UNA-CLAD™ Metal Roof Systems

Underwriters Laboratories (UL)

UL Roof Deck Constructions and “P” Assemblies

Factory Mutual Approvals (FM)

Page 2: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

2 | P a g e

J u n e 2 0 1 4

Table of Contents 1.01 EXTERNAL FIRE RATINGS ................................................................................................................. 7

Assemblies are updated March 2014. Please utilize the UL website to verify the assembly number associated with each listed assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Table 1.01a: .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

UL External Fire Rated Assemblies .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8

Table 1.01a (Cont.): . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

UL External Fire Rated Assemblies .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

Table 1.01b ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

UL External Fire Rated Assemblies .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

1.02 Impact Resistance ............................................................................................................................... 10

Table 1.02 ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

UL Impact Resistance Rated Panels .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

(only Steel, copper or aluminum, any thickness) .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

1.03 Wind Uplift Ratings - UL ...................................................................................................................... 10

Table 1.03a ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

UL 580 Test Pressures by Class .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10

Maximum Static Uplift Pressure (psf) .............................................................................................. 10

Assemblies are updated March 2014. Please utilize the UL website to verify the assembly number associated to each listed assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Table 1.03b ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11

Table 1.03b ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12

Table 1.03b ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13

Thermal Board .................................................................................................................................... 13

N/A ....................................................................................................................................................... 13

Type 15 or 30 organic felt, side laps min 2”, end laps per manufacturer's recommendations. When optional plywood is used, stapled with 5/16” long staples 6” o.c. side laps and 12” o.c. in two interior rows. ..................................................................................................................................................... 13

Width: .................................................................................................................................................. 13

Min. 12” Max. 20” ............................................................................................................................... 13

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14

One layer Elk Versa Shield with 2” side lap, loose laid. ...................................................................... 14

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15

Table 1.03b Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Page 3: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

3 | P a g e

J u n e 2 0 1 4

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 16

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 24

Type 30 organic felt. ............................................................................................................................ 24

Type 30 organic felt. Sides overlapped min 2”. end laps per manufacturer's instructions. Felt nailed to nailable insulation with 1” long galvanized steel roofing nails, located in side laps and between side laps per manufacturer's instructions. Nail spacing to be max. 12” o.c. at the side lap and max. 24” o.c. in interior rows. .............................................................................................................................. 24

Width: .................................................................................................................................................. 24

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 25

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

N/A ....................................................................................................................................................... 28

Width: .................................................................................................................................................. 28

Table 1.03b ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

UL 580, Class 90 Rated Roof Deck Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28

Page 4: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

4 | P a g e

J u n e 2 0 1 4

4. UL 1897 Test ing: Test is conducted in accordance with UL 1897 “Uplift Test for Roof Covering System s” . The test m ethod subjects a m inimum 10 ft by 10 ft sample to various short term (one m inute increments) stat ic air pressure to index performance under uplift loads imposed on a roofing system ’s securem ent to a specified roof deck. .. . . . . . . . . . . . . . . . . . 29

Assemblies are updated March 2014. Please utilize the UL website to verify the assembly number associated to each listed assembly. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Table 1.03c ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

UL 1897 Tested Roof Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29

Table 1.03b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

UL 1897 Tested Roof Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30

Table 1.03c ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

UL 1897 Tested Roof Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Table 1.03c ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

UL 1897 Tested Roof Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31

Table 1.03c ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

UL 1897 Tested Roof Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Table 1.03c ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

UL 1897 Tested Roof Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

Table 1.03c ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

UL 1897 Tested Roof Constructions ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32

1.04 Internal Fire (“P” Assemblies) ............................................................................................................ 33

1.05 STATE OF FLORIDA and MIAMI-DADE APPROVALS .................................................................... 33

Table 1.05a ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

State of Florida Product Approval . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Table 1.05b ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Miami-Dade Notice of Acceptance ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33

Table 1.05C ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Florida Building Code (HVHZ) .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

TAS 100-95 (Wind Driven Rain Test) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Table 1.05d ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Florida Building Code (HVHZ) .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

TAS 125 ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

1.06 Energy Star Approvals - As Currently Listed at www.energystar.gov ................................................ 34

Table 1.06 ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Energy Star Approvals .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34

Table 1.06 ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

Energy Star Approvals .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35

1.07 CRRC Rated Panels .......................................................................................................................... 36

Table 1.07 ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Page 5: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

5 | P a g e

J u n e 2 0 1 4

CRRC Rated Panels .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

1.08 Air Infiltration & Water Penetration ...................................................................................................... 36

Table 1.08a ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

ASTM E283 and E1680 Air Infiltration Tests .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36

Table 1.08a (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Table 1.08b ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

ASTM E331 and E1646 Water Penetration Tests .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37

Table 1.08b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

1.09 Structural Performance ....................................................................................................................... 38

Table 1.09a ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

ASTM E330 St ructural Performance Tests .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38

- 16.4 .................................................................................................................................................... 38

- 26.3 .................................................................................................................................................... 38

Table 1.09a (Cont .) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

ASTM E330 St ructural Performance Tests .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39

1.0’ ....................................................................................................................................................... 39

Table 1.09a (Cont .) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

ASTM E330 St ructural Performance Tests .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40

Table 1.09a (Cont .) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

ASTM E330 St ructural Performance Tests .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Table 1.09b ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

ASTM E1 5 9 2 St ructura l Perform ance Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41

Table 1.09b (Cont.) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

ASTM E1 5 9 2 St ructura l Perform ance Tests . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42

1.11 Concentrated Load Testing ................................................................................................................. 48

Table 1.11 Concent rated Load Test ing ... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48

Page 6: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

6 | P a g e

J u n e 2 0 1 4

Ver ify the included assem blies in the char ts below w ith the associa ted Firm ’s ( UL, FM, etc) . Not a ll of the inform at ion included in the RoofNav assem blies w ill be listed in the char ts below .

Ver ify that a ll assem blies m eet Firestone Building Products w arranty requirem ents w ith the associa ted region’s technica l team .

Page 7: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

7 | P a g e

J u n e 2 0 1 4

1.01 EXTERNAL FIRE RATINGS

1. All regional building codes and most local building code officials require that roofing systems meet minimum performance

requirements when exposed to external fire sources. The accepted method for measuring external fire resistance is ASTM

Standard E-108. This test standard, and closely related standards such as Underwriters Laboratories UL-790 and Uniform

Building Code 15-2, is used to determine the ability of a roof system to hinder the horizontal spread or vertical penetration

of an external fire source.

A. Noncombustible Roof Decks (Steel, Concrete, and Poured Gypsum) require testing for horizontal spread of flame.

B. Combustible Roof Decks (Wood, Plywood, and Tectum) require testing for both horizontal spread and vertical penetra-

tion of flame.

2. ASTM E-108, UL-790 and UBC 15-2. All classified roof covering assemblies fall into one of the three following categories:

CLASS A: “... includes roof coverings which are effective against

severe fire exposures...” (See Note 1)

CLASS B: “... includes roof coverings which are effective against

moderate fire exposures...” (See Note 1)

CLASS C: “... includes roof coverings which are effective against

light fire exposures...” (See Note 1)

3. For insulated assemblies over non-combustible roof decks, any classified roofing assembly may be installed over a new roof

deck, an existing roof deck or over an existing roofing assembly. Underwriters Laboratories states that “any classified

roofing system may be applied over a pre-existing roof system (Class A, B, C, verifiable or not) of the same deck type

and establishes for that roof the classification of the new system”. Also, an assembly classified over a combustible deck

may be installed over an existing non-combustible deck and establish for the assembly the rating of the new system. A

non-combustible deck rated assembly must be tested and classified over a combustible deck in order to obtain the desired

classification of the new assembly. Total insulation thickness of combined existing and new roofing systems may not

exceed the total maximum allowable for the new roofing system, and non-insulated systems are not intended for use over

insulated systems.

4. The class of roof covering required by each regional building code depends upon many factors, including the use and

location of the building and the type of construction. The local building authority should always be consulted as to what the

roofing assembly classification will need to be for each roofing project.

5. It should be noted that these classifications apply to roofing assemblies, and NOT the metal roofing panel. A metal

roofing panel that is classified as part of a Class A assembly when installed over a particular insulated or non-insulated

construction may not qualify as part of a Class A assembly if you make changes within the insulated or non-insulated

construction.

NOTE: The column titled “UL Item Number” in the following listings has been added as a service to those who have the UL Building

Materials Directory. It identifies the UL listing from which our Code Approval Guide listing derives (e.g. “A,FA,23” means Class A,

Fully Adhered, item number 23; “B,OS,01” means Class B, Other System, item number 01 , etc.).

(Note 1) From Underwriters Laboratories Roofing Materials and Systems Directory, January, 2007, page 1.

Page 8: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

8 | P a g e

J u n e 2 0 1 4

ASSEMBLIES ARE UPDATED MARCH 2014. PLEASE UTILIZE THE UL WEBSITE TO VERIFY THE ASSEMBLY NUMBER ASSOCIATED WITH EACH LISTED ASSEMBLY .

TABLE 1.01A:

UL External Fire Rated Assemblies SYSTEM: METAL ROOFING ASSEMBLIES: UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, UC-750, UC-500, UC-501, UR, HR CONSTRUCTION: NEW, RETROFIT

Max. Slope: Class: Deck: Insulation Assembly:

Unlimited A C-15/32

Insulation (Optional): Any thickness Firestone ISO 95+ GL Barrier Board:

1) Dens-Deck, min ¼ inch thick 2) UL Classified gypsum board, min. ½ inch thick 3) Min. one layer of Elk “Versashield”

Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing underlayment, WR Grace Ice and Water Shield, any UL Classified Type G1, G2, or G3 base/ply sheet, Type 15, 20, or 30 felt, or UL Classified prepared roofing accessory

Surfacing: One of the assemblies shown above in steel, copper, aluminum

Unlimited A C-15/32

Barrier Board: 1) Dens-Deck, min ¼ inch thick 2) UL Classified gypsum board, min. ½ inch thick 3) Min. one layer of Elk “Versashield”

Insulation (Optional): Any thickness Firestone ISO 95+ GL or HailGard Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

underlayment, WR Grace Ice and Water Shield, any UL Classified Type G1, G2, or G3 base/ply sheet, Type 15, 20, or 30 felt, or UL Classified prepared roofing accessory

Surfacing: One of the assemblies shown above in steel, copper, aluminum

Unlimited A C-15/32 or

Spaced Sheathing

Underlayment: One layer of Elk “Versashield”, MA Ply Sheet: One layer Type 30 base sheet or Elk “Versashield”, MA Insulation (Optional): Any thickness Firestone ISO 95+ GL, ISOGARD HD, or HailGard Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

underlayment, WR Grace Ice and Water Shield, any UL Classified Type G1, G2, or G3 base/ply sheet, Type 15, 20, or 30 felt, or UL Classified prepared roofing accessory

Surfacing: One of the assemblies shown above in steel or copper

Unlimited A C-15/32

Underlayment: Two layers of Elk “Versashield” Insulation (Optional): Any thickness Firestone ISO 95+ GL, ISOGARD HD, or HailGard Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

underlayment, WR Grace Ice and Water Shield, any UL Classified Type G1, G2, or G3 base/ply sheet, Type 15, 20, or 30 felt, or UL Classified prepared roofing accessory

Surfacing: One of the assemblies shown above in aluminum

Unlimited A C-15/32 or

Spaced Sheathing

Underlayment: One or more layers of Elk “Versashield”, MA Insulation (Optional): Any thickness Firestone ISO 95+ GL, ISOGARD HD, or HailGard Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

underlayment, WR Grace Ice and Water Shield, any UL Classified Type G1, G2, or G3 base/ply sheet, Type 15, 20, or 30 felt, or UL Classified prepared roofing accessory

Surfacing: One of the assemblies shown above in steel or copper

Unlimited A C-15/32 or

Spaced Sheathing

Underlayment: One or more layers of Elk “Versashield”, MA Insulation (Optional): Any thickness Firestone ISO 95+ GL, ISOGARD HD, or HailGard Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

underlayment, WR Grace Ice and Water Shield, any UL Classified Type G1, G2, or G3 base/ply sheet, Type 15, 20, or 30 felt, or UL Classified prepared roofing accessory

Surfacing: One of the assemblies shown above in steel, fastened to 2 x 2 wood battens

Unlimited A C-15/32

Insulation (Optional): Any thickness Firestone ISO 95+ GL Insulation: Min. 1/2 in. ISOGARD HD Ply Sheet (Optional): One or more layers of Polystick MTS or Nova Seal Generation II Premium Roofing

underlayment Surfacing: One of the assemblies shown above in steel or copper

Page 9: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

9 | P a g e

J u n e 2 0 1 4

TABLE 1.01A (CONT.): UL External Fire Rated Assemblies

SYSTEM: METAL ROOFING ASSEMBLIES: UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, UC-750, UC-500, UC-501, UR, HR CONSTRUCTION: NEW, RETROFIT

Max. Slope: Class: Deck: Insulation Assembly:

Unlimited A C-15/32

Insulation (Optional): Firestone ISO 95+ GL Barrier Board:

1) Dens-Deck, min ¼ inch thick 2) UL Classified gypsum board, min. ½ inch thick 3) Min. one layer of Elk “Versashield”

Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing underlayment, WR Grace Ice and Water Shield, any UL Classified Type G1, G2, or G3 base/ply sheet, Type 15, 20, or 30 felt, or UL Classified prepared roofing accessory

Surfacing: One of the assemblies shown above in steel, copper, aluminum

Unlimited A C-15/32 or

Spaced Sheathing

Insulation (Optional): Firestone ISO 95+ GL, ISOGARD HD, or HailGard Underlayment: One layer ELK VersaShield Underlayment, MA Ply Sheet (Optional): One layers type 30 base sheet or VersaShield, MA Surfacing: One of the assemblies shown above in steel or copper

Unlimited A C-15/32 Insulation (Optional): Firestone ISO 95+ GL, ISOGARD HD, or HailGard Underlayment: One or more layers ELK VersaShield Underlayment, MA Surfacing: One of the assemblies shown above in aluminum

Unlimited A C-15/32 or

Spaced Sheathing

Insulation (Optional): Any thickness Firestone ISO 95+ GL, ISOGARD HD, or HailGard Underlayment: One or more layers ELK VersaShield Underlayment, MA Surfacing: One of the assemblies shown above in steel or copper

Unlimited A C-15/32 or

Spaced Sheathing

Insulation (Optional): Firestone ISO 95+ GL, ISOGARD HD, or HailGard Underlayment: One or more layers ELK VersaShield Underlayment, MA Surfacing: One of the assemblies shown above in steel, fastened to 2 x 2 wood battens

Unlimited A C-15/32

Insulation (Optional): Any thickness Firestone ISO 95+ GL Insulation: Firestone ½” ISOGARD HD Ply Sheet: One or more layers Polystick MTS or Nova Seal Generation II Premium Roofing underlayment Surfacing: One of the assemblies shown above in steel or copper

Unlimited A C-15/32 Underlayment: One layer of Elk “Versashield”, MA Surfacing: One of the assemblies shown above in steel, copper, or aluminum

Unlimited B Spaced

Sheathing Underlayment: One layer of Elk “Versashield”, MA Surfacing: One of the assemblies shown above in steel or copper

TABLE 1.01B

UL EXTERNAL FIRE RATED ASSEMBLIES SYSTEM: METAL ROOFING ASSEMBLIES: 5-V-Crimp CONSTRUCTION: NEW, RETROFIT

Max. Slope: Class: Deck: Insulation Assembly:

Unlimited A C-5/8 or Spaced

Sheathing

Underlayment: One layer of Elk “Versashield”, MA Insulation (Optional): Any thickness Firestone ISO 95+ GL, ISOGARD HD, or HailGard Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium

Roofing underlayment, WR Grace Ice and Water Shield, any UL Classified Type G1, G2, or G3 base/ply sheet, Type 15, 20, or 30 felt, or UL Classified prepared roofing accessory

Ply Sheet: One layer Type 30 base sheet or Elk “Versashield”, MA Surfacing: 5-V-Crimp

Unlimited A C-5/8 or Spaced

Sheathing

Insulation (Optional): Firestone ISO 95+ GL, ISOGARD HD, or HailGard Underlayment (Optional): One layer Elk VersaShield Underlayment, MA Ply Sheet: One layer Type 30 base sheet or Elk “Versashield”, MA Surfacing: 5-V-Crimp

Page 10: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

10 | P a g e

J u n e 2 0 1 4

1.02 Impact Resistance

1. Testing to UL 2218, “Impact Resistance of Prepared Roof Covering Materials”, results in Classifications for impact

resistance that are expressed as Class 1, 2, 3 or 4 which relate to a roof covering’s ability to withstand impacts from 1-1/4, 1-1/2, 1-3/4 and 2 inch diameter steel balls , respectively. The acceptance criteria to metal roof panels is as follows: withstand the assigned class designation impact without visible evidence of tearing, fracturing, cracking, splitting, rupturing, crazing or other opening of the roof covering layer. Classification is for metal panels placed over solid wood decking (3/8” or greater in thickness).

TABLE 1.02

UL IMPACT RESISTANCE RATED PANELS (ONLY STEEL, COPPER OR ALUMINUM , ANY THICKNESS)

Class 4 ratings were achieved for the following panels designations: UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14 UC-500, UC-501, UC-600, UC-601 5-V Crimp, UR, HR,VR

1.03 Wind Uplift Ratings - UL

1. Roof Deck Constructions Classified for Uplift Resistance have been tested to UL 580, “Tests for Uplift Resistance of

Roof Assemblies”. The UL 580 test method subjects a 10 ft. by 10 ft. test sample to various static and oscillating air pressures to index performance under uplift loads imposed on roof decks.

2. The nominal static uplift pressure, the oscillating uplift pressure and the maximum static uplift pressure for each

Class are:

TABLE 1.03A UL 580 TEST PRESSURES BY CLASS

Class Nominal Static Uplift Pressure (psf)

Range of Oscillating Pressure (psf) Maximum Static Uplift

Pressure (psf) 15 15 11 to 21 23 30 30 22 to 42 45 60 60 44 to 83 75 90 90 66 to 90 105

3. The static pressures are maintained for a 5 minute period and the oscillating pressures are applied at a 10 ± 2 second frequency and are maintained for a 60 minute period for each Class. An assembly rated Class 60 has successfully withstood pressures imposed during Class 30 and Class 60 tests. An assembly rated Class 90 has successfully withstood pressures imposed during Class 30, Class 60 and Class 90 tests.

Page 11: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

11 | P a g e

J u n e 2 0 1 4

ASSEMBLIES ARE UPDATED MARCH 2014. PLEASE UTILIZE THE UL WEBSITE TO VERIFY THE ASSEMBLY NUMBER ASSOCIATED TO EACH LISTED ASSEMBLY .

TABLE 1.03B

UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

UC-1 with UC-1 Batten Cover

Wood: Min. 5/8” nom (19/32” actual) thick plywood; Exposure 1, APA rated sheathing (42/20) square edged. Butt joints to be located over purlins, side joints not blocked. All butt and side joints to be sealed with a one part urethane caulk sealant-feathered outward from joint when alternate underlayment is not used. *1/2” nom (15/32” actual) thick plywood can be used with either steel or aluminum roofing panels when attaching the panel clips with a 10x1” PC T WOW T17 SS or the required length stainless steel fasteners based on the insulation thickness.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 15 or 30 organic felt, side laps min 2”, end laps per manufacturer's recommendations. When optional plywood is used, stapled with 5/16” long staples 6” o.c. side laps and 12” o.c. in two interior rows. As an alternate, a self-adhering modified bitumen water proofing membrane may be used. Installed per manufacturer's recommendations.

Width: Min. 12” Max. 17” Metal: Min. 24 ga Steel Min. .040” Alum Battens: Same type and thickness of the panels

Clips: Steel Panels: UC-1 Clip (Galvanized or Stainless Steel) Alum Panels: UC-1 Clip (Stainless Steel) Clip Spacing: 12”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Alum Panels: UC Bearing Plates (Stainless Steel) Fasteners: Steel Panels: Firestone 10x1” PC PD WOW T17 or Firestone 10x1” PC T WOW T17 SS Alum Panels: Firestone 10x1” PC T WOW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”. Two fasteners per clip.)

510A

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min. depth 1-1/2” Max. pitch 6” fabricated to various profiles.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 15 or 30 organic felt, side laps min 2”, end laps per manufacturer's recommendations. When optional plywood is used, stapled with 5/16” long staples 6” o.c. side laps and 12” o.c. in two interior rows. As an alternate, a self-adhering modified bitumen water proofing membrane may be used. Installed per manufacturer's recommendations.

Width: Min. 12” Max. 17” Metal: Min. 24 ga Steel Min. .040” Alum Battens: Same type and thickness of the panels

Clips: Steel Panels: UC-1 Clip (Galvanized or Stainless Steel) Alum Panels: UC-1 Clip (Stainless Steel) Clip Spacing: 12”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Alum Panels: UC Bearing Plates (Stainless Steel) Fasteners: Steel Panels: Firestone 12x2.25" PH PD WOW TK1 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

510

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 12: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

12 | P a g e

J u n e 2 0 1 4

TABLE 1.03B UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

UC-2 with UC-2 Batten Cover

Wood: Min. 5/8” nom (19/32” actual) thick plywood; Exposure 1, APA rated sheathing (42/20) square edged. Butt joints to be located over purlins, side joints not blocked. All butt and side joints to be sealed with a one part urethane caulk sealant-feathered outward from joint when alternate underlayment is not used. *1/2” nom (15/32” actual) thick plywood can be used with either steel or aluminum roofing panels when attaching the panel clips with a 10x1” PC T WOW T17 SS or the required length stainless steel fasteners based on the insulation thickness.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 15 or 30 organic felt, side laps min 2”, end laps per manufacturer's recommendations. When optional plywood is used, stapled with 5/16” long staples 6” o.c. side laps and 12” o.c. in two interior rows. As an alternate, a self-adhering modified bitumen water proofing membrane may be used. Installed per manufacturer's recommendations.

Width: Min. 12” Max. 17” Metal: Min. 24 ga Steel Min. .040” Alum Battens: Same type and thickness of the panels

Clips: Steel Panels: UC-2 Clip (Galvanized or Stainless Steel) Alum Panels: UC-2 Clip (Stainless Steel) Clip Spacing: 12”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Alum Panels: UC Bearing Plates (Stainless Steel) Fasteners: Steel Panels: Firestone 10x1” PC PD WOW T17 or Firestone 10x1” PC T WOW T17 SS Alum Panels: Firestone 10x1” PC T WOW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”. Two fasteners per clip.)

511A

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min. depth 1-1/2” Max. pitch 6” fabricated to various profiles.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 15 or 30 organic felt, side laps min 2”, end laps per manufacturer's recommendations. When optional plywood is used, stapled with 5/16” long staples 6” o.c. side laps and 12” o.c. in two interior rows. As an alternate, a self-adhering modified bitumen water proofing membrane may be used. Installed per manufacturer's recommendations.

Width: Min. 12” Max. 17” Metal: Min. 24 ga Steel Min. .040” Alum Battens: Same type and thickness of the panels

Clips: Steel Panels: UC-2 Clip (Galvanized or Stainless Steel) Alum Panels: UC-2 Clip (Stainless Steel) Clip Spacing: 12”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Alum Panels: UC Bearing Plates (Stainless Steel) Fasteners: Steel Panels: Firestone 12x2.25" PH PD WOW TK1 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

511

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 13: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

13 | P a g e

J u n e 2 0 1 4

TABLE 1.03B UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board

Insulation Underlayment Panel Type and Width Clips and/or Fasteners UL

Const. #

UC-3

Wood: Min. 5/8” nom (19/32” actual) thick plywood; Exposure 1, APA rated sheathing (42/20) square edged. Butt joints to be located over purlins, side joints not blocked. All butt and side joints to be sealed with a one part urethane caulk sealant-feathered outward from joint when alternate underlayment is not used. *1/2” nom (15/32” actual) thick plywood can be used with either steel or aluminum roofing panels when attaching the panel clips with a 10x1” PC T WOW T17 SS or the required length stainless steel fasteners based on the insulation thickness.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 15 or 30 organic felt, side laps min 2”, end laps per manufacturer's recommendations. When optional plywood is used, stapled with 5/16” long staples 6” o.c. side laps and 12” o.c. in two interior rows. As an alternate, a self-adhering modified bitumen water proofing membrane may be used. Installed per manufacturer's recommendations.

Width:

Min. 12” Max. 20” Metal: Min. 24 ga Steel Min. .032” Alum Seams: 1-1/2” High Double-Locked

Clips: Steel and Alum Panels: UC-3 Expansion Clip (Stainless Steel) Clip Spacing: 12”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Alum Panels: UC Bearing Plates (Stainless Steel) Fasteners: Steel Panels: Firestone 10x1” PC PD WOW T17 or Firestone 10x1” PC T WOW T17 SS Alum Panels: Firestone 10x1” PC T WOW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”. Two fasteners per clip.)

512A

Wood: Min. 5/8” nom (19/32” actual) thick CDX plywood. *1/2” nom (15/32” actual) thick plywood can be used with either steel or aluminum roofing panels when attaching the panel clips with a 10x1” PC T WOW T17 SS or the required length stainless steel fasteners based on the insulation thickness.

One layer Elk Versa Shield with 2” side lap, loose laid.

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Underlayment: One layer Type 30 organic felt with 2” side lap. Mechanically fastened to the plywood deck per manufacturer’s recommendations. Ventilation Mat: One layer Colbond "Enkamat 7010", loose laid.

Width: Max. 16” Metal: Min. 0.7mm zinc Seams: 1-1/2” High Double-Locked

Clips: Zinc Panels: UC-3 Super Clip (Stainless Steel) Clip Spacing: 12”o.c. max. Optional Bearing Plates: Zinc Panels: UC Bearing Plates (Stainless Steel) Fasteners: Zinc Panels: Firestone 10x1” PC T WOW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”. Two fasteners per clip.)

623

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 14: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

14 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment

Panel Type and Width Clips and/or Fasteners UL

Const. # UC-3

Wood: Min. 5/8” nom (19/32” actual) thick plywood; Grade B-C, APA rated. Fastened to supports (2 x 10 wood joists No. 2 or better, spaced 24 in o.c. max) using 8d by 2-1/2” long ring shank nails spaced 6 in. o.c. max at the butt ends and6 in. o.c. max. in the field. *1/2” nom (15/32” actual) thick plywood can be used with either steel or aluminum roofing panels when attaching the panel clips with a 10x1” PC T WOW T17 SS or the required length stainless steel fasteners based on the insulation thickness.

Optional Gypsum board: Max. 5/8” fastened to plywood with common fastener used for panel clip

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Optional: On top of insulation place a self-adhered modified bitumen installed per manufacture’s instructions

Width: Max. 20” Metal: Min. 24 ga steel Seams: 1-1/2” High Double-Locked

Clips: Steel Panels: UC-3 Expansion Clip (Stainless Steel) Clip Spacing: 24”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 12x2.25” PH PD WOW TK1 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”. Two fasteners per clip.)

656

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min. depth 1-1/2” Max. pitch 6” fabricated to various profiles.

One layer Elk Versa Shield with 2” side lap, loose laid.

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

One layer Type 30 organic felt with 2” side lap. Mechanically fastened to the deck per manufacturers recommendations.

Width: Max. 16” Metal: Min. 24 ga Steel Seams: 1-1/2” High Double-Locked

Clips: Steel Panels: UC-3 Super Clip (Galvanized Steel) Clip Spacing: 12”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 12x2.25” PH PD WOW TK1 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

622

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 15: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

15 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment

Panel Type and Width Clips and/or Fasteners UL

Const. # UC-3

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min. depth 1-1/2” Max. pitch 6” fabricated to various profiles.

Optional Dens Deck : Min. 1/4” directly over liner panel.

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Self-adhering modified bitumen water proofing membrane. Installed per manufacturer's recommendations.

Width: Min. 12” Max. 20” Metal: Min. 24 ga Steel Min. .032” Alum Seams: 1-1/2” High Double-Locked

Clips: Steel and Alum Panels: UC-3 Expansion Clip (Stainless Steel) Clip Spacing: 12”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Alum Panels: UC Bearing Plates (Stainless Steel) Fasteners: Steel Panels: Firestone 12x3.25” PH PD WOW TK1 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

512

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min. depth 1-1/2” Max. pitch 6” fabricated to various profiles.

One layer Elk Versa Shield with 2” side lap, loose laid.

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Underlayment: One layer Type 30 organic felt with 2” side lap. Mechanically fastened to the plywood deck per manufacturer’s recommendations. Ventilation Mat: One layer Colbond "Enkamat 7010", loose laid.

Width: Max. 16” Metal: Min. 0.7mm zinc Seams: 1-1/2” High Double-Locked

Clips: Zinc Panels: UC-3 Super Clip (Stainless Steel) Clip Spacing: 12”o.c. max. Optional Bearing Plates: Zinc Panels: UC Bearing Plates (Stainless Steel) Fasteners: Zinc Panels: Firestone 12x2.25” PH PD WOW TK1 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

624

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min. depth 1-1/2” Max. pitch 6” fabricated to various profiles. Fastened to max 6’ o.c. steel purlins 6” o.c.

Optional Gypsum board: Max 5/8” fastened to steel decking with common fastener used for panel clip

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Optional: On top of insulation place a self-adhered modified bitumen installed per manufacture’s instructions

Width: Max. 20” Metal: Min. 24 ga steel Seams: 1-1/2” High Double-Locked

Clips: Steel Panels: UC-3 Expansion Clip (Stainless Steel) Clip Spacing: 24”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 12x2.25” PH PD WOW TK1 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

658

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 16: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

16 | P a g e

J u n e 2 0 1 4

TABLE 1.03B TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

UC-3

Wood: Min. 5/8” nom (19/32” actual) thick plywood; Exposure 1, Grade B-C, APA rated sheathing conforming to requirements of DOC PS-1, with butt joints to be located over the wood supports (2 x 10 [1-1/2 x 9-1/8 actual] 42/20 square edged No. 2 grade or better S-P-F, Hemlock Fir, Douglas Fir or Southern Yellow Pine or equivalent. Spaced 24” o.c.).Plywood attached to joists with 8d x 2-1/2” long ring shank nails spaced 6” o.c. at edges and interior. *1/2” nom (15/32” actual) thick plywood can be used with either steel or aluminum roofing panels when attaching the panel clips with a 10x1” PC T WOW T17 SS or the required length stainless steel fasteners based on the insulation thickness.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 15 or 30 organic felt, side laps min. 2”, end laps per manufacturer’s recommendation

Width: Max. 16” Metal: Min. 24 ga steel Seams: 1-1/2”High Single-Locked

Clips: Steel Panels: UC-3 Expansion Clip (Stainless Steel) Clip Spacing: 18”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 10x1” PC PD WOW T17 or Firestone 10x1” PC T WOW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”. Two fasteners per clip.)

663

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 17: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

17 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment

Panel Type and Width Clips and/or Fasteners UL

Const. # UC-4

Wood: Min. 5/8” nom (19/32” actual) thick plywood; Exposure 1, APA rated sheathing (42/20) square edged. Butt joints to be located over purlins, side joints not blocked. All butt and side joints to be sealed with a one part urethane caulk sealant-feathered outward from joint when alternate underlayment is not used.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 15 or 30 organic felt, side laps min 2”, end laps per manufacturer's recommendations. When optional plywood is used, stapled with 5/16” long staples 6” o.c. side laps and 12” o.c. in two interior rows. As an alternate, a self-adhering modified bitumen water proofing membrane may be used. Installed per manufacturer's recommendations.

Width: Min. 12” Max. 18” Metal: Min. 24 ga Steel

Fastener Type: Steel Panels: Firestone 10x1” PC PD NW T17 or Firestone 10x1” PC T NW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”.) Fasteners Spacing: 18” o.c. with two fasteners used at each location driven through adjacent guide holes in mounting flange. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel)

376

Wood: Min. 3/4” nom (23/32” actual) thickness plywood; Exposure 1, APA rated sheathing (42/20) square edged. Butt joints to be located over purlins, side joints not blocked. All butt and side joints to be sealed with a one part urethane caulk sealant-feathered outward from joint when alternate underlayment is not used.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Rosin paper 9 mil thick. Side lap min. 3” stapled to insulation with random spacing. Type 15 or 30 organic felt, side laps min 2”, end laps per manufacturer's recommendations. Stapled to insulation with min 5/16” long staples 6” o.c. at side laps and 12” o.c. in two interior rows. As an alternate, a self-adhering modified bitumen water proofing membrane may be used. Installed per manufacturer's recommendations.

Width: Min. 12” Max. 14” Metal: Min. 16oz Copper

Fastener Type: Copper Panels: Firestone 10x1” PC T NW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”.) Fasteners Spacing: 9” o.c. with two fasteners used at each location driven through adjacent guide holes in mounting flange. Optional Bearing Plates: Copper Panels: UC Bearing Plates (Stainless Steel)

399

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 18: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

18 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment

Panel Type and Width Clips and/or Fasteners UL

Const. # UC-4

Wood: Min. 5/8” nom (19/32” actual) thick plywood; Exposure 1, APA rated sheathing (42/20) square edged. Butt joints to be located over purlins, side joints not blocked. All butt and side joints to be sealed with a one part urethane caulk sealant-feathered outward from joint when alternate underlayment is not used. *1/2” nom (15/32” actual) thick plywood can be used with either steel or aluminum roofing panels when attaching the panel clips with a 10x1” PC T WOW T17 SS or the required length stainless steel fasteners based on the insulation thickness.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 15 or 30 organic felt, side laps min 2”, end laps per manufacturer's recommendations. Stapled to insulation with min 5/16” long staples 6” o.c. at side laps and 12” o.c. in two interior rows As an alternate, a self-adhering modified bitumen water proofing membrane may be used. Installed per manufacturer's recommendations.

Width: Min. 12” Max. 17.75” Metal: Min. 24 ga Steel Min. .040” Alum

Fastener Type: Steel Panels: Firestone 10x1” PC PD NW T17 or Firestone 10x1” PC T NW T17 SS Alum Panels: Firestone 10x1” PC T NW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”.) Fasteners Spacing: 18” o.c. with two fasteners used at each location driven through adjacent guide holes in mounting flange. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Alum Panels: UC Bearing Plates (Stainless Steel)

513A

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min. depth 1-1/2” Max. pitch 6” fabricated to various profiles.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 15 or 30 organic felt, side laps min 2”, end laps per manufacturer's recommendations. When optional plywood is used, stapled with 5/16” long staples 6” o.c. side laps and 12” o.c. in two interior rows. As an alternate, a self-adhering modified bitumen water proofing membrane may be used. Installed per manufacturer's recommendations.

Width: Min. 12” Max. 18” Metal: Min. 24 ga Steel

Fastener Type: Steel Panels: Firestone 12x2.25” PH PD WOW TK1 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”.) Fasteners Spacing: 18” o.c. with two fasteners used at each location driven through adjacent guide holes in mounting flange. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel)

377

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 19: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

19 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment

Panel Type and Width Clips and/or Fasteners UL

Const. # UC-4

Wood: Min. nom 5/8” (19/32” actual) thick plywood; Grade B-C, APA rated. Fastened to supports (2 x 10 wood joists No. 2 or better, spaced 24” o.c. max.) using 8d by 2-1/2” long ring shank nails spaced 6” o.c. max at the butt ends and 6” o.c. max. in the field. As an alternate 7/16” thick PS-2 rated oriented strand board (OSB). Fastened to joists using No. 8 by 2-1/2” long coarse thread steel screws. Spaced 12” o.c. max. at the butt ends and 12” o.c. in the field. *1/2” nom (15/32” actual) thick plywood can be used with either steel or aluminum roofing panels when attaching the panel clips with a 10x1” PC T WOW T17 SS or the required length stainless steel fasteners based on the insulation thickness.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Optional: On top of insulation place a self-adhered modified bitumen installed per manufacture’s instructions

Width: Min. 9-3/4” Metal: Min. 26 ga Steel Min. .032” Alum

Fastener Type: Steel Panels: Firestone 10x1” PC PD NW T17 or Firestone 10x1” PC T NW T17 SS Alum Panels: Firestone 10x1” PC T NW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”.) Fasteners Spacing: 12” o.c. with two fasteners used at each location driven through adjacent guide holes in mounting flange. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Alum Panels: UC Bearing Plates (Stainless Steel)

657

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min depth 1-1/2” Max. pitch 6” fabricated to various profiles.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 15 or 30 organic felt, side laps min 2”, end laps per manufacturer's recommendations. When optional plywood is used, stapled with 5/16” long staples 6” o.c. side laps and 12” o.c. in two interior rows. As an alternate, a self-adhering modified bitumen water proofing membrane may be used. Installed per manufacturer's recommendations.

Width: Min. 12” Max. 17.75” Metal: Min. 24 ga Steel Min. .040” Alum

Fastener Type: Steel Panels: Firestone 12x2.25” PH PD WOW TK1 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”.) Fastener Spacing: 12“ o.c. with two fasteners used at each location driven through adjacent guide holes in mounting flange. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Alum Panels: UC Bearing Plates (Stainless Steel)

513

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 20: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

20 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

UC-4

Open Framing: 16 MSG min. thick coated steel Hat Channels 1” deep and 3-1/4” total width. Flanges, ¾” web, 1-3/4” (min. yield strength 33,000 psi). Spaced 18” o.c. hat channels fastened to purlins with 2 No. 12-14 by 3/4” self-drilling, self-tapping, hex-head plated steel screws.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Vapor Retarder: Min. 3 mil vinyl sheeting

Width: Min. 12” Max. 18” Metal: Min. 24 ga Steel

Fastener Type: Steel Panels: Firestone 14 X 1" HEX WOW TK3 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”.) Fasteners Spacing: 18” o.c. with two fasteners used at each location driven through adjacent guide holes in mounting flange. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel)

378

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

TABLE 1.03B (CONT.)

UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board

Insulation Underlayment Panel Type and Width Clips and/or Fasteners UL

Const. # UC-6

Wood: Min. 5/8” nom (19/32” actual) thick plywood; Grade B-C, APA rated. Fastened to supports (2 x 10 wood joists No. 2 or better, spaced 24 in o.c. max.) using 8d by 2-1/2” long ring shank nails spaced 6” o.c. max. at the butt ends and 6” o.c. max. in the field. *1/2” nom (15/32” actual) thick plywood can be used with aluminum roofing panels when attaching the panel clips with a 10x1” PC T WOW T17 SS or the required length stainless steel fasteners based on the insulation thickness.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

N/A

Width: Max. 18” Metal: Min. 24 ga Steel Min. .032” Alum Seams: 2” High Double-Locked

Clips: Steel Panels: UC-6 Low-Float Clip or UC-6 Super Clip (Galvanized or Stainless Steel) Alum Panels: UC-6 Low-Float Clip or UC-6 Super Clip (Stainless Steel) Clip Spacing: Steel Panels: 36” o.c. Alum Panels: 30” o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Alum Panels: UC Bearing Plates (Stainless Steel) Fasteners: Steel Panels: Firestone 12x2.25" PH PD WOW TK1 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”. Two fasteners per clip.)

655

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 21: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

21 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

UC-6

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min. depth 1-1/2” Max. pitch 6” fabricated to various profiles.

Optional Dens Deck : Min. 1/4” Directly over deck.

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Self-adhering modified bitumen water proofing membrane

Width: Max. 18” Metal: Min. 24 ga Steel Seams: 2” High Double-Locked

Clips: Steel Panels: UC-6 Low-Float Clip or UC-6 Super Clip (Galvanized or Stainless Steel) Clip Spacing: 30”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 2.875" AP Fastener (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”.)

652

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min. depth 1-1/2” Max. pitch 6” fabricated to various profiles.

Optional Dens Deck: Min. 1/4” Directly over deck.

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Self-adhering modified bitumen water proofing membrane

Width: Max. 18” Metal: Min. 24 ga Steel Min. .032” Alum Seams: 2” High Double-Locked

Clips: Steel Panels: UC-6 Low-Float Clip or UC-6 Super Clip (Galvanized or Stainless Steel) Alum Panels: UC-6 Low-Float Clip or UC-6 Super Clip (Stainless Steel) Clip Spacing: 24”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Alum Panels: UC Bearing Plates (Stainless Steel) Fasteners: Steel Panels: Firestone 10x1.5” PC PD WOW T17 or Firestone 10x1” PC T WOW T17 SS Alum Panels: Firestone 10x1” PC T WOW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

653

Open Framing: No. 16 MSG min. gauge steel (50,000 psi min. yield strength). Spacing to be max. 3’, 0” o.c.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

N/A

Width: Max. 16” Metal: Min. .040” Alum Seams: 2” High Double-Locked

Clips: Alum Panels: UC-6 Low-Float Clip or UC-6 Super Clip (Stainless Steel) Clip Spacing: 36”o.c. max. Optional Bearing Plates: Alum Panels: UC Bearing Plates (Stainless Steel) Fasteners: Alum Panels: Firestone 14x1” HEX WOW TK3 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

571A

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 22: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

22 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

UC- 6

Open Framing: No. 16 MSG min. gauge steel (50,000 psi min. yield strength). Spacing to be max. 4’, 0” o.c.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

N/A

Width: Max. 16” Metal: Min. 22ga Steel Seams: 2” High Double-Locked

Clips: Steel Panels: UC-6 Low-Float Clip or UC-6 Super Clip (Galvanized or Stainless Steel) Clip Spacing: 48”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 14x1” HEX WOW TK3 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

571

Open Framing: No. 16 MSG min. gauge steel (50,000 psi min. yield strength). Spacing to be max. 2’, 6” o.c.

N/A N/A N/A

Width:Min. 10” Max. 18” Metal: Min. 24 ga Steel Seams: 2” High Double-Locked

Clips: Steel Panels: UC-6 Hi-Float Clip (Galvanized) Clip Spacing: Steel Panels: 30” o.c. Fasteners: Steel Panels: Firestone 12x1.25" PH PD WOW TK3 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”. Two fasteners per clip.)

670

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

TABLE 1.03B (CONT.)

UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

UC-7 Wood: Min. 5/8” nom (19/32” actual) thick plywood; Grade B-C, APA rated. Fastened to supports (2 x 10 wood joists No. 2 or better, spaced 24” o.c. max.) using 8d by 2-1/2” long ring shank nails spaced 6” o.c. max. at the butt ends and 6” o.c. max. in the field. *1/2” nom (15/32” actual) thick plywood can be used with either steel or aluminum roofing panels when attaching the panel clips with a 10x1” PC T WOW T17 SS or the required length stainless steel fasteners based on the insulation thickness.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

N/A

Width: Max. 12” Metal: Min. 24 ga Steel

Clips: Steel Panels: UC-7 Clip (Galvanized or Stainless Steel) Clip Spacing: 12”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 10x1” PC PD WOW T17 or Firestone 10x1” PC T WOW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

660

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 23: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

23 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

UC-14

Wood: Min. 5/8”nom (19/32” actual) thick plywood decking to be graded per PS83 specifications,; Exposure 1, APA Rated Sheathing (42/20) square edged. Butt ends not blocked. All butt and side joints to be sealed with a one part urethane caulk sealant-feathered outward from joint when alternate underlayment is not used.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 15 or 30 organic felt As an alternate, a self-adhering modified bitumen water proofing membrane may be used.

Width: 18” Metal: Min. 24 ga Steel

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Clip Spacing: 36”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 10x1” PC PD WOW T17 or Firestone 10x1” PC T WOW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”. Two fasteners per clip.)

414

Wood: Min. 5/8”nom (19/32” actual) thick plywood decking or oriented strand board (OSB), exposure sheathing span C-D, 40/20 plywood. All butt and side joints to be sealed with a one part urethane caulk sealant-feathered outward from joint when alternate underlayment is not used. In lieu of plywood, 1 in. tongue and groove decking may be used.

Optional Dens Deck: Min. 1/4” Directly over deck.

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Optional: Any suitable membrane to protect deck.

Width: 18” Metal: Min. 24 ga Steel

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Clip Spacing: 48”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 10x1” PC PD WOW T17 or Firestone 10x1” PC T WOW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”. Two fasteners per clip.)

436

Wood: Min. 5/8”nom (19/32” actual) thick plywood decking. Rated per PS-1 specification. Butt ends not blocked. *1/2” nom (15/32” actual) thick plywood can be used with either steel or aluminum roofing panels when attaching the panel clips with a 10x1” PC T WOW T17 SS or the required length stainless steel fasteners based on the insulation thickness.

Optional Dens Deck: Min. 1/4” Directly over deck.

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 30 organic felt. Sides overlapped min 2”, end laps per manufacturer's instructions. Felt nailed to plywood deck with 1” long galvanized steel roofing nails, located per manufacturer's instructions. Nail spacing to be max. 12” o.c. at the side lap and max 24” o.c. in interior rows.

Width: 16” Metal: Min. .032” Alum

Clips: Alum Panel: UC-14 Clip (Stainless Steel) Clip Spacing: 18”o.c. max. Optional Bearing Plates: Alum Panels: UC Bearing Plates (Stainless Steel) Fasteners: Alum Panel: Firestone 10x1” PC T WOW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1”. Two fasteners per clip.)

508

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 24: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

24 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

UC-14

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min. depth 1-1/2” Max. pitch 6” fabricated to various profiles.

Optional: Min 5/8” gypsum, 4’x8’ sheets, directly over liner panel.

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 30 organic felt. As an alternate, a self-adhering modified bitumen water proofing membrane may be used.

Width: Min. 10” Max. 18” Metal: Min. 24 ga Steel

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Clip Spacing: 48”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panel: Firestone 2.875" AP Fastener (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

303

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min. depth 1-1/2” Max. pitch 6” fabricated to various profiles.

Optional: Min 5/8” gypsum, 4’x8’ sheets, directly over liner panel.

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Self-adhering modified bitumen water proofing membrane

Width: Max. 18” Metal: Min. 24 ga Steel

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Clip Spacing: 48”o.c. max. Optiona Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panel: Firestone 2.875" AP Fastener (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)l

448

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min. depth 1-1/2” Max. pitch 6” fabricated to various profiles.

Optional Gypsum board: Max 5/8”, 4’x8’ sheets fastened to steel decking with common fastener used for panel clip

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Type 30 organic felt. Sides overlapped min 2”. end laps per manufacturer's instructions. Felt nailed to nailable insulation with 1” long galvanized steel roofing nails, located in side laps and between side laps per manufacturer's instructions. Nail spacing to be max. 12” o.c. at the side lap and max. 24” o.c. in interior rows.

Width: Steel - 18”, 16”, 12”, 10” Alum – 16”, 12”, 10” Metal: Min. 24 ga Steel Min. .032” Alum

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Alum Panel: UC-14 Clip (Stainless Steel) Clip Spacing: Steel Panels: 36”o.c. max. Alum Panels: 18”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 10x1” PC PD WOW T17 or Firestone 10x1” PC T WOW T17 SS Alum Panels: Firestone 10x1” PC T WOW T17 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

508A

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 25: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

25 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

UC-14

Steel: No. 22 MSG min. thick coated steel (min. yield strength 33,000 psi). Min. depth 1-1/2” Max. pitch 6” fabricated to various profiles. Fastened to supports 6” o.c. Purlins(joists) 6’ o.c.

N/A

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

N/A

Width: Max. 18” Metal: Min. 24 ga Steel Min. .032” Alum

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Alum Panel: UC-14 Clip (Stainless Steel) Clip Spacing: Steel Panels: 18”o.c. max. Alum Panels: 12” o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Alum Panels: UC Bearing Plates (Stainless Steel) Fasteners: Steel Panels: Firestone 12x2.25” PH PD WOW TK1 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

664

Loadmaster System: N/A

Insulation: Min 1.0” Firestone ISO95+ GL, 4’x8’ sheets, All end joints to be staggered with respect to adjacent rows. All joints to be offset from joints in mineral board. ½” Min. Dura flex Mineral Board . Joints taped with 2-1/2” wide taped supplied by manufacture. (See UL Roof Deck Construction for special attachment)

Vapor Barrier: Single ply used between Fire Barrier and the metal roof deck panels.

Width: Min. 10” Max. 18” Metal: Min. 24 ga Steel

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Clip Spacing: 48”o.c. max. Fasteners: Steel Panels: (0.140” dia. threaded shank Phillips, bugle or trumpet head, self-drilling, self-tapping corrosion resistant coated steel screws supplied by roof deck manufacturer. If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1/2”. Two fasteners per clip.)

342

Loadmaster System: N/A

Insulation: Min 1.0” Firestone ISO95+ GL, 4’x8’ sheets, All end joints to be staggered with respect to adjacent rows. All joints to be offset from joints in mineral board. Thermal Board: Dens Deck, Dens Deck Prime, or Duraflex Mineral Board : 1/2” Min. thick. Joints taped with 2-1/2” wide taped supplied by manufacture. (See UL Roof Deck Construction for special attachment)

Vapor Barrier: Single ply used between Fire Barrier and the metal roof deck panels.

Width: Max. 18” Metal: Min. 24 ga Steel

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Clip Spacing: 48”o.c. max. Fasteners: Steel Panels: Firestone All-Purpose (AP) Fastener. (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1/2”. Two fasteners per clip.)

486

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 26: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

26 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

UC-14

Open Framing: No. 16 MSG min. thick steel (min. yield 50 ksi). A) 60” purlin spacing for 22ga steel panels. B) 48” purlin spacing for 24ga steel panels.

N/A

Optional: Max. 4” Compliant with ASTM C1289 or ASTM C578 Standards, Types IV, X or XII. Located over purlins. Density to be min. 1.8 pcf. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

N/A

Width: 12” Metal: Min. 24 ga Steel

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Clip Spacing: One clip at each purlin Optional Bearing Plate: Min. 16ga steel, 4”x5” Fasteners: Steel Panels: Firestone 10x1” PC PD WOW TK3 or 12 X 1.25" PH PD WOW TK3 SS (No. 14-13 DP1 carbon, pancake head combination Square/Phillips Drive screws to be used when insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

254

Open Framing: No. 16 MSG min. thick steel (min. yield 50 ksi). A) 48” purlin spacing for Class 90 rating. B) 60” purlin spacing for Class 60 rating.

N/A

Optional: Max. 4” Compliant with ASTM C1289 or ASTM C578 Standards, Types IV, X or XII. Located over purlins. Density to be min. 1.8 pcf. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

N/A

Width: Min. 10” Max. 18” Metal: Min. 24 ga Steel

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Clip Spacing: One clip at each purlin Optional Bearing Plate: Min. 16ga steel, 4”x5” Fasteners: Steel Panels: Firestone 10x1” PC PD WOW TK3 or 12 X 1.25" PH PD WOW TK3 SS (No. 14-13 DP1 carbon, pancake head combination Square/Phillips Drive screws to be used when insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

255

Open Framing: No. 16 MSG min. thick steel (min. yield 50 ksi). A) 36” purlin spacing for Class 90 rating for aluminum panels. B) 48” purlin spacing for Class 60 rating for aluminum panels. C) 60” purlin spacing for class 90 rating for No. 22ga steel panels. D) 48” purlin spacing for Class 60 rating for No. 24ga steel panels.

N/A

Optional: Max. 4” Compliant with ASTM C1289 or ASTM C578 Standards, Types IV, X or XII. Located over purlins. Density to be min. 1.8 pcf. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

N/A

Width: 10.5” Metal: Min. 24 ga Steel Min. .032” Alum

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Alum Panel: UC-14 Clip (Stainless Steel) Clip Spacing: One clip at each purlin Optional Bearing Plate: Min. 16ga steel, 4”x5” Fasteners: Steel Panels: Firestone 10x1” PC PD WOW TK3 or 12 X 1.25" PH PD WOW TK3 SS Alum Panels: Firestone 12 X 1.25" PH PD WOW TK3 SS (No. 14-13 DP1 carbon, pancake head combination Square/Phillips Drive screws to be used when insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

261

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 27: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

27 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

UC-14

Open Framing: No. 16 MSG min. thick steel (min. yield 50 ksi). A) 60” purlin spacing for No. 22 MSG panels. B) 48” purlin spacing for No. 24 MSG panels.

N/A

Optional: Vinyl faced blanket insulation, 3” thick when located between panels and purlins. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

N/A

Width: 12” Metal: Min. 24 ga Steel

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Clip Spacing: One clip at each purlin Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 10x1” PC PD WOW TK3 or 12 X 1.25" PH PD WOW TK3 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

445

Open Framing: No. 16 MSG min. thick steel (min. yield 50 ksi) A) 48” purlin spacing for No. 24 MSG panels.

N/A

Optional: Vinyl faced blanket insulation, 3” thick or ¼” thick closed/microcellular polyethylene insulation with foil facing designated "Low-E Insulation™, located between panels and purlins. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

N/A

Width: 18” Metal: Min. 24 ga Steel

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Clip Spacing: One clip at each purlin Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 10x1” PC PD WOW TK3 or 12 X 1.25" PH PD WOW TK3 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

446

Open Framing: No. 16 MSG min. thick steel (min. yield 50 ksi). A) 36” purlin spacing for 0.032” aluminum panels. B) 60” purlin spacing for No. 22 MSG panels. C) 48” purlin spacing for No. 24 MSG panels.

N/A

Optional: Vinyl faced blanket insulation, 3” thick when located between panels and purlins. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

N/A

Width: 10” Metal: Min. 24 ga Steel Min. .032” Alum

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Alum Panel: UC-14 Clip (Stainless Steel) Clip Spacing: One clip at each purlin Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Alum Panels: UC Bearing Plates (Stainless Steel) Fasteners: Steel Panels: Firestone 10x1” PC PD WOW TK3 or 12 X 1.25" PH PD WOW TK3 SS Alum Panels: Firestone 12 X 1.25" PH PD WOW TK3 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

447

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 28: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

28 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

UC-14 Open Framing: No. 16 MSG min. thick steel (min. yield strength of 50,000 psi) A) 48” purlin spacing for Class 90 rating for No. 24 MSG panels in all widths. B) 60” purlin spacing for Class 90 rating for No. 22 MSG 12” wide panels only. C) 60” purlin spacing for class 60 rating for No. 22 MSG panels in all widths.

N/A

Any compressible blanket insulation, 3” max. thick when located between panels and purlins. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

N/A

Width: Max. 18” Metal: Min. 24 ga Steel

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Clip Spacing: One clip at each purlin Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 10x1” PC PD WOW TK3 or 12 X 1.25" PH PD WOW TK3 SS (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 3/4”. Two fasteners per clip.)

543

Open Framing: No. 16 MSG min. thick coated steel purlins (min. yield strength of 50,000 psi.) Or min. "H" series open-web joists. Max. spacing 48" o.c. Optional Steel Deck: No. 29 MSG min. steel. (min. yield strength 80,000 psi), min. depth 9/16”, max. pitch 2.6667” o.c.

See UL Roof Deck Const.

Optional ISO 95+GL, RESISTA or ISOGARD HD: Applied flat or tapered in any combination as long as ISOGARD HD is the top layer when used, joints staggered between layers, to a maximum 10” in total thickness. Optional Coverboard : **As an alternate to the bearing plates, min. 1/2" nom (15/32” actual) plywood, DOC PS-1 rated or min. 7/16” OSB, DOC PS-2 rated or min. 1/4” G-P gypsum “DensDeck” may be used.

Any suitable membrane to protect Insulation and Coverboard

Width: Max. 18” Metal: Min. 24 ga Steel

Clips: Steel Panel: UC-14 Clip (Galvanized or Stainless Steel) Clip Spacing: 48”o.c. max. Optional Bearing Plates: Steel Panels: UC Bearing Plates (Galvanized or Stainless Steel) Fasteners: Steel Panels: Firestone 14x1” HEX WOW TK3 (If insulation is used, the clip fasteners must be long enough to penetrate the roof deck by 1/2”. Two fasteners per clip.)

544

TABLE 1.03B

UL 580, CLASS 90 RATED ROOF DECK CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners UL Const. #

5V Crimp

Wood: Min. 5/8”, Type CDX APA Rated plywood sheathing.

One layer Elk Versa Shield with 2” side lap, loose laid.

N/A

One layer of Type 30, fastened per manufacturer's installation instructions.

Width: Max. 22.5” Metal: Min. 26 ga Steel

Fastener: Steel Panels: Firestone 9x1.5” HEX SW PP (Color) Fastener Spacing: 24” o.c.. and located on the top part of the panel 5V-Crimp.

629

*When plywood or OSB are used for a coverboard and the panel or panel clips are going to be attached to the coverboard; The fasteners used to attach the coverboard to deck are to be Firestone HD HailGard Fasteners in a pattern of 24 screws per 4’ by 8’ coverboard. The panel or panel clip fasteners will need to be a Firestone 10x1” PC T WOW T17 SS. **When Dens Deck is used for the coverboard; Please contact a Roof System Advisor for the fastening rate of the coverboard. The panel or panel clip fasteners will need to be long enough to penetrate the roof deck by the required length based on roof deck material type.

Page 29: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

29 | P a g e

J u n e 2 0 1 4

4. UL 1897 Testing: Test is conducted in accordance with UL 1897 “Uplift Test for Roof Covering Systems”. The test method subjects a minimum 10 ft by 10 ft sample to various short term (one minute increments) static air pressure to index performance under uplift loads imposed on a roofing system’s securement to a specified roof deck.

ASSEMBLIES ARE UPDATED MARCH 2014. PLEASE UTILIZE THE UL WEBSITE TO VERIFY THE ASSEMBLY NUMBER ASSOCIATED TO EACH

LISTED ASSEMBLY .

TABLE 1.03C UL 1897 TESTED ROOF CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners Wind Uplift

UC-3

Steel: Min. No. 22 MSG

N/A

Foamed Plastic (Rigid Insulation): Min. 1”, max. 4” thickness. Joints staggered between layers. Mechanically fastened to the steel deck per manufacturer’s recommendation.

Underlayment #1: One layer Type 30 organic felt with 2” side laps. Mechanically fastened to the steel deck per manufacturers recommendations. Underlayment #2: One layer UL Classified ELK “VersaShield” with 2” side laps, loose laid.

Width: Max. 16” With 1-1/2” high legs Metal: Min. No. 24 MSG coated steel. Panels must be continuous over three or more clips with no end laps. Panel ribs seamed with an electric seaming tool with seaming operation to include upper tabs of panel clips. Identified as “UC-3”.

Clips: UC-3 Expansion Clip Two part assembly, base 5” long, 1” wide, 0.42” high. Fabricated from No. 22 MSG min. thick coated steel. Upper tab 3” long, 0.42” wide, 1.786” high. Fabricated from No. 24 MSG min. thick coated steel. Clip Spacing: 12” o.c. max. Bearing Plates: Plates used with panel screw fasteners under panel to be 4” by 4” min. 26 gauge stainless steel. As an alternate, 1/2” thick (15/32” actual) plywood, APA rated sheathing, square edged may be used. Fasteners: Fasteners used to attach panel clips to steel deck to be No. 12 pancake wafer head steel screws. Length to penetrate steel deck a min. 3/4”. Two fasteners used per clip.

-142 PSF

Plywood: Min. 5/8” nom (19/32” actual) thick plywood; Exposure 1, Grade B-C, APA rated sheathing, conforming to requirements of DOC PS-1, with butt joints to be located over wood supports (joist). Fastened to supports with 8d x 2-1/2” long ring shank nails spaced 6” o.c. at butted ends and 6” o.c. in the field.

N/A N/A

Underlayment: One layer Type 15 or 30 organic felt with 2” side lap. Fastened to the plywood deck per manufacturer’s recommendations.

Width: Max. 16” With 1-1/2” high legs. Metal: Min. No. 24 MSG coated steel. Panel ribs single seamed. Identified as “UC-3”.

Clips: UC-3 Expansion Clip Two part assembly, base 5” long, 1” wide, 0.42” high. Fabricated from min. 0.0225” thick 304 stainless steel. Upper tab 3” long, 0.42” wide, 1.786” high. Fabricated from min. 0.0172” thick 304 stainless steel. Clip Spacing: 18” o.c. max. Fasteners: Fasteners used to attach panel clips to plywood deck to be No. 10x1” long pancake head screws. Two screws used per clip.

-157 PSF

Page 30: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

30 | P a g e

J u n e 2 0 1 4

TABLE 1.03B (CONT.) UL 1897 TESTED ROOF CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners Wind Uplift

UC-3

Steel: Min. No. 22 MSG

N/A

Foamed Plastic (Rigid Insulation): Min. 1”, max. 4” thickness. Joints staggered between layers. Mechanically fastened to the steel deck per manufacturer’s recommendation.

Underlayment #1: One layer Type 30 organic felt with 2” side laps. Mechanically fastened to the steel deck per manufacturers recommendations. Underlayment #2: One layer UL Classified ELK “VersaShield” with 2” side laps, loose laid. Vapor Barrier: One layer Colbond “Enkamat 7010”, loose laid.

Width: Max. 16” With 1-1/2” high legs Metal: Min. 0.027” RHEINZINK Panels continuous over three or more clips with no end laps. Panels ribs double seamed with and electric seaming tool with seaming operation to include upper tabs of panel clips. Identified as “UC-3”.

Clips: UC-3 Expansion Clip Two part assembly, base 5” long, 1” wide, 0.42” high. Fabricated from min. 0.0225” thick 304 stainless steel. Upper tab 3” long, 0.42” wide, 1.786” high. Fabricated from min. 0.0172” thick 304 stainless steel. Clip Spacing: 12” o.c. max. Bearing Plates: Plates used with panel screw fasteners under panel to be 4” by 4” min. 26 gauge stainless steel. As an alternate, 1/2” thick (15/32” actual) plywood, APA rated sheathing, square edged may be used. Fasteners: Fasteners used to attach panel clips to steel deck to be No. 12 pancake wafer head steel screws. Length to penetrate steel deck a minimum 3/4”. Two screws used per clip.

-187 PSF

Plywood: Min 19/32” thick CDX

N/A N/A

Underlayment #1: One layer Type 30 organic felt with 2” side lap. Fastened to the plywood deck per manufacturer’s recommendations. Underlayment #2: One layer UL Classified Elk “VersaShield” with 2” side lap, loose laid. Vapor Barrier: One layer of Colbond “Enkamat 7010”, loose laid

Width: Max. 16” With 1-1/2” high legs Metal: Min. 0.027” RHEINZINK Panels continuous over three or more clips with no end laps. Panels ribs double seamed with and electric seaming tool with seaming operation to include upper tabs of panel clips. Identified as “UC-3”.

Clips: UC-3 Expansion Clip Two part assembly, base 5” long, 1” wide, 0.42” high. Fabricated from min. 0.0225” thick 304 stainless steel. Upper tab 3” long, 0.42” wide, 1.786” high. Fabricated from min. 0.0172” thick 304 stainless steel. Clip Spacing: 12” o.c. max. Fasteners: Fasteners used to attach panel clips to plywood deck to be No. 10x1-1/2” long pancake head stainless steel screws. Two screws used per clip.

-247 PSF

Plywood: Min. 5/8” nom (19/32” actual) thick plywood; Exposure 1, Grade B-C, APA rated sheathing, conforming to requirements of DOC PS-1, with butt joints to be located over wood supports (joist). Fastened to supports with 8d x 2-1/2” long ring shank nails spaced 6” o.c. at butted ends and 6” o.c. in the field.

N/A N/A

Underlayment: One layer Type 30 organic felt with 2” side lap. Fastened to the plywood deck per manufacturer’s recommendations.

Width: Max. 16” With 1-1/2” high legs Metal: Min. No. 24 MSG coated steel. Panel ribs single seamed. Identified as “UC-3”.

Clips:UC-3 Expansion Clip Two part assembly, base 5” long, 1” wide, 0.42” high. Fabricated from min. 0.0225” thick 304 stainless steel. Upper tab 3” long, 0.42” wide, 1.786” high. Fabricated from min. 0.0172” thick 304 stainless steel. Clip Spacing: 8” o.c. max. Fasteners: Fasteners used to attach panel clips to plywood deck to be No. 10x1” long pancake head screws. Two screws used per clip.

-202 PSF

Page 31: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

31 | P a g e

J u n e 2 0 1 4

TABLE 1.03C UL 1897 TESTED ROOF CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners Wind Uplift

UC-4

Plywood: Min. 19/32” thick APA rated sheathing Grade B-C fastened to supports with 8d x 2-1/2” long ring shank nails spaced 6” o.c.

N/A N/A N/A

Width:Max. 9-3/4” With 1-1/2” high legs Metal: Min. No. 26 MSG Coated steel or Min. 0.032” Alum Panel ribs single seamed. A bead of sealant may be used at panel ribs. Identified as “UC-4”.

Fasteners: Fasteners used to attach panel to plywood deck to be No. 10x1” long pancake head screws. Fastener Spacing: 12“ o.c. with two fasteners used at each location.

-247 PSF

Plywood: Min. 19/32” thick APA rated sheathing Grade B-C fastened to supports with 8d x 2-1/2” long ring shank nails spaced 12” o.c. in the field and 6” o.c. along the perimeter.

N/A N/A N/A

Width:Max. 9-3/4” With 1-1/2” high legs Metal: Min. No. 26 MSG Coated steel or Min. 0.032” Alum Panel ribs single seamed. A bead of sealant may be used at panel ribs. Identified as “UC-4”.

Fasteners: Fasteners used to attach panel to plywood deck to be No. 10x1” long pancake head screws. Fastener Spacing: 12“ o.c. with two fasteners used at each location.

-217 PSF

TABLE 1.03C

UL 1897 TESTED ROOF CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type and

Width Clips and/or Fasteners Wind Uplift

UC-6

Supports (Purlins): No. 16 MSG steel (50ksi yield strength) spaced max 3’-0” o.c.

N/A N/A N/A

Width:Max. 16” With 2” high female leg and 1-3/4” male leg Metal : Min. .040” Alum Panels continuous over two or more spans. Panels seamed 180º at ribs with an electric seamer.

Clips: UC-6 Clip Two part assembly. Located over panel sides, fastened to supports using two fasteners per clip. Fasteners: Used to attach panel clips to purlins, No. 1/4-14x7/8” long , self-drilling, self-taping, hex-head steel. Two screws used per clip.

-165 PSF

Page 32: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

32 | P a g e

J u n e 2 0 1 4

TABLE 1.03C UL 1897 TESTED ROOF CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners Wind Uplift

UC-7

Plywood: Min. 5/8” APA rated sheathing Grade B-C fastened to supports with No. 8d by 2-1/2” long steel ring shank nails spaced 6” o.c. in the field and 6” o.c. along the perimeter

N/A N/A N/A

Width:Max. 12” With Max. 1” high legs Metal : Min. No. 24 MSG A bead of sealant may be used at panel ribs.

Clips: UC-7 Clip One piece assembly spaced. Clip Spacing: 12” o.c. max. Fasteners: Used to attach panel clips to deck, No. 12x1” long steel screws. Two screws used per clip.

-120 PSF

TABLE 1.03C

UL 1897 TESTED ROOF CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners Wind Uplift

UC-14

Steel : Min. No. 22 MSG

N/A

Optional Foamed Plastic (Rigid Insulation): Max. 4” thickness. Joints staggered between layers.

N/A

Width: Max. 18” With 1-3/4” high legs Metal : Min. No. 24 MSG coated steel or Min. 0.032 Alum A bead of sealant may be used at panel side joints.

Clips: UC-14 Clip Clip Spacing: 18” o.c. max. Bearing Plates: Plates used with panel screw fasteners under panel to be 4” by 4” min. 26 gauge stainless steel. Bearing plate optional if insulation is not used. Fasteners: Fasteners used to attach panel clips to steel deck to be No. 12 pancake wafer head steel screws. Length to penetrate steel deck a minimum 1/2” Two screws used per clip.

-105 PSF

TABLE 1.03C

UL 1897 TESTED ROOF CONSTRUCTIONS

Deck Thermal Board Insulation Underlayment Panel Type

and Width Clips and/or Fasteners Wind Uplift

5V-Crimp

Plywood: Min. 5/8” thick CDX N/A N/A

Underlayment #1: One layer Type 30 organic felt with 2” side lap. Fastened to the plywood deck per manufacturer’s recommendations. Underlayment #2: One layer UL Classified Elk “VersaShield” with 2 in. side lap, loose laid.

Roof Panels: “5-V-Crimp” panel. 0.172 in. min thickness steel. Panel width 22-1/2 in. Width: Max. 22-1/2” Metal : Min. 0.172” Steel A bead of sealant may be used at panel side joints.

Fasteners: No. 9x1-1/2” long hex head steel screws with a bonded washer. Fastener Spacing: 24“ o.c. and located on the top part of the panel v-crimp.

-155 PSF

Page 33: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

33 | P a g e

J u n e 2 0 1 4

1.04 Internal Fire (“P” Assemblies)

1. The following panel designations can be used in Design Nos.: P225, P227, P230, P237, P259, P508, P510, P512,

P514, P518, P701, P711, P717, P720, P722, P723, P726, P731, P734, P736, P801, P815, P819:

A. Mechanically Attached Metal Roof Panels – Type UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-500, UC-501, UC-600, UC-601, UR, HR, and VR roof panels (26 MSG min gauge coated steel, min 0.020 in. thick copper or 0.032 min. gauge coated aluminum) placed over specified insulation and/or roof covering for the respective designs. Panel secured to top layer of 7/16 in. APA-rated oriented strand board (OSB) laminated to rigid insulation or 5/8 in. plywood over rigid insulation. Refer to individual Roof-Ceiling design under the appropriate Building Unit item for name of Classified Companies. Panels secured to oriented strand board or plywood at side ribs with panel clips designed specifically for these panels. Panel clips spaced 18 in. oc using No. 12-15 No. 3 Phillips self-drilling, self-tapping truss head steel or stainless steel screw. Zinc plated carbon steel screws. The oriented strand board laminated insulation or plywood covered rigid insulation are mechanically fastened to steel roof deck and covered with a 30 lb. felt.

B. Mechanically Attached Metal Roof Panels – Type UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-500, UC-

501, UC-600, UC-601, UR, HR, and VR roof panels (26 MSG min gauge coated steel, min 0.020 in. thick copper or 0.032 min. gauge coated aluminum) placed over specified insulation and/or roof covering for the respective designs.

2. Type UC-1, UC-2, UC-3, UC-4, UC-6, and UC-7 are secured by their panel clips with the upper portion of the clip

engaging the panel rib, a 3 in. by 4 in. bearing plate fabricated of nominal 0.018 in. thick coated steel is used under each panel clip. The bearing plate shall be placed over the specified roof insulation. The fastener shall penetrate the roof deck a min of ½ in. and shall be spaced 18 in. OC.

3. Type UC-500, UC501, UC-600, UC-601, UR, HR, and VR are screwed into the top of the panel rib through the metal

panels into the specified insulation. Panel clips are attached using No. 12-15 Phillips drive truss head steel or stainless steel screw with a “S” point or tek point. Two fasteners per clip are used. The fasteners shall penetrate the roof deck a min. of ½ in. and shall be spaced 18 in. OC.

1.05 STATE OF FLORIDA and MIAMI-DADE APPROVALS TABLE 1.05A

STATE OF FLORIDA PRODUCT APPROVAL Specific State of Florida Product Approvals can be viewed by going to www.floridabuildingcode.org/

FL Product Approval Number Firestone Metal Products Profile Type of Metal

FL 13629 UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, 5-V-Crimp See specific product approval

FL 11299-R0 UC-500 See specific product approval FL 2833-R2 UC-6 See specific product approval

NOTE: Florida Product Approval Numbers FL 175-02, FL 2833-R1, FL 3570-R1, FL 4193-R1, FL 5292-R1, and FL 10601-R2 are consolidated under FL 13629.

TABLE 1.05B

MIAMI-DADE NOTICE OF ACCEPTANCE Specific Miami-Dade Notice of Acceptance (NOA) can be viewed by going to www.miamidade.gov/buildingcode/

Miami-Dade NOA# Firestone Metal Products Profile: Roof System: 10-1214.09 UC-3 24 ga Rheinzink, WD, NI 10-1214.10 UC-3 24 ga Rheinzink, 22 ga steel deck, insulated 10-1214.01 5-V-Crimp Min. 26ga Steel, WD, NI 10-1214.02 UC-3 Min. 0.032” Aluminum, WD, NI 11-0210.02 UC-3 24 ga. Steel, 22 ga steel deck, insulated 10-1214.12 UC-3 .040 Alum., 22 ga steel deck, insulated 07-0822.02 UC-6 Steel, large & small Impact rated 10-1214.06 UC-3 Min. 16oz Copper, WD, NI 10-1214.08 UC-3 Min. 24ga Steel, WD, NI 10-1214.03 UC-4 Min. 24ga Steel, WD, NI 10-1214.07 UC-14 Min. 24ga Steel, WD, NI 09-0219.02 UC-4 Min. 0.032 Aluminum 11-0210.02 UC-3 24 ga Galvalume or Galvanized Steel, 0.0235 min.

Notes: See specific Miami-Dade NOA for the maximum pressure allowed for all areas of the roof WD = wood deck, 19/32” or greater NI = non-insulated

Page 34: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

34 | P a g e

J u n e 2 0 1 4

TABLE 1.05C FLORIDA BUILDING CODE (HVHZ)

TAS 100-95 (WIND DRIVEN RAIN TEST) Model Underlayment Fire Barrier Water Entry Panel Uplift Wind Speed Pass/Fail UC-3, 24 ga.,

w/ 12” oc, 1-1/2” ribs

ASTM D226, Type II (30# felt) Elk VersaShield No Entry No Uplift 110 mph Pass

UC-4, 24 ga.,

w/ 11-3/4” oc, 1-1/2” ribs

ASTM D226, Type II (30# felt) Elk VersaShield No Entry No Uplift 110 mph Pass

UC-6, 24 ga.,

w/ 12” oc, 2” ribs

ASTM D226, Type II (30# felt) Elk VersaShield No Entry No Uplift 110 mph Pass

UC-14, 24 ga., w/ 12” oc, 1-3/4”

ribs

ASTM D226, Type II (30# felt) Elk VersaShield No Entry No Uplift 110 mph Pass

TABLE 1.05D

FLORIDA BUILDING CODE (HVHZ) TAS 125

Model Underlayment Fire Barrier Uplift UC-3 – 24ga steel, 16” wide panels,

continuous clip of 22ga steel attached 6”oc with #12 x 1-1/4” pancake screws

into 5/8” plywood

30# asphalt saturated felt , ASTM D226, Type II, 6”oc 0.120” x 1-1/4” galvanized

annular ring shank nails with32 ga tin caps in the perimeter,

12”oc in the field

VersaShield, loose laid -408.5 psf test pressure

1.06 Energy Star Approvals - As Currently Listed at www.energystar.gov

TABLE 1.06

ENERGY STAR APPROVALS

Color Models Initial Solar Reflectance

Solar Reflectance after 3 years

Almond SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.57 0.56

Bone White SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.72 0.7

Brandywine SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.25 0.23

Champagne Metallic SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.37 0.36

Charcoal Gray SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.29 0.28

Cityscape SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.35 0.34

Classic Copper SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.42 0.40

Colonial Red SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.31 0.31

Dark Bronze SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.26 0.25

Page 35: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

35 | P a g e

J u n e 2 0 1 4

TABLE 1.06 ENERGY STAR APPROVALS

Color Models Initial Solar Reflectance

Solar Reflectance after 3 years

Dark Ivy SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.25 0.25

Hemlock Green SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.32 0.29

Mansard Brown SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.30 0.29

Matte Black SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.25 0.27

Medium Bronze SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.30 0.28

Patina Green SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.26 0.28

Regal Red SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.42 0.41

Sandstone SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.51 0.50

Sherwood Green SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.27 0.26

Sierra Tan SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.35 0.34

Silver Metallic SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.59 0.60

Sky Blue SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.29 0.28

Slate Gray SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.36 0.33

Stone White SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.57 0.56

Terra Cotta SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.34 0.33

Tropical Patina SR UC-1, UC-2, UC-3, UC-4, UC-6, UC-7, UC-14, UC-600, UC-601, 5VC, HR Ultra Omega Panel, VR Classic Omega, UR Pro Omega

0.28 0.28

Page 36: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

36 | P a g e

J u n e 2 0 1 4

1.07 CRRC Rated Panels

TABLE 1.07 CRRC RATED PANELS

Color Brand Initial Solar Reflectance

3-year Solar Reflectance

Initial Emittance

3-year Emittance CRRC Product ID

Stone White SR Any panel 0.55 0.55 0.83 0.82 0806-0010 Fluropon Cityscape Any panel 0.35 0.34 0.84 0.83 0806-0004 Fluropon Classic II Silver Metallic

Any panel 0.56 0.55 0.76 0.76 0806-0005

Fluropon Bone White Any panel 0.70 0.69 0.84 0.84 0806-0006 Fluropon Sandstone Any panel 0.51 0.49 0.84 0.83 0806-0007 Classic Copper SR Any panel 0.35 0.35 0.75 0.75 0806-0022 Charcoal Gray SR Any panel 0.25 0.25 0.83 0.82 0806-0021 Mansard Brown SR Any panel 0.25 0.25 0.83 0.83 0806-0019 Hemlock Green SR Any panel 0.25 0.25 0.83 0.83 8060-0015 Patina Green SR Any panel 0.32 0.32 0.83 0.82 0806-0014 Almond SR Any panel 0.55 0.55 0.83 0.82 0806-0013 Medium Bronze SR Any panel 0.25 0.25 0.83 0.83 0806-0011 Slate Gray SR Any panel 0.35 0.35 0.83 0.81 8060-0009 Terra Cotta SR Any panel 0.35 0.35 0.83 0.82 0806-0012 Sky Blue SR Any panel 0.25 0.25 0.83 0.83 0806-0023 Colonial Red SR Any panel 0.25 0.25 0.83 0.82 0806-0016

1.08 Air Infiltration & Water Penetration TABLE 1.08A

ASTM E283 AND E1680 AIR INFILTRATION TESTS

Panel System: ASTM E283 ASTM E1680

Static Pressure Differential (PSF)

Air Infiltration Rate (CFM/SF)

Preload Pressure (PSF)

Static Pressure Differential (PSF)

Air Infiltration Rate (CFM/SF)

UC-1

24ga Steel & 0.038” Aluminum 17.0” Wide w/ Batten

1.56 0.03

6.24 0.06

UC-3

24ga Steel & .040” Aluminum 17.75” Wide w/o sealant

1.56 0.03

6.24 0.05

24ga Steel 20” Wide w/o Sealant 12.0 0.044 15±

-1.57 0.011

1.57 0.008

-6.24 0.0138

6.24 0.0333

24ga Steel 18” Wide w/ Sealant

15+/30- ±1.57 0.0015

±6.24 0.0022

UC-4

24ga Steel & .040” Aluminum 17.75” Wide

1.56 (w/o sealant) 0.22

6.24 (w/o sealant) 0.52

1.56 (w/ sealant) 0.04

6.24 (w/ sealant) 0.17

24ga Steel 18” Wide w/ Sealant 15±

-1.57 0.010

1.57 0.028

-6.24 0.010

6.24 0.099

Page 37: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

37 | P a g e

J u n e 2 0 1 4

TABLE 1.08A (CONT.) ASTM E283 and E1680 Air Infiltration Tests

Panel System: ASTM E283 ASTM E1680

Static Pressure Differential (PSF)

Air Infiltration Rate (CFM/SF)

Preload Pressure (PSF)

Static Pressure Differential (PSF)

Air Infiltration Rate (CFM/SF)

UC-6

24ga Steel 18” Wide w/ Sealant

15+/30-

±1.57 0.0031

±6.24 0.0091

UC-14

24ga Steel 18” Wide w/ Sealant

15+/30-

±1.57 0.0017

±6.24

0.0039

UC-500

24 gauge steel and 0.038 Aluminum, 12” wide

1.56 (w/o sealant) 0.07

6.24 (w/o sealant) 0.17

1.56 (w/ sealant) 0.03

6.24 (w/ sealant) 0.11

TABLE 1.08B

ASTM E331 AND E1646 WATER PENETRATION TESTS

Panel System: ASTM E331 ASTM E1646

Static Pressure Differential (PSF) Water Infiltration Preload

Pressure (PSF)

Static Pressure Differential

(PSF) Water Infiltration

UC-1

24ga Steel & 0.038” Aluminum 17.0” Wide w/ Batten 10.5 None

24ga Steel 18.0” Wide w/ Batten 6.24 None 15± 2.86 None

UC-2 24ga Steel 16” Wide w/ Batten 6.24 None 15± 2.86 None

UC-3

24ga Steel & .040” Aluminum 17.75” Wide w/o Sealant 10.5 None

24ga Steel 20” Wide w/o Sealant 12.0 None 15± 2.86 None

24ga Steel 18” Wide w/ Sealant

15+/30- 15.0 None

UC-4

24ga Steel & 0.038” Aluminum 17.75” Wide w/o Sealant 10.5 None

24ga Steel 18” Wide w/ Sealant 12.0 None 15± 2.86 None

UC-6

24ga Steel 16” Wide w/ Sealant 15+/30- 12.0 None

Page 38: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

38 | P a g e

J u n e 2 0 1 4

TABLE 1.08B (CONT.) ASTM E331 and E1646 Water Penetration Tests

Panel System: ASTM E331 ASTM E1646

Static Pressure Differential (PSF) Water Infiltration Preload

Pressure (PSF)Static Pressure

Differential (PSF) Water Infiltration

UC-14

24ga Steel 18” Wide w/ Sealant 15+/30- 12.0 None

UC 500

24 gauge steel and 0.038 Aluminum, 12” wide

10.5 sealed No Entry

10.5 unsealed No Entry

1.09 Structural Performance

Table 1.09a ASTM E330 Structural Performance Tests

Product Name Panel width Material type Material thickness Purlin Spacing

Max. Test Uplift

Pressure (psf)

Design Uplift pressure (psf)

UC-1 17.0” Steel 24 ga 2.0’ - 60

Aluminum 0.038 2.0’ - 75

UC-2 21.0” Aluminum 0.032

1.0’-2.0’ - 22.97 2.25’ - 20.65 2.5’ - 18.33

2.75’ - 16.01 3.0’ - 13.69

UC-2 17.0” Aluminum 0.032

1.0’ - 31.8 1.25’ - 29.4 1.5’ - 27.1

1.75’ - 54.8 2.0’ - 22.5

2.25’ - 20.9 2.5’ - 19.4

2.75’ - 17.9 3.0’

- 16.4

UC-2 13.0” Aluminum 0.032

1.0’ - 35.5 1.25’ - 33.2 1.5’ - 30.9

1.75’ - 28.6 2.0’

- 26.3 2.25’ - 23.6 2.5’ - 21.0

2.75’ - 18.3 3.0’ - 15.7

UC-2 17.0” Aluminum .040

1.0’ - 47.13 1.25’ - 45.84 1.5’ - 44.56

1.75’ - 43.28 2.0’ - 42.00

2.25’ - 37.68 2.5’ - 33.37

2.75’ - 29.06 3.0’ - 24.74

Page 39: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

39 | P a g e

J u n e 2 0 1 4

Table 1.09a (Cont.) ASTM E330 Structural Performance Tests

Product Name Panel width Material type Material thickness Purlin Spacing

Max. Test Uplift

Pressure (psf)

Design Uplift pressure (psf)

UC-2 13.0” Aluminum .040

1.0’ - 45.4 1.25’ - 42.8 1.5’ - 40.2

1.75’ - 37.6 2.0’ - 35.1

2.25’ - 32.0 2.5’ - 29.0

2.75’ - 26.0 3.0’ - 23.0

UC-2 13.0” Steel 24 ga.

1.0’ - 33.9 1.25’ - 31.9 1.5’ - 30.0

1.75’ - 28.0 2.0’ - 26.1

2.25’ - 24.2 2.5’ - 22.3

2.75’ - 20.4 3.0’ - 18.5

UC-2 17.0” Steel 0.024

1.0’ - 22.12 1.25’ - 20.76 1.5’ - 19.40

1.75’ - 18.04 2.0’ - 16.68

2.25’ - 16.46 2.5’ - 16.25

2.75’ - 16.04 3.0’ - 15.83

UC-2 17.0” Steel 0.030

1.0’ - 37.43

1.25’ - 35.57 1.5’ - 33.71

1.75’ - 31.85 2.0’ - 30.00

2.25’ - 29.59 2.5’ - 29.19

2.75’ - 28.79 3.0’ - 28.39

UC-2 21.0” Steel 0.024

1.0’ - 18.07 1.25’ - 16.78 1.5’ - 15.50

1.75’ - 14.22 2.0’ - 12.94

2.25’ - 12.35 2.5’ - 11.77

2.75’ - 11.19 3.0’ - 10.61

UC-2 21.0” Steel 0.030

1.0’ - 28.87 1.25’ - 27.03 1.5’ - 25.19

1.75’ - 23.35 2.0’ - 21.51

2.25’ - 21.45 2.5’ - 21.39

2.75’ - 21.33 3.0’ - 21.28

UC-3 17.75” Steel 24 ga. 2.0’ -45 UC-3 17.75” Aluminum 0.038 2.0’ -75 UC-4 17.75” Aluminum 0.038 2.0’ -75

Page 40: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

40 | P a g e

J u n e 2 0 1 4

Table 1.09a (Cont.) ASTM E330 Structural Performance Tests

Product Name Panel width Material type Material thickness Purlin Spacing

Max. Test Uplift

Pressure (psf)

Design Uplift pressure (psf)

UC-4 17.75” Steel 24 ga. 2.0’ -105

UC-7 12.0” Aluminum 0.032

1.0’ - 104.3 - 41.7 1.25’ - 39.1 1.5’ - 36.5

1.75’ - 33.9 2.0’ - 78.3 - 31.3

2.25’ - 28.8 2.5’ - 26.4

2.75’ - 23.9 3.0’ - 53.95 - 21.5

UC-7 12.0” Aluminum .040

1.0’ - 111.1 - 44.4 1.25’ - 41.1 1.5’ - 37.8

1.75’ - 34.5 2.0’ - 78.3 - 31.3

2.25’ - 28.8 2.5’ - 26.4

2.75’ - 23.9 3.0’ - 53.9 - 21.5

UC-7 16.0” Aluminum 0.032

1.0’ - 72.7 - 29.0 1.25’ -27.3 1.5’ - 25.6

1.75’ - 23.9 2.0’ - 55.5 - 22.2

2.25’ - 20.6 2.5’ - 19.1

2.75’ - 17.6 3.0’ - 40.0 - 16.0

UC-7 16.0” Aluminum .040

1.0’ - 89.0 - 35.6 1.25’ - 33.2 1.5’ - 30.9

1.75’ - 28.6 2.0’ - 65.8 - 26.3

2.25’ - 24.3 2.5’ - 22.3

2.75’ - 20.3 3.0’ - 45.75 - 18.3

UC-7 12.0” Steel 24 ga.

1.0’ - 103.7 - 41.4 1.25’ - 38.3 1.5’ - 35.2

1.75’ - 32.1 2.0’ - 72.9 - 29.1

2.25’ - 28.0 2.5’ - 27.0

2.75’ - 26.0 3.0’ - 62.6 - 25.0

UC-7 12.0” Steel 22 ga.

1.0’ - 157.9 - 63.1 1.25’ - 59.1 1.5’ - 55.2

1.75’ - 51.3 2.0’ - 118.7 - 47.4

2.25’ - 44.1 2.5’ - 40.8

2.75’ - 37.5 3.0’ - 85.6 - 34.2

Page 41: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

41 | P a g e

J u n e 2 0 1 4

Table 1.09a (Cont.) ASTM E330 Structural Performance Tests

Product Name Panel width Material type Material thickness Purlin Spacing

Max. Test Uplift

Pressure (psf)

Design Uplift pressure (psf)

UC-7 16.0” Steel 24 ga.

1.0’ - 66.0 - 26.4 1.25’ - 25.1 1.5’ - 23.9

1.75’ - 22.7 2.0’ - 53.8 - 21.5

2.25’ - 20.8 2.5’ - 20.1

2.75’ - 19.4 3.0’ - 47.17 - 18.8

UC-7 16.0” Steel 22 ga.

1.0’ - 101.0 - 40.4 1.25’ - 38.3 1.5’ - 36.3

1.75’ - 34.3 2.0’ - 80.75 - 32.3

2.25’ - 30.8 2.5’ - 29.3

2.75’ - 27.8 3.0’ - 65.8 - 26.3

UC-500 12.0” Alum 0.038” 2.0’ -105

UC-500 12.0” Steel 22 ga. 4.0’ -38 5.0’ -20

UC-500 12.0” Steel 24 ga. 2.0’ -60 4.0’ -27

UC-500 12.0” Steel 26 ga. 4.0’ -20

TABLE 1.09B ASTM E1592 Structural Performance Tests

Product Name Panel Width

Material Type Clip Clip/Purlin Spacing

Max. Test Uplift

Pressure (psf)

Design Uplift Pressure (psf)

UC-3 14.0” 16 oz. Copper

UC-3 Stainless Steel Expansion Clip

1.0’ - 100.8 - 61.0 2.5’ - 51.8 3.0’ -42.7 3.5’ - 33.6 4.0’ - 40.4 - 24.4

UC-3 20” 24 ga Steel UC-3 Stainless Steel Expansion

Clip

1.0’ -190.0 -95.0 1.25’ -89.58 1.5’ -84.17

1.75’ -78.75 2.0’ -73.33

2.25’ -67.92 2.5’ -62.50

2.75’ -57.08 3.0’ -51.67

3.25’ -46.25 3.5’ -40.83

3.75’ -35.42 4.0’ -60.0 -30.0

UC-3 20” 0.032”

Aluminum UC-3 Stainless Steel Expansion

Clip 1.0’ - 150.0

4.0’ - 45.0

UC-4 18” 24 ga Steel N/A 1.0’ - 58.5

4.0’ - 48.1

UC-4 18” 0.032”

Aluminum N/A 1.0’ -55.0

4.0’ -15.0

Page 42: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

42 | P a g e

J u n e 2 0 1 4

TABLE 1.09B (CONT.) ASTM E1592 Structural Performance Tests

Product Name Panel Width

Material Type Clip Clip/Purlin Spacing

Max. Test Uplift

Pressure (psf)

Design Uplift Pressure (psf)

UC-6 18” 24 ga Steel UC-6 Low-Float Clip, Galvanized Steel

1.0’ -220.0 -110.0 1.25’ -104.69 1.5’ -99.38

1.75’ -94.06 2.0’ -88.75

2.25’ -83.44 2.5’ -78.13

2.75’ -72.81 3.0’ -67.5

3.25’ -62.19 3.5’ -56.88

3.75’ -51.56 4.0’ -46.25

4.25’ -40.94 4.5’ -35.63

4.75’ -30.31 5.0’ -50.0 -25.0

UC-6 16” 0.032” Aluminum

UC-6 Low-Float Clip 1.0’ -114.9 5.0’ -49.9

UC-6 18” 0.032” Aluminum

UC-6 Low Float Clip, Stainless Steel

1.0’ -180.0 -90.0 1.25’ -85.94 1.5’ -81.88

1.75’ -77.81 2.0’ -73.75

2.25’ -69.69 2.5’ -65.63

2.75’ -61.56 3.0’ -57.50

3.25’ -53.44 3.5’ -49.38

3.75’ -45.31 4.0’ -41.25

4.25’ -37.19 4.5’ -33.13

4.75’ -29.06 5.0’ -50.0 -25.0

UC-14 16” 24 ga Steel UC-14 Clip, Galvanized Steel

1.0’ -180.0 -50.00 1.25’ -47.92 1.5’ -45.83

1.75’ -43.75 2.0’ -41.67

2.25’ -39.58 2.5’ -37.50

2.75’ -35.42 3.0’ -33.33

3.25’ -31.25 3.5’ -29.17

3.75’ -27.08 4.0’ -50.0 -25.00

UC-14 18” 24 ga steel UC-14 Clip, Galvanized Steel 1.0’ -95.0

4.0’ -40.0

UC-14 18” .032”

Aluminum UC-14 Clip, Stainless Steel

1.0’ -55.0

4.0’ -30.0

Page 43: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

43 | P a g e

J u n e 2 0 1 4

Verify all FM approved assemblies on www.RoofNav.com Factory Mutual – Firestone Building Products Metal Panel Assemblies

Firestone UNA-CLAD UC-3 Metal Panel Uplift Ratings

Existing Roof Uplift Deck Vapor

Retarder Separator Sheet, Substrate and

Attachment Bearing

Plate Panel Clip Clip Fastener RoofNav

Assembly Number

1-105 Steel, 22 gauge Min., 33 ksi.

Opt ional: Polyethylene (6m il)

- Firestone I SO 95+ GL, .5” -1” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prime ¼ ” Min.

Yes UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 12 w/ nylon washer – 2 per clip.

259348-0-0

1-105

Steel, 22 gauge Min., 33 ksi.

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, .5” -1” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prime ¼ ” Min.

No UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 10 (Stainless or E-Coated) – 2 per clip.

259349-0-0

1-105 Steel, 22 gauge Min., 33 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - Firestone I SO 95+ GL, .5” -1” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prime ¼ ” Min.

Yes UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 12 w/ nylon washer – 2 per clip.

301645-0-0

1-105 Steel, 22 gauge Min., 33 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, .5” -1” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prime ¼ ” Min.

No UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 10 (Stainless or E-Coated) – 2 per clip.

301646-0-0

1-120 Steel, 22 gauge Min., 33 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, .5” -1” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prime ¼ ” Min.

No UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 10 (Stainless or E-Coated) – 2 per clip.

301642-0-0

1-120 Steel, 22 gauge Min., 33 ksi.

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, .5” -1” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prime ¼ ” Min.

No UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 10 (Stainless or E-Coated) – 2 per clip.

259347-0-0

Firestone UNA-CLAD UC-3 Steel Panel Uplift Ratings

New Roof Uplift Deck Vapor

Retarder Separator Sheet, Substrate and

Attachment Bearing

Plate Panel Clip Clip Fastener RoofNav

Assembly Number

1-105 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

- Firestone I SO 95+ GL, 1.5” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

Yes UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 12 w/ nylon washer – 2 per clip.

259335-0-0

1-105 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, 1.5” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ”

No UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 10 (Stainless or E-Coated) – 2 per clip.

259336-0-0

Page 44: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

44 | P a g e

J u n e 2 0 1 4

Firestone UNA-CLAD UC-3 Steel Panel Uplift Ratings (Cont.) New Roof

Uplift Deck Vapor Retarder

Separator Sheet, Substrate and Attachment

Bearing Plate

Panel Clip Clip Fastener RoofNav Assembly Number

1-105 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

- Firestone HailGard, 1.5” -4” 4’x8’ boards.

No UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 10 (Stainless or E-Coated) – 2 per clip.

259337-0-0

1-105 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - Firestone I SO 95+ GL, 1.5” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ”

Yes UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 12 w/ nylon washer – 2 per clip.

301628-0-0

1-105 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, 1.5” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ”

No UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 10 (Stainless or E-Coated) – 2 per clip.

301631-0-0

1-105 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board.

No UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 10 (Stainless or E-Coated) – 2 per clip.

301634-0-0

1-120 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, 1.5” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ”

No UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 10 (Stainless or E-Coated) – 2 per clip.

259059-0-0

1-120 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board.

No UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 10 (Stainless or E-Coated) – 2 per clip.

259334-0-0

1-120 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, 1.5” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ”

No UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 10 (Stainless or E-Coated) – 2 per clip.

301583-0-0

1-120 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, 1.5” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ”

No UC-3 Stainless Expansion Clip, 12” oc w/ 20” max panel.

UNA-CLAD # 10 (Stainless or E-Coated) – 2 per clip.

301625-0-0

1-120 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board - Firestone I SO 95+ GL, I SOGARD HD Comp., or Resista, 1.5” -1-12” , 4’x8’ boards

No UC-3 Stainless Expansion Clip, 12” oc w/ 16” max panel.

UNA-CLAD # 10 (Stainless) – 2 per clip.

341935-0-0

Page 45: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

45 | P a g e

J u n e 2 0 1 4

Firestone UNA-CLAD UC-4 Steel Panel Uplift Ratings Existing Roof

Uplift Deck Vapor Retarder

Separator Sheet, Substrate and Attachment Bearing Plate

Fastener RoofNav Assembly Number

1-105 Steel, 22 gauge Min., 33 ksi.

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, .5” - .5” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 9.75” row spacing, 1” m inim um and 1.5” m axim um length.

259351-0-0

1-105 Steel, 22 gauge Min., 33 ksi

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, .5” - .5” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 9.75” row spacing, 1” m inim um and 1.5” m axim um length.

301654-0-0

1-165 Steel, 22 gauge Min., 33 ksi

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - Firestone I SO 95+ GL, .5” - .1” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

Yes UNA-CLAD # 12 (Stainless or Steel) w/ nylon washer– 12” oc, 9.75” row spacing, 1” m inimum and 1.5” m axim um length. 2 per plate. * See Comm ent under Securement in RoofNav.

301649-0-0

1-165 Steel, 22 gauge Min., 33 ksi

Opt ional: Polyethylene (6m il)

- Firestone I SO 95+ GL, .5” - .1” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

Yes UNA-CLAD # 12 (Stainless or Steel) w/ nylon washer– 12” oc, 9.75” row spacing, 1” m inimum and 1.5” m axim um length. 2 per plate. * See Comm ent under Securement in RoofNav.

259350-0-0

Firestone UNA-CLAD UC-4 Steel Panel Uplift Ratings

New Roof Uplift Deck Vapor

Retarder Separator Sheet, Substrate and Attachment Bearing

Plate Fastener RoofNav

Assembly Number

1-105 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, 1” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No

UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 9.75” row spacing, 1” m inim um and 1.5” m axim um length.

259338-0-0

1-105 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, 1” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No

UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 9.75” row spacing, 1” m inim um and 1.5” m axim um length.

301637-0-0

1-120 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

- Firestone HailGard, 1.5” -4” thickness. 16 All-Purpose Fasteners per 4’x8’ board.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 9.75” row spacing, 1” m inim um and 1.5” m axim um length.

259340-0-0

1-120 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - Firestone HailGard, 1.5” -4” thickness. 16 All-Purpose Fasteners per 4’x8’ board.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 9.75” row spacing, 1” m inim um and 1.5” m axim um length.

301640-0-0

1-165 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

- Firestone I SO 95+ GL, 1” -4” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

Yes UNA-CLAD # 12 (Stainless or Steel) w/ nylon washer– 12” oc, 9.75” row spacing, 2 per plate. * See Comm ent under Securement in RoofNav.

259060-0-0

Page 46: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

46 | P a g e

J u n e 2 0 1 4

Firestone UNA-CLAD UC-4 Steel Panel Uplift Ratings (Cont.) New Roof

Uplift Deck Vapor Retarder

Separator Sheet, Substrate and Attachment Bearing Plate

Fastener RoofNav Assembly Number

1-165 Steel, 22-18 gauge, 33 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - Firestone I SO 95+ GL, 1” -4” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

Yes UNA-CLAD # 12 (Stainless or Steel) w/ nylon washer– 12” oc, 9.75” row spacing, 2 per plate. * See Comm ent under Securement in RoofNav.

301595-0-0

Firestone UNA-CLAD UC-6 Steel Panel Uplift Ratings

Existing Roof Uplift Deck Vapor

Retarder Separator Sheet, Substrate and Attachment Bearing

Plate Fastener RoofNav

Assembly Number

1-90 Steel, 22 gauge Min., 36 ksi.

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, .5” - .5” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip. UC-6 Super Clips (Galvanized or Stainless Steel) .

259407-0-0

1-90 Steel, 22 gauge Min., 36 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, .5” - .5” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip. UC-6 Super Clips (Galvanized or Stainless Steel) .

301686-0-0

1-105 Steel, 22 gauge Min., 36 ksi.

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, , 24 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, .5” - .5” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip. UC-6 Low Float Clips (Galvanized or Stainless Steel) .

259394-0-0

1-105 Steel, 22 gauge Min., 36 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, .5” - .5” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip. UC-6 Low Float Clips (Galvanized or Stainless Steel) .

301677-0-0

1-135 Steel, 22 gauge Min., 36 ksi.

Opt ional: Polyethylene (6m il)

- Firestone I SO 95+ GL, .5” - .5” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

Yes UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip w/ opt ional nylon washer. UC-6 Super Clips (Galvanized or Stainless Steel) .

259406-0-0

1-135 Steel, 22 gauge Min., 36 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - Firestone I SO 95+ GL, .5” - .1” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

Yes UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip w/ opt ional nylon washer. UC-6 Super Clips (Galvanized or Stainless Steel) .

301678-0-0

Firestone UNA-CLAD UC-6 Steel Panel Uplift Ratings

No Deck Uplift Deck Separator Sheet, Substrate and Attachment Bearing

Plate Fastener RoofNav

Assembly Number

1-150 None -Bay insulat ion (varying types) , 3” -6” thickness, or glass fiber bat ts & blankets (unfaced) , 2” -6” thickness.

No UNA-CLAD # 12 Purlin Drilling – 36” oc, 18” row spacing, 2 per clip. UC-6 Low Float Clips (Galvanized or Stainless Steel) .

259061-0-0

Page 47: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

47 | P a g e

J u n e 2 0 1 4

Firestone UNA-CLAD UC-6 Steel Panel Uplift Ratings New Roof

Uplift Deck Vapor Retarder

Separator Sheet, Substrate and Attachment Bearing Plate

Fastener RoofNav Assembly Number

1-90 Steel, 22-16 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 All-Purpose Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, 1” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip. UC-6 Super Clips (Galvanized or Stainless Steel) .

259360-0-0

1-90 Steel, 22-16 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, 1” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip. UC-6 Super Clips (Galvanized or Stainless Steel) .

301667-0-0

1-105 Steel, 22-18 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, 1” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip. UC-6 Low Float Clips (Galvanized or Stainless Steel) .

259358-0-0

1-105 Steel, 22-18 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

- Firestone HailGard, 1.5” -4” thickness. 24 HD HailGard Fasteners per 4’x8’ board.

N0 UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip. UC-6 Low Float Clips (Galvanized or Stainless Steel) .

259361-0-0

1-105 Steel, 22-18 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 16 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, I SOGARD HD Com posite, or Resista, 1.5” -12” , 4’x8’ boards.

N0 UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip. UC-6 Low Float Clips (Galvanized or Stainless Steel) .

341936-0-0

1-105 Steel, 22-18 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, 1” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip. UC-6 Low Float Clips (Galvanized or Stainless Steel) .

301664-0-0

1-105 Steel, 22-18 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - Firestone HailGard, 1.5” -4” thickness. 24 HD HailGard Fasteners per 4’x8’ board.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip. UC-6 Low Float Clips (Galvanized or Stainless Steel) .

301669-0-0

1-120 Steel, 22-18 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

- Firestone HailGard, 1.5” -4” thickness. 16 All-Purpose Fasteners per 4’x8’ board.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip. UC-6 Super Clips (Galvanized or Stainless Steel) .

259362-0-0

1-120 Steel, 22-18 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - Firestone HailGard, 1.5” -4” thickness. 16 All-Purpose Fasteners per 4’x8’ board.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip. UC-6 Super Clips (Galvanized or Stainless Steel) .

301671-0-0

1-135 Steel, 22-18 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

- Firestone I SO 95+ GL, 1” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

Yes UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip w/ opt ional nylon washers. UC-6 Super Clips (Galvanized or Stainless Steel) .

259359-0-0

1-135 Steel, 22-18 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - Firestone I SO 95+ GL, 1” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

Yes UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 2 per clip w/ opt ional nylon washers. UC-6 Super Clips (Galvanized or Stainless Steel) .

301666-0-0

Page 48: UNA-CLAD™ Metal Roof Systems - BuildSite...3) Min. one layer of Elk “Versashield” Ply Sheet (Optional): One or more layers of Polystick MTS, Nova Seal Generation II Premium Roofing

48 | P a g e

J u n e 2 0 1 4

Firestone UNA-CLAD UC-14 Steel Panel Uplift Ratings Existing Roof

Uplift Deck Vapor Retarder

Separator Sheet, Substrate and Attachment Bearing Plate

Fastener RoofNav Assembly Number

1-60 Steel, 22 gauge Min., 36 ksi.

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, .5” - .5” , 4’x8’ boards, I SOGARD HD, .5” - .5” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 1” m in length and 1.5” max length.

259408-0-0

1-60 Steel, 22 gauge Min., 36 ksi.

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, .5” - .5” , 4’x8’ boards, I SOGARD HD, .5” - .5” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 1” m in length and 1.5” max length.

301688-0-0

Firestone UNA-CLAD UC-14 Steel Panel Uplift Ratings

New Roof Uplift Deck Vapor

Retarder Separator Sheet, Substrate and Attachment Bearing

Plate Fastener RoofNav

Assembly Number

1-60 Steel, 22-16 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, 1” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 1” m in length and 1.5” max length.

301656-0-0

1-60 Steel, 22-16 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

Opt ional: Separator Sheet – Firestone CLAD-GARD SA. - Firestone HailGard, 1.5” -4” thickness. 24 HD HailGard Fasteners per 4’x8’ board.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 1” m in length and 1.5” max length.

301660-0-0

1-60 Steel, 22-16 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board. Opt ional: Firestone I SO 95+ GL, 1” -12” , 4’x8’ boards, I SOGARD HD, .5” -1” , DensDeck or Prim e ¼ ” Min.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 1” m in length and 1.5” max length.

259354-0-0

1-60 Steel, 22-16 gauge, 33 ksi

Opt ional: Polyethylene (6m il)

- APA Rated OSB, 7/ 16” -1/ 2” thickness, 24 HD HailGard Fasteners per 4’x8’ board.

No UNA-CLAD # 10 (Stainless or E-Coated) – 12” oc, 18” row spacing, 1” m in length and 1.5” max length.

259354-0-0

1.11 Concentrated Load Testing

Testing is per FM 4471, Section 5.4 Foot Traffic Resistance, which uses a 200# load concentrated on a 3” x 3” square area at mid span with joists on 5 foot centers.

Table 1.11 Concentrated Load Testing

Panel Panel description Maximum Deflection

Permanent Deflection Damage

UC-3 Nominal 20” wide, 24 ga. Steel with 1.5” rib; 180˚ seam 0.1875” None No failure

UC-4 Nominal 17-3/4” wide, 24 ga. Steel with 1.5” Snap rib 0.125” None No failure

UC-14 Nominal 18” wide, 24 ga. Steel with 1.75” rib; Snap Lock 0.0625” None No failure

UC-6 Nominal 18” wide, 24 ga. Steel with 1.5” rib; 180˚ seam 0.0625” None No failure