UFT55-12 Physical Specification - ultracell.co.ukultracell.co.uk/datasheets/UFT55-12.pdf · 277 2 2...

2
277 2 118.5 222 2 210 2 207 2 50 106 2 16 M6 1 3 ISO9001 UFT55-12 12V 55AH Front Terminal UFT55-12 Physical Specification Part Number UFT55-12 Length 277 ± 2 mm Width 106 ± 2 mm Container Height 222 ± 2 mm Total Height (with terminal) 222 ± 2 mm Approx Weight 18 kg Specifications Nominal Voltage 12V Nominal Capacity (10HR) 55AH Terminal Type Standard Terminal F6 Container Material Standard Option ABS Flame Retardant Option (FR) UL94-V0 Rated Capacity 20hr, 1.80V/cell, 25°C 60.4 AH/3.02A 10hr, 1.80V/cell, 25°C 57.1 AH/5.71A 5hr, 1.75V/cell, 25°C 48.2 AH/9.64A 3hr, 1.75V/cell, 25°C 43.5AH/14.5A 1hr, 1.60V/cell, 25°C 39.1 AH/39.1A Max Discharge Current 550A (5s) Internal Resistance Approx 6.0m Discharge Characteristics Operating Temp. Range Discharge: -15 ~ 50°C Charge: 0 ~ 40°C Storage: -15 ~ 40°C Nominal Operating Temp. Range 25 ± 3°C Cycle Use Initial Charging Current less than 16.5A Voltage 14.4V ~ 15.0V Temp. Coefficient -30mV/°C Standby Use No limit on Initial Charging Current Voltage 13.5V ~ 13.8V Temp. Coefficient -20mV/°C Capacity affect by Temperature 40°C 103% 25°C 100% 0°C 86% Design Floating Life at 20°C 12+ Years Self Discharge Ultracell batteries may be stored for up to 6 months at 25°C(77°F) and then a refresh charge is required. For higher temperatures the time interval will be shorter. Dimensions F6 Terminal 1 Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United Kingdom Tel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: [email protected] www.ultracell.co.uk Revised: 23 Oct 2014 ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE

Transcript of UFT55-12 Physical Specification - ultracell.co.ukultracell.co.uk/datasheets/UFT55-12.pdf · 277 2 2...

Page 1: UFT55-12 Physical Specification - ultracell.co.ukultracell.co.uk/datasheets/UFT55-12.pdf · 277 2 2 118.5 2 2 M 2 2 1 0 1 2 2 0 7 2 5 0 0 6 2 16 6 1 3 ISO9001 UFT55-12 12V 55AH Front

277 2118 .522

2 2

210

220

7 2 50

106

2

16M6

1 3

ISO9001

UFT55-1212V 55AHFront Terminal

UFT55-12 Physical Specification

Part Number UFT55-12

Length 277 ± 2 mm

Width 106 ± 2 mm

Container Height 222 ± 2 mm

Total Height (with terminal) 222 ± 2 mm

Approx Weight 18 kg

SpecificationsNominal Voltage 12V

Nominal Capacity (10HR) 55AH

Terminal Type Standard Terminal F6

Container Material Standard Option ABS

Flame Retardant Option (FR) UL94-V0

Rated Capacity 20hr, 1.80V/cell, 25°C 60.4 AH/3.02A

10hr, 1.80V/cell, 25°C 57.1 AH/5.71A

5hr, 1.75V/cell, 25°C 48.2 AH/9.64A

3hr, 1.75V/cell, 25°C 43.5AH/14.5A

1hr, 1.60V/cell, 25°C 39.1 AH/39.1A

Max Discharge Current 550A (5s)

Internal Resistance Approx 6.0m

Discharge Characteristics

Operating Temp. Range

Discharge: -15 ~ 50°C

Charge: 0 ~ 40°C

Storage: -15 ~ 40°C

Nominal Operating Temp. Range

25 ± 3°C

Cycle Use

Initial Charging Current less than 16.5A Voltage14.4V ~ 15.0V Temp. Coefficient -30mV/°C

Standby Use

No limit on Initial Charging Current Voltage13.5V ~ 13.8V Temp. Coefficient -20mV/°C

Capacity affect by Temperature

40°C 103%

25°C 100%

0°C 86%

Design Floating Life at 20°C 12+ YearsSelf Discharge Ultracell batteries may be stored for up to 6 months at 25°C(77°F) and then a refresh charge is required.

For higher temperatures the time interval will be shorter.

Dimensions

F6 Terminal

1 Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United KingdomTel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: [email protected]

Revised: 23 Oct 2014ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE

Page 2: UFT55-12 Physical Specification - ultracell.co.ukultracell.co.uk/datasheets/UFT55-12.pdf · 277 2 2 118.5 2 2 M 2 2 1 0 1 2 2 0 7 2 5 0 0 6 2 16 6 1 3 ISO9001 UFT55-12 12V 55AH Front

100.1 2 4 6 20 40 60 2 4 6 8 103.5

4.0

4.5

5.0

5.5

6.0

6.5

7.0

8.0

9.0

10.0

11.0

12.0

13.0

HMin

0.104CA0.228CA0.39CA

0.692CA1.187CA2.5CA

6CA

V V

6VBat tery

12VBat tery

0Temperature:25 C

Term

inal V

oltag

e(V)

Discharge Time0 4 8 12 16 20 24 28

Charging Time(hours)32 36

2.0

2.1

2.2

2.3

2.4

(V/cell)(A)

0.02C

0C

0.04C

0.06C

0.08C

0.10C

%

20

40

60

80

100

120

ChargeVolume

Charging Current

Charging Voltage

After 50% Discharge

After 100% Discharge

Charge Voltage(Constant 2.25V/cell)

Charged Volume

Charging Current

00.1CA-2.25V/cell temperature 25 C

1CA

0.65CA

0.28CA

0.125CA

Capa

city

%

0

20

40

60

80

100

120

-20 -10 0 10 20 30 40 500Temperature( C)

8 10 120

4 6

60

80

100

0 2

20

40

025 C

030 C040 C

010 C A

B

C

Storage Time (Months)

)%( yticapa

C gni ni ame

R

A

B

C

1.85V/cell1.80V/cell1.75V/cell1.70V/cell1.67V/cell1.60V/cell

F.V/Time 10min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h20min95.7 79.7 68.4 53.7 41.6 33.8 20.2 14.5 11.7 9.66 8.40 6.54 5.46 2.89108.4 88.9 75.7 58.7 44.8 36.1 21.3 15.5 12.3 10.2 8.83 6.88 5.71 3.02119.0 96.2 80.8 61.7 46.5 37.4 21.7 15.7 12.6 10.4 8.97 6.96 5.78 3.07127.3 101.3 84.1 63.5 47.6 37.9 22.0 15.9 12.7 10.5 9.08 7.06 5.83 3.09131.7 103.8 85.8 64.3 47.7 38.1 22.1 16.0 12.8 10.6 9.19 7.15 5.89 3.11138.5 107.8 89.7 65.9 49.0 39.1 22.4 16.3 13.0 10.8 9.35 7.32 6.00 3.12

F.V/Time1.85V/cell1.80V/cell1.75V/cell1.70V/cell1.67V/cell1.60V/cell

10min 15min 30min 45min 1h 2h 3h 4h 5h 6h 8h 10h 20h20min178.6 150.4 130.4 103.4 80.8 65.9 39.6 28.6 23.0 19.1 16.7 13.05 10.9 5.79200.1 165.4 142.2 111.4 86.3 70.0 41.5 30.3 24.1 20.0 17.5 13.67 11.4 6.04216.1 176.8 150.3 116.1 88.7 72.2 42.1 30.6 24.6 20.4 17.7 13.80 11.5 6.12226.0 183.7 155.2 118.8 90.4 72.9 42.6 30.9 24.8 20.5 17.9 13.99 11.6 6.16233.0 187.4 157.8 120.1 90.5 73.0 42.7 31.0 24.9 20.7 18.0 14.15 11.7 6.19238.2 190.8 162.5 121.5 91.9 74.2 43.0 31.4 25.3 21.1 18.3 14.43 11.9 6.21

ISO9001

UFT55-1212V 55AHFront Terminal

Constant Current Discharge (Amperes) at 20°C

Constant Power Discharge (Watts) at 20°C

Discharge Characteristics

Float Charging Characteristics

Temperature Effects in Relation to Battery Capacity

Effect of Temperature on Long Term Float Life

Self Discharge Characteristics

A No supplementary charge required(Carry out supplementary charge before use if 100% capacity is required.)

B Supplementary charge required before use. Optional charging way as below:1.Charged for above 3 days at limited current 0.25CA and constant voltage 2.25V/cell.2.Charged for above 20hours at limited current 0.25CA and constant voltage 2.45V/cell.3.Charged for 8~10hours at limited current 0.05CA.

C Supplementary charge may often fail to recover the capacity.The battery should never be left standing till this is reached.

2 Ultracell (UK) Ltd | Vesty Business Park, Vesty Road, Liverpool, L30 1NY, United KingdomTel: +44 (0) 151 523 2777 | Fax: +44 (0) 151 523 0855 | Email: [email protected]

Revised: 23 Oct 2014ALL DATA IS SUBJECT TO CHANGE WITHOUT NOTICE

0.5

Battery temperature

2

5

8

12

15

18

Charging voltage2.25V/cell

Life

expe

ctan

cy(y

ear)

2068

0C3086

40104

50122 OF