Ultrasonic Array Probe · Ultrasonic Array Probe ... The Latest Advanced Technology for Aiming of...

2
Ultrasonic Array Probe Linear Array Probe Matrix Array Probe Annual Array Probe Available for requests from customerSpecification Delivery time Design example of array probe Option Frequency 0.5~25MHz Numbers of elements 8~512 Element pitch 0.2mm ~ Connector Hypertronix ,Tyco,ITT Cannon ◦Extended & converted cable  Hypertronix ,Tyco,ITT Cannon ◦Shoes & wedges for array probe Material: polystyrene, acrylic resin & others Convertor & extended cable Concave type Hyper / fiber extension Hyper/ TYO conversion Angle shoe (polystyrene) Angle shoe (SX material) Array shoe ◦Multi-conductor cable ◦ 134 conductor / 68 conductor / 34 conductor / ◦ AWG 30/ 60/ 40 ◦ Provide the required shielded cable Item Specification 1 Frequency 5MHz 2 Numbers of element 128 3 Element pitch 1.0mm 4 Element size 0.9×10mm 5 Curvature R60 6 Case material SUS 7 Connector Hypertronix 8 Cable length 2m Connector name The delivery time is 1 month to 1 month & half. The Latest Advanced Technology for Aiming of Future Japan Probe Co, Ltd 232-0033 JP building 14-1-1 Nakamura Cyou Minami Ward Yokohama City Kanagawa Prefecture Japan Tel.045-242-0531, FAX.045-242-0541 http : //www.jp-probe.com E-mail:[email protected] Japan Probe Co, Ltd

Transcript of Ultrasonic Array Probe · Ultrasonic Array Probe ... The Latest Advanced Technology for Aiming of...

Page 1: Ultrasonic Array Probe · Ultrasonic Array Probe ... The Latest Advanced Technology for Aiming of Future 232-0033 JP building 14-1-1 Nakamura Cyou Minami Ward Japan Probe Co, Ltd

Ultrasonic Array ProbeLinear Array Probe Matrix Array ProbeAnnual Array Probe

【 Available for requests from customer】

Specification Delivery time

Design example of array probe

Option

Frequency 0.5~25MHzNumbers of elements 8~512Element pitch 0.2mm ~Connector Hypertronix ,Tyco,ITT Cannon

◦Extended & converted cable  Hypertronix ,Tyco,ITT Cannon◦Shoes & wedges for array probe Material: polystyrene, acrylic resin & others

Convertor & extended cable

Concave type

Hyper / fiber extension

Hyper/ TYO conversion

Angle shoe (polystyrene) Angle shoe (SX material)

Array shoe

◦Multi-conductor cable◦ 134 conductor / 68 conductor / 34 conductor /◦ AWG 30/ 60/ 40◦ Provide the required shielded cable

№ Item Specification 1 Frequency 5MHz2 Numbers of element 1283 Element pitch 1.0mm4 Element size 0.9×10mm5 Curvature R606 Case material SUS7 Connector Hypertronix8 Cable length 2m

Connector name

The delivery time is 1 month to 1 month & half.

The Latest Advanced Technology for Aiming of Future

Japan Probe Co, Ltd232-0033 JP building 14-1-1 Nakamura Cyou Minami WardYokohama City Kanagawa Prefecture JapanTel.045-242-0531, FAX.045-242-0541

http://www.jp-probe.com E-mail:[email protected]

Japan Probe Co, Ltd

Page 2: Ultrasonic Array Probe · Ultrasonic Array Probe ... The Latest Advanced Technology for Aiming of Future 232-0033 JP building 14-1-1 Nakamura Cyou Minami Ward Japan Probe Co, Ltd

Japan Probe Company provides the highest technology & high quality for array probes.

Materials

Character

Special array probe

Inspection

Example

Kinds

・ The material of element is 1-3 composite.

・We provide : The high quality & wide band wave form probe : Less deviation sensitivity.

・We provide the required array probes for user's purpose.

1D linear probe

SR linear probe 2D matrix probe Daisy probe Annual Probe

Concave probe Internal focused probe

Frequency(MHz)

Numbers of element Kinds Element pitch

P(mm)Element size

L×H(mm)Case dimension

(mm)

1 64 matrix probe 6.0 48×16 150×26×452 64 linear probe 2.5 160×20 180×28×353 32 focused probe 2.0 64×10 80×14×305 64 focused probe 1.0 64×10 80×14×307 128 Concave probe 0.6 77×8 94×18×82

7.5 128 linear probe 0.15 19.2×6 35×20×4210 64 Concave probe 0.32 20.5×10 54×16×3810 64 linear probe 0.6 38×10 50×50×4215 64 matrix probe 1.0 8×8 20×20×45

P P

H

L L

・ We design & provide various kinds probes for requirement.

High temperature array probeFlexible array probe

・ Flexible array probe & available for measurement in narrow place

・ Design of high temperature specification

・ High temperature wedge is used , available for measurement at 150℃

・High speed & reliable inspectionThe wave form pattern for data in all channels data is obtained & saved in pulser receiver & multiplexer, phased array equipment .

Frequency, sensitivity, band width

Wave form data

Data saving of personal computer

Pulser receiver

Phased array equipment

Multiplexer

Array probe Array probe

Composite element

Wave form pattern Central frequency Band width Sensitive deviationCentral frequency

band width