UNARMOURED ENERGY CABLE NYYNYY CABLE DIMENSIONS Cores x 2 Weight kg / km 2 x 1.5 11.5 190 2 x 2.5...

1
UK Cables the only way to be sure! www.ukcables.co.uk Aberdeen Birmingham Glasgow Gateshead Manchester London T: 01224 898114 T: 0121 565 7040 T: 0141 779 7804 T: 0191 487 2000 T: 0161 653 6789 T: 01708 86446 F: 01224 898900 F: 0121 565 7050 F: 0141 779 7801 F: 0191 487 2022 F: 0161 653 7184 F: 01708 865385 [email protected] [email protected] [email protected] [email protected] [email protected] [email protected] A 600/1000 Volt power cable for fixed energy supply where mechanical protection is not of primary consideration. Suitable for both indoor and outdoor applications in free air, ducts or direct burial, subject to regulations locally. A cost effective solution for power and control applications with weight and termination time savings due to lack of mechanical armour. CONSTRUCTION Plain copper conductor solid, class 1, or stranded, class 2, PVC insulation colour coded, cores laid up with fully filled inner sheathing compound with black PVC sheath overall. TECHNICAL DATA VDE 0276 pt 603 to 5 cores pt 627 7 cores and above. IEC 60502-1 Nominal Voltage 600/1000V Test Voltage 2000V Operating Temperature Mobile -30ºC to +70ºC Bending Radius 15 times O/D single core 12 times O/D multi core Flame Propagation BS EN 60332-1-2 Current Rating Table Please request Data Sheet Single Core x mm 2 Nom Dim mm Weight kg / km 16.0 11.0 260 25.0 12.5 370 35.0 13.5 490 50.0 15.5 640 70.0 17.0 830 95.0 19.0 1110 120.0 20.5 1350 150.0 22.5 1650 240.0 24.5 2040 300.0 27.5 2610 400.0 30.5 3300 500.0 33.5 4200 630.0 38.0 5160 NYY CABLE DIMENSIONS Cores x mm 2 Nom Dim mm Weight kg / km 2 x 1.5 11.5 190 2 x 2.5 12.5 230 2 x 4.0 14.0 310 2 x 6.0 15.0 370 2 x 10.0 16.5 500 2 x 16.0 18.5 660 3 x 1.5 12.0 210 3 x 2.5 13.0 260 3 x 4.0 14.5 360 3 x 6.0 16.0 440 3 x 10.0 17.5 600 3 x 16.0 19.5 820 3 x 25.0 23.5 1250 4 x 1.5 13.0 250 4 x 2.5 14.0 310 4 x 4.0 15.5 420 4 x 6.0 17.0 530 4 x 10.0 19.0 730 4 x 16.0 21.5 1030 4 x 25.0 25.5 1550 4 x 35.0 28.5 2050 5 x 1.5 13.5 290 5 x 2.5 15.0 360 5 x 4.0 17.0 500 7 x 1.5 14.5 340 7 x 2.5 15.8 425 Note - Minimum installation temperature 0 º C NYY-J core identification chart - Single Core: Green/Yellow 3 core: Brown - Blue - Green/Yellow 4 core: Brown - Black - Grey - Green/Yellow 5 core: Brown - Black - Grey - Blue - Green/Yellow 7+ core: Number Coded plus Green/Yellow NYY-O core identification chart - Single Core: Black 2 core: Brown - Blue 3 core: Brown - Black - Grey 4 core: Brown - Black - Grey - Blue 5 core: Brown - Black - Grey - Blue - Black 7+ core: Number Coded UNARMOURED ENERGY CABLE NYY

Transcript of UNARMOURED ENERGY CABLE NYYNYY CABLE DIMENSIONS Cores x 2 Weight kg / km 2 x 1.5 11.5 190 2 x 2.5...

Page 1: UNARMOURED ENERGY CABLE NYYNYY CABLE DIMENSIONS Cores x 2 Weight kg / km 2 x 1.5 11.5 190 2 x 2.5 12.5 230 2 x 4.0 14.0 310 2 x 6.0 15.0 370 2 x 10.0 16.5 500 2 x 16.0 18.5 660 3 x

UK Cables – the only way to be sure!

www.ukcables.co.uk

Aberdeen Birmingham Glasgow Gateshead Manchester London

T: 01224 898114 T: 0121 565 7040 T: 0141 779 7804 T: 0191 487 2000 T: 0161 653 6789 T: 01708 86446

F: 01224 898900 F: 0121 565 7050 F: 0141 779 7801 F: 0191 487 2022 F: 0161 653 7184 F: 01708 865385

[email protected] [email protected] [email protected] [email protected] [email protected] [email protected]

A 600/1000 Volt power cable for fi xed energy supply where mechanical protection is not of primary consideration. Suitable for both indoor and outdoor applications in free air, ducts or direct burial, subject to regulations locally. A cost effective solution for power and control applications with weight and termination time savings due to lack of mechanical armour.

CONSTRUCTION

Plain copper conductor solid, class 1, or stranded, class 2, PVC insulation colour coded, cores laid up with fully fi lled inner sheathing compound with black PVC sheath overall.

TECHNICAL DATA

VDE 0276 pt 603 to 5 cores pt 627 7 cores and above. IEC 60502-1

Nominal Voltage 600/1000V

Test Voltage 2000V

Operating Temperature Mobile -30ºC to +70ºC

Bending Radius15 times O/D single core12 times O/D multi core

Flame Propagation BS EN 60332-1-2

Current Rating Table Please request Data Sheet

SingleCore x mm2

Nom Dimmm

Weight kg / km

16.0 11.0 26025.0 12.5 37035.0 13.5 49050.0 15.5 64070.0 17.0 83095.0 19.0 1110

120.0 20.5 1350150.0 22.5 1650240.0 24.5 2040300.0 27.5 2610400.0 30.5 3300500.0 33.5 4200630.0 38.0 5160

NYY CABLE DIMENSIONS

Cores x mm2

Nom Dimmm

Weight kg / km

2 x 1.5 11.5 1902 x 2.5 12.5 2302 x 4.0 14.0 3102 x 6.0 15.0 370

2 x 10.0 16.5 5002 x 16.0 18.5 6603 x 1.5 12.0 2103 x 2.5 13.0 2603 x 4.0 14.5 3603 x 6.0 16.0 440

3 x 10.0 17.5 6003 x 16.0 19.5 8203 x 25.0 23.5 12504 x 1.5 13.0 2504 x 2.5 14.0 3104 x 4.0 15.5 4204 x 6.0 17.0 530

4 x 10.0 19.0 7304 x 16.0 21.5 10304 x 25.0 25.5 15504 x 35.0 28.5 20505 x 1.5 13.5 2905 x 2.5 15.0 3605 x 4.0 17.0 5007 x 1.5 14.5 3407 x 2.5 15.8 425

Note - Minimum installation temperature 0ºC NYY-J core identifi cation chart - Single Core: Green/Yellow3 core: Brown - Blue - Green/Yellow4 core: Brown - Black - Grey - Green/Yellow5 core: Brown - Black - Grey - Blue - Green/Yellow7+ core: Number Coded plus Green/Yellow

NYY-O core identifi cation chart - Single Core: Black2 core: Brown - Blue3 core: Brown - Black - Grey4 core: Brown - Black - Grey - Blue5 core: Brown - Black - Grey - Blue - Black7+ core: Number Coded

UNARMOURED ENERGY CABLE NYY