![Page 1: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/1.jpg)
UniversityUniversity of Wisconsin – Madisonof Wisconsin – Madison
Engineering Projects In Community Service
BIOFEEDBACK / STRESS MANAGEMENT
May 9, 2001
Professor John Webster, AdvisorProfessor John Webster, AdvisorDepartment of Biomedical EngineeringDepartment of Biomedical Engineering
Dr. Dan Muller, ClientDr. Dan Muller, ClientDepartment of Medicine and Med Micro/ImmunologyDepartment of Medicine and Med Micro/Immunology
![Page 2: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/2.jpg)
Group MembersElectrodes:
Ben Birkenstock Ji ChoeElizabeth NeeChristy Palmer
Feedback:Chris KoenigsAmy Li
Electronics:Steve Almasi Jacob FealaWilliam LauSarah Michaels
![Page 3: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/3.jpg)
Problem Statement
To design and build a portable, inexpensive To design and build a portable, inexpensive electroencephalogram (EEG) device that electroencephalogram (EEG) device that would enable users to monitor brain states would enable users to monitor brain states during meditation.during meditation.
![Page 4: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/4.jpg)
Meditation
Self-induced calming of mind and bodySelf-induced calming of mind and body Linked to health benefitsLinked to health benefits
ADDADD Blood pressureBlood pressure CreativityCreativity
![Page 5: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/5.jpg)
Electroencephalogram (EEG)
Electrodes attached to Electrodes attached to scalpscalp
Action potentials of Action potentials of cells amplified and cells amplified and averagedaveraged
Oscilloscope provides Oscilloscope provides visual representation visual representation of brain wave signalsof brain wave signals
![Page 6: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/6.jpg)
Brain Wave States
Beta: waking activity Beta: waking activity (above 13 Hz)(above 13 Hz)
Alpha: relaxed, eyes Alpha: relaxed, eyes closed (8-13 Hz)closed (8-13 Hz)
Theta: drowsy, Theta: drowsy, dreamlike (4-7 Hz)dreamlike (4-7 Hz)
Delta: deep sleep Delta: deep sleep (below 4 Hz)(below 4 Hz)
Meditation can alter Meditation can alter brain waves over timebrain waves over time
![Page 7: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/7.jpg)
Subgroups
ElectrodesElectrodesDetermine number, type, placement and Determine number, type, placement and
attachment of electrodesattachment of electrodes ElectronicsElectronics
Design and build circuitryDesign and build circuitry FeedbackFeedback
Determine system of feedback to userDetermine system of feedback to user
![Page 8: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/8.jpg)
Basic Design Concept
![Page 9: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/9.jpg)
Electrodes
Elizabeth NeeElizabeth Nee
![Page 10: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/10.jpg)
Electrode Selection
StyleStyle ReusableReusable DisposableDisposable Dry/activeDry/active
Type of electrolyteType of electrolyte GelGel PastePaste SalineSaline HydrogelHydrogel
![Page 11: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/11.jpg)
Electrode Placementtheta—central
alpha—occipital
![Page 12: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/12.jpg)
Current Design ProsPros
InconspicuousInconspicuous Not distracting to userNot distracting to user AdjustableAdjustable Easy to place properlyEasy to place properly
ConsCons Possible noisePossible noise Problems Problems
achievingachieving good good contact through contact through long hairlong hair
side view
rear view
![Page 13: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/13.jpg)
Accomplishments This Semester
Research Research Full EEG electrode set-up not necessaryFull EEG electrode set-up not necessary Placement of electrodes confirmedPlacement of electrodes confirmed
Existing products Existing products Ordered FlexTrodes systemOrdered FlexTrodes system Investigated HydroDot electrodesInvestigated HydroDot electrodes
Tested deviceTested device
![Page 14: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/14.jpg)
Electronics
Steve AlmasiSteve Almasi
![Page 15: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/15.jpg)
General Specifications PortablePortable
SmallSmall LightweightLightweight Battery poweredBattery powered
Inexpensive Inexpensive Most existing products > $700Most existing products > $700
Measure strength of alpha (Measure strength of alpha (aa) and theta () and theta (JJ)) Provide feedbackProvide feedback
Dominant stateDominant state Strength of dominant stateStrength of dominant state
![Page 16: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/16.jpg)
Signal Flow Diagram
electrodes amplifier
filter
(4-8 Hz)
rectifier+
averager
audio output
filter
(8-13 Hz)
rectifier+
averager
voltage-controlled oscillator
[from Gevins, 1994].
![Page 17: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/17.jpg)
Signal Processing
t
v(t)original signal filtered signal rectified signal averaged signal
[from Gevins, 1994].
![Page 18: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/18.jpg)
Amplifier Specifications
High input impedanceHigh input impedance High noise rejectionHigh noise rejection Amplify 10-100 Amplify 10-100 V input signalV input signal Minimal power consumptionMinimal power consumption Low costLow cost
![Page 19: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/19.jpg)
Amplifier Design
![Page 20: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/20.jpg)
Test Results
Gain of approximately 19,000 at 10 HzGain of approximately 19,000 at 10 Hz
High common mode rejection ratioHigh common mode rejection ratio
Attenuated DC offsetAttenuated DC offset
![Page 21: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/21.jpg)
Filter Specifications
Distinguish alpha, theta bandsDistinguish alpha, theta bands Low complexityLow complexity Minimal power consumptionMinimal power consumption Low costLow cost
![Page 22: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/22.jpg)
Alpha Circuit
![Page 23: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/23.jpg)
Theta Circuit
![Page 24: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/24.jpg)
Test ResultsFrequency Response of Theta Filter
0
100
200
300
400
500
600
0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Hz
Am
pit
ud
e (
mV
)
![Page 25: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/25.jpg)
Feedback
Amy LiAmy Li
![Page 26: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/26.jpg)
Specifications
Make meditation more fulfillingMake meditation more fulfilling Pleasant, easy to understand feedbackPleasant, easy to understand feedback Low costLow cost Technically feasibleTechnically feasible
![Page 27: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/27.jpg)
Feedback Essential Points
Starts with high pitched toneStarts with high pitched tone User chooses to train for alpha or theta stateUser chooses to train for alpha or theta state Pitch varies in proportion to strength of Pitch varies in proportion to strength of
desired statedesired state
![Page 28: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/28.jpg)
04/21/23
FeedbackStrategy
High pitch
High Volume Lower pitch
Lower Volume
**Attained Ideal Deep Meditative State**
Silence
Pitch and volume increases
again
If meditative state is lost
TargetTarget
1. 2.3.
4.
5.
![Page 29: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/29.jpg)
Feedback Circuit - Summing Amplifier
![Page 30: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/30.jpg)
Feedback Circuit - Variable Gain Amplifier
![Page 31: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/31.jpg)
Research Results
Best performed with eyes closedBest performed with eyes closed Auditory signals most effectiveAuditory signals most effective
Volume change difficult to detectVolume change difficult to detect Pitch change easy to detectPitch change easy to detect
Vibrations, thermal signals, artificial tones Vibrations, thermal signals, artificial tones less effectiveless effective
![Page 32: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/32.jpg)
Changing Tone
ProsPros Technically simpleTechnically simple Less distracting Less distracting
than musicthan music Easy to detect pitch Easy to detect pitch
changechange
ConsCons ““tone deafness”tone deafness” Intrusive soundIntrusive sound
![Page 33: University of Wisconsin – Madison University of Wisconsin – Madison Engineering Projects In Community Service BIOFEEDBACK / STRESS MANAGEMENT May 9, 2001.](https://reader035.fdocuments.in/reader035/viewer/2022070409/56649e895503460f94b8ec95/html5/thumbnails/33.jpg)
Questions?