From most of the active surface 

From a small area in the center of the active surface 

From the edges of the active surface 

18 

The active element of most acoustic transducers used today is:  

Lithium 

Piezoelectric ceramic 

Sulfide 

Quartz 

19 

The act of evaluating and adjusting the precision and accuracy of themeasurement equipment is called: 

Standardization 

Calibration 

Accuracy Tuning 

20 

The ability to locate a small discontinuity is called: 

Resolution 

Sensitivity 

Wavelength 

Frequency 

21 What is used to support the active element and dampen thetransducers characteristics? 

Resin 

Oil Backing material with a similar the impedance of the transducer  Any of the above will work  

22 

In angle-beam testing, when the geometry of the part is relativelyuncomplicated and the orientation of a flaw is well known, the length

of a crack can be determined by a technique known as: 

Tip diffraction 

Immersion 

Surface mode diffraction 

Contact testing 

23 

The first critical angle describes the condition where the: 

Página 4 de 7Ultrasound Quiz 1

2007-11-02http://www.ndt-ed.org/EducationResources/CommunityCollege/Ultrasonics/Quiz/UTQui...

Page 5: Ultrasonic Questions 2.pdf

7/25/2019 Ultrasonic Questions 2.pdf

http://slidepdf.com/reader/full/ultrasonic-questions-2pdf 5/7

 

The angle of the refracted longitudinal wave is less than 90o 

The angle of the refracted longitudinal wave is exactly 90o 

The angle of the refracted longitudinal wave is greater than 90o 

The angle of the refracted shear wave is exactly 90o 

24 

In order to have a reasonable chance at detecting a discontinuity, thereflective surface of the discontinuity must have a dimension that is atleast as long as ________ wavelength. 

One-half  One 

Two 

0ne-quarter  

25 

Some transducers are specifically fabricated to be: 

Better transmitters 

Better receivers 

Used in high temperature applications 

All of the above 

26 

The sound energy or ultrasonic beam is more uniform in the: 

Far field zone 

 Near field zone 

Interface between the transducer and plastic wedge 

Band along the central axis 

27 

Which type of test block is used to check horizontal linearity and thedB accuracy per requirements of AWS and AASHTO? 

Distance/Sensitivity block  A DSC block  A rompus block  A shear wave calibration block  

28 

DACC stands for: 

Distance Amplitude Correction Curve 

Direct Application Correction Curve 

Distance Area Correction Calculation 

Distance Area Computer Controlled  

When a single element transducer is operating in the pulse echo

Página 5 de 7Ultrasound Quiz 1

2007-11-02http://www.ndt-ed.org/EducationResources/CommunityCollege/Ultrasonics/Quiz/UTQui...

Page 6: Ultrasonic Questions 2.pdf

7/25/2019 Ultrasonic Questions 2.pdf

http://slidepdf.com/reader/full/ultrasonic-questions-2pdf 6/7

29 mode, the element: 

Can not start receiving reflected signals until the element has stoppedringing from its transmit function 

 Needs to have a high pulse rate 

Should be used in the dual mode 

Can only be made with lithium sulfate 

30 

When a longitudinal wave encounters an interface between twomaterial with different accoustic impedances, what occurs when theangle of incidence is 90 degrees? 

Reflection 

Refraction 

Mode conversion 

Reflection and refraction 

31 

What is the correct formula for calculating the wavelength when thewave velocity and frequency are known? 

 None of the above 

32 

The material of the reference standard used to setup for a flawinspection: 

Can be made from similar material as long as the velocity is the same 

Should be the same material being inspected  Must have the same impedance values as the base material Can only be used once 

33 

A decibel is: 

A unit of measure used only for sound measurements 

A logarithmic unit that describes a ratio of two measurements  

A logarithmic unit that describes the product of two measurements 

 None of the above 

34 

What type of transducer contains two independently operatingelements in a single housing? 

Página 6 de 7Ultrasound Quiz 1

2007-11-02http://www.ndt-ed.org/EducationResources/CommunityCollege/Ultrasonics/Quiz/UTQui...

Page 7: Ultrasonic Questions 2.pdf

7/25/2019 Ultrasonic Questions 2.pdf

http://slidepdf.com/reader/full/ultrasonic-questions-2pdf 7/7

 

Crystal mosaic transducer  Dual element transducer  Liquid crystal transducer  Bi polar transducer  

35 

Mode conversion, occurs when a sound wave encounters an interfacebetween materials of different acoustic impedance and:

One of the two materials is a liquid  The incident angle is greater than the first critical angleThe incident angle is greater than the second critical angle 

The incident angle is not normal to the interface  