UFAD
schneider-electric.com
Underfloor air distribution system:Bring value to the evolving office space.
998-19688032_GMA-US.indd 1 3/9/16 12:02 PM
schneider-electric.com 3
Total employee care, improved productivity.
Bring value to the evolving office space
0%wasted space
20+%saved energy
40%faster construction time
100%flexibility
>comfort and aesthetic
When you are asked to design and implement a system
made of different, interacting technologies, having a single,
trusted solution provider is the key to success.
management
HVAC/UFADoptimization
Zonecontrol
AF and integratedair booster
Air conditioning unit Heat pump/chiller Air handling unit
Forecasting
Calendar
Comfort level
Energy
21
998-19688032_GMA-US.indd 2-3 3/9/16 12:02 PM
schneider-electric.com 5schneider-electric.com4
Do more with less
There’s something about UFAD system air
that just feels right. Optimization of energy and
space, faster construction time, more flexibility.
Underfloor air distribution system1. Energy saving
UFAD reduces energy consumption by over 20% compared to traditional overhead systems thanks to:
• Lower fan pressures required to deliver air in a room
• Warmer supply temperature because air is supplied close to occupants and not from the ceiling
• Efficient supply/return air flows that prevent short cycling of the supply air back to the returns
2. Comfort
The increased well-being of office occupants translates to a more productive working environment:
• The natural convective flow activated by the human body heat moves the conditioned air up, pulling CO
2
and humidity toward the return plenum
• Unlike overhead systems, UFAD system air is always supplied at a comfortable temperature, without high-speed air jets
• A closer temperature control can be obtained by installing air boosters in separate rooms or in areas exposed to solar radiation
3. Flexibility
• System components are integrated into the modular access floor without the use of ductwork, this way they can be easily moved to accommodate changes in the room layout
4. Increased available space
• The height of each floor can be reduced by 10%; for example, a 40 m high building can have 11 floors instead of 10
• The access floor plenum is not only used for air conditioning but also other infrastructure, like electrical and hydraulic systems
5. Faster construction time
• No need to build dedicated ductwork as the ceiling and floor plenums are used as air ducts
• The system design and construction is faster: 40% of time is saved compared to traditional solutionEnergy Flexibility Time Comfort
998-19688032_GMA-US.indd 4-5 3/9/16 12:02 PM
schneider-electric.com 7schneider-electric.com6
Whatever your UFAD concept, we have your solution
UFAD system uses the space between the structural
concrete slab and the underside of a raised access floor
to deliver conditioned air directly into the occupied zone of
the building. This principle can be developed in different
configurations according to the customer’s needs and
project requirements.
1
2 Zero-pressure configuration
In this configuration the central air handling unit delivers conditioned air to the underfloor plenum, but in this case the plenum is maintained at very nearly the same pressure as the conditioned space. Active fan-powered diffusers supply the air into the occupied zone of the space.
1 Pressurized plenum configuration
This configuration consists of an air handling unit delivering air through the underfloor plenum, maintaining a pressure that allows air to be delivered into the space through passive floor air diffusers.
Fan-powered air diffusers (UTCT) can be integrated in closed meeting rooms and offices where the temperature requires rapid and personalized adjustments.
2
998-19688032_GMA-US.indd 6-7 3/9/16 12:02 PM
schneider-electric.com 9schneider-electric.com8
Air handling units Air conditioning units
Model Air flow cm/h (cfm)
Noise level dB(A)*
AHVS3000 5.097 (3.000) 46
AHVS6500 11.043 (6.500) 48
AHVS12000 20.388 (12.000) 50
Frame
• Self-supporting frame in galvanized steel
• Double skin panels with sound-proofing insulation
• Front access for maintenance
Fans
• New generation radial EC fans for maximum efficiency
• Impellers made of high-tech compound material with optimized flow control
• Acousti-Composite fans with low acoustic impact
• Rubber anti-vibrating elements
Coil
• Copper tubes mechanically expanded with hydrophilic treatment
• Dehumidification function and reduced pressure drop
Filters
• High-efficiency filters MERV8/EU4 and MERV13/EU7
• Filter clog detection
Microprocessor control
• Advanced microprocessor control system included with local or remote user terminal
• Modbus RTU, Modbus TCP/IP, BACnet, Lonworks, Web server on board, Micro USB, USB, Micro SD
Model Air flow cm/h (cfm)
Noise level dB(A)*
TDCV LN 0700 5.600 (3.296) 45
TDCV LN 1200 8.500 (5.300) 46
TDCV LN 1700 12.000 (7.063) 48
TDCV LN 2700 15.300 (9.005) 48
TDCV LN 4000 19.000 (11.183) 50
Frame
• Modular, separable structure for easier movement
• Aluminum modular profiles with plastic corners
• Double skin panels with mineral sound-proofing insulation
• Drawer fan section
• Bypass section with motorized damper
• Safety switches
• Marine lamp
Fans
• New generation radial EC fans for maximum efficiency
• Impellers made of high-tech compound material with optimized flow control
• Acousti-Composite fans with low acoustic impact
• Rubber anti-vibrating elements
Coil
• Copper tubes mechanically expanded with hydrophilic treatment
• Dehumidification function and reduced pressure drop
• Front access for maintenance
Filters
• High-efficiency filters MERV8/EU4 and MERV13/EU7
• Filter clog detection
Microprocessor control
• Advanced microprocessor control system included with local or remote user terminal
• Modbus RTU, Modbus TCP/IP, BACnet®, Lonworks, Web server on board, Micro USB, USB, Micro SD
Chilled water AHVS range
AHVS units treat and distribute the cooled air under the access floor. This compact and very low noise unit, normally located in a technical room, mixes fresh air with ambient return air. Thanks to the bypass on return air, it allows perfect temperature control of the supply air and energy recovery.
Chilled water TDCV LN range
This compact and very low noise unit can be placed in technical rooms, aisles, or in the working space. Fresh air is provided by an external air handling unit. The internal TDCV unit mixes the fresh air and the ambient return air, cools or heats it, and delivers it under floor at the desired temperature conditions.
Three- sectionframe
20%energy saving with EC fans
30%bypass air
<50 dB(A) sound pressure
*Data measured at 1 m from front of unit, 1.2 m high from floor
* Data measured at 1 m from front of unit, 1.2 m high from floor, with sound-proofing plenum on unit suction
998-19688032_GMA-US.indd 8-9 3/9/16 12:02 PM
schneider-electric.com 11schneider-electric.com10
Frame
• Self-supporting frame in galvanized steel
Fans
• Dual electronic motor centrifugal fan, manufactured in PP, complying with standard EN60335-1
• Modulating motorized air damper for air recirculation (from 0% to 100%)*
Electrical heater
• Optional aluminum fins electrical heater with safety thermostat and automatic restart*
Filter
• Cleanable filter in self-extinguishing material with galvanized plate edge*
Microprocessor control
• Advanced microprocessor control system is included with local or remote user terminal for manual or automatic operation
• Modbus RTU
*UTCT only
Frame
• Self-supporting frame in galvanized steel
Fan
• Dual electronic motor centrifugal fan, manufactured in PP, complying with standard EN60335-1
• Modulating motorized air damper (from 0% to 100%)
Microprocessor control
• Advanced microprocessor control system is included with local or remote user terminal for manual or automatic operation
• Ability to interface with modbus protocol directly on RS485 serial card and with main external communication protocols: BANnet, Lonworks, Trend, Metasys, TCP/IP, SNMP, and StruxureWareTM platform
Air boosters and fan power boxes Water chillers and heat pumps
Fans
• New generation radial EC fans for maximum efficiency
• Impellers made of high-tech compound material with optimized flow control
• Acousti-Composite fans with low acoustic impact
Compressors
• Inverter-driven scroll or oil-free centrifugal compressors to optimize energy consumption and provide a high level of reliability
• Tandem scroll compressors to increase efficiency by utilizing an oversized coil for one compressor during part-load operation
• Completely isolated sound-proofing enclosures for compressors
Microprocessor controller
• Microprocessor controller allows unit to restart without intervention after a power failure
• Operation mode and room conditions viewed through user-friendly navigation with icon displays
• Communication with multiple building management system protocols
Aquaflair WC
Water-cooled
Aquaflair DF
Air-cooled
ducted fans
Aquaflair AC
Air-cooled
UTCT0600
ModelMin under floor height (mm)
Nominal Air flow (m3/h)
Max Noise dB(A) 1 m
UTCT0600
Slim160 360 45
UTCT0600 280 400-900 47
ModelMin under floor height (mm)
Nominal Air flow (m3/h)
Max Noise dB(A) 1m
UTFB600 280 680 47
Acquaflair VersionsCapacity Range (kW)
Air-cooled Cooling only
Cooling/heat pump
50 – 1200
Water-cooled Cooling only
Cooling/heat pump
50 – 1200
Air-cooled ducted
fans
Cooling only
Cooling/heat pump
50 – 100
Underfloor
air distribution
module
UTCT range
In single offices, where highly personalized comfort regulation is required, or in meeting rooms where load changes must be rapidly accommodated, UTCT underfloor air boosters allow to locally force or post-treat air in total cooling/heating, recirculation, or mixed operating modes.
Underfloor
fan power box
UTFB range
In buildings with glass walls exposed to solar radiation, air is delivered through the linear grills placed along the glass wall and pressurized by the fan power box.
UTFB600
UTCT0600 slim
High efficiency chillers and heat
pumps Aquaflair range
AquaflairTM chillers and heat pumps are all-in-one for easy design and installation, and completely configurable to guarantee use in multiple applications and environmental conditions.
30%energy saving with variable
speed technology
X3air flow for small rooms
and façade air boosting
998-19688032_GMA-US.indd 10-11 3/9/16 12:03 PM
schneider-electric.com 13schneider-electric.com12
Uniflair access floor — Made in Italy
UniflairTM access floor is a key element of a UFAD system: it allows underfloor air distribution and enables the placement of the main building systems (electrical, electronics, hydraulics) in the plenum underneath, leaving creative space for designers and architects. It also guarantees immediate access for maintenance and total layout flexibility.
Aesthetics
• In-factory finishing in infinite variants, including: natural stone, marble, ceramic, wood, vinyl, HPL, rubber
• Back-lightened logo tiles
• Glass tiles
• Customized sizes up to 1200 mm
Mechanical features
• Bare panels
• Resistant to site works
• Washable
• Perfect flatness for carpet finishing
• Modular, accessible
• Optimal acoustic performances
• Low air leakage
• Easy to cut
• Top load capacity up to extra heavy grade
Fire resistance
• Excellent thermal insulation
Access floor SmartStruxure
30%energy saving
with SmartStruxure
40%Construction time saving vs
traditional floor
SmartStruxure integrated
building management
The SmartStruxureTM solution enables you to monitor, measure, and optimize your building’s performance throughout its life cycle — saving you money. You can’t control what you don’t measure. The SmartStruxure solution, powered by StruxureWare building operation software, facilitates the exchange and analysis of data from energy, lighting, fire safety, and HVAC.
Simple
• Personalized user interface
• Anytime, anywhere access
• Simplified day-to-day operations
Smart
• Scalable system based on open protocols
• Key component of an integrated enterprise
• IT-friendly and secure
Performing
• Optimized building performance
• Facility comfort and value
• Actionable intelligence
2 3 154
6
7 8
Note
1 Finishing
2 Core
3 Perimeter edge
4 Backing
5 Head gasket
6 Pedestal
7 Stringer gasket
8 Stringer
schneider-electric.com/smartstruxure
998-19688032_GMA-US.indd 12-13 3/9/16 12:03 PM
schneider-electric.com14
Our technologies ensure that Life Is On everywhere, for everyone, and at every moment.
Note
Directly impacted by Schneider Electric
Rating components
LEED v3 for New Construction and Major Renovation
Sustainable Sites 26 Points
Construction Activity Pollution Prevention Required
Site Selection 1
Development Density and
Community Connectivity5
Brownfield Redevelopment 1
Alternative Transportation 12 max
Site Development 2 max
Stormwater Design 2 max
Heat Island Effect — Nonroof and Roof 1 each
Light Pollution Reduction 1
Water Efficiency 10 Points
Water Use Reduction — 20% reduction Required
Water Efficient Landscaping 4 max
Innovative Wastewater Technologies 2
Water Use Reduction 4 max
Innovation in Design 6 Points
Innovation in Design 5 max
LEED Accredited Professional 1
Regional Priority 4 Points
Specific Credit 4
Energy and Atmosphere 35 Points
Fundamental Commissioning of the Building
Energy SystemsRequired
Minimum Energy Performance Required
Fundamental Refrigerant Management
RequiredRequired
Optimize Energy Performance 19 max
On-Site Renewable Energy 7 max
Enhanced Commissioning 2
Enhanced Refrigerant Management 2
Measurement and Verification 3
Green Power 2
Materials and Resources 14 Points
Storage and Collection of Recyclables Required
Building Reuse 4 max
Construction Waste Management 2 max
Materials Reuse 2 max
Recycled Content 2 max
Regional Materials 2 max
Rapidly Renewable Materials 1
Certified Wood 1
Indoor Environmental Quality 15 Points
Minimum Indoor Air Quality Performance Required
Environmental Tobacco Smoke Control Required
Outside Air Delivery Monitoring 1
Increased Ventilation 1
Construction Indoor Air Quality
Management Plan 2 max
Low-Emitting Materials 4 max
Indoor Chemical
and Pollutant Source Control 1
Controllability of Systems —
HVAC and Lighting 1 each
Thermal Comfort 2 max
Daylight and Views 2 max
998-19688032_GMA-US.indd 14-15 3/9/16 12:03 PM
Schneider Electric
Head Office35 rue Joseph Monier92500 Rueil Malmaison Cedex – FranceTel.: +33 (0)1 41 29 70 00
Conselve OfficeViale della Tecnica, 235026 Conselve (PD) – ItalyTel.: +39 049 5388211
www.schneider-electric.com
March 2016
©2016 Schneider Electric. All Rights Reserved.Schneider Electric, StruxureWare, Aquaflair, Uniflaid, SmartStruxure, and Life Is On Schneider Electric are trademarks and the property of Schneider Electric SE, its subsidiaries and affiliated companies. All other trademarks are the property of their respective owners. 998-19688032_GMA-US