Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder...

84
Ultrasound of the Shoulder Patrick Battaglia, DC, DACBR Logan University, Department of Radiology © 2018 Logan University, Department of Radiology

Transcript of Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder...

Page 1: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Ultrasound of the ShoulderPatrick Battaglia, DC, DACBR

Logan University, Department of Radiology

© 2018 Logan University, Department of Radiology

Page 2: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Outline

• Review ultrasound appearance of NMSK tissues

• Present indications for ultrasound of the shoulder.

• Present an introductory shoulder protocol.

© 2018 Logan University, Department of Radiology

Page 3: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Ultrasound appearance of neuromusculoskeletal tissues

Page 4: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

ANATOMY

• Muscle

• Tendon

• Ligament

• Nerve

• Bone

© 2018 Logan University, Department of Radiology

Page 5: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

SKELETAL MUSCLE

SHORT-AXIS

LONG-AXIS

Radiographics. 2018 Jan-Feb;38(1):124-148

© 2018 Logan University, Department of Radiology

Page 6: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

SKELETAL MUSCLE – FULL THICKNESS TEAR

SKELETAL MUSCLE – NORMAL MUSCLE

© 2018 Logan University, Department of Radiology

Page 7: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

TENDON/LIGAMENT

SHORT-AXIS

LONG-AXIS

Acta Biomater. 2017 Nov;63:18-36.

© 2018 Logan University, Department of Radiology

Page 8: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

TENDON/LIGAMENT – FULL THICKNESS TEAR

© 2018 Logan University, Department of Radiology

Page 9: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

TENDON/LIGAMENT – TENDINOSIS

© 2018 Logan University, Department of Radiology

Page 10: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

PERIPHERAL NERVE

SHORT-AXIS

LONG-AXIS

June 2016 Expert Review of Medical Devices 13(8)

© 2018 Logan University, Department of Radiology

Page 11: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

PERIPHERAL NERVE – ENTRAPMENT NEUROPATHY

© 2018 Logan University, Department of Radiology

Page 12: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

BONE

SHORT-AXIS

LONG-AXIS

By SEER - U.S. National Cancer Institute's Surveillance, Epidemiology and End Results (SEER) Program (http://training.seer.cancer.gov/index.html)Exact adress, Public Domain, https://commons.wikimedia.org/w/index.php?curid=378948

© 2018 Logan University, Department of Radiology

Page 13: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

BONE – ACUTE FRACTURE

© 2018 Logan University, Department of Radiology

Page 14: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

BONE – HEALING FRACTURE WITH CALLUS

© 2018 Logan University, Department of Radiology

Page 15: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Ultrasound of the shoulder

Page 16: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Indications for shoulder ultrasound

• Bursitis

• Rotator cuff and long head of the biceps tendinopathy and tear

• Postoperative cuff failure

• Pectoral muscle tears

• Acromioclavicular joint osteoarthritis, trauma, and instability

• Suprascapular nerve entrapment

Sconfienza et al. Eur Radiol. 2018 Jun 6. [Epub ahead of print] © 2018 Logan University, Department of Radiology

Page 17: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Limitations of shoulder ultrasound

• Bone evaluation (including cartilage and marrow)

• Glenoid labrum evaluation*

• Adhesive capsulitis*

• Thoracic outlet syndrome*

* Limited evidence – emerging applications

Sconfienza et al. Eur Radiol. 2018 Jun 6. [Epub ahead of print] © 2018 Logan University, Department of Radiology

Page 18: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Introductory shoulder protocol

Page 19: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

*All anatomy plates, unless otherwise noted, are attributed to:

e-Anatomy, Micheau A, Hoa D, imaios.com

© 2018 Logan University, Department of Radiology

Page 20: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Introductory shoulder protocol

• Biceps tendon short and long axis

• Subscapularis tendon long and short axis

• Subacromial space and bursa

• Rotator interval

• Posterior rotator cuff (supra- and infraspinatus, teres minor tendons) – long and short axis

• Posterior glenohumeral joint

• Supraspinatus muscle

• Infraspinatus muscle

© 2018 Logan University, Department of Radiology

Page 21: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

CROSS-SECTIONAL ANATOMY

http://www.freitasrad.net/pages/atlas/Shoulder/Shoulder.html

© 2018 Logan University, Department of Radiology

Page 22: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

BICEPS TENDON SHORT AXIS AT INTERTUBERCULAR GROOVE

Page 23: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

BICEPS TENDON SHORT AXIS AT INTERTUBERCULAR GROOVE

Page 24: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

BICEPS TENDON LONG AXIS AT INTERTUBERCULAR GROOVE

Page 25: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Long head biceps tendon pathology

• LHBT tendinosis/ tenosynovitis

• LHBT rupture

• LHBT subluxation/dislocation

• Fluid in the tendon sheath

© 2018 Logan University, Department of Radiology

Page 26: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Long head biceps tendinosis

http://ultrasoundcases.info

© 2018 Logan University, Department of Radiology

Normal

Page 27: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Long head biceps tendon rupture

© 2018 Logan University, Department of Radiology

Page 28: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Long head biceps tendon pathology• Fluid in the tendon sheath of the LHBT

• Fluid in the LHBT tendon sheath on ultrasound is highly predictive of rotator cuff tears or LHBT pathology• Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff

tear: analysis of a consecutive cohort. J Shoulder Elbow Surg. 2016 Oct;25(10):1661-7.

© 2018 Logan University, Department of Radiology

Page 29: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

SUBSCAPULARIS TENDON LONG AXIS

Page 30: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

SUBSCAPULARIS TENDON LONG AXIS

Page 31: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

SUBSCAPULARIS TENDON SHORT AXIS

Page 32: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

SUBSCAPULARIS TENDON SHORT AXIS

Page 33: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Subscapularis Tendon Pathology

• Tendinosis

• Tear• Allows LHBT subluxation/dislocation)

© 2018 Logan University, Department of Radiology

Page 34: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Subscapularis tendinosis

© 2018 Logan University, Department of Radiology

Normalhttp://ultrasoundcases.info

Page 35: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Subscapularis tear

© 2018 Logan University, Department of Radiology

Page 36: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Subscapularis tear

© 2018 Logan University, Department of Radiology

Page 37: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

SUBACROMIAL SPACE AND BURSA

Page 38: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

SUBACROMIAL SPACE AND BURSA

HUMERUS

ACROMION

ROTATOR CUFF

Bursal complex:• Peribursal fat (yellow)• Fluid (purple)

Page 39: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Subacromial impingement

• At ultrasound, failure of humeral depression may be seen, but is subjective

• Ultrasound signs of impingement:• Rotator cuff thickening

• Bursal sided tearing

• Subacromial/subdeltoid bursitis or thickening (normal bursa ≤ 2 mm)

• Accumulation of bursal fluid with abduction or flexion more reliable ultrasound signs

© 2018 Logan University, Department of Radiology

Page 40: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

SUBACROMIAL IMPINGEMENT

© 2018 Logan University, Department of Radiology

Page 41: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

SUBACROMIAL IMPINGEMENT

Page 42: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

SUBACROMIAL IMPINGEMENT

Page 43: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

• Correlate (passive external rotation)

• Look for a normal rotator cuff

• See: Ryu et al. J Ultrasound Med. 1993 Aug;12(8):445-9.

DIFFERENTIAL DIAGNOSIS – ADHESIVE CAPSULITIS

Page 44: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

ROTATOR INTERVAL

Ultrasound Int Open. 2017 Jun;3(3):E107-E116.

Page 45: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

ROTATOR INTERVAL

HUMERUS

SSTSCT

BT

Page 46: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Rotator interval - pathology

• Long head of the biceps tendon pathology• Tear

• Dislocation

• Supraspinatus and subscapularis pathology

• Joint capsule and related pathology• Effusion

• Capsulitis

© 2018 Logan University, Department of RadiologyUltrasound Int Open. 2017 Jun;3(3):E107-E116.

Page 47: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

ACUTE BICEPS LONG HEAD TENDON TEAR

Page 48: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

ADHESIVE CAPSULITIS

http://ultrasoundcases.info/Slide-View.aspx?cat=331&case=4110

NORMAL

Page 49: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF

Page 50: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – LONG AXIS IMAGE(S) – CRASS POSITION

Page 51: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – LONG AXIS IMAGE(S) – MODIFIED CRASS POSITION

Page 52: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – LONG AXIS IMAGE(S) – CRASS V. MODIFIED CRASS POSITIONS

Page 53: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

CRASS V. MODIFIED CRASS POSITIONS

• Ferri M 2005:• Modified Crass position may over-estimate size of rotator cuff tear in long-axis

• No difference in short-axis

• Shah NP 2012:• No difference between Crass, modified Crass, and neutral positions for

diagnosing posterior rotator cuff pathology

Page 54: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – LONG AXIS IMAGE(S)

DELTOID MUSCLE

HUMERUS

© 2018 Logan University, Department of Radiology

Page 55: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – LONG AXIS IMAGE(S)

DELTOID MUSCLE

HUMERUS

© 2018 Logan University, Department of Radiology

Page 56: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – LONG AXIS IMAGE(S) – FOOTPRINT APPEARANCE

© 2018 Logan University, Department of Radiology

Page 57: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – LONG AXIS IMAGE(S)

Page 58: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – SHORT AXIS IMAGE(S)

DELTOID MUSCLE

BT

HUMERUS

Page 59: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Posterior rotator cuff - pathology

• Continuum: tendinosis (± enthesopathy, calcific tendinitis), partial tear, full-thickness tear, massive tear

• Tendinosis (Bretzke CA 1985, Crass JR 1988) :• Consider when > 6 mm

• Measured 1 cm proximal to insertion

• May be larger in athletes

• Contralateral comparison very helpful

© 2018 Logan University, Department of Radiology

Page 60: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Posterior rotator cuff - pathology

• Partial tear:• Articular sided

• Bursal sided

• Intrasubstance

• Ultrasound features (van Holsbeeck)• Hypoechoic or anechoic region, heterogeneous

• Irregular margin

• Focal thinning (i.e. loss of convex bursal contour)

• Bony irregularity

• Bursal fluid or fluid around biceps tendon

© 2018 Logan University, Department of Radiology

Page 61: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Posterior rotator cuff - pathology

• Ultrasound has 93% sensitivity and 94% specificity to diagnosis a full thickness rotator cuff tear (de Jesus JO, AJR Am J Roentgenol. 2009 Jun;192(6):1701-7.)

• Primary signs of full thickness tear: tendon absence (naked tuberosity), anechoic defect spanning bursal to articular surface, marked contour abnormality of the bursa/deltoid (van Holsbeeck)

• Secondary signs of full thickness tear: greater tubercle irregularity, effusion around biceps tendon, subdeltoid bursal fluid, cartilage interface sign

© 2018 Logan University, Department of Radiology

Page 62: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Full thickness v. massive tear

© 2018 Logan University, Department of Radiology

NORMAL FULL THICKNESS MASSIVE (THICKNESS + WIDTH)

Page 63: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Full thickness v. massive tear

© 2018 Logan University, Department of Radiology

NORMAL FULL THICKNESS MASSIVE (THICKNESS + WIDTH)

Page 64: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – TENDINOSIS

Page 65: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – CALCIFIC TENDINITIS

Page 66: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – CALCIFIC TENDINITIS

Page 67: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – ENTHESOPATHY

Page 68: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – PARTIAL THICKNESS TEAR

© 2018 Logan University, Department of Radiology

Page 69: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – PARTIAL THICKNESS TEAR

© 2018 Logan University, Department of Radiology

Page 70: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – FULL THICKNESS TEAR

© 2018 Logan University, Department of Radiology

Page 71: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – FULL THICKNESS TEAR

© 2018 Logan University, Department of Radiology

Page 72: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – MASSIVE TEAR

© 2018 Logan University, Department of Radiology

Page 73: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR ROTATOR CUFF – MASSIVE TEAR

Page 74: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

POSTERIOR GLENOHUMERAL JOINT

Page 75: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

POSTERIOR GLENOHUMERAL JOINT – DYNAMIC EVALUATION

Page 76: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

POSTERIOR GLENOHUMERAL JOINT – POSTERIOR LABRAL TEAR AND PARALABRAL CYST

NORMAL

Page 77: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

POSTERIOR LABRAL TEAR WITH PARALABRAL CYST

© 2018 Logan University, Department of Radiology

Page 78: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

SUPRASPINATUS MUSCLE – SHORT AXIS

Supraspinatus

Body of scapula

Page 79: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

SUPRASPINATUS MUSCLE – LONG AXIS

Scapula

Supraspinatus

Trapezius

Page 80: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

INFRASPINATUS MUSCLE – SHORT AXIS

Page 81: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

INFRASPINATUS MUSCLE – LONG AXIS

Page 82: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

© 2018 Logan University, Department of Radiology

MUSCLE ATROPHY

NORMAL

Page 83: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

References and recommended reading

• Jacobson JA. Fundamentals of Musculoskeletal Ultrasound, 3rd ed. Chapter 3 “Shoulder Ultrasound”.

© 2018 Logan University, Department of Radiology

Page 84: Ultrasound of the Shoulder · 2019-01-25 · •Hanusch et al. Biceps sheath fluid on shoulder ultrasound as a predictor of rotator cuff tear: analysis of a consecutive cohort. J

Thank you!

Questions, comments, concerns:

[email protected]