UIM Series Ultrasonic Flowmeter - Transus...

6
UIM-4F_technical_datasheet_rev02.docx UIM Series Ultrasonic Flowmeter UIM-4F Technical datasheet

Transcript of UIM Series Ultrasonic Flowmeter - Transus...

UIM-4F_technical_datasheet_rev02.docx

UIM Series Ultrasonic

Flowmeter

UIM-4F

Technical datasheet

UIM-4F_technical_datasheet_rev02.docx

Technical Data UIM-4F Principle of operation Broadband continuous wave – transit time

Sizes 150, 300 and 600lbs; 3 – 12”, other sizes on request

Flange type ANSI, DIN, others on request

Pressure ranges Up to 102 bar (1480 psi)

Ambient temperature -40 to +60°C (-40 to +140°F)

Process temperature -30 to +80°C (-22 to +176°F)

Typical uncertainty 0.5% (Qt – Qmax) factory calibration

1% Qmin – Qt) factory calibration

0.2% (Qt – Qmax) flow calibration

0.5% (Qmin – Qt) flow calibration

Metrology AGA-9 compliant

OIML R137-1&2 (Pending)

Repeatability 0.1%

Turndown 100:1 (pipe size dependent)

Meter body materials Carbon steel ASTM A350-LF2 Cl.1

Stainless steel ASTM A182-F316

Other materials on request

Material certification EN 10204 3.1

Pressure port ¼” NPT female

Electronic enclosure material Epoxy painted, low copper aluminum alloy

Electronic enclosure

cable entry

M20x1.5 female

1/2” NPT female

Power supply Main power: 18 – 28VDC, 670mW max

I/O option board power: 18 – 28VDC, 225mW max

User interface 128x128 dot matrix LC Display, 4 keys

Interface ports 1x USB (not intrinsically safe)

1x Frequency output

Optional interface ports Option board 1

1x RS485, two wire, externally powered

2x Digital, software configurable

Option board 2

Pressure and temperature sensors (pending)

Communication protocols MODBUS (RS485 and USB)

Hazardous area certification ATEX EX II 1 G Ex ia IIC T4 Ga, Zone 0

FM - Class I, Division 1, Group A,B,C,D T4 (pending)

Ingress Protection IP66, NEMA 4X

UIM-4F_technical_datasheet_rev02.docx

Flo

wra

ng

es

Turndown

Schedule Qmax Qt Qmin

40 77.9 610 61 9 68

80 73.7 540 54 10 54

40 102.3 1000 100 16 63

80 97.2 900 90 18 50

40 154.1 2000 200 27 75

80 146.3 1800 180 27 67

40 202.7 3500 350 35 100

80 193.7 3200 320 37 87

40 254.5 5500 550 55 100

80 242.9 5100 510 51 100

40 303.2 7800 780 78 100

80 289.0 7100 710 71 100

Turndown

Schedule Qmax Qt Qmin

40 3.068 21,230 2,123 310 69

80 2.900 18,970 1,897 330 58

40 4.026 34,980 3,498 540 65

80 3.826 31,600 3,160 630 51

40 6.065 70,620 7,062 940 76

80 5.761 63,290 6,329 940 68

40 7.981 123,510 12,351 1,240 100

80 7.625 112,740 11,274 1,280 89

40 10.020 194,100 19,410 1,950 100

80 9.564 176,800 17,680 1,770 100

40 11.938 275,430 27,543 2,760 100

80 11.376 250,200 25,020 2,510 100

Flo

wra

ng

es

me

tric

Imp

eri

al

Flow [CFH]

3

4

6

Internal

diameter

[inch]

Flow [m3/hr]Internal

diameter

[mm]

10

6

8

Nominal

Size

[inch]

3

4

12

10

12

8

Nominal

Size

[inch]

UIM-4F_technical_datasheet_rev02.docx

150 300 190 372 35

300 300 210 382 36

600 350 210 382 38

150 350 230 410 56

300 350 255 422 60

600 400 275 447 81

150 350 280 457 57

300 350 320 477 74

600 400 355 510 120

150 400 345 515 86

300 500 380 532 175

600 500 420 570 192

300 550 445 610 245

600 550 510 640 295

300 600 520 675 285

600 600 560 695 365

150 11.8 7.5 14.6 77

300 11.8 8.3 15.0 79

600 13.8 8.3 15.0 84

150 13.8 9.1 16.1 123

300 13.8 10.0 16.6 132

600 15.7 10.8 17.6 179

150 13.8 11.0 18.0 126

300 13.8 12.6 18.8 164

600 15.7 14.0 20.1 265

150 15.7 13.6 20.3 190

300 19.7 15.0 20.9 386

600 19.7 16.5 22.4 423

300 21.7 17.5 24.0 540

600 21.7 20.1 25.2 650

300 23.6 20.5 26.6 628

600 23.6 22.0 27.4 805

Rating

12

Nominal

Size

[inch]

Rating

12

Nominal

Size

UIM

-4F

Dim

en

sio

ns

4

6

8

10

3

3im

pe

ria

lm

etr

ic

4

6

8

10

A- Length

[mm]

B- Width

[mm]

C - Height

[mm]

Weight

[kg]

A- Length

[mm]

B- Width

[mm]

C - Height

[mm]

Weight

[kg]

Flo

wm

eter Dim

ensio

ns

UIM-4F_technical_datasheet_rev02.docx

Installation configurations

Configuration 1. – Conservative configuration with flow conditioner Configuration 2. – Recommended configuration with flow conditioner Configuration 3. – Recommended configuration without flow conditioner For bi-directional flow;

The upstream piping spools and flow conditioner as applicable from configurations 1, 2 and 3 can be used on both ends of the metering package.

Any thermowell should be positioned 3 – 5 diameters away from meter flanges

Installatio

n C

on

figu

ration

s

UIM-4F_technical_datasheet_rev02.docx

Asia, Pacific & Americas Transus Instruments Pty Ltd 403 Huon Road South Hobart Tasmania, Australia 7004 T: +61 (0)3 6223 7105 [email protected] Europe, Middle East & Africa Transus Instruments BV Duikerweg 37 3897LM Zeewolde The Netherlands T: +31 (0)36 737006 [email protected] www.transus-instruments.com