DRAIN PIPES UNDERLAVATORY TO PREVENTCONTACTINSULATE WATER SUPPLY
AND DRAIN PIPES UNDERLAVATORY TO PREVENTCONTACT
AT
CO
UN
TE
RT
OP
REFER TO SECTIONS 305, 306 & 606 REFER TO SECTIONS 305, 306 & 606
17" - 25"
REFER TO SECTION 502
SLO
PE 1:
20
MAX.
SLOPE1:20 MAX.
REFER TO SECTION 608 REFER TO SECTION 608
BACK WALL
SE
AT
WA
LL
CO
NT
RO
L W
ALL
SID
E W
AL
L
SID
E W
AL
L
BACK WALL
MA
X.
6"
MAX.
6"
MAX.
6"
MA
X.
6"
INSIDE DIMENSION
60" MIN. CLEAR
2012 T
.A.S
. S
TA
ND
AR
DS
DO
OR
CL
OS
ER
S A
ND
ST
OP
S
78
" M
IN. T
O B
OT
TO
M O
F
ED
GE
OF
WA
LL
FIN
ISH
ACCESSIBLE ROUTE
36" MIN. CLEAR
* REFER TO SECTION 604 FOR ADDITIONAL REQUIREMENTS
F.F.
SINK - ACCESSIBLESINK - ACCESSIBLESINK - ACCESSIBLESINK - ACCESSIBLE
EQUIPMENTAREA
INSULATE WATER SUPPLYAND DRAIN PIPES UNDERLAVATORY TO PREVENTCONTACT
MIN.
8"
9"
MIN
.
6" MAX. 11" MIN.
27
" M
IN.
34
" M
AX
.
REFER TO SECTIONS 305, 306 & 606
LO
WE
ST
TA
CT
ILE
CH
AR
AC
TE
R
48
" M
IN. T
O B
AS
EL
INE
OF
AREA OFREFUGE
HIG
HE
ST
TA
CT
ILE
CH
AR
AC
TE
R
50
" M
AX
. T
O B
AS
EL
INE
OF
FIRE PROTECTION DEVICESFIRE PROTECTION DEVICESFIRE PROTECTION DEVICESFIRE PROTECTION DEVICES
F.F.
FIREFIREFIREFIREEXTINGUISHEREXTINGUISHEREXTINGUISHEREXTINGUISHER
FIREFIREFIREFIREEXTINGUISHEREXTINGUISHEREXTINGUISHEREXTINGUISHERCABINETCABINETCABINETCABINET
FIRE VALVEFIRE VALVEFIRE VALVEFIRE VALVECABINET WITHCABINET WITHCABINET WITHCABINET WITHEXTINGUISHEREXTINGUISHEREXTINGUISHEREXTINGUISHER
48
" T
O R
EL
EA
SE
BR
AC
KE
T
48
" M
AX
. T
O O
F H
AN
DL
E
48
" M
AX
. T
O O
F H
AN
DL
E
48
" T
O O
F V
AL
VE
REFER TO SECTION 308 & 309ACCESSORIESACCESSORIESACCESSORIESACCESSORIES
SHELF WHEREAPPLICABLE
F.F.
72
"
40
" M
IN. -
48
" M
AX
.
40
" M
IN. -
48
" M
AX
.
34
"
MOP ANDMOP ANDMOP ANDMOP ANDBROOMBROOMBROOMBROOMHOLDERHOLDERHOLDERHOLDER
COATCOATCOATCOATHOOKHOOKHOOKHOOK
DIAPERDIAPERDIAPERDIAPERCHANGINGCHANGINGCHANGINGCHANGINGSTATIONSTATIONSTATIONSTATION(OPEN)(OPEN)(OPEN)(OPEN)
TOWEL BARTOWEL BARTOWEL BARTOWEL BAR
REFER TO SECTION 603.4
27
" C
LE
AR
, M
IN.
F.F.
PAPER TOWEL DISPENSERPAPER TOWEL DISPENSERPAPER TOWEL DISPENSERPAPER TOWEL DISPENSER
48
" M
AX
.
REFER TO SECTION 308 & 606.1
AT
TS
XETEFO
SA
JAY
K.BRADFO
RD
1524 4
REGIS
TERED
ARCH
ITECT
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texas
432-362-6565
www.jsarch.com
8/8/
2016
3:5
1:59
PM
A360
://20
16-2
2 UT
PB S
TC L
AB 2
216
Finis
h Ou
t/201
6-22
UTP
B ST
C LA
B 22
16 Fi
nish
Out
.rvt
A.0.1
ACCESSIBILITY
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
GENERAL NOTES
PLAN LEGEND
KEYED NOTESX
NEW METAL STUD WALL CONSTRUCTION
X KEYED NOTE - REFER THIS SHEET
DOOR NUMBERDOOR TAG
HARDWARE SET
FIRE RATING
HW1hrXXX
1i PARTITION TYPE - REFER TO SHEET A.2.1
1
4' - 6"
VE
RIF
Y
11
' - 0
7/8
"1
2' -
1 3
/4"
6' -
10
1/4
"
15' - 4" 8' - 9 3/8" VERIFY
2215
COMPUTER
2215A
STORAGE
2215B
LAB
1
1
2
MIN.1' - 6"
2
4
5
6
67
888
7' - 9 1/8"
2 2
3' - 11 1/4"
9
3
10
1111
2
3
3
3
3
3
3
11
7
10
10
10
A.2.1
1
2
9 9 9
4' - 0" 4' - 0" 4' - 0" 3' - 11 1/4"
9 9 9 9
3' -
0 9
/16
"3
' - 0
9/1
6"
2---2215A
1---2215B
12
12
12
A1
A1
A1
A1
A1
MIN.12".
13
DOOR SCHEDULE
DOOR FINISHES
GLAZING SCHEDULE
MARK GLASS TYPE
OVERALLUNIT
THICKNESSTHICKNESSEACH LITE OUTDOOR LITE
OUTDOOR LITECOATING
INTERSPACECONTENT
INDOORLITE
WINTERU-FACTOR
SUMMERU-FACTOR SHGC
VISIBLE LIGHTTRANSMITTANCE NOTES
A 1/4" GLASS,CLEAR
1/4" 6.0 MM N/A N/A N/A N/A N/A N/A N/A N/A FULLY TEMPERED GLASS LITESWITH SAFETY GLAZING LABELING IN
LOCATION REQUIRED BY CODE
ROOM FINISH SCHEDULE
FINISHES
SCALE 1/4" = 1'-0"
DOOR ELEVATIONS
F.F.
FRAME AS SCHED.
DOOR AS SCHED.
A B
HE
IGH
T A
S S
CH
ED
.2
"
2"
AS SCHED.WIDTH 2"
FRAME AS SCHED.
DOOR AS SCHED.
TYPE 'A' VISIONPANEL
HE
IGH
T A
S S
CH
ED
.2
"
2"
AS SCHED.WIDTH 2"
3' -
7"
2' -
4"
6"
4
4 4
2 x 4 LIGHT FIXTURE
2 x 2 SUSPENDED LAY-IN CEILING
ROOM NUMBER101
PARTITION ASSCHED.
DBL. MTL. STUDHEADER AT HEAD;DBL. MTL. STUDSAT JAMB
FRAME AS SCHED.
FULL 1/2" RETURN -BOTH SIDES
DOOR AS SCHED.
2"
1/2"
5 7/8"
1
1
1
2215
COMPUTER
2215A
STORAGE
2215B
LAB
141414
STC LAB
ELECTRICAL ROOM
KEYPLAN
AREA A
AREA BAREA C
AT
TS
XETE FO
SA
JAY
K.BRADFORD
15 2 4 4
REG
IS
TERED ARCHITEC
T
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texas
432-362-6565
www.jsarch.com
8/9/
2016
3:3
4:33
PM
A360
://20
16-2
2 UT
PB S
TC L
AB 2
216
Finis
h Ou
t/201
6-22
UTP
B ST
C LA
B 22
16 Fi
nish
Out
.rvt
A.2.0
FLOOR PLAN,CEILING PLAN,SCHEDULES
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
1 EXISTING TO REMAIN - NO WORK.
2 CLEAN, TAPE, FLOAT, TEXTURE AND PAINT ALL EXISTING WALLS TO 8" ABOVECEILING.
3 EXISTING FOSSIL CABINETS BY OWNER
4 4'-0" WIDE BASE CABINETS WITH EPOXY RESIN COUNTER TOP & SINK WITHADJUSTABLE SHELVES ABOVE
5 8'-0" WIDE FUME HOOD (HF RATED FOR ACIDS) WITH ACID & FLAMMABLE BASECABINETS
6 4'-0" WIDE STUDENT DESK WITH CABINET AND ADJUSTABLE METAL SHELVINGABOVE
7 EXISTING TABLE BY OWNER
8 4'-0" WIDE WET BENCH WITH BASE CABINET AND ADJUSTABLE METAL SHELVESABOVE
9 3'-0"X3'-0" COMPUTER TABLES, OWNER PROVIDED
10 EXISTING STORAGE SHELF UNIT BY OWNER
11 WALL MOUNTED MONITOR BY OWNER
12 EXISTING DOOR, DOOR FRAME AND HARDWARE
13 REMOVE REQUIRED PORTIONS OF EXISTING PARTITION FOR INSTALLATION OFNEW ELECTRICAL PANEL, PATCH AND REPAIR PARTITION AS REQUIRED -COORDINATE WITH ELECTRICAL SHEETS.
14 2'-0"X2'-0" CEILING SERVICE PANEL
A. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND REPORT ANY DISCREPANCYTO THE ARCHITECT FOR CORRECTION BEFORE PROCEEDING WITHCONSTRUCTION.
B. ALL DIMENSIONS SHOWN ARE FROM FACE OF STUD
C. BLOCKING SHALL BE REQUIRED IN ALL STUD WALLS TO RECEIVE HANDRAILS,GRAB BARS, SHELVING, DOOR STOPS, AND ALL OTHER SIMILAR ITEMS REQUIRINGA SECURE ANCHOR.
D. THE GENERAL CONTRACTOR WILL BE REQUIRED TO COORDINATE ALL TRADES ASNECESSARY TO INSTALL ALL HANGING DEVICES FOR INSTALLATION OF ALLPIPING, MECHANICAL AND ELECTRICAL SYSTEMS.
E. REFER TO MPE SHEETS FOR ADDITIONAL REQUIREMENTS.
SCALE: 1/4" = 1'-0"1
FLOOR PLAN
2 40 168
MARK
SIZE (W x H)
FRAME
DOOR DETAILS
NOTESWIDTH HEIGHT DOOR MATERIAL THICKNESS ELEV. HEAD JAMB SILL TRANSOM
2215A 3' - 0" 7' - 0" F1 D1 1 3/4" A 3 3 SIM. --- --- HARDWARE TO BE PROVIDEDUNDER HARDWARE ALLOWANCE,REFER TO SPECIFICATIONSECTION 01 21 00
2215B 3' - 0" 7' - 0" F1 D1 1 3/4" B 3 3 SIM. --- --- HARDWARE TO BE PROVIDEDUNDER HARDWARE ALLOWANCE,REFER TO SPECIFICATIONSECTION 01 21 00
DOOR MATERIALS
D1 SOLID CORE WOOD TO MATCH EXISTING
FRAME MATERIALS
F1 HOLLOW METAL
ROOMNO. ROOM NAME
FLOORFINISH
BASEFINISH
WALLFINISH
WAINSCOTFINISH
CEILINGFINISH
CEILINGHEIGHT COMMENTS
2215 COMPUTER F1 B1 W1, W2 --- C1 9'-0" ---
2215A STORAGE F1 B1 W1, W2 --- C1 9'-0" ---
2215B LAB F1 B1 W1, W2 --- C1 9'-0" ---
WALLS
W1 PAINTED NEW GYPSUM BOARD
W2 TAPE, FLOAT, TEXTURE AND PAINT EXISTING GYPSUM BOARD
BASE
B1 NEW RUBBER BASE
CEILINGS
C1 LAY-IN CEILING
FLOORING
F1 VINYL COMPOSITION TILESCALE: 1 1/2" = 1'-0"
4HEAD / JAMB SIM.
SCALE: 1/4" = 1'-0"2
REFLECTED CEILING PLAN
2 40 168
EXISTING TABLES BYOWNER
3 3 3
2 2 2
4 4 4
6
2
1 1 18
14 14 14
7 13
2
6
8
5
9 10 11 12
CEILING AS SCHED.
UNFACED SOUNDATTENUATION BLANKETS
BASE AS SCHEDULED
1/2
"
METAL DECK
1/2
"
CONT. FIRE RATED SEALANTBOTH SIDES - MATCH RATINGOF PARTITION.ACOUSTICAL SEALANT ATNON RATED PARTITIONS
A1
TYPE DESCRIPTION
FULL HT. GWB 3 5/8"
STUD SIZE
NR
RATING
49
STC
---
TEST NO.
4 7/8"
DIMENSION
DIM.
FIN. FLOOR
CONT. MTL. CHANNELRUNNER
CONT. FIRE RATED SEALANTBOTH SIDES - MATCH RATINGOF PARTITION.ACOUSTICAL SEALANT ATNON RATED PARTITIONS
TOP SLIP JOINT: CONT. MTL.CHANNEL RUNNER. DO NOT
FASTEN TO STUDS. ANCHORTO STRUCTURE & PROVIDE
STUD BRACING AGAINSTRACKING
HEAD
PLAN
SILL
5/8" TYPE X GWB -FULL HEIGHT BOTH SIDES
SOLID FIRE TREATED WOODBLOCKING AT CASEWORKLOCATIONS AS REQUIREDPLACE BACK TO BACK
BOXES IN SEPERATE STUDCAVITY TO REDUCE SOUND
TRANSMISSION
METAL STUD FRAMINGAT 16" O.C. EXTEND TO
STRUCTURE ABOVE(SEE BELOW FOR SIZES)
CONT. 14 GA. CLOSUREPLATE WHERE PARTITIONIS PARALLET TO FLUTES
LABRATORY CASEWORK AND EQUIPMENT
NOTES
80850 - PROVIDE HOSE CONNECTORS ON ALL FIXTURES AND PROVIDE ALL FIXTURES WITH VACUUM BREAKERS
AT
TS
XETE
FO
SA
JAY
K.BRADFO
RD
1524 4
REGIS
TERED ARCH
ITECT
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texas
432-362-6565
www.jsarch.com
8/9/
2016
3:4
4:14
PM
A360
://20
16-2
2 UT
PB S
TC L
AB 2
216
Finis
h Ou
t/201
6-22
UTP
B ST
C LA
B 22
16 Fi
nish
Out
.rvt
A.2.1
INTERIORELEVATIONS & LAB
EQUIPMENTSCHEDULE
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
SCALE: 1/4" = 1'-0"1 LAB 2215B - NORTH
SCALE: 1/4" = 1'-0"2 LAB 2215B - SOUTH
SCALE: 1" = 1'-0"3 PARTITION TYPE A
TAG ITEM # DESCRIPTION SERVICES TOPS/REMARKS
1 MOTT VT00248 48"x32"x30H SINGLE SIDED, STUDENTDESK
TWO RECEPTICALES INHORIZONTAL RACEWAY.FOUR RECEPTCALES INLOWER POST.
30" BLACK EPOXY RESIN
2 MOTT 1150222 18" SUSPENDED CABINET
3 MOTT VSS1448 TOP SHELF
4 MOTT SAV1248 LOWER SHELF
5 MOTT 7571040 SAFEGUARD FUME HOOD DUCTWORK, BLOWERMOTOR AND VAV FUMEHOOD CONTROLLER BYMECHANICAL CONTRACTOR
6 MOTT FSH1248MOTT FSB0012
48" WALL MOUNTED SHELVING SYSTEM- 3 TIERS 12" DEEP, TOP SHELFINVERTED.
7 MOTT FSH1242MOTT FSB0012
42" WALL MOUNTED SHELVING SYSTEM- 3 TIERS 12" DEEP, TOP SHELFINVERTED.
8 MOTT OTF0248 48"x28"x29"H" U-FRAME LEGSTRETCHED
30" BLACK EPOXY RESIN
9 MOTT1516022-VK ACID
48"x22"x35"H SPECIALTY BASE CABINETWITH LOW PROFILE CUPSINK
10 MOTT1512022-FL
48"x22"x35"H SPECIALTY BASE CABINET
11 MOTT 1518022 48"x22"x35"H BASE CABINET 30" BLACK EPOXY RESIN
12 MOTT 1510011 48"x22"x35"H BASE CABINET 30" BLACK EPOXY RESIN WITH CUT OUTFOR SINK
13 DURCON 3030 30"X30" PEG BOARD WITH DRIP TRAY
14 MOTT OSP0002 24"X24" CEILING SERVICE PANEL SIX SERVICE ACCESS HOLESAND SIX ELECTRICAL CUTOUTS
OVAL RETURN OR EXHAUST DUCT TURNED UP
OVAL RETURN OR EXHAUST DUCT TURNEDDOWN
CHANGE OF ELEVATION IN DIRECTIONINDICATED (D=DROP, R=RISE)
DIFFUSER W/ AIR PATTERN
OVAL SUPPLY DUCT TURNED DOWN
OVAL SUPPLY DUCT TURNED UP
RETURN, EXHAUST OR TRANSFER AIR GRILLE
SIDEWALL SUPPLY GRILLE OR REGISTER
SIDEWALL RETURN, EXHAUST ORTRANSFER AIR GRILLE
LINEAR AIR DEVICE
MANUAL BALANCING DAMPERWITH CONCEALED REGULATOR
MANUAL BALANCING DAMPER
MOTORIZED DAMPER
HOUR FIRE DAMPER
COMBINATION FIRE / SMOKE DAMPER
SMOKE DAMPER
HORIZONTAL FIRE DAMPER
FLEX DUCT
FLEX CONNECTION
ACCESS DOOR
MITERED ELBOW (TURNING VANES UNO)
RADIUS ELBOW (1.5 RADIUS UNO)
CONCENTRIC TRANSITION(1 IN 4 MAX SLOPE)
ECCENTRIC TRANSITION(1 IN 4 MAX SLOPE)
CL
MECHANICAL GENERAL NOTES
ABBREV
AAV ABV A/C AD AF AFC AFF AFG AHU ANSI AMCA AP APPROX ARCH ARI ASME ASTM AUX
B BCU BDD BFC BFF BFG BFP BHP BI BLDG BOD BOP BSMT BTU
CD CFH CFM CH CHP CHR CHS CIRC CL CLG CM CMU CO CONC COND CONN CONT CR CRAC CRAH CT CWR CWS CU CV CW
D DB DEG DG DIA DIFF DMPR DN DWG DX
EA EAG EAT EDH EF EH ELEC ELEV EMERG ENT EOM EQUIP ESP EWT EVAP EX EXH
F or °F FCU FD FLEX FLG FLR FM FO FPB FPM FS FT
GAL GALV GC GPH GPM
H HB HD HOA HP HR HW HWP HVAC HZ
ABBREV
ID IE IN INSUL IN WG
KW
L LAT LAV LB LIN FT LPG LRA LVR
MAX MBD MBH MECH MIN MS
NA NC NIC NO NTS
OA OAH OBD OC OD
PBD PCHP PCHR PCHS PD PH PHL PLUMB PNL PPM PRESS PRV PRV PSIG
QTY
RA RAG RAH RE REQ'D REV RH RHC RM RPM RTU
PRV
SA SAF SCH SCHP SD SEC SECT SF SHT SQ SS STD STM SURF SUSP SW SYS
TEMP THL TLL TP TSP TSTAT TU TXV TYP
UF UG UH UNO
V VAV VB VEL VENT VERT VF VOL VTR
W W/ W/O WB WG WT
Ø
MECHANICAL ABBREVIATIONS
DESCRIPTION
AUTOMATIC AIR VENT ASSEMBLYABOVEAIR CONDITIONEDACCESS DOORAIR FLOWABOVE FINISHED CEILINGABOVE FINISHED FLOORABOVE FINISHED GRADEAIR HANDLING UNITAMERICAN NATIONAL STANDARD INSTITUTEAIR MOVING AND CONDITIONING ASSOCIATION, INC.ACCESS PANELAPPROXIMATEARCHITECTURALAIR CONDITIONING & REFRIGERATION INSTITUTEAMERICAN SOCIETY OF MECHANICAL ENGINEERSAMERICAN SOCIETY FOR TESTING MATERIALSAUXILIARY
BOILERBLOWER COIL UNITBACK DRAFT DAMPERBELOW FINISHED CEILINGBELOW FINISHED FLOORBELOW FINISHED GRADEBACKFLOW PREVENTERBRAKE HORSEPOWERBACKWARD INCLINEDBUILDINGBOTTOM OF DUCTBOTTOM OF PIPEBASEMENTBRITISH THERMAL UNIT
CONDENSATE DRAIN LINE OR CONTROL DAMPERCUBIC FEET PER HOURCUBIC FEET PER MINUTECHILLERCHILLED WATER PUMPCHILLED WATER RETURNCHILLED WATER SUPPLYCIRCULATINGCENTER LINECEILINGCONSTRUCTION MANAGERCONCRETE MASONRY UNITCLEANOUTCONCRETECONDENSATECONNECTIONCONTINUATIONCONDENSATE RETURNCOMPUTER ROOM AIR CONDITIONERCOMPUTER ROOM AIR HANDLERCOOLING TOWERCONDENSING WATER RETURNCONDENSING WATER SUPPLYCONDENSING UNITCONTROL VALVEDOMESTIC COLD WATER
DRAINDRY BULBDEGREESDOOR GRILLEDIAMETERDIFFUSERDAMPERDOWNDRAWINGDIRECT EXPANSION
EACH OR EXHAUST AIREXHAUST GRILLEENTERING AIR TEMPERATUREELECTRIC DUCT HEATEREXHAUST FANEXHAUST HOODELECTRICALELEVATIONEMERGENCYENTERINGEND OF MAINEQUIPMENTEXTERNAL STATIC PRESSUREENTERING WATER TEMPERATUREEVAPORATOREXISTINGEXHAUST
DEGREES FAHRENHEITFAN COIL UNIT OR FURNACE & COIL UNITFIRE DAMPERFLEXIBLEFLANGEFLOORFACTORY MUTUALFLAT OVAL DUCTFAN-POWERED BOXFOOT PER MINUTEFLOW SWITCHFEET, FOOT
GALLONGALVANIZEDGENERAL CONTRACTORGALLON PER HOURGALLON PER MINUTE
HIGH, HEIGHTHOSE BIBBHEAD IN FEETHAND-OFF-AUTOHORSE POWER OR HEAT PUMPHOURHEATING / VENTILATING / AIR CONDITIONINGDOMESTIC HOT WATERHEATING WATER PUMPHERTZ
DESCRIPTION
INSIDE DIAMETERINVERT ELEVATION ( FLOW LINE)INCHESINSULATIONINCHES OF WATER
KILOWATT(S)
LONG, LENGTHLEAVING AIR TEMPERATURE LAV OR LAVATORYPOUNDLINEAL FOOTLIQUID PROPANE GASLOCKED ROTOR AMPSLOUVER
MAXIMUMTHOUSAND BTU / HRMANUAL BALANCING DAMPERMECHANICALMINIMUMMOTOR STARTER
NOT APPLICABLENORMALLY CLOSEDNOT IN CONTRACTNORMALLY OPENNOT TO SCALE
OUTSIDE AIROUTSIDE AIR INTAKE HOODOPPOSED BLADE DAMPERON CENTEROUTSIDE DIAMETER
PARALLEL BLADE DAMPERPRIMARY CHILLED WATER PUMPPRIMARY CHILLED WATER RETURNPRIMARY CHILLED WATER SUPPLYPRESSURE DROPPHASEPRESSURE HIGH LIMITPLUMBINGPANELPARTS PER MILLIONPRESSUREPOWER ROOF VENTILATORPRESSURE REDUCING VALVEPOUND PER SQUARE INCH. (GAUGE)
QUANTITY
RETURN AIRRETURN AIR GRILLERELIEF AIR HOODREFERREQUIREDREVISED OR REVISIONSRELATIVE HUMIDITYREHEAT COILROOMREVOLUTION PER MINUTEROOF TOP UNIT
POWER ROOF VENTILATOR
SUPPLY AIRSUPPLY FANSCHEDULESECONDARY CHILLED WATER PUMPSMOKE DAMPERSECONDSECTIONSQUARE FOOTSHEETSQUARESERVICE SINK OR STAINLESS STEELSTANDARDSTEAMSURFACESUSPEND OR SUSPENDEDSOFTENED WATERSYSTEM
TEMPERATURETEMPERATURE HIGH LIMITTEMPERATURE LOW LIMITTOTAL PRESSURETOTAL STATIC PRESSURETHERMOSTAT TERMINAL UNITTHERMOSTATIC EXPANSION VALVETYPICAL
UNDERFLOORUNDERGROUNDUNIT HEATERUNLESS OTHERWISE NOTED
VOLT(S)VARIABLE AIR VOLUMEVALVE BOX OR VACUUM BREAKERVELOCITYVENTILATEVERTICALVENTILATION FANVOLUMEVENT THRU ROOF
WASTE OR WIDE, WIDTHWITHWITHOUTWET BULBWATER GAUGEWEIGHT
DELTA
PHASE OR ROUND
EXISTING COMPONENT TO REMAIN
SYMBOL DESCRIPTION
EXISTING COMPONENT TO BE REMOVED
DROP
RISE
RISE OFF TOP
DROP OFF BOTTOM
BRANCH OFF TOP
BRANCH OFF BOTTOM
BRANCH OFF SIDE
CAP
BLIND FLANGE
CONCENTRIC REDUCER
ECCENTRIC REDUCER
SLEEVE
GUIDE
ANCHOR
FLOW DIRECTION
GRADE DOWNWARD
CONNECT TO EXISTING
COMPRESSED AIR
INSTRUMENT AIR
NATURAL GAS - LOW PRESSURE (<1 PSI)
NATURAL GAS - MED. PRESSURE (>1 PSI)
LIQUID PROPANE GAS
GENERAL
LP
MG
G
IA
A
BALL VALVE
BUTTERFLY VALVE
GATE VALVE
GAS COCK
GLOBE VALVE
CHECK VALVE
PRESSURE REDUCING VALVE
MOTORIZED 2-WAY CONTROL VALVE
THERMOSTATIC MIXING VALVE
SOLENOID VALVE
VALVE BOX
WATER METER
BACKFLOW PREVENTER
BALANCING VALVE
UNION
STRAINER W/ BLOW DOWN
GAG PRESSURE REGULATOR
THERMOMETER
PRESSURE GAUGE W/ GAUGE COCK
PETE'S PLUG
PRESSURE SWITCH
FLOW SWITCH
VALVES & ACCESSORIESSYMBOL DESCRIPTION
M
M
S
M
MOTORIZED 3-WAY CONTROL VALVE
AQUASTAT
AUTO AIR VENT
VACUUM RELIEF VALVE
TEMPERATURE & PRESSURE RELIEF
PRESSURE RELIEF VALVE
FLEXIBLE CONNECTION
FS
PS
MECHANICAL LEGEND
AAV
MOTORIZED BUTTERFLY VALVEM
BFP
EXPANSION JOINTEJ
T
H
P
DP
CONTROLSSYMBOL DESCRIPTION
THERMOSTAT
TEMPERATURE SENSOR
HUMIDITY SENSOR
PRESSURE SENSOR
DIFFERENTIAL PRESSURE SENSOR
12X10
DUCTWORK & ACCESSORIESSYMBOL DESCRIPTION
RECTANGULAR DUCT (FIRST DIM VISIBLE)
12Ø
12/10
ROUND DUCT (FIRST DIM VISIBLE)
FLAT OVAL DUCT (FIRST DIM VISIBLE)
RECTANGULAR SUPPLY DUCT TURNED UP
RECTANGULAR RETURN OR EXHAUSTDUCT TURNED UP
R
M
CR
FD
FD/SD or FSD
SD
OR
AD
RECTANGULAR RETURN OR EXHAUSTDUCT TURNED DOWN
ROUND RETURN OR EXHAUSTDUCT TURNED DOWN
ROUND RETURN OR EXHAUST DUCTTURNED UP
FLOW MEASURING DEVICE
TEST WELL
S
MECHANICAL GENERAL DEMOLITION NOTES
DPor
MISC. PIPINGSYMBOL DESCRIPTION
ROUND SUPPLY DUCT TURNED DOWN
ROUND SUPPLY DUCT TURNED UP
RECTANGULAR SUPPLY DUCT TURNED DOWN
AGNEW ASSOCIATES, INC.MECHANICAL & ELECTRICAL CONSULTING ENGINEERSLUBBOCK, TEXAS TEXAS REGISTERED ENGINEERING FIRM F-1005 AUSTIN, TEXAS
PHONE: (806) 799-0753 AAI PROJECT NO. PHONE: (512) 828-0753
FAX: (806) 799-2014 WWW.AGNEWASSOCIATES.COM FAX: (512) 310-0750
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texaskerrville, texas
432-362-6565888-774-6565
www.jsarch.com
8/8/
2016
3:2
7:34
PM
C:\U
sers
\tim
\Doc
umen
ts\R
evit
2016
Pro
ject
s - L
ocal
File
s\12
1601
1 M
EP C
entr
al Fi
le R
16_t
im.rv
t
M0.1
MECHANICALDETAILS &
SCHEDULES
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
1216011
NATHAN R. AGNEW
91668
STA
ETOF TE
AX
S
PR
O
FESS IONAL ENG
INE
ER
L I CENSED
8/8/168/8/168/8/168/8/16
A PROVIDE ALL MATERIALS, LABOR, AND EQUIPMENT AS REQUIRED TO INSTALLCOMPLETE AND OPERABLE SYSTEMS AS INDICATED ON THE DRAWINGS, AS SPECIFIED,AS REQUIRED BY ALL APPLICABLE CODES, AND PER MANUFACTURER'S DIRECTIONS.
B NO CUTTING SHALL BE DONE TO ANY OF THE STRUCTURAL MEMBERS THAT WOULDTEND TO LESSEN THEIR STRENGTH, UNLESS SPECIFIC PERMISSION IS GRANTED BYTHE ARCHITECT.
C ALL PIPING AND DUCTWORK SHALL BE COORDINATED WITH ALL TRADES INVOLVED.OFFSETS IN PIPING AND DUCTWORK AROUND OBSTRUCTIONS AND AS REQUIRED FORSERVICE SHALL BE PROVIDED AT NO ADDITIONAL COST TO THE OWNER.
D COORDINATE CONSTRUCTION OF ALL WORK WITH ARCHITECTURAL, CIVIL,STRUCTURAL, PLUMBING, ELECTRICAL WORK, ETC., SHOWN ON ALL OTHER CONTRACTDOCUMENT DRAWINGS.
E VERIFY AND COORDINATE ALL FINAL EQUIPMENT SIZES AND CONNECTING SERVICESWITH ACTUAL EQUIPMENT SUBMITTED AND APPROVED & OWNER PROVIDEDEQUIPMENT.
F ALL OPENINGS IN FIRE WALLS FOR DUCTWORK, PIPING, CONDUITS, ETC., SHALL BEFIRE STOPPED WITH A SPECIFIED PRODUCT SIMILAR TO 3M, OR APPROVED EQUAL.
G UNLESS OTHERWISE SHOWN, LOCATE ALL ROOM THERMOSTATS, SENSORS, ANDHUMIDISTATS 4'-0" ABOVE FINISHED FLOOR. LOCATIONS ADJACENT TO DOORS SHALLMAINTAIN A MINIMUM OF 24" FROM FRAME
H ALL DUCTWORK DIMENSIONS AS SHOWN ON THE DRAWINGS, ARE INTERNAL CLEARDIMENSIONS AND DUCT SIZE SHALL BE INCREASED TO COMPENSATE FOR DUCT LINERTHICKNESS, WHERE DUCT LINER IS SPECIFIED.
I COORDINATE MBD, DIFFUSER, REGISTER, AND GRILLE LOCATIONS WITHARCHITECTURAL REFLECTED CEILING PLANS, LIGHTING, AND OTHER CEILING ITEMS.MBD's SHALL BE FULLY ACCESSIBLE. MAKE MINOR DUCT MODIFICATIONS ASREQUIRED.
J LOCATE ALL MECHANICAL EQUIPMENT FOR UNOBSTRUCTED ACCESS TO UNIT ACCESSPANELS, CONTROLS, AND VALVING. MAINTAIN THE MINIMUM SERVICE CLEARANCE PERMANUFACTURER
K RUNS OF FLEXIBLE DUCT SHALL NOT EXCEED 4 FEET OR BEND GREATER THAN 90°.
L PROVIDE ACCESS DOORS IN DUCTWORK FOR ALL FIRE DAMPERS, SMOKE DAMPERS,HUMIDIFIERS, COILS, AND OTHER ITEMS LOCATED IN DUCTWORK WHICH REQUIRESERVICE AND/OR INSPECTION.
M PROVIDE ACCESS PANELS IN WALLS AND CEILINGS TO ALLOW ADEQUATE ACCESS TOEQUIPMENT, VALVES, TRAPS, DAMPERS, CLEANOUTS, CONTROLS, ETC.
A SIZE AND LOCATION OF EXISTING EQUIPMENT, DUCTWORK, PIPING, ETC. SHOWN FORREFERENCE ONLY. FIELD VERIFY EXACT CONDITIONS PRIOR TO BID.
B REMOVE SLEEVES AND PATCH ALL WALLS, FLOORS, AND CEILINGS TO REMAIN WHEREPIPING AND/OR DUCTWORK HAS BEEN REMOVED. PATCHES IN RATED CONSTRUCTIONSHALL MATCH EXISTING MATERIAL TO ENSURE RATING INTEGRITY.
C COORDINATE DEMOLITION WITH GENERAL CONTRACTOR. OWNER SHALL HAVE FIRSTRIGHTS TO ALL REMOVED COMPONENTS. THE REMAINING ITEMS SHALL BECOMPLETELY REMOVED BACK TO ACTIVE SERVICE LOCATION. REMOVE ALLASSOCIATED HANGERS, SUPPORTS, POWER, CONTROLS, ETC.
SS
1
2
EX. 36x30
EX. 14Ø EX. 14Ø
EX. GE-2-201
EX.DD-S2-212
EX. 14Ø
EX. 8Ø
EX. 36x30 EX. 36x30 EX. 28Ø
EX. 1
8Ø
EX. 24Ø
EX
. 24
Ø
EX. 14Ø
EX. 14Ø
EX. GE-2-202
EX. 14Ø
EX
. 1
4x1
2
EX
. 8
Ø
EX
. 18
Ø
EX. 10Ø
EX
. 14
Ø
EX. GE-2-203
2
STORAGE
2215A
COMPUTER
2215
LAB
2215B
34Ø
EX. 14Ø
36x30EX. 36x30
EX. 14Ø
EX. 24Ø
EX. 1
8Ø
EX. 28Ø
EX
. 24Ø
EX
. 18Ø
EX
. 14Ø
EX. 10Ø
EX. 14Ø
EX
. 14x12
EX. 8Ø
EX
. 8Ø
EX. 14Ø
EX. 14Ø
14Ø
EX
. 6Ø
EX. 8Ø
14Ø
14Ø
EX. 36x30
10Ø
EX. 36x30
16x16
5Ø
8Ø
8Ø
8Ø
12Ø 12Ø
9Ø 9Ø
9Ø
9Ø
10Ø 10Ø
8Ø/S-29235 CFM
8Ø/S-29225 CFM
8Ø/S-29225 CFM
12Ø/S-22480 CFM
12Ø/S-22480 CFM
6Ø/S-2215 CFM
18x18/R-1.1
20x20/R-1.1
6x6/R-1.1
EX.DD-S2-212
EX. GE-2-201
LE-2-1-16
3
8x6
16x16
4
4
5
AIR DISTRIBUTION SCHEDULE
NOTE:
1. TB = LAY-IN T- BAR
2. VERIFY FRAME TYPE WITH CEILING INSTALLER'S LAYOUT.
LE-2-1-16
LAB EXHAUST VALVE SCHEDULE
MARK
EXHAUST CFM SIZE
MAX. MIN.
EXAMPLE
EX. GE-2-201
1080
1560
SIEMENS LGE-10
EXISTING
300 10"
0 EX.
ROOM OFFSET
200
CONTROLTYPE
VAV
EX. VAV
NO SCALE
SQUARE TO ROUNDTRANSITION IF REQUIRED.
ROUND SPIN-IN WITH LOCKING MANUALVOLUME DAMPER. PROVIDE STAND-OFF
BRACKET ON INSULATED DUCTWORK.DAMPER NOT REQUIRED ON MOST RETURN
AIR RUNOUTS. REFER TO PLANS.
FLEXIBLE INSULATEDDUCT (MAX. 4'-0" LENGTH)SEE PLAN FOR SIZE. FLEXMAY OCCUR IN VERTICAL.
AIR DEVICE CEILING
TRUNK DUCT
INSULATION AS SPECIFIED
NOTE: 1. THE FLEX DUCT INNER CORE & OUTER INSULATION SHALL BE SECURED SEPARATELY WITH WORM DRIVE STAINLESS STEEL BANDS OR NYLON DRAW BANDS.
2. IF TRUNK DUCT IS NOT DEEP ENOUGH TO ACCEPT ROUND SPIN-IN DAMPER, PROVIDE 45° RECTANGULAR TO ROUND TAKEOFF FITTING W/ DAMPER HAVING SAME DAMPER REQUIREMENTS AS SPIN-IN FITTING DESCRIBED ABOVE.
AIR DEVICE MOUNTING DETAIL - ROUND RUNOUT
RETURN AIR BOOT DETAILNO SCALE
CEILING RETURNAIR GRILLE
2/3 SIZE OFGRILLE NECK
SUSPEND FROMSTRUCTURE ATEACH CORNER
18"
BOOT CONTRUCTED OF 1" RIGIDINSULATION W/ FOIL BACKING ORHIGH DENSITY DUCTBOARD.
SAME SIZE ASGRILLE NECK
NO SCALE
TYPICAL LAB CONTROLS DIAGRAM
CEILING
FUMEHOOD
TOEXHAUST
FAN
LE-2-1-16
TO EXHAUSTFAN
EX. GE-2-201
HD
CD
EX. DD-S2-212
FUME HOODMONITOR/CONTROLLER
EXISTINGROOM CONTROLLER
RETURN
S
SUPPLY
FLOOR
EXISTING SPACETEMPERATURE
SENSOR
A. ROOM SUPPLY/EXHAUST AND EXHAUST HOOD TERMINALS
1. SYSTEM MODULATES SUPPLY AIR TERMINAL TO PROVIDE SUFFICIENT MIXED AIR TO MATCH
SUM OF EXHAUST TERMINALS LESS SCHEDULED OFFSET. SYSTEM MODULATES PERCENTAGE
OF MIXED AIR FROM HOT DECK AND COLD DECK TO MAINTAIN SPACE TEMPERATURE.
2. FUME HOOD EXHAUST TERMINAL MODULATE BETWEEN HOOD MAXIMUM AND HOOD MINIMUM
TO MAINTAIN CORRECT AIR VELOCITY ACROSS SASH OPENING BASED ON SASH HEIGHT.
3. GENERAL EXHAUST TERMINAL: MODULATES IN CONJUNCTION WITH FUME HOOD EXHAUST
TERMINAL AND SUPPLY AIR TERMINAL TO THE VOLUME REQUIRED TO MAINTAIN NEGATIVE
SPACE PRESSURE.
4. TEMPERATURE AND AIR CHANGE SETBACK. BASED ON SCHEDULE PROVIDED BY OWNER,
SPACE TEMPERATURE AND AIR CHANGE RATES SHALL "SETBACK" TO ADJUSTABLE VALUES
DURING SCHEDULED UN-OCCUPIED TIMES.
NOTE: ROOM PRIORITIES FOR LABS
1. PRESURIZATION
2. TEMPERATURE
TYPICAL LAB AIR SYSTEM SEQUENCE OF OPERATION
AGNEW ASSOCIATES, INC.MECHANICAL & ELECTRICAL CONSULTING ENGINEERSLUBBOCK, TEXAS TEXAS REGISTERED ENGINEERING FIRM F-1005 AUSTIN, TEXAS
PHONE: (806) 799-0753 AAI PROJECT NO. PHONE: (512) 828-0753
FAX: (806) 799-2014 WWW.AGNEWASSOCIATES.COM FAX: (512) 310-0750
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texaskerrville, texas
432-362-6565888-774-6565
www.jsarch.com
8/8/
2016
3:2
7:37
PM
C:\U
sers
\tim
\Doc
umen
ts\R
evit
2016
Pro
ject
s - L
ocal
File
s\12
1601
1 M
EP C
entr
al Fi
le R
16_t
im.rv
t
M1.1
MECHANICALFLOOR PLANS
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
1216011
NOTES INDICATED BY " "
NATHAN R. AGNEW
91668
STA
ETOF TE
AX
S
PR
O
FESS IONAL ENG
INE
ER
L I CENSED
8/8/168/8/168/8/168/8/16
1 EXISTING SA DUCT TO BE REMOVED.
2 EXISTING EA DUCT TO BE REMOVED.
3 REBALANCE EXISTING VAV BOX AS FOLLOWS: MIXED AIR - 1660/820 (MAX./MIN.), COLD AIR - 1660/300 (MAX./MIN.),HOT AIR - 580/0 (MAX./MIN.)
4 RA OPENING ABOVE CEILING.
5 10"Ø EXHAUST DUCT DOWN TO FUME HOOD COLLAR. COORDINATE CONNECTION REQUIREMENTS WITH HOODMANUFACTURER.
SCALE: 1/4" = 1'-0"
FLOOR PLAN - MECHANICAL DEMOLITIONNORTHSCALE: 1/4" = 1'-0"
FLOOR PLAN - MECHANICALNORTH
MARK TYPE FRAME SIZE FINISH MATERIAL EXAMPLE
S-22 SUPPLY TB 24x24 WHITE STEEL TITUS TMS
S-29 SUPPLY TB 24x24 WHITE STEEL TITUS TriTec
R-1.1 RETURN TB 24x24 WHITE STEEL TITUS PAR W/ RA BOOT
PLUMBING GENERAL NOTES
EXISTING COMPONENT TO REMAIN
SYMBOL DESCRIPTION
EXISTING COMPONENT TO BE REMOVED
DROP
RISE
RISE OFF TOP
DROP OFF BOTTOM
BRANCH OFF TOP
BRANCH OFF BOTTOM
BRANCH OFF SIDE
CAP
BLIND FLANGE
CONCENTRIC REDUCER
ECCENTRIC REDUCER
SLEEVE
GUIDE
ANCHOR
FLOW DIRECTION
GRADE DOWNWARD
CONNECT TO EXISTING
COMPRESSED AIR
INSTRUMENT AIR
NATURAL GAS - LOW PRESSURE (<1 PSI)
NATURAL GAS - MED. PRESSURE (>1 PSI)
LIQUID PROPANE GAS
IRRIGATION WATER
GENERAL
DRAIN, WASTE, & VENT
SYMBOL DESCRIPTION
SOIL WASTE, OR SANITARY SEWER
VENT
STORM DRAIN
ACID WASTE
ACID VENT
INDIRECT DRAIN
CLEANOUT
DOUBLE CLEANOUT
WALL CLEANOUT
END OF LINE CLEANOUT
VENT THRU ROOF
ROOF DRAIN
OVERFLOW DRAIN
FLOOR DRAIN
FLOOR SINK
HUB DRAIN
OPEN SITE DRAIN
SD
AW
AV
D
I
LP
MG
G
IA
A
. .
.
.
CO
DCO
WCO
CO
VTR
RD
OFD
FD
FS
HD
OSD
RO
DI
BALL VALVE
BUTTERFLY VALVE
GATE VALVE
GAS COCK
GLOBE VALVE
CHECK VALVE
PRESSURE REDUCING VALVE
MOTORIZED 2-WAY CONTROL VALVE
THERMOSTATIC MIXING VALVE
SOLENOID VALVE
VALVE BOX
WATER METER
BACKFLOW PREVENTER
ANGLE VALE
BALANCING VALVE
UNION
STRAINER W/ BLOW DOWN
GAG PRESSURE REGULATOR
THERMOMETER
PRESSURE GAUGE W/ GAUGE COCK
PETE'S PLUG
PRESSURE SWITCH
FLOW SWITCH
VALVES & ACCESSORIESSYMBOL DESCRIPTION
M
M
S
M
MOTORIZED 3-WAY CONTROL VALVE
AQUASTAT
AUTO AIR VENT
TRAP PRIMER
VACUUM RELIEF VALVE
TEMPERATURE & PRESSURE RELIEF
PRESSURE RELIEF VALVE
FLEXIBLE CONNECTION
FS
PS
DOMESTIC COLD WATER LINE
DOMESTIC HOT WATER LINE
HOT WATER RETURN LINE
DOMESTIC WATER
SYMBOL DESCRIPTION
REVERSE OSMOSIS
DEIONIZED WATER
FIRE PROTECTIONSYMBOL DESCRIPTION
FIRE MAIN
AUTO FIRE SPRINKLER
WET FIRE SPRINKLER ALARM ASSEMBLY RISER
DRY FIRE SPRINKLER ALARM ASSEMBLY RISER
FIRE PUMP TEST CONNECTION
SIAMESE FIRE DEPARTMENT CONNECTION
FIRE HYDRANT
UPRIGHT SPRINKLER
PENDENT SPRINKLER
SIDEWALL SPRINKLER
FIRE HOSE CABINET
F
S
FHC
LABORATORY AIRLA
LV LABORATORY VACUUM
LABORATORY SERVICESSYMBOL DESCRIPTION
PLUMBING LEGEND
AAV
BFP
TP
PLUMBING ABBREVIATIONS
ABBREV DESCRIPTION
AAV ABV A/C AD AFC AFF AFG AHU ANSI AP APPROX ARCH ASPE ASME ASTM AUX AV AW AWWA
B BCU BFC BFF BFG BFP BHP BLDG BOD BOP BSMT BTU BV
CA CD CFH CI CIRC CL CLG CM CMU CO CONC COND CONN CONT CT CU CW
D DCO DCW DEG DF DHW DHWR DI DIA DN DS DSN DWG
EA ELEC ELEV EMERG ENT EQUIP EWC EWH EWT EX
F or °F FCU FD FF FG FHC FLEX FLG FLR FM FS FT
GAL GALV GC GEN GPH GPM GW GV
H HB HD HP HR HTR HVAC HW HWP HWR HWRP HZ
AUTOMATIC AIR VENT ASSEMBLYABOVEAIR CONDITIONEDACCESS DOORABOVE FINISHED CEILINGABOVE FINISHED FLOORABOVE FINISHED GRADEAIR HANDLING UNITAMERICAN NATIONAL STANDARD INSTITUTEACCESS PANELAPPROXIMATEARCHITECTURALAMERICAN SOCIETY OF PLUMBING ENGINEERSAMERICAN SOCIETY OF MECHANICAL ENGINEERSAMERICAN SOCIETY FOR TESTING MATERIALSAUXILIARYACID VENTACID WASTEAMERICAN SOCIETY FOR WORKS ASSOCIATION
BOILERBLOWER COIL UNITBELOW FINISHED CEILINGBELOW FINISHED FLOORBELOW FINISHED GRADEBACKFLOW PREVENTERBRAKE HORSEPOWERBUILDINGBOTTOM OF DUCTBOTTOM OF PIPEBASEMENTBRITISH THERMAL UNITBALL VALVE
COMPRESSED AIRCONDENSATE DRAIN LINE OR CONTROL DAMPERCUBIC FEET PER HOURCAST IRONCIRCULATINGCENTER LINECEILINGCONSTRUCTION MANAGERCONCRETE MASONRY UNITCLEANOUTCONCRETECONDENSATECONNECTIONCONTINUATIONCOOLING TOWERCOPPERDOMESTIC COLD WATER
DRAINDOUBLE CLEANOUTDOMESTIC COLD WATERDEGREESDRINKING FOUNTAINDOMESTIC HOT WATERDOMESTIC HOT WATER RETURNDEIONIZED WATERDIAMETERDOWNDOWNSPOUTDOWNSPOUT NOZZLEDRAWING
EACH OR EXHAUST AIRELECTRICALELEVATIONEMERGENCYENTERINGEQUIPMENTELECTRIC WATER COOLERELECTRIC WATER HEATERENTERING WATER TEMPERATUREEXISTING
DEGREES FAHRENHEITFAN COIL UNIT OR FURNACE & COIL UNITFLOOR DRAINFINISH FLOORFINISH GRADEFIRE HOSE CABINETFLEXIBLEFLANGEFLOORFACTORY MUTUALFLOOR SINK OR FLOW SWITCHFEET, FOOT
GALLONGALVANIZEDGENERAL CONTRACTORGENERATORGALLON PER HOURGALLON PER MINUTEGREASE WASTEGREASE VENT
HIGH, HEIGHTHOSE BIBBHEAD IN FEETHORSE POWER OR HEAT PUMPHOURHEATERHEATING / VENTILATING / AIR CONDITIONINGDOMESTIC HOT WATERHEATING WATER PUMPDOMESTIC HOT WATER RETURNHOT WATER RETICULATING PUMPHERTZ
ABBREV DESCRIPTION
ID IE IN INSUL IN WG
KW
L LAT LAV LB LIN FT LPG LRA
MA MAX MB MBH MECH MIN MS MTD MV
N N2O NA NC NG NIC NO NTS
O OA OC OD OFD OH
PD PRESS PRV PSIG PH PLUMB PNL PPM
QTY
RD RE REQ'D REV RM RO RPM PRV RTU
SCH SD SEC SECT SF SHT SQ SS STD STM SURF SUSP SW SYS
TEMP THL TLL TP TSP TSTAT TMV TYP
U UF UG UH UNO
V VB VEL VENT VERT VOL VTR
W W/ W/O WAGD WC WCO WH WG WT
Ø
INSIDE DIAMETERINVERT ELEVATION ( FLOW LINE)INCHESINSULATIONINCHES OF WATER
KILOWATT(S)
LONG, LENGTHLEAVING AIR TEMPERATURELAV OR LAVATORYPOUNDLINEAL FOOTLIQUID PROPANE GASLOCKED ROTOR AMPS
MEDICAL AIRMAXIMUMMOP BASINTHOUSAND BTU / HRMECHANICALMINIMUMMOTOR STARTERMOUNTEDMEDICAL VACUUM
NITROGENNITROUS OXIDENOT APPLICABLENORMALLY CLOSEDNATURAL GASNOT IN CONTRACTNORMALLY OPENNOT TO SCALE
OXYGENOUTSIDE AIRON CENTEROUTSIDE DIAMETEROVERFLOW DRAINOVERHEAD
PRESSURE DROPPRESSUREPRESSURE REDUCING VALVEPOUND PER SQUARE INCH. (GAUGE)PHASEPLUMBINGPANELPARTS PER MILLION
QUANTITY
ROOF DRAINREFERREQUIREDREVISED OR REVISIONSROOMREVERSE OSMOSISREVOLUTION PER MINUTEPOWER ROOF VENTILATORROOF TOP UNIT
SCHEDULESTORM DRAINSECONDSECTIONSQUARE FOOTSHEETSQUARESERVICE SINK OR STAINLESS STEELSTANDARDSTEAMSURFACESUSPEND OR SUSPENDEDSOFTENED WATERSYSTEM
TEMPERATURETEMPERATURE HIGH LIMITTEMPERATURE LOW LIMITTOTAL PRESSURETOTAL STATIC PRESSURETHERMOSTATTHERMOSTATIC MIXING VALVETYPICAL
URINALUNDERFLOORUNDERGROUNDUNIT HEATERUNLESS OTHERWISE NOTED
VOLT(S)VALVE BOX OR VACUUM BREAKERVELOCITYVENTILATEVERTICALVOLUMEVENT THRU ROOF
WASTE OR WIDE, WIDTHWITHWITHOUTWASTE ANESTHESIA GAS DISPOSALWATER CLOSETWALL CLEANOUTWATER HEATER OR WALL HYDRANTWATER GAUGEWEIGHT
DELTA
PHASE or ROUND
PLUMBING GENERAL DEMOLITION NOTES
AGNEW ASSOCIATES, INC.MECHANICAL & ELECTRICAL CONSULTING ENGINEERSLUBBOCK, TEXAS TEXAS REGISTERED ENGINEERING FIRM F-1005 AUSTIN, TEXAS
PHONE: (806) 799-0753 AAI PROJECT NO. PHONE: (512) 828-0753
FAX: (806) 799-2014 WWW.AGNEWASSOCIATES.COM FAX: (512) 310-0750
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texaskerrville, texas
432-362-6565888-774-6565
www.jsarch.com
8/8/
2016
3:2
7:38
PM
C:\U
sers
\tim
\Doc
umen
ts\R
evit
2016
Pro
ject
s - L
ocal
File
s\12
1601
1 M
EP C
entr
al Fi
le R
16_t
im.rv
t
P0.1
PLUMBINGDETAILS &
SCHEDULES
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
1216011
NATHAN R. AGNEW
91668
STA
ETOF TE
AX
S
PR
O
FESS IONAL ENG
INE
ER
L I CENSED
8/8/168/8/168/8/168/8/16
A PROVIDE ALL MATERIALS, LABOR, AND EQUIPMENT AS REQUIRED TO INSTALL COMPLETEAND OPERABLE PLUMBING SYSTEM AS INDICATED ON THE DRAWINGS, AS SPECIFIED, ASREQUIRED BY ALL APPLICABLE CODES, AND PER MANUFACTURER'S DIRECTIONS.
B NO CUTTING SHALL BE DONE TO ANY OF THE STRUCTURAL MEMBERS THAT WOULD TENDTO LESSEN THEIR STRENGTH, UNLESS SPECIFIC PERMISSION IS GRANTED BY THEARCHITECT.
C ALL PIPING SHALL BE COORDINATED WITH ALL TRADES INVOLVED. OFFSETS IN PIPINGAROUND OBSTRUCTIONS AND AS REQUIRED FOR SERVICE SHALL BE PROVIDED AT NOADDITIONAL COST TO THE OWNER.
D COORDINATE CONSTRUCTION OF ALL WORK WITH ARCHITECTURAL, CIVIL, STRUCTURAL,MECHANICAL, ELECTRICAL WORK, ETC., SHOWN ON ALL OTHER CONTRACT DOCUMENTDRAWINGS.
E ALL OPENINGS IN FIRE WALLS FOR DUCTWORK, PIPING, CONDUITS, ETC. SHALL BE FIRESTOPPED WITH A SPECIFIED PRODUCT SIMILAR TO 3M, OR APPROVED EQUAL.
F RUN ALL SOIL, WASTE, AND VENT PIPING WITH 1% MINIMUM GRADE UNLESS OTHERWISENOTED. HORIZONTAL VENT PIPING SHALL BE GRADED TO DRIP BACK TO THE SOIL ORWASTE PIPE BY GRAVITY.
G VERIFY & COORDINATE ALL FINAL EQUIPMENT SIZE AND CONNECTING SERVICES WITHACTUAL EQUIPMENT SUBMITTED AND APPROVED AND OWNER PROVIDED EQUIPMENT.
H PROVIDE SHUTOFF VALVES IN ALL DOMESTIC WATER PIPING SYSTEM BRANCHES. REFERTO DRAWINGS FOR ADDITIONAL VALVE LOCATIONS.
I INSTALL PIPING SO THAT ALL VALVES, STRAINERS, UNIONS, TRAPS, FLANGES, AND OTHERAPPURTENANCES REQUIRING ACCESS ARE ACCESSIBLE.
J REFER TO ARCHITECTURAL PLANS FOR EXACT LOCATION AND ELEVATION OF FLOORDRAINS. GRATE SHALL BE FLUSH W/ ADJACENT FINISHED FLOOR SURFACE.
K PROVIDE CLEANOUTS IN SANITARY AND STORM DRAINAGE SYSTEMS AT ENDS OF RUNS,AT CHANGES IN DIRECTION GREATER THAN 45°, NEAR THE BASE OF STACKS, EVERY 100DEVELOPED FEET AND ELSEWHERE AS INDICATED. ALL CLEANOUTS SHALL BE FULL SIZEOF PIPE FOR PIPE 4" AND SMALLER AND SHALL BE 4" FOR PIPE SIZES LARGER THAN 4".
L PROVIDE ACCESS PANELS IN WALLS & CEILINGS TO ALLOW ADEQUATE ACCESS TOEQUIPMENT, VALVES, TRAPS, DAMPERS, CLEANOUTS, CONTROLS, ETC.
M COORDINATE WITH ELECTRICAL AS REQUIRED TO MAINTAIN 36" OF CLEAR SERVICE SPACEFOR 120V, 208V, AND 230V DEVICES AND 42" CLEAR SPACE FOR 480V DEVICES. THIS SHALLINCLUDE SWITCH GEAR, DISTRIBUTION PANELS, VFDS, STARTERS, DISCONNECTS, ETC.LOCATION OF THE SERVICE SPACE SHALL BE DETERMINED BY THE SPECIFIC
N COORDINATE WITH ELECTRICAL AS REQUIRED TO ROUTE NO DUCT OR PIPE DIRECTLYOVER DEVICES SUCH AS PANELBOARDS, MOTOR CONTROL CENTERS ANDSWITCHBOARDS UNLESS IT IS A MINIMUM OF 6' ABOVE THE TOP OF THE DEVICE, ORPROTECTION FROM DAMAGE FROM THE PIPE OR DUCT IS PROVIDED. THIS SHALL INCLUDENOT ONLY PROTECTION FROM LEAKS, BUT FROM BREAKAGE.
A SIZE AND LOCATION OF EXISTING EQUIPMENT, PIPING, ETC. SHOWN FOR REFERENCEONLY. FIELD VERIFY EXACT CONDITIONS PRIOR TO BID.
B REMOVE SLEEVES AND PATCH ALL WALLS, FLOORS, AND CEILINGS TO REMAIN WHEREPIPING HAS BEEN REMOVED. PATCHES IN RATED CONSTRUCTION SHALL MATCH EXISTINGMATERIAL TO ENSURE RATING INTEGRITY.
C COORDINATE DEMOLITION WITH GENERAL CONTRACTOR. OWNER SHALL HAVE FIRSTRIGHTS TO ALL REMOVED COMPONENTS. THE REMAINING ITEMS SHALL BE COMPLETELYREMOVED BACK TO ACTIVE SERVICE LOCATION. REMOVE ALL ASSOCIATED HANGERS,SUPPORTS, POWER, CONTROLS, ETC.
LVLA
AV AV AV
LA LV
LA
LV
LALV
LVLA
EX. 3"
EX. 1/2" EX. 1/2"
EX. 1/2" EX. 3/4"
EX. 1"
EX. 1 1/2" EX. 1 1/2"
EX. 1 1/2"
EX. 1"
EX. 1 1/2"
EX. 1 1/4" EX. 1 1/2"
EX. 3/4"
EX. 3/4"
EX. 2"
AV
RO
RO
EX. 1 1/2"
EX. 1 1/2"
IN FIRST FLOORINTERSTITIAL SPACE
2
1
STORAGE
2215A
COMPUTER
2215
LAB
2215B
LVLA
AV AV AV
LA LV
LA
LV
LALV
LVLA
EX. 3"
EX. 1/2" EX. 1/2" EX. 1/2"
EX. 3/4"
EX. 1"
EX. 1 1/2" EX. 1 1/2"
EX. 1 1/2"
EX. 1"
EX. 1 1/2"
EX. 1 1/4" EX. 1 1/2"
G
G
LA
LV
AW AW
G
LALV
2" 2" 2"
3/4"
1/2"
1/2"
3/4"
3/4"
3/4"
EX. 3/4"
EX. 3/4" EX. 2"
EX. 2"
EX. 2"3/4"1/2"1/2"
LA
LV
G
LALV
G
1/2"3/4"
3/4"
1/2"
1/2"
1/2" 1/2"1/2"
1/2" 1/2"
1/2"1/2"
1/2"1/2"
1/2"
1/2"
1/2"1/2"
3/4" 1 1/2" 1 1/2"
3
3
4 4 4
5
5
6
7
89
AV AV AV
RO
RO
IN FIRST FLOORINTERSTITIAL SPACE
RO
RORO
EX. 1 1/2"
EX. 1 1/2"
1 1/2"
1 1/2"
1
GAS RISER DETAILNO SCALE
EXISTINGGAS VALVE
EX. 1"
DIRT LEG
TO LAB
EX. 3/4"
FLOOR
CEILING
3/4"
AGNEW ASSOCIATES, INC.MECHANICAL & ELECTRICAL CONSULTING ENGINEERSLUBBOCK, TEXAS TEXAS REGISTERED ENGINEERING FIRM F-1005 AUSTIN, TEXAS
PHONE: (806) 799-0753 AAI PROJECT NO. PHONE: (512) 828-0753
FAX: (806) 799-2014 WWW.AGNEWASSOCIATES.COM FAX: (512) 310-0750
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texaskerrville, texas
432-362-6565888-774-6565
www.jsarch.com
8/8/
2016
3:2
7:41
PM
C:\U
sers
\tim
\Doc
umen
ts\R
evit
2016
Pro
ject
s - L
ocal
File
s\12
1601
1 M
EP C
entr
al Fi
le R
16_t
im.rv
t
P1.1
PLUMBING FLOORPLANS
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
1216011
NATHAN R. AGNEW
91668
STA
ETOF TE
AX
S
PR
O
FESS IONAL ENG
INE
ER
L I CENSED
8/8/168/8/168/8/168/8/16
NOTES INDICATED BY " "
1 CONTRACTOR SHALL FIELD VERIFY EXACT SIZE AND LOCATION OF RO MAIN IN FIRST FLOOR INTERSTITIAL SPACE.
2 REMOVE RO MAIN SHOWN DASHED.
3 RUN GAS LINE 1'-0" BELOW CEILING. PAINT ALL EXPOSED GAS LINES YELLOW (COLOR TO MATCH EXISTING LABS).COORDINATE EXACT COLOR WITH OWNER.
4 1/2" LAB AIR, 1/2" LAB VACUUM AND 1/2" GAS DOWN IN WALL TO LAB BENCH. COORDINATE EXACT CONNECTIONREQUIREMENTS WITH LAB BENCH MANUFACTURER. PROVIDE ESCUTCHEON AT WALL PENETRATION OF GAS LINE.
5 1/2" LAB AIR, 1/2" LAB VACUUM AND 1/2" GAS DOWN TO FUME HOOD. COORDINATE EXACT CONNECTION REQUIREMENTS WITHFUME HOOD MANUFACTURER.
6 1/2" DCW DOWN IN WALL TO FUME HOOD. COORDINATE EXACT CONNECTION REQUIREMENTS WITH FUME HOODMANUFACTURER.
7 GAS RISER (RE: DETAIL)
8 CONNECT 1/2" DCW & 1/2" DHW TO SINK FAUCET. CONNECT 1/2" DCW TO EMERGENCY EYE WASH. CONNECT 1/2" RO TO ROFAUCET. LOOP RO MAIN AS INDICATED AND PROVIDE BALL VALVE & FLOW CONTROL VALVE IN 1/2" RO LINE TO FAUCET.COORDINATE EXACT CONNECTION REQUIREMENTS WITH CASEWORK MANUFACTURER.
9 CONNECT TO EXISTING ACID WASTE RISER BELOW FLOOR.
SCALE: 1/4" = 1'-0"
FLOOR PLAN - PLUMBING DEMOLITION
NORTHSCALE: 1/4" = 1'-0"
FLOOR PLAN - PLUMBING
NORTH
GENERAL NOTE
A ALL FAUCETS, EYEWASH, LAB BENCHES AND FUME HOOD TRIM AREPROVIDED BY THE LAB EQUIPMENT SUPPLIER.
THE ENTIRE BUILDING IS PROTECTED WITHAN AUTOMATIC SPRINKLER SYSTEM.
MODIFY EXISTING SYSTEM, AS REQUIRED,TO PROTECT RENOVATED AREAS. ALL
MODIFICATIONS SHALL BE IN ACCORDANCEWITH ALL APPLICABLE LOCAL, STATE, AND
NFPA REGULATIONS. REFER TO DIV. 21.
BRANCH CIRCUIT AND SERVICE CONDUCTOR SIZING SCHEDULE
12
EQUIPMENTGROUNDING
CONDUCTOR(S)(AWG/kcmil)
F20
BRANCH CIRCUIT/FEEDERIDENTIFICATION
OVERCURRENTDEVICE
20
PHASE AND NEUTRALCONDUCTORS
(AWG/kcmil)
1/2"12
CONDUIT
10F25 25 10
10F30 30
8F35 35
8F40 40
1/2"
1/2"
1"
1"
8F45 45 1"
8F50 50
6F60 60
4F70 70
4F80 80
1"
1"
1-1/4"
1-1/4"
2F90 90 1-1/4"
10
10
10
10
10
10
8
8
8
2F100 100 1-1/4"8
1/0F125 125 2"6
1/0F150 150 2"6
2/0F175 175 2"6
3/0F200 200 2"6
4/0F225 225 2-1/2"4
250 kcmilF250 250 2-1/2"4
350 kcmilF300 300 3"4
500 kcmilF350 350 4"2
(2) 3/0F400 400 (2) 2-1/2"(2) 2
(2) 4/0F450 450 (2) 2-1/2"(2) 2
(2) 250 kcmilF500 500 (2) 2-1/2"(2) 2
(2) 350 kcmilF600 600 (2) 3"(2) 1/0
(2) 500 kcmilF700 700 (2) 4"(2) 1/0
(3) 300 kcmilF800 800 (3) 3"(3) 1/0
(3) 400 kcmilF1000 1000 (3) 3"(3) 2/0
(4) 350 kcmilF1200 1200 (4) 3"(4) 3/0
(5) 400 kcmilF1600 1600 (5) 3"(5) 4/0
(6) 400 kcmilF2000 2000 (6) 3"(6) 250 kcmil
(7) 500 kcmilF2500 2500 (7) 4"(7) 350 kcmil
(8) 500 kcmilF3000 3000 (8) 4"(8) 400 kcmil
(11) 500 kcmilF4000 4000 (11) 4"(11) 500 kcmil
NOTES:
1. WHERE BRANCH CIRCUIT OR FEEDER IS NOT DESIGNATED ON THE DRAWINGS, BRANCH CIRCUITOR FEEDER SHALL BE SIZED TO MATCH THE OVERCURRENT DEVICE LISTED ABOVE.
2. GROUNDING ELECTRODE CONDUCTORS FOR SEPARATELY DERIVED SYSTEMS SHALL BE SELECTEDBASED ON THE SECONDARY FEEDER OVERCURRENT DEVICE RATING.
GROUNDINGELECTRODECONDUCTOR(AWG/kcmil)
---
8
8
6
6
4
4
2
2
2
1/0
1/0
---
---
---
---
---
8
8
8
8
1/0
1/0
2/0
2/0
2/0
3/0
3/0
3/0
3/0
3/0
3/0
3/0
ELECTRICAL LEGEND
ALPA-1
ALPA-1
ALPA-1
ALPA-1
ALPA-1
A1LPA-1
ALPA-1
ALPA-1
E
SS
E
LPA-1
LPA-1
LPA-1
LPA-1
LPA-1,3
30A
LPA-1
LPA-1GFI
LPA-1
WP
LPA-1
EWC
LPA-1
LPA-1
LPA-1
E
E
LPA-1
LPA-12
2
2
2
E
C
WP
C
DF
DF
WP
C
C
WP
Z
X
X
E
DESCRIPTIONSYMBOL
LIGHTING FIXTURE - TYPE & CIRCUIT NOTED
LIGHTING
LIGHTING FIXTURE WITH BATTERY BACK-UP - TYPE & CIRCUIT NOTED
LIGHTING FIXTURE - TYPE & CIRCUIT NOTED
WALL WASHER - TYPE & CIRCUIT NOTED
WALL MOUNTED LIGHTING FIXTURE - TYPE & CIRCUIT NOTED
CEILING MOUNTED EXIT SIGN - TYPE NOTED - DIRECTIONAL ARROWS INDICATED
WALL MOUNTED EXIT SIGN - TYPE NOTED - DIRECTIONAL ARROWS INDICATED
EMERGENCY LIGHTING FIXTURE - TYPE & CIRCUIT NOTED
FLOOD LIGHT - TYPE & CIRCUIT NOTED
POLE MOUNTED LIGHTING FIXTURE - TYPE & CIRCUIT NOTED
GROUND MOUNTED BOLLARD LIGHT - TYPE & CIRCUIT NOTED
LIGHTING FIXTURE WITH BATTERY BACKUP - TYPE & CIRCUIT NOTED
EXISTING LIGHT FIXTURE TO REMAIN
EXISTING LIGHT FIXTURE TO BE REMOVED
EXISTING LIGHT FIXTURE TO REMAIN
EXISTING LIGHT FIXTURE TO BE REMOVED
EXISTING EXIT LIGHT FIXTURE TO REMAIN
EXISTING EXIT LIGHT FIXTURE TO BE REMOVED
JUNCTION BOX
PULLBOX
MOTOR LOCATION
LIGHTING CONTACTOR
DISCONNECT SWITCH - CIRCUIT NOTED
COMBINATION MOTOR STARTER/DISCONNECT SWITCH - CIRCUIT NOTED
TIMECLOCK
DESCRIPTIONSYMBOL
POWER
THERMOSTAT LOCATION
SURFACE MOUNTED LIGHTING AND APPLIANCE PANELBOARD
FLUSH MOUNTED LIGHTING AND APPLIANCE PANELBOARD
PUSHBUTTON
START/STOP PUSHBUTTON
EXISTING JUNCTION BOX TO REMAIN
EXISTING JUNCTION BOX TO BE REMOVED
SPST WALL SWITCH
3-WAY WALL SWITCH
4-WAY WALL SWITCH
SPST WALL SWITCH WITH PILOT LIGHT
KEY OPERATED SPST WALL SWITCH
WALL MOUNTED DIMMER SWITCH
WALL MOUNTED OCCUPANCY SENSOR - OPTIONS (M2) TWO POLE
DESCRIPTIONSYMBOL
WIRING DEVICES
WALL MOUNTED COMBINATION OCCUPANCY SENSOR/DIMMER
WALL MOUNTED VOLUME CONTROL SWITCH
CEILING MOUNTED OCCUPANCY SENSOR - OPTIONS (H) HIGH BAY
DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W, GROUNDING - CIRCUIT NOTED
DUPLEX RECEPTACLE ON EMERGENCY POWER
RECEPTACLE - 125/250V, 3P, 3W - AMP RATING AND CIRCUIT NOTED
DOUBLE DUPLEX RECEPTACLE - 20A, 125V, 2P, 3W, GROUNDING - CIRCUIT NOTED
DUPLEX RECEPTACLE WITH GFI - CIRCUIT NOTED
DUPLEX RECEPTACLE WITH WEATHER-PROOF COVER - CIRCUIT NOTED
DUPLEX RECEPTACLE WITH GFI SERVING ELECTRIC WATER COOLER - CIRCUIT NOTED
FLOOR MOUNTED DUPLEX RECEPTACLE - CIRCUIT NOTED
FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE - CIRCUIT NOTED
CEILING MOUNTED DUPLEX RECEPTACLE - CIRCUIT NOTED
OCCUPANCY SENSOR POWER PACK - OPTIONS (D) DIMMING, (E) UL 924 EMERGENCY
EXISTING DUPLEX RECEPTACLE TO REMAIN
EXISTING DUPLEX RECEPTACLE TO BE REMOVED
EXISTING DOUBLE DUPLEX RECEPTACLE TO REMAIN
EXISTING DOUBLE DUPLEX RECEPTACLE TO BE REMOVED
EXISTING SPST WALL SWITCH TO REMAIN
EXISTING SPST WALL SWITCH TO BE REMOVED
POWER/COMMUNICATIONS POLE - CIRCUIT NOTED
SURFACE MOUNTED RACEWAY - DEVICES INDICATED
DESCRIPTIONSYMBOL
COMMUNICATIONS
WALL MOUNTED TELEPHONE DEVICE - NO. OF OUTLETS INDICATED
FLOOR MOUNTED TELEPHONE DEVICE - NO. OF OUTLETS INDICATED
WALL MOUNTED DATA DEVICE - NO. OF OUTLETS INDICATED
FLOOR MOUNTED DATA DEVICE - NO. OF OUTLETS INDICATED
WALL MOUNTED COMMUNICATIONS DEVICE - TWO OUTLETS
FLOOR MOUNTED COMMUNICATIONS DEVICE - TWO OUTLETS
EXISTING COMMUNICATIONS DEVICE TO REMAIN
EXISTING COMMUNICATIONS DEVICE TO BE REMOVED
CEILING MOUNTED DATA DEVICE
CEILING MOUNTED SPEAKER
CEILING MOUNTED COAXIAL SPEAKER
WALL MOUNTED SPEAKER
WALL MOUNTED WEATHER PROOF SPEAKER
WALL MOUNTED MICROPHONE OUTLET
FLOOR MOUNTED MICROPHONE OUTLET
PUBLIC ADDRESS CALL-IN BUTTON
WALL MOUNTED VIDEO/TV OUTLET LOCATION
CEILING MOUNTED VIDEO/TV OUTLET LOCATION
FLOOR MOUNTED VIDEO/TV OUTLET LOCATION
CEILING MOUNTED CLOCK
WALL MOUNTED CLOCK
CEILING MOUNTED DUAL FACE CLOCK
WALL MOUNTED DUAL FACE CLOCK
WALL MOUNTED BELL
WEATHERPROOF WALL MOUNTED BELL
FIRE ALARM PULL STATION
FIRE ALARM AUDIBLE ALARM/VISUAL STROBE
FIRE ALARM VISUAL STROBE
FIRE ALARM SMOKE DETECTOR
FIRE ALARM HEAT DETECTOR
FIRE ALARM DUCT MOUNTED SMOKE DETECTOR IN SUPPLY AIR DUCT
FIRE ALARM DOOR HOLD OPEN DEVICE
FIRE ALARM SPRINKLER FLOW SWITCH
FIRE ALARM SPRINKLER TAMPER SWITCH
EXISTING FIRE ALARM PULL STATION
CEILING MOUNTED FIRE ALARM AUDIBLE ALARM/VISUAL STROBE
FIRE ALARM DUCT MOUNTED SMOKE DETECTOR IN RETURN AIR DUCT
EXISTING FIRE ALARM AUDIBLE ALARM/VISUAL STROBE
EXISTING FIRE ALARM VISUAL STROBE
EXISTING FIRE ALARM PULL STATION TO BE REMOVED
EXISTING FIRE ALARM AUDIBLE ALARM/VISUAL STROBE TO BE REMOVED
EXISTING FIRE ALARM VISUAL STROBE TO BE REMOVED
CEILING MOUNTED FIRE ALARM VISUAL STROBE
EXISTING FIRE ALARM SMOKE DETECTOR
EXISTING FIRE ALARM SMOKE DETECTOR TO BE REMOVED
FIRE ALARM SMOKE DAMPER LOCATION
FIRE ALARM SPEAKER/VISUAL STROBE
CARD READER
MOTION DETECTOR
DOOR LOCK
DOOR/WINDOW ALARM MONITOR
SECURITY KEY PAD
GLASS BREAK DETECTOR
SECURITY CAMERA
EXTERIOR SECURITY CAMERA AND ENCLOSURE
DESCRIPTIONSYMBOL
SECURITY
DESCRIPTIONSYMBOL
FIRE ALARM
DESCRIPTIONSYMBOL
NURSE CALL
NURSE CALL PATIENT STATION
NURSE CALL EMERGENCY STATION
NURSE CALL STAFF STATION
NURSE CALL MASTER CONTROL STATION
NURSE CALL CODE BLUE STATION
NURSE CALL DOME LIGHT
NURSE CALL ZONE DOME LIGHT
RECEPTACLE - 250V, 4P, 4W - AMP RATING AND CIRCUIT NOTED
WALL MOUNTED LOW VOLTAGE SWITCH - NO. OF BUTTONS / ZONES NOTED
ALPA-1
A1LPA-1
E
3
E
LPA-1,3,560A
J
P
T
T
FLOOR MOUNTED JUNCTION BOXJ
J
J
4
P
K
D
M
MD
V
L2
OSH
LPA-12
E
E
E
2
E
S
S
S
S
M
M
CB
V
V
V
C
C
C
C
B
B
F
F
F
S
F
F
S
H
S
R
SD
D
FS
TS
F
F
F
S
E
E
E
E
F
F
F
S
C
L
M
A
G
K
N
E
S
M
CB
D
D
OWNER FURNISHED CONTRACTOR INSTALLED
DIAMETER
DATA COLLECTION PANEL
DISTRIBUTION
DRAWINGS
DOWN
ELECTRIC DRINKING FOUNTAIN
EMPTY CONDUIT
EXHAUST FAN
EQUIPMENT
ELECTRIC WATER COOLER
EXHAUST
CENTRAL PROCESSING UNIT
CONDUCTOR
CIRCUIT
CLOSED CIRCUIT TELEVISION
CIRCUIT BREAKER
AMPERE(S)
ABOVE
ABOVE COUNTER
AIR CONDITIONING
AMPERE INTERRUPTING CAPACITY
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
AUTOMATIC TRANSFER SWITCH
AIR HANDLING UNIT
BELOW FINISHED FLOOR
BELOW FINISHED GRADE
BUILDING
CONDUIT
EXPLOSION PROOF
EXISTING
FIRE ALARM
FOOTCANDLES
FAN COIL UNIT
FLUORESCENT
FULL NEUTRAL
FEET, FOOT
GALVANIZED
GROUND FAULT CIRCUIT INTERRUPTER
GROUND FAULT INTERRUPTER
GROUND
GALVANIZED RIGID STEEL
HIGH INTENSITY DISCHARGE
HORSEPOWER
HAND OFF AUTOMATIC
HIGH PRESSURE SODIUM
HEATING/VENTILATING/AIR CONDITIONING
DIA
DCP
DIST
DWGS
DN
EDF
EC
EF
EQMT
EWC
EXH
CPU
COND
CKT
CCTV
CB
A
ABV
AC
A/C
AIC
AFF
AFG
ATS
AHU
BFF
BFG
BLDG
C
EXP
EXTG
F/A
FC
FCU
FLUOR
FN
FT
GALV
GFCI
GFI
GND
GRD
HID
HP
HOA
HPS
HVAC
HERTZHZ
MECHANICAL
MAIN DISTRIBUTION PANEL
MOUNTING HEIGHT
MAIN LUGS ONLY
MINIMUM
MERCURY VAPOR
MOUNTING
NON APPLICABLE
NORMALLY CLOSED
NON FUSED
NORMALLY OPEN
MOTOR CONTROL CENTER
MAXIMUM
MANHOLE
LOW PRESSURE SODIUM
POUND
INTERCOM
INSIDE DIAMETER
INTERMEDIATE STEEL CONDUIT
INCHES
INCANDESCENT
ISOLATED GROUND
JUNCTION BOX
KILOVOLT AMPERE
KILOVOLT
KILOVOLT AMPERE CAPACITIVE
KILOVOLT AMPERE REACTIVE
KILOWATT
KILOWATT HOUR
NIGHT LIGHT
ON CENTER
OVERHEAD
POLE
PUBLIC ADDRESS
PUSHBUTTON
PRIVATE BUILDING EXCHANGE
PULL CHAIN
PHOTOCELL
POWER DISTRIBUTION PANEL
PANELBOARD
POUNDS PER SQUARE INCH
POWER
SECURITY
SOLID NEUTRAL
MECH
MDP
MH
MLO
MIN
MV
MTG
NA
NC
NF
NO
MCC
MAX
M
LPS
LB
IC
ID
IMC
IN
INC
IG
JB
KVA
KV
KVAC
KVAR
KW
KWH
NL
OC
OFCI
OH
P
PA
PB
PBX
PC
P/C
PDP
PNL
PSI
PWR
S
SN
SQUARE FOOTSQFT
SWITCHSW
SWITCHBOARDSWBD
TIME CLOCKTC
TELEPHONETELE
THERMOSTATTSTAT
TELEVISIONTV
UNIT HEATERUH
UNLESS OTHERWISE NOTEDUON
UNDERGROUND PRIMARY ELECTRICUPE
VOLT(S)V
VAPOR PROOFVP
WIREW
WEATHERPROOFWP
TRANSFORMERXFMR
TRANSPONDERXPD
IMPEDANCEZ
ONE POLE1P
TWO POLE2P
THREE POLE3P
PHASEØ
WIRELESS ACCESS POINTWAP
ABBREVIATION DESCRIPTION
ELECTRICAL ABBREVIATIONS
ABBREVIATION DESCRIPTION
PPDE
CEILING MOUNTED DAY LIGHTING SENSORDS
INTERCOM STATIONIC
AGNEW ASSOCIATES, INC.MECHANICAL & ELECTRICAL CONSULTING ENGINEERSLUBBOCK, TEXAS TEXAS REGISTERED ENGINEERING FIRM F-1005 AUSTIN, TEXAS
PHONE: (806) 799-0753 AAI PROJECT NO. PHONE: (512) 828-0753
FAX: (806) 799-2014 WWW.AGNEWASSOCIATES.COM FAX: (512) 310-0750
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texaskerrville, texas
432-362-6565888-774-6565
www.jsarch.com
8/9/
2016
4:3
1:00
PM
C:\U
sers
\rees
e.AG
NEW
ASSO
CIAT
ES\D
ocum
ents
\201
6 Re
vit F
iles\
1216
011
MEP
Cen
tral
File
R16
_ree
se.rv
t
E0.1
ELECTRICALLEGEND &
SCHEDULES
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
1216011
REESE WRIGHT
79805
STA
ETOF TE
AX
S
PR
O
FESS IONAL ENG
INE
ER
R
EG I S TERED
8/8/168/8/168/8/168/8/16
A PROVIDE ALL MATERIALS, LABOR, AND EQUIPMENT AS REQUIRED TO INSTALL COMPLETE AND OPERABLE SYSTEMS ASINDICATED ON THE DRAWINGS, AS SPECIFIED, AS REQUIRED BY ALL APPLICABLE CODES, AND PER MANUFACTURER'SDIRECTIONS.
B NO CUTTING SHALL BE DONE TO ANY OF THE STRUCTURAL MEMBERS THAT WOULD TEND TO LESSEN THEIR STRENGTH,UNLESS SPECIFIC PERMISSION IS GRANTED BY THE ARCHITECT.
C SIZE AND LOCATION OF EXISTING EQUIPMENT, CONDUIT, WIRING, ETC. SHOWN FOR REFERENCE ONLY. FIELD VERIFY EXACTCONDITIONS PRIOR TO BID.
D REMOVE SLEEVES AND PATCH ALL WALLS, FLOORS, AND CEILINGS TO REMAIN WHERE CONDUIT AND/OR ELECTRICALEQUIPMENT HAS BEEN REMOVED. PATCHES IN RATED CONSTRUCTION SHALL MATCH EXISTING MATERIAL TO ENSURERATING INTEGRITY.
E COORDINATE DEMOLITION WITH GENERAL CONTRACTOR. OWNER SHALL HAVE FIRST RIGHTS TO ALL REMOVEDCOMPONENTS. THE REMAINING ITEMS SHALL BE COMPLETELY REMOVED BACK TO ACTIVE SERVICE LOCATION. REMOVE ALLASSOCIATED HANGERS, SUPPORTS, POWER, CONTROLS, ETC.
F PROVIDE SMOOTH CONCRETE FILL AND PATCH FOR ALL FLOOR MOUNTED OUTLETS BOXES AND FLOOR CHASES NOT BEINGREUSED FOR NEW CONSTRUCTION IS COMPLETE.
G COORDINATE CONSTRUCTION OF ALL WORK WITH ARCHITECTURAL, CIVIL, STRUCTURAL, PLUMBING, ELECTRICAL WORK,ETC., SHOWN ON ALL OTHER CONTRACT DOCUMENT DRAWINGS.
H ALL OPENINGS IN FIRE WALLS FOR BOXES, CONDUITS, ETC., SHALL BE FIRE STOPPED WITH A SPECIFIED PRODUCT SIMILARTO 3M, OR APPROVED EQUAL.
I PROVIDE UPDATED CIRCUIT DIRECTORIES FOR ALL EXISTING PANELBOARDS WHERE NEW CIRCUITS ARE ADDED OREXISTING CIRCUITS ARE DEMOLISHED.
J ALL CONDUCTORS SHALL BE INSTALLED IN RIGID METAL RACEWAY AS DESCRIBED IN THE SPECIFICATIONS. METAL CLAD,TYPE MC CABLE IS NOT AN ACCEPTABLE WIRING METHOD.
K PROVIDE DEDICATED NEUTRAL CONDUCTORS FOR ALL CIRCUITS REQUIRING A NEUTRAL CONNECTION. SHARING NEUTRALCONDUCTORS BETWEEN PHASES IS PROHIBITED.
L ALL OUTLET, DEVICE AND JUNCTION BOXES AND ASSOCIATED CONDUIT INDICATED IN NEW BLOCK WALLS SHALL BECONCEALED IN THE BLOCK WALL. SURFACE MOUNTED BOXES AND CONDUIT ARE NOT ACCEPTABLE AND WILL BE NOTEDFOR CORRECTION ON SITE INSPECTION PUNCH LISTS.
M FASTEN JUNCTION AND PULL BOXES TO OR SUPPORT FROM BUILDING STRUCTURE. DO NOT SUPPORT BOXES BY CONDUITS.
ELECTRICAL GENERAL NOTES
1 OR 2 GANG "BACK TO BACK" BOX DETAILNO SCALE
DRYWALL
DEVICE COVER(1 OR 2 GANGAS REQ'D.)
BOX SUPPORT -CADDY OR EQUAL
4" X 4" OUTLET BOX
CENTERLINEOF DEVICE
WALL STUD
90 DEGREE CONNECTOR
EMTCONDUIT
J-BOX ATTACHED TOSTRUCTURE ABOVE
FLEX CONDUIT 6' MAXIMUM
CEILING TEE BAR
LIGHT FIXTURE
TEE BAR CLIP (4 PER FIXTURE)
TEE BAR LEFT OUT FOR CLARITY
LAY-IN LIGHT FIXTURE DETAILNO SCALE
DEDICATED LIGHT FIXTURE WHIP SUPPORTCABLE. CABLE SHALL BE ATTACHED TO
STRUCTURE ABOVE AND TO CEILING TEEBAR. THIS CABLE MAY NOT BE USED TO
SUPPORT CEILING ASSEMBLY.
CEILING ASSEMBLY SUPPORTCABLES. CABLES MAY NOT BEUSED TO SUPPORT LIGHTFIXTURE WHIP.
CONDUIT CLIP ATTACHED TOSUPPORT CABLE TO SECURE
LIGHT FIXTURE WHIP.PAINT CLIP YELLOW.
MULTIPLE OUTLET BOX DETAILNO SCALE
NOTE: TYPICAL FOR OUTLET BOXES
DEVICE COVERS AS REQ'D
4 x 4 OUTLET BOXESAS REQUIRED
BOX SUPPORT CADDY OR EQUAL
CENTERLINE OF DEVICE
WALL STUD
PANELBOARD IDENTIFICATION DETAILNO SCALE
NOTE: PROVIDE LABELING FOR NEW AND EXISTINGPANELBOARDS.
PANEL NAME
PHENOLIC NAMEPLATE WITH 1/4" LETTERSINSCRIBED AS INDICATED. PROVIDE WHITELABELS WITH BLACK LETTERS FOR NORMALSYSTEM PANELS AND RED LABELS WITH WHITELETTERS FOR ESSENTIAL SYSTEM PANELS.
WARNING:WARNING: POTENTIAL ARC FLASH HAZARD.APPROPRIATE PPE AND TOOLS
REQUIRED WHEN WORKINGON THIS EQUIPMENT.
PANEL "DPB"480/277 VOLTS 3 PHASENORMAL BRANCHFED BY SWITCHBOARD 'SBA'
PANEL VOLTAGE AND PHASE
POWER SYSTEM (HOSPITAL ONLY):NORMAL BRANCHCRITICAL BRANCH
LIFE SAFETY BRANCHEQUIPMENT BRANCH
SOURCE OF POWER TO PANEL
WIRE COLOR CODES:PHASE A - NEUTRAL -PHASE B - GROUND -PHASE C -
A LEGEND OF THE WIRE COLOR CODES SHALL BEINSTALLED ON THE COVER OF EACHPANELBOARD. COLOR CODES SHALL COMPLYWITH NEC.
WIRING DEVICE MOUNTING HEIGHTS - TYPICALNO SCALE
NOTE: VERIFY ALL HEIGHTS WITH ARCHITECT
FINISHED CEILING
CLOCK HANGER OUTLET
DIMMER SWITCH
WALL SWITCH
TELEPHONEOUTLET RECEPTACLE
THERMOSTATFIRE ALARM PULLSTATION
FIRE ALARM HORN/LIGHT
DATA TERMINALOUTLET
FINISHED FLOOR
LOWEST OF6" BELOWFINISHEDCEILING OR90" AFF
1'-0" BELOW FINISHEDCEILING. (MOUNT 8'-0" AFFFOR NO CEILING ORSLOPED CEILINGCONDITION)
1'-6
"A
FF
4'-0
"A
FF
BONDING JUMPER - SAME SIZE AS EQUIPMENTGROUNDING CONDUCTOR
PANELBOARD EQUIPMENT GROUNDBUS BONDED TO CABINET
EQUIPMENT GROUNDING CONDUCTORINSTALLED WITH FEEDER
FEEDER CONDUITLOCKNUT (NOT SHOWN)
INSULATED THROAT GROUNDINGBUSHING
PANELBOARD BONDING DETAILNO SCALE
AGNEW ASSOCIATES, INC.MECHANICAL & ELECTRICAL CONSULTING ENGINEERSLUBBOCK, TEXAS TEXAS REGISTERED ENGINEERING FIRM F-1005 AUSTIN, TEXAS
PHONE: (806) 799-0753 AAI PROJECT NO. PHONE: (512) 828-0753
FAX: (806) 799-2014 WWW.AGNEWASSOCIATES.COM FAX: (512) 310-0750
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texaskerrville, texas
432-362-6565888-774-6565
www.jsarch.com
8/9/
2016
4:3
1:02
PM
C:\U
sers
\rees
e.AG
NEW
ASSO
CIAT
ES\D
ocum
ents
\201
6 Re
vit F
iles\
1216
011
MEP
Cen
tral
File
R16
_ree
se.rv
t
E0.2
ELECTRICALDETAILS
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
1216011
REESE WRIGHT
79805
STA
ETOF TE
AX
S
PR
O
FESS IONAL ENGIN
EE
R
R
EG I S TERED
8/8/168/8/168/8/168/8/16
TYPE VOLTAGE MOUNTING MANUFACTURER MODEL NO. LAMPSDELIVERED
LUMENS INPUT WATTS NOTES
A 120/277 RECESSED METALUX 24GRRA-LD4-64-A125-UNV-L835-CD1-PAF LED 6400 60 VA
A1 120/277 RECESSED METALUX 24GRRA-LD4-64-A125-UNV-GTD2-L835-CD1-PAF LED 6400 60 VA 1
B 120/277 RECESSED METALUX 24GRRA-LD4-48-A125-UNV-L835-CD1-PAF LED 4800 43 VA
B1 120/277 RECESSED METALUX 24GRRA-LD4-48-A125-UNV-GTD2-L835-CD1-PAF LED 4800 43 VA 1
LIGHT FIXTURE SCHEDULE
1 PROVIDE FIXTURE WITH BODINE GTD2 UL 924 TRANSFER RELAY.
LIGHT FIXTURE NOTES
A PROVIDE ALL LENSED FIXTURES WITH KSH-12 (.125") LENSES, REGRESSED WHITE ALUMINUM DOORS, SPRING LOADED CAM LATCHES AND POST-PAINTEDASSEMBLY UNLESS NOTED OTHERWISE.
B EACH LIGHT FIXTURE TYPE SHALL BE BINNED WITHIN A THREE-STEP MACADAM ELLIPSE TO ENSURE COLOR CONSISTENCY AMONG LUMINAIRES.
LIGHT FIXTURE GENERAL NOTES
Notes:
Total Est. Demand: 27 A
Total Conn.: 36 A
Total Est. Demand: 9900 VA
RECEPTACLE 9200 VA 100.00% 9200 VA Total Conn. Load: 9900 VA
POWER 700 VA 100.00% 700 VA
Load Classification Connected Load Demand Factor Estimated Demand Panel Totals
Legend:
Total Amps: 36 A 26 A 22 A
Total Load: 4200 VA 3100 VA 2600 VA
35 SPACE ONLY -- -- -- 0 0 -- -- -- SPACE ONLY 36
33 SPACE ONLY -- -- -- 0 0 -- -- -- SPACE ONLY 34
31 SPACE ONLY -- -- -- 0 0 -- -- -- SPACE ONLY 32
29 SPARE 20 A 1 0 0 1 20 A SPARE 30
27 SPARE 20 A 1 0 0 1 20 A SPARE 28
25 SPARE 20 A 1 0 0 1 20 A SPARE 26
23 SPARE 20 A 1 0 0 1 20 A SPARE 24
21 SPARE 20 A 1 0 0 1 20 A SPARE 22
19 SPARE 20 A 1 0 0 1 20 A SPARE 20
17 DOOR SECURITY 20 A 1 200 0 1 20 A SPARE 18
15 POWER LAB 2215B 20 A 1 500 0 1 20 A SPARE 16
13 RECEPTACLE LAB 2215B 20 A 1 600 600 1 20 A RECEPTACLE LAB 2215B 14
11 RECEPTACLE LAB 2215B 20 A 1 400 400 1 20 A RECEPTACLE LAB 2215B 12
9 RECEPTACLE COMPUTER 2215 20 A 1 600 400 1 20 A RECEPTACLE LAB 2215B 10
7 RECEPTACLE COMPUTER 2215 20 A 1 800 800 1 20 A RECEPTACLE COMPUTER 2215 8
5 RECEPTACLE COMPUTER 2215 20 A 1 800 800 1 20 A RECEPTACLE COMPUTER 2215 6
3 RECEPTACLE ROOMS 2215A, 2215 20 A 1 800 800 1 20 A RECEPTACLE COMPUTER 2215 4
1 RECEPTACLE COMPUTER 2215 20 A 1 600 800 1 20 A RECEPTACLE LAB 2215B 2
CKT Circuit Description Trip Poles Notes
A B C A B C
Notes Poles Trip Circuit Description CKT
Notes:
Enclosure: Type 1
Mounting: Recessed Wires: 4 Mains Rating: 100 A
Supply From: 2DPB Phases: 3 Mains Type: MLO
Volts: 120/208 Wye A.I.C. Rating: 10000
PANEL: "2LM"
1
1
2LA
4#3#8GND1 1/4"C
2LB1
400A,208Y/120V,3PH,4W,10,000 AIC
100A 3P
400A3PLSI
2DPB-SECTION 1
100A 3P
200% NEUTRAL BUS
SAFETY GROUND BUS
100A 3P
2LDGENERALBIOLOGYTEACHINGLAB
100A 3P
2LEBIOLOGYTEACHINGLABRM 2214
100A 3P 100A 3P
4#3#8GND1 1/4"C
4#3#8GND1 1/4"C
4#3#8GND1 1/4"C
4#3#8GND1 1/4"C
2LGMICROBIOLOGYLABRM2229
100A 3P
2LHCELLBIOLOGYRM 2224
100A 3P
2LJMICROBIOLOGYLAB
100A 3P
4#3#8GND1 1/4"C
4#3#8GND1 1/4"C
2LKGENERALRESEARCH LABRM 2221
4#3#8GND1 1/4"C
2LLGENERALRESEARCH LABRM 2219(ALTERNATE #3)
400A,208Y/120V,3PH,4W,10,000 AIC
100A 3P
2DPB-SECTION 2
100A 3P
200% NEUTRAL BUS
SAFETY GROUND BUS
NEW PANEL "2LM"
100A 3P
2LNGENERALRESEARCH LABRM 2213
100A 3P
2LOCHEMICALLAB SCIENCERM 2207
100A 3P
FEEDTHRULUGS
3-100A/3PEQUIPPEDSPACES
2LFBIOLOGYTEACHINGLABRM 2216
2LPBIOLOGYTEACHINGLABRM 2205
100A 3P
4#3#8GND1 1/4"C
2LCANATOMYTEACHINGLABRM 2206(ALTERNATE #3)
2LB2
100A 3P
4#3#8GND1 1/4"C
2LRBIOLOGYPREPRM2202
100A 3P
4#3#8GND1 1/4"C
2LB3
100A 3P
4#3#8GND1 1/4"C
4#3#8GND1 1/4"C
4#3#8GND1 1/4"C
4#3#8GND1 1/4"C
4#3#8GND1 1/4"C
2-2 1/2"CEA/W3#4/02#4/0 NEUT#1/0GND
4#3#8GND1 1/4"C
EXISTING ONE-LINE DIAGRAMNO SCALE
1
3
2
AGNEW ASSOCIATES, INC.MECHANICAL & ELECTRICAL CONSULTING ENGINEERSLUBBOCK, TEXAS TEXAS REGISTERED ENGINEERING FIRM F-1005 AUSTIN, TEXAS
PHONE: (806) 799-0753 AAI PROJECT NO. PHONE: (512) 828-0753
FAX: (806) 799-2014 WWW.AGNEWASSOCIATES.COM FAX: (512) 310-0750
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texaskerrville, texas
432-362-6565888-774-6565
www.jsarch.com
8/9/
2016
4:3
1:03
PM
C:\U
sers
\rees
e.AG
NEW
ASSO
CIAT
ES\D
ocum
ents
\201
6 Re
vit F
iles\
1216
011
MEP
Cen
tral
File
R16
_ree
se.rv
t
E0.3
ELECTRICAL RISERDIAGRAM
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
1216011
A VERIFY THE EXACT LOCATION OF ALL ELECTRICAL EQUIPMENT AT THE SITE.
B VERIFY ALL POWER COMPANY REQUIREMENTS WITH THE POWER COMPANY PRIOR TO BID. INCLUDE ALL POWERCOMPANY SERVICES COSTS IN THE ELECTRICAL BID NUMBER.
C VERIFY ALL ELECTRICAL SERVICE METERING REQUIREMENTS WITH THE POWER COMPANY. PROVIDE ALL LABOR ANDMATERIALS NECESSARY TO PROVIDE THE METERING CONNECTIONS REQUIRED BY THE POWER COMPANY.
D WHERE FEEDER SIZES ARE NOT INDICATED, FEEDER SHALL MATCH THE ASSOCIATED OVERCURRENT PROTECTIVE DEVICEAS INDICATED ON THE BRANCH CIRCUIT AND SERVICE CONDUCTOR SIZING SCHEDULE.
GENERAL NOTES
NOTES INDICATED BY " "
REESE WRIGHT
79805
STA
ETOF TE
AX
S
PR
O
FESS IONAL ENGIN
EE
R
R
EG I S TERED
8/8/168/8/168/8/168/8/16
1 EXISTING 100A-3P CIRCUIT BREAKER IN EXISTING PANEL “2DPB”. USE CIRCUIT BREAKER TO SERVE NEW PANEL “2LM”.
2 EXISTING 1-1/4” CONDUIT. INSTALL 4 #3 & #8 GROUND IN EXISTING CONDUIT TO NEW PANEL “2LM”.
3 EXISTING JUNCTION BOX IN PROJECT AREA. EXTEND 1-1/4” CONDUIT AND 4 #3 & #8 GROUND FROM JUNCTION BOX TO PANEL“2LM”. VERIFY EXACT LOCATION AND CONDITIONS AT JOBSITE.
F
S S
4
2
3
1
4 4
55
T
WAP
4
4
5
5
5 5
5
5
AGNEW ASSOCIATES, INC.MECHANICAL & ELECTRICAL CONSULTING ENGINEERSLUBBOCK, TEXAS TEXAS REGISTERED ENGINEERING FIRM F-1005 AUSTIN, TEXAS
PHONE: (806) 799-0753 AAI PROJECT NO. PHONE: (512) 828-0753
FAX: (806) 799-2014 WWW.AGNEWASSOCIATES.COM FAX: (512) 310-0750
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texaskerrville, texas
432-362-6565888-774-6565
www.jsarch.com
8/9/
2016
4:3
1:04
PM
C:\U
sers
\rees
e.AG
NEW
ASSO
CIAT
ES\D
ocum
ents
\201
6 Re
vit F
iles\
1216
011
MEP
Cen
tral
File
R16
_ree
se.rv
t
E1.1
FLOOR PLAN -ELECTRICALDEMOLITION
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
1216011
GENERAL NOTES
NOTES INDICATED BY " "
REESE WRIGHT
79805
STA
ETOF TE
AX
S
PRO
FESS IONAL ENGIN
EE
R
R
EG I S TERED
8/8/168/8/168/8/168/8/16
1 REMOVE ALL ELECTRICAL ITEMS IN THIS AREA INCLUDING LIGHTING FIXTURES, RECEPTACLES, TRANSFORMERS,EQUIPMENT PANELS, WIRING AND ASSOCIATED CONDUIT BACK TO SOURCE UNLESS NOTED OTHERWISE. CONTRACTORSHALL BE RESPONSIBLE FOR SITE VERIFICATION PRIOR TO BID. ELECTRICAL ITEMS FEEDING ADJACENT SPACES SHALLREMAIN AND BE PROTECTED DURING DEMOLITION.
2 EXISTING TIMER SWITCH TO BE REMOVED.
3 EXISTING WIRELESS ACCESS POINT TO REMAIN AS EXISTING.
4 EXISTING FIRE ALARM DEVICE TO REMAIN AS EXISTING.
5 EXISTING TERMINATED DATA OUTLET TO BE REMOVED.
6 EXISTING SMOKE DETECTOR TO BE RELOCATED INTO NEW CEILING.
A VERIFY EXACT DEMOLITION WITH ARCHITECTURAL DEMOLITION PLAN.
B VERIFY EXACT SALVAGE REQUIREMENTS WITH OWNER AND/OR ARCHITECT BEFORE DEMOLITION BEGINS.
C PROVIDE SMOOTH CONCRETE FILL AND PATCH FOR ALL FLOOR MOUNTED OUTLETS BOXES AND FLOOR CHASES NOTBEING REUSED FOR NEW CONSTRUCTION IS COMPLETE.
D REMOVE ALL ELECTRICAL DEVICES IN WALLS TO BE REMOVED DURING CONSTRUCTION.
E REMOVE ALL ELECTRICAL DEVICES INTERFERING WITH NEW WALL CONSTRUCTION.
F REMOVE AND RECONNECT ANY ELECTRICAL DEVICES INTERFERING WITH CONSTRUCTION BUT REUSED AFTERCONSTRUCTION.
SCALE: 1/4" = 1'-0"
FLOOR PLAN - ELECTRICAL DEMOLITION
NORTH
OSPPD
OS
OS PPD
OS
COMPUTER
2215
STORAGE
2215A
LAB
2215B
A A1
B1 B
A1
AAAA
A1
A
A A A A A1
M
E E
2EHA-3 2HA-3
2HA-3 2HA-3 2HA-3 2HA-3
2HA-3
2HA-3
2HA-3 2HA-3 2HA-3 2HA-3
2HA-3 2HA-3
2HA-3 2HA-3
2HA-3
2EHA-3
2EHA-3
2EHA-3
2EHA-3
2EHA-3
2HA-3
D
D
3
12
3
3
3
3
AGNEW ASSOCIATES, INC.MECHANICAL & ELECTRICAL CONSULTING ENGINEERSLUBBOCK, TEXAS TEXAS REGISTERED ENGINEERING FIRM F-1005 AUSTIN, TEXAS
PHONE: (806) 799-0753 AAI PROJECT NO. PHONE: (512) 828-0753
FAX: (806) 799-2014 WWW.AGNEWASSOCIATES.COM FAX: (512) 310-0750
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texaskerrville, texas
432-362-6565888-774-6565
www.jsarch.com
8/9/
2016
4:3
1:05
PM
C:\U
sers
\rees
e.AG
NEW
ASSO
CIAT
ES\D
ocum
ents
\201
6 Re
vit F
iles\
1216
011
MEP
Cen
tral
File
R16
_ree
se.rv
t
E2.1
FLOOR PLAN -LIGHTING
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
1216011
GENERAL NOTES
NOTES INDICATED BY " "
REESE WRIGHT
79805
STA
ETOF TE
AX
S
PR
O
FESS IONAL ENGIN
EE
R
R
EG I S TERED
8/8/168/8/168/8/168/8/16
A VERIFY THE EXACT LOCATION OF ALL LIGHT FIXTURES WITH THE ARCHITECTURAL REFLECTED CEILING PLAN.
B INSTALL A CONTINUOUS, NON-SWITCHED HOT CONNECTION TO ALL NEW EMERGENCY DRIVERS AND EXIT SIGNS.
C VERIFY THE EXACT MOUNTING HEIGHT OF ALL WALL MOUNTED LIGHT FIXTURES WITH THE ARCHITECTURAL ELEVATIONS.
D ALL OCCUPANCY SENSORS, WITH THE EXCEPTION OF THE FOLLOWING LOCATIONS, SHALL BE SET TO VACANCY MODE FORMANUAL ON-AUTOMATIC OFF: CORRIDORS, STAIRS, RESTROOMS, BUILDING PRIMARY ENTRANCES, LOBBIES AND OTHERAREAS AS INDICATED ON THE PLAN.
1 EXISTING LIGHT FIXTURE CONNECTED TO NORMAL BRANCH CIRCUIT “2HA-3” TO REMAIN.
2 EXISTING LIGHT FIXTURE CONNECTED TO EMERGENCY LIGHTING CIRCUIT “2EHA-3” TO REMAIN.
3 CONNECT BOTH NORMAL AND EMERGENCY CIRCUITS TO UL 924 TRANSFER RELAY PROVIDED WITH FIXTURE.
SCALE: 1/4" = 1'-0"
FLOOR PLAN - LIGHTING
NORTH
J
J
J J
J
J
J
J
J96" 96"
96"
90" 90" 90"
1
GFI
STORAGE
2215A
COMPUTER
2215
LAB
2215B
WAP
3
96"5
96"
5
4 4 4
96"
5
2LM
2 2 2 2
6
2LM 1
2LM 1
2LM 1
2LM 2
2LM 2
2LM 2
2LM 2 2LM 15 2LM 14
2LM 14
2LM 14
2LM 13
2LM 62LM 6
2LM 132LM 10 2LM 10 2LM 11 2LM 11 2LM 12 2LM 12
2LM 92LM 92LM 9
2LM 8 2LM 8 2LM 7 2LM 7
2LM 6
2LM 52LM 52LM 32LM 4 2LM 4
2LM 3
2LM 3
2LM 3
2LM 6
7
2LM 17
2LM 17
6
2LM 13
9
COMPUTER
2215
STORAGE
2215A
LAB
2215B
2DPB
2LM
8
AGNEW ASSOCIATES, INC.MECHANICAL & ELECTRICAL CONSULTING ENGINEERSLUBBOCK, TEXAS TEXAS REGISTERED ENGINEERING FIRM F-1005 AUSTIN, TEXAS
PHONE: (806) 799-0753 AAI PROJECT NO. PHONE: (512) 828-0753
FAX: (806) 799-2014 WWW.AGNEWASSOCIATES.COM FAX: (512) 310-0750
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texaskerrville, texas
432-362-6565888-774-6565
www.jsarch.com
8/9/
2016
4:3
1:06
PM
C:\U
sers
\rees
e.AG
NEW
ASSO
CIAT
ES\D
ocum
ents
\201
6 Re
vit F
iles\
1216
011
MEP
Cen
tral
File
R16
_ree
se.rv
t
E3.1
FLOOR PLAN -POWER &
COMMUNICATIONS
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
1216011
GENERAL NOTES
NOTES INDICATED BY " "
REESE WRIGHT
79805
STA
ETOF TE
AX
S
PRO
FESS IONAL ENGIN
EE
R
R
EG I S TERED
8/8/168/8/168/8/168/8/16
A PROVIDE 3/4" CONDUIT TO 6" ABOVE CEILING OR TO THE STRUCTURE IN OPEN CEILING AREAS AT EACH COMMUNICATIONSDEVICE INDICATED. INSTALL CATEGORY 6 COMMUNICATIONS WIRING FROM EACH OUTLET TO NEW PATCH PANEL IN EXISTINGIDF RACK. REFER TO THE DIVISION 27 SPECIFICATIONS FOR ALL REQUIREMENTS.
B VERIFY ALL DEVICE MOUNTING HEIGHTS FOR DEVICES LOCATED IN MILLWORK WITH ARCHITECTURAL ELEVATIONS. FOR ALLDEVICES NOT INDICATED ON THE ARCHITECTURAL ELEVATIONS, VERIFY THE EXACT LOCATION AND MOUNTING HEIGHT WITHTHE ARCHITECT PRIOR TO INSTALLATION.
C VERIFY THE EXACT LOCATION OF ALL FLOOR MOUNTED DEVICES WITH THE ARCHITECT AND/OR OWNER PRIOR TO ROUGH-ININSTALLATION.
D THE WORK INDICATED ON THIS SHEET IS ONLY A PORTION OF THE COMPLETE WORK TO BE COMPLETED BY THE DIVISION 16CONTRACTOR. REFER TO THE AUDIO VISUAL DRAWINGS FOR ADDITIONAL WORK REQUIRED. VERIFY THE EXACT LOCATION,MOUNTING HEIGHTS AND CONNECTION REQUIREMENTS OF ALL AUDIO VISUAL EQUIPMENT WITH THE AUDIO VISUALDRAWINGS. PROVIDE ALL CONNECTIONS REQUIRED FOR COMPLETE OPERATION OF AUDIO VISUAL PRESENTATION SYSTEM.
1 J-BOX TO SERVE FUME HOOD.PROVIDE CONNECTIONS AS DIRECTED BY THE EQUIPMENT PROVIDER.
2 DUAL CHANNEL POWER/COMMUNICATIONS SERVICE POLE. VERIFY EXACT LOCATION AT JOBSITE. INSTALL QUADRAPLEXPOWER OUTLET AND COMMUNICATIONS OUTLET AS INDICATED.
3 NEW ELECTRICAL PANEL 2LM. REFER TO RISER DIAGRAM.
4 NEMA L14-20R RECEPTACLE MOUNTED AT 90” AFF. VERIFY EXACT LOCATION WITH THE OWNER.
5 RECEPTACLE AND J-BOX TO SERVE WALL MOUNTED MONITOR. VERIFY EXACT LOCATION AND HEIGHT WITH THEARCHITECT. PROVIDE 1” CONDUIT FROM J-BOX TO 6” ABOVE CEILING.
6 J-BOXES TO SERVE FUTURE CARD READER AND DOOR LOCK. VERIFY EXACT ROUGH-IN REQUIREMENTS AND LOCATIONSWITH THE OWNER.
7 APPROXIMATE LOCATION OF EXISTING IDF ROOM. INSTALL A NEW PATCH PANEL IN THE EXISTING DATA RACK TO SERVETHE COMMUNICATIONS OUTLETS INDICATED.
8 APPROXIMATE LOCATION OF EXISTING DISTRIBUTION PANEL IN EXISTING ELECTRICAL ROOM. REFER TO THE ELECTRICALRISER DIAGRAM. VERIFY EXACT LOCATION AND EXISTING CONDITIONS AT THE JOBSITE.
9 J-BOX TO SERVE TEACHING STATION COMMUNICATION WIRING. VERIFY EXACT LOCATION WITH THE OWNER. PROVIDE 1”CONDUIT TO 6” ABOVE THE CEILING.
SCALE: 1/4" = 1'-0"
FLOOR PLAN - POWER & COMMUNICATIONS
NORTH
SCALE: 1/16" = 1'-0"
OVERALL FLOOR PLAN - ELECTRICAL
NORTH
F
S S
F
F
F
F
S S
S
STORAGE
2215A
COMPUTER
2215
LAB
2215B
3 3
4
4
1
4
4
3
AGNEW ASSOCIATES, INC.MECHANICAL & ELECTRICAL CONSULTING ENGINEERSLUBBOCK, TEXAS TEXAS REGISTERED ENGINEERING FIRM F-1005 AUSTIN, TEXAS
PHONE: (806) 799-0753 AAI PROJECT NO. PHONE: (512) 828-0753
FAX: (806) 799-2014 WWW.AGNEWASSOCIATES.COM FAX: (512) 310-0750
Issue
/ R
evis
ion
s:
No.
Date
Descri
pti
on
jsa architectsodessa, texaskerrville, texas
432-362-6565888-774-6565
www.jsarch.com
8/9/
2016
4:3
1:07
PM
C:\U
sers
\rees
e.AG
NEW
ASSO
CIAT
ES\D
ocum
ents
\201
6 Re
vit F
iles\
1216
011
MEP
Cen
tral
File
R16
_ree
se.rv
t
E4.1
FLOOR PLAN - FIREALARM &
EQUIPMENT
JSA No: 2016-22
UN
IVER
SIT
Y T
EXA
S O
F TH
E P
ERM
IAN
BA
SIN
STC
Lab 2
21
6 F
inis
h O
ut
49
01
E.
Univ
ers
ity
Odessa,
Texas 7
97
62
108
-8-2
016
100%
CON
STRU
CTIO
N DO
CUM
ENTS
2 3 4 5 6
1216011
GENERAL NOTES
NOTES INDICATED BY " "
REESE WRIGHT
79805
STA
ETOF TE
AX
S
PRO
FESS IONAL ENGIN
EE
R
R
EG I S TERED
8/8/168/8/168/8/168/8/16
A PROVIDE A COMPLETE AND OPERATIONAL FIRE ALARM SYSTEM AS INDICATED ON THE DRAWINGS AND AS DETAILED INSECTION 16721 OF THE SPECIFICATIONS.
B PROVIDE ALL FIRE ALARM WIRING IN 3/4" CONDUIT. PROVIDE COMPLETE CONDUIT LAYOUT WITH FIRE ALARM SUBMITTAL.
C REFER TO MECHANICAL DRAWINGS FOR LOCATIONS OF ALL TEMPERATURE CONTROL DEVICES.
1 EXISTING FIRE ALARM DEVICE TO REMAIN.
2 EXISTING RELOCATED SMOKE DETECTORS. RE-INSTALL IN NEW CEILING AND RECONNECT AS EXISTING.
3 NEW SMOKE DETECTOR. INSTALL CONTROL WIRING IN 3/4” CONDUIT TO EXISTING AREA INITIATION CIRCUIT. PROVIDE ALLLABOR AND MATERIALS NECESSARY TO CONNECT THE NEW DEVICE FOR COMPLETE OPERATION.
4 NEW FIRE ALARM INDICATING DEVICE. PROVIDE CONTROL WIRING IN 3/4” CONDUIT TO EXISTING AREA INDICATING CIRCUIT.PROVIDE ALL LABOR AND MATERIALS NECESSARY TO CONNECT THE NEW DEVICE FOR COMPLETE OPERATION.
SCALE: 1/4" = 1'-0"
FLOOR PLAN - FIRE ALARM & EQUIPMENT
NORTH