UNITED STATES DEPARTMENT OF THE INTERIOR...

6
RECEIVED Form 3160-5 UNITED STATES (August2007) cr ^ DEPARTMENT OF THE INTERIOR BUREAU OF LAND MANAGEMENT Buu^0n,S,jNDRY NOTICES AND REPORTS ON WELLS DOhot use this form for proposals to drill or to re-enter an abandoned well. Use Form 3160-3 (APD) for such proposals. FORM APPROVED OMB No. 1004-0137 Expires: July 31,2010 5. Lease Serial No. SF-080245 6. If Indian, Allottee or Tribe Name SUBMIT IN TRIPLICATE - Other instructions on page 2. 7. IfUnit of CA/Agreement, Name and/or No. 1. Type of Well Oil Well [x] Gas Well Q Other 8. Well Name and No. Hamner#3E 2. Name of Operator ConocoPhillips Company 9. API Well No. 30-045-24800 3a Address 3b. Phone No. (include area code) PO Box 4289, Farmington, NM 87499 (505) 326-9700 10. Field and Pool or Exploratory Area Basin Dakota 4. Location of Well (Footage, Sec., T..R.M., or Survey Description) UL M (SWSW), 970' FSL & 870' FWL, SEC. 29, T29N, R9W 11. Country or Parish, State San Juan , New Mexico 12. CHECK THE APPROPRIATE BOX(ES) TO INDICATE NATURE OF NOTICE, REPORT OR OTHER DATA TYPE OF SUBMISSION TYPE OF ACTION [ X | Notice of Intent | Acidize Deepen ^ Production (Start/Resume) | | Water Shut-Off Alter Casing | Fracture Treat Reclamation Well Integrity | Subsequent Report Casing Repair ^ New Construction | Recomplete Other u ^ Change Plans | X | Plug and Abandon ^ Temporarily Abandon _| Final Abandonment Notice ^ Convert to Injection ^ Plug Back Water Disposal 13. Describe Proposed or Completed Operation: Clearly state all pertinent details, including estimated starting date of any proposed work and approximate duration thereof. If the proposal is to deepen directionally or recomplete horizontally, give subsurface locations and measured and true vertical depths of all pertinent markers and zones. Attach the bond under which the work will be performed or provide the Bond No. on file with BLM/BIA Required subsequent reports must be filed within 30 days following completion of the involved operations. If the operation results in a multiple completion or recompletion in a new interval, a Form 3160-4 must be filed once Testing has been completed. Final Abandonment Notices must be filed only after all requirements, including reclamation, have been completed and the operator has determined that the site is ready for final inspection.) ConocoPhillips Company requests permission to P&A the subject well per the attached procedure, current and proposed wellbore schematics. The Pre Disturbance Site Visit was held on 9/21/15 with Bob Switzer/BLM. The Re-Vegetation Plan is attached. A Closed Loop System will be used. SSSSt* ON FEDERAL AND INDIAN LANDS Notify NMOCD 24 hrs priori to beginning operations SEE ATTACHED FOR CONDITIONS OF APPROVAL OIL CONS. DIVDIST.3 OCT 16 2015 Title 18U.S.C. Section 1001 and Title 43 U.S.C. Section 1212, make it a crime for any person knowingly and willfully to make to any department or agency of the United States any false, fictitious or fraudulent statements or representations as to any matter within its jurisdiction. 0? (Instruction on page 2) NMOCD

Transcript of UNITED STATES DEPARTMENT OF THE INTERIOR...

Page 1: UNITED STATES DEPARTMENT OF THE INTERIOR ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/aztec/wf/...(August2007) cr ^ DEPARTMENT OF THE INTERIOR BUREAU OF LAND MANAGEMENT Buu^0n,S,jNDRY

RECEIVEDForm 3160-5 UNITED STATES(August2007) cr ^ DEPARTMENT OF THE INTERIOR

BUREAU OF LAND MANAGEMENT

Buu^0n,S,jNDRY NOTICES AND REPORTS ON WELLS

DO‘hot use this form for proposals to drill or to re-enter an

abandoned well. Use Form 3160-3 (APD) for such proposals.

FORM APPROVED

OMB No. 1004-0137

Expires: July 31,2010

5. Lease Serial No.

SF-0802456. If Indian, Allottee or Tribe Name

SUBMIT IN TRIPLICATE - Other instructions on page 2. 7. If Unit of CA/Agreement, Name and/or No.

1. Type of Well

Oil Well [x] Gas Well Q Other 8. Well Name and No.

Hamner#3E2. Name of Operator

ConocoPhillips Company9. API Well No.

30-045-248003a Address 3b. Phone No. (include area code)

PO Box 4289, Farmington, NM 87499 (505) 326-970010. Field and Pool or Exploratory Area

Basin Dakota

4. Location of Well (Footage, Sec., T..R.M., or Survey Description)

UL M (SWSW), 970' FSL & 870' FWL, SEC. 29, T29N, R9W11. Country or Parish, State

San Juan , New Mexico

12. CHECK THE APPROPRIATE BOX(ES) TO INDICATE NATURE OF NOTICE, REPORT OR OTHER DATA

TYPE OF SUBMISSION TYPE OF ACTION

[ X | Notice of Intent | Acidize Deepen ^ Production (Start/Resume) | | Water Shut-Off

Alter Casing | Fracture Treat Reclamation Well Integrity

| Subsequent Report Casing Repair ^ New Construction | Recomplete Other

u^ Change Plans | X | Plug and Abandon ^ Temporarily Abandon

_| Final Abandonment Notice ^ Convert to Injection ^ Plug Back Water Disposal

13. Describe Proposed or Completed Operation: Clearly state all pertinent details, including estimated starting date of any proposed work and approximate duration thereof.

If the proposal is to deepen directionally or recomplete horizontally, give subsurface locations and measured and true vertical depths of all pertinent markers and zones.

Attach the bond under which the work will be performed or provide the Bond No. on file with BLM/BIA Required subsequent reports must be filed within 30 days

following completion of the involved operations. If the operation results in a multiple completion or recompletion in a new interval, a Form 3160-4 must be filed once

Testing has been completed. Final Abandonment Notices must be filed only after all requirements, including reclamation, have been completed and the operator has

determined that the site is ready for final inspection.)

ConocoPhillips Company requests permission to P&A the subject well per the attached procedure, current and proposed wellbore schematics. The Pre Disturbance Site Visit was held on 9/21/15 with Bob Switzer/BLM. The Re-Vegetation Plan is attached. A Closed Loop System will be used.

SSSSt*ON FEDERAL AND INDIAN LANDS

Notify NMOCD 24 hrs priori to beginning

operations

SEE ATTACHED FOR CONDITIONS OF APPROVAL

OIL CONS. DIVDIST.3

OCT 16 2015

Title 18U.S.C. Section 1001 and Title 43 U.S.C. Section 1212, make it a crime for any person knowingly and willfully to make to any department or agency of the United States any

false, fictitious or fraudulent statements or representations as to any matter within its jurisdiction. 0?(Instruction on page 2)

NMOCD

Page 2: UNITED STATES DEPARTMENT OF THE INTERIOR ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/aztec/wf/...(August2007) cr ^ DEPARTMENT OF THE INTERIOR BUREAU OF LAND MANAGEMENT Buu^0n,S,jNDRY

ConocoPhillips HAMNER 3E

Expense - P&A

Lat 36° 41' 31.589" N Long 107° 48’ 31.32" WPROCEDURENOTE: This is a dual well with a Model F packer set at 6,460'This project requires the use of an A-Plus steel tank to handle waste fluids circulated from the well and cement wash up.

1. Hold pre-job safety meeting. Comply with all NMOCD, BLM, and COPC safety and environmental regulations. Test rig anchors prior to moving in rig. Before RU, run WL remove downhole equipment. If an obstruction is found, set a locking-3-slip-stop in the tubing.

2. MIRU workover rig. Check casing, tubing, and bradenhead pressures and record them in Wellview. If there is pressure on the BH,contact the Wells Engineer.

3. Remove existing piping on casing valve. NOTE: This is a dual well with a packer. RU blow lines from casing valves and begin blowing down casing pressure. Kill well as necessary, down casing and down Dakota tubing. Ensure well is dead or on a vacuum.

4. ND wellhead and NU normal double BOP with 2-3/8" pipe rams and a single BOP with offset 1-1/4" pipe rams and offset spool for short string. Pressure and function test BOP to 250 psi low and 1,000 psi over SICP high to a maximum of 2,000 psi held and charted for 10 minutes as per COP Well Control Manual. PU and remove tubing hanger

5. Unseat the short string of tubing. TOOH and LD short string from the Chacra formation. Remove the offset spool and offset rams.

NOTE ON PACKER: Packer is a 4-1/2" Model "F" packer set in 1981. Straight pickup should release the assembly.6. PU on tubing and release the seal assembly on 4-1/2" Model "F" packer with straight pickup. If seal assembly does not release or POOH, contact Wells Engineer. TOOH with with tubing (per pertinent data sheet.) Blast joints are placed in tubing string at 3,094' and 3,196'.

Tubing size: 2-3/8" 4.7# J-55 EUE Set Depth: 6,484' KB: 13'

7. PU 3-7/8" bit and watermelon mill and round trip as deep as possible above top Dakota perforation at 6,482'.

8. PU 4-1/2" CR on tubing, and set a 6,432'. Pressure test tubing to 1,000 psi. Sting out of CR. Load hole, and pressure test casing to 800 psi. If casing does not test, then spot or tag subsequent plugs as appropriate. POOH w/ tubing.

All cement volumes use 100% excess outside pipe and 50' excess inside pipe. The stabilizing wellbore fluid will be 8.3 ppg, sufficient to balance all exposed formation pressures. All cement will be ASTM Class B mixed at 15.6 ppg with a 1.18 cf/sk yield.

9. Plug 1 (Dakota Perforations, Dakota and Graneros formation tops, 6332-6432', 12 Sacks Class B Cement)Mix 12 sx Class B cement and spot a balanced plug inside the casing to cover the Dakota perforations and Dakota and Graneros formation tops. PUH.

10. Plug 2 (Gallup formation top, 5538-5638', 12 Sacks Class B Cement)Mix 12 sx Class B cement and spot a balanced plug inside the casing to cover the Gallup formation top. PUH.

11. Plug 3 (Mancos formation top, 4710-4810', 12 Sacks Class B Cement)Mix 12 sx Class B cement and spot a balanced plug inside the casing to cover the Mancos formation top. PUH.

12. Plug 4 (Mesaverde formation top, 3750-3850', 12 Sacks Class B Cement)Mix 12 sx Class B cement and spot a balanced plug inside the casing to cover the Mesaverde formation top. POOH.

Page 3: UNITED STATES DEPARTMENT OF THE INTERIOR ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/aztec/wf/...(August2007) cr ^ DEPARTMENT OF THE INTERIOR BUREAU OF LAND MANAGEMENT Buu^0n,S,jNDRY

13. Plug 5 (Chacra Perforations, Chacra formation top, 2955-3055', 12 Sacks Class B Cement)RIH with a 4-1/2" CR and set at 3,065'. Mix 12 sx Class B cement and spot a balanced plug inside the casing to cover the Chacra formation top and Chacra perforations. POOH.

14. RU wireline and run CBL with 500 psi on casing from CR to surface to identify TOC. Adjust plugs as necessary for new TOC. Email log copy to Troy Salyers (BLM) at [email protected] and Brandon Powell (NMOCD) at [email protected] upon completion of logging operations.

15. Plug 6 (Production Liner Top, 2477-2577’, 27 Sacks Class B Cement)Mix 29 sx Class B cement and spot a balanced plug inside the casing to cover the production liner top. PUH.

16. Plug 7 (Pictured Cliffs formation top, 2071-2171', 29 Sacks Class B Cement)Mix 29 sx Class B cement and spot a balanced plug inside the casing to cover the Pictured Cliffs formation top. PUH.

17. Plug 8 (Fruitland Coal formation top, 1712-1812', 29 Sacks Class B Cement)Mix 29 sx Class B cement and spot a balanced plug inside the casing to cover the Fruitland Coal formation top. PUH.

18. Plug 9 (Kirtland and Ojo Alamo formation top, 923-1203', 29 Sacks Class B Cement)Mix 62 sx Class B cement and spot a balanced plug inside the casing to cover the Kirtland and Ojo Alamo formation tops. POOH.

19. Plug 10 (Surface casing shoe and Surface plug, 0-328', 131 Sacks Class B Cement)RU WL and perforate 4 big hole charge (if available) squeeze holes at 328'. TOOH and RD wireline. Observe well for 30 minutes per BLM regulations. RU pump, close blind rams and establish circulation out bradenhead with water. Circulate BH clean. TIH with 7” CR and set at 278’. Mix 60 sx Class B cement and squeeze until good cement returns to surface out BH valve. Shut BH valve and squeeze to max 200 psi. Sting out of CR and reverse circulate cement out of tubing. TOOH and LD stinger. TIH with open ended tubing to 278’. Mix71 sx Class B cement and pump inside plug. TOOH and LD Tubing. SI well and WOC.

20. Nipple down BOP and cut off casing below the casing flange. Install P&A marker with cement to comply with regulations. Rig down, move off location, cut off anchors, and restore location.

Page 4: UNITED STATES DEPARTMENT OF THE INTERIOR ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/aztec/wf/...(August2007) cr ^ DEPARTMENT OF THE INTERIOR BUREAU OF LAND MANAGEMENT Buu^0n,S,jNDRY

1 TUBING: 1 1/4 in:2.501.0ftKB: 2.525.0ftKB

ITOL © 252T1-

CHACRAL.3jmQ-^,11Q,Q;Blast Joints; 3.10 in;4.70 Ibfltr 3,094.0 ftKB;3.134.0 ftKB

Tubing: 2 3/8 in; 4.70 IbTt; 2 3/8 © 6602 - 11/4 ________© 310:3,134.0 ftKB: 3.196.0 ftKB

Blast Joints; 3.10 in;4.70 lb»*ft; 3.196.0 ftKB;3.242.0 ftKB

Tubing; 2 3/8 in: 4.70 Ibffl; 2 3/8 © 6602 - 1 1/4 © 310:3242.0 ftKB: 6.435.0 ftKB

liding Sleeve:23m in; 4.70 Ib/ft 2.375X 1.87 MODEL L SLIDING SLEEVE; 6,435.0 ftKB:

___________________________ 6.440,0 ftKBTubing: 2 3/8 in: 4.70 Ibrtt 2 3/8 © 6602 - 1 1/4

© 310; 6.440.0 ftKB: 6,446.0 ftKB ^Packer; 4 1/2 in: 4.70 Ib/ft; 6.446.0 ftKB; 6,451.0

-4|ftKB—| Seal Assembly; 2 3/8 in; 4.70 I bit 40-26 G-22

LOCATOR SEAL ASSEMBLY WfTH 3 SEAL UNITS WFTH 2J575 EU 3RD BOX X 2.12 1DRD___________PtNf.8); 6.451.0 ftKB: 6,456.0 ftKB

[Tubing Sub: 23/8 in; 4.70 Ib/ft; 6.458.D ftKB;6.462.0 ftKB

I Seating Mipple;2 3/8 in; 4.70 Ib/ft: SEATING NIPPLE tS MODEL F 1.5 EU X 1.43; 6.462.0

ftKB: 5.463.Q ftKB Tubing Sub: 2 2/8 in; 4.70 Ib/ft 6.463.0 ftKB:

_________________ 6,483.0 ftKB

ConocoPhillipsBaste- Schematic - Current

HAMNER #3E

DistrictSOUTH

I Reid Name CKjBK DUAL

API! UVH 3CO4524800

County SAN JUAN

StatefFrowince

NEW MEXICOOriginal Spud Date Surface Legal Location East!West Distance [ft; East*West Reference Worth)South Distance [ft? NorthJSouth Reference

4/2/1981 NMPM-29N-90W-29-M 870.00 W 970.00 S

Vertical - Original Hole, 8/18/20154:27:23 PMMDtftKB} Vertical schematic factual?

0.3

276.9

225.1

973.1

1.762.1

2.32.0

2501.9

2526.9

2703.1

3,284.2

3.109.9

3.133.9

3.208.0

3.242.1

3.S3Q.I

4.759.S

6.354.0

6.435.0

6.445.9

6.456.0

6.462.9

6.4B2.0

6.453.9

6.525.1

6.603.0

6.623.0

6.653.9

6.658.1

I TUBING: 1 1/4 in: 13,0 ftKB: 2.500.0 ftKBTubing; 2 3/8 in; 4.70 ib-tt; 2 3/8 © 6602 - 1 1/4

© 310:13.0 ftKB: 3.C94.0 ftKB

lUe Shoe Guide: 23IS in; 4.70 Ib/ft; 6.483.0 __________________ ftKB: 6.484.0 ftKB

1; Surface: 9 5/8 in: 8.921 in; 13.0 ftKB: Discrepancy between drilling rpt and completion rpton Surface casing set depth. Used Drilling rpt set depth 278*.; 278,0 ftKB

2: Intermediate!; 7 in;6.370 in; 13.0 ftKB: 2,700.0 ftKB

CHACRA: 3.127.0-3.134.0: 6H Bn 5S1

IPERF - CHACRA: 3208.0^234.0:6/16/1981

IPERF - DAKOTA: 6.482.06.491.0: SIB/1381

- DAKOTA: 6 53S.0-6.S56 0: 5/15/1581 I

- DAKOTA: 6.603.0^.607.0: S15/1S81 [

IPERF- DAKOTA: 6.S23.&6.631.0: E/19/1981

3; Production!: 4172 in; 4.050 in; 2,527.0 ftKB: '6,558.0 ftKB

Page 1/1 Report Printed: 8/18/2015

Page 5: UNITED STATES DEPARTMENT OF THE INTERIOR ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/aztec/wf/...(August2007) cr ^ DEPARTMENT OF THE INTERIOR BUREAU OF LAND MANAGEMENT Buu^0n,S,jNDRY

API LAVI

300452480D

vr. Proposed SchematicIPS

INER #3E

S^K2Lag3£LX3ton FjetfSareN MPM-29N-90W-29- M CH/DK DUAL InMWfln

NEW MEXICOVIM ConTgirHlon Type

Vertical(1^. origins =rr season ;tt>

5,761 .CO 13.0 13.00

Vertical - Original Hole, 1/1/2020Vertical schematic (actual! MD (ftKB) Formation Tops

iCement Retainer: 278.P-281.ol

lTOHB>2527r1

ICement Retainer 3.065.0-3.068.0I-

__ Hydraulic Fracture; 6/18/1981:.FRAC WITH 75D0D GAL 70%

QUAL FOAM AND 80000ft 20/40 SAND

Hydraulic Fracture: 6/18/1981: TREAT WITH 1600 GAL 15% HCL

114-1.1SPEC GRAV BALLS

—ICement Retainer: 6.432.0-6.435.54- Hydraulic Fracture: 5/23/1981; \

FRAC WITH 90000 GAL 30SX-L _ GEL AND 160000ft 20/40 SAND

AND 13.33 MI LLI CURIES RADIOACTIVE SAND

Hydraulic Fracture; 5/23/1981; TREAT WITH 1800 GAL 15%

WEIGHTED HCL 113 1.1 SPEC GRAV BALLS

r; siraa; 9 sa n, asst xtz im a® psc-aarcy MMeai arsing rp and '•aoirpJsBan sp. an Salazz casing &a stepfu iUsad ug-iicng ra sa -assgi 278.21<5 iMB casing car-ant URNS 8BR

vr,rt sc sx Cass a \aat Cnrc,£aed toss

ot~=r: 3CS 3-, t.-rtaag I iRug =10; 13.G-22S 3; 1,1/2020 >.!:* 52 £>:CtasE S samsst spot*aearcad »jg Inside H Z3srg tscavar KSTand&qpA&fraBrTaEan

rjg yig azso:1.0,2020 IPlug 9210-1,023.0: 11,-2020; US 52 OCClass 5 saned sacJfcafiarced »ug tns'da casing S3 oarer Kimarcl A Ott Mans SmroSor

mg =s; i;.7t20-r,ai2.0: 112220: w.» 29 sx 5 sarr-£rt spa naantaa plug nsi-da ------ avg ynciana ccai ferraron as.

«•; 2j071J3-ZtTt.0; 1,10323: WBX 29sx 15 semottscaiaarcad sug msvas |a cj,g enured cm ignratan oc. r55: 2,477-0-2,577.0; t. t-COCO; U S 29 SX 15 warrant spot taarcad plug inside itn—BtHe—UMria

wanr-adast: 7 4r fL37C 13.0 tt®2708.0 «5_________________________________

nrarmasEg Casing carant 9600-2,7000: 4®1SM; Cmfd •*&03 sx 5050 POZ •»«** G3 150 PC CSSS 5.Plug «; 2955.0-3.055.0: 1.1.2320; USX 12 SX CS3ss 5 carad.spotcsarcadcug tt£>da rasng B carer caaaa Brratan nc acnasa

__________________________________

■iPgxF - CWACWA: 3.105.0-3.113.0: &1S19S1 I

BBS - CHACRA: 3.127,0-3.1340: 6-151981 I

yV) ------------------ C"AC=A 3.::.3.:-3.234.Q- 5 15 1951

Sg'S: sjsia-iasao: twaaKM&c 12 sx csss 3 tansn spot taarcad pug asas 3SSISLSCT^W^M.ariBfflan Bp,____

Rug «: 4.7100-4,810.0; utaoso: mzx 12 ex I 5 canan s^oi taarcad aug inside tre s3sno scorer Marcos trxaKnpc.

png *2: 5^330-5,535.0: USEE SE 12 sx Class a carsm tpol Caarced pug nsas C3SCT3 B C01g G3Pig 13TT3ttg1Bfc

J-jg =1: 6,332.0-5.532.0: V9K USX 12 SX

CS6S 3 arart spotsasrca'l pug *nr>de rasng B carer Catena pans a Dacca a 3-ana- := txT.Htsn ass.

DAKOTA: 5.432.0-5.491.0: MSTt981

DACOTA: 5.535.0-a.555.g- S19i19Sti- - DAKOTA: 5503.0-5.5070: 515-1961 ~ - DAKOTA. 5-523.0-5.531-3: &19*198t

I...... . i ii ii 111 i iii I'lhi Mrd '*,'-550 SX 5535. aaa3w453SXC35S 5

M Hanarseoui 500 ar t Mtoo amt phg: 5,5543-5,5580; 4H;i98t; Autonstcaey aaasad camam pig tarn re :35TB car.-im fcecajoe ii ,"aa 3 tajoad dscm.

13, Producsonl; 4 V2 Sn; 4.050 X 2527,3 1X5,

nspay car era Fuc 6,553.0^3.0;

iijm

13.1

277.9

285.1

922.9

973.1

1.152.9

1.762.1

2.070.9

2.170.9

2.477.0

2.577.1

2.700.1

3.055.1

3.067.9

3.105.0

3.127.0

3.208.0

3.750.0

3.830.1

4.399.9

4.759.8

5.538.1

5.638.1

6.354.0

6.432.1

6.474.1

6.491.1

6.556.1

6.607.0

6.630.9

6.657.2

6.659.1

NACIMIENTO

OJO ALAMO

KIRTLAND

FRUITLAND

PICTURED CUFFS

LEWIS

CUFF HOUSE MENEFEE

POINT LOOKOUT

MANGOS

GALLUP

GREENHORNGRANEROS

TWO WELLS

Page 1/1 Report Printed: 8/25/2015

Page 6: UNITED STATES DEPARTMENT OF THE INTERIOR ...ocdimage.emnrd.state.nm.us/Imaging/FileStore/aztec/wf/...(August2007) cr ^ DEPARTMENT OF THE INTERIOR BUREAU OF LAND MANAGEMENT Buu^0n,S,jNDRY

UNITED STATES DEPARTMENT OF THE INTERIOR BUREAU OF LAND MANAGEMENT FARMINGTON DISTRICT OFFICE

6251 COLLEGE BLVD. FARMINGTON, NEW MEXICO 87402

Attachment to notice of Intention to Abandon:

Re: Permanent Abandonment Well: Hamner#3E

CONDITIONS OF APPROVAL1. Plugging operations authorized are subject to the attached "General Requirements for Permanent Abandonment of Wells on Federal and Indian Lease."

2. Farmington Office is to be notified at least 24 hours before the plugging operations commence (505) 564-7750.

3. The following modifications to your plugging program are to be made:

a) Set Plug #3 (4950-4850) ft. to cover the Mancos top. BLM picks top of Mancos at 4900 ft.

b) Set a cement plug (3064-2964) ft. to cover the Chacra top. BLM picks top of Chacra at 3014 ft.

c) Set Plug #8 (1917-1817) ft. to cover the Fruitland top. BLM picks top of Fruitland at 1867 ft.

d) Set Plug #9 (1217-967) ft. to cover the Kirtland and Ojo Alamo tops. BLM picks top of Ojo Alamo at 1017 ft. BLM picks top of Kirtland at 1167 ft.

Low to high concentrations of H2S (4 ppm -226 ppm GSV) have been reported in wells within a 1 mile radius of this location.

You are also required to place cement excesses per 4.2 and 4.4 of the attached General Requirements.

Office Hours: 7:45 a.m. to 4:30 p.m.