Ucs & v mware integrated mgmt roger_barlow
-
Upload
cisco-data-center-sdn -
Category
Technology
-
view
289 -
download
5
Transcript of Ucs & v mware integrated mgmt roger_barlow
1© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 1
UCS & VMware Integrated ManagementRoger BarlowUCS Product Manager
Co-Sponsored by Intel®
2© 2013 Cisco and/or its affiliates. All rights reserved.Presentation_ID Cisco Public
UCS Is To Physical As VMware Is To Virtual
• Single point physical infrastructure management• Fully capable XML API• Policy based configuration management• Template based configurations• OS migration between physical
servers
Network Integration of UCS Manager and VMware vCenter
• No other joint solution moves network QoS and security settings with virtual machines, automatically and simultaneously.
• Integrated port profiles and port groups reduce chance of error and increase security, eliminating downtime.
VM-FEX virtual machines appear in the Virtual Machines tab in UCS-M
UCSM VM-FEX Integration
UCS & VMware Auto Deploy
Automated Provisioning of Hypervisors
• VMware Host Profiles completely define the hypervisor configuration
• Cisco UCS Service Profiles completely define the physical server configuration
• Autodeploy enables network based provisioning/booting of hypervisors
• UCS Autodeploy integration allows for one click provisioning of fully configured hypervisors
Without UCS
Associate boot image one server at a time
UCS Enhanced Auto Deploy
Automatically associate boot image
UCS & Auto Deploy Operational SimplificationProfile-Based Provisioning Integrated with vSphere 5
VMware vSphere 5 Auto Deploy• Boot servers over IP networks using shared
storage• Link each new physical server to a vCenter
boot image
Server #1
Select a server: go to server element manager, find server, copy MAC address
Find Auto-Deploy image: go to vCenter, select image, enter server MAC address
Boot server
Server #2
Select a server: go to server element manager, find server, copy MAC address
Find Auto-Deploy image: go to vCenter, select image, enter server MAC address
Boot server
Server #3
Select a server: go to server element manager, find server, copy MAC address
Find Auto-Deploy image: go to vCenter, select image, enter server MAC address
Boot server
Server #...
Select a server: go to server element manager, find server, copy MAC address
Find Auto-Deploy image: go to vCenter, select image, enter server MAC address
Boot server
Server #1
Link vCenter boot image to service profile template
Deploy new server
Server #2
Select template Deploy new server
Server #3
Select templateDeploy new server
Server #...
Select templateDeploy new server
UCS enhanced Auto Deploy
• Link service profile template to a vCenter boot image
• Deploy many vSphere servers with a single click
• Policy enforced: saves time and reduces errors
UCS vCenter Orchestrator Plug-In
Cisco release
Auto-derived from the existing UCS XML-API
Automates frequently performed administrative UCS tasks
Integrate physical infrastructure management into VMware’s virtual infrastructure management tools
FeaturesFeatures
UCS Plugin for vCenter
A plugin to the VMware vCenter web console that gives virtualization administrators direct management of UCS hardware from within the vCenter console
View physical infrastructure from within vCenter
Correlate virtual and physical resources
Quick access to KVM, UCSM, & LED indicator
Released CQ3 2012
Cisco UCS vCenter Plugin Phase I
Provide a single point of administration for both physical and virtual infrastructure
Streamline infrastructure management by tracking virtual & physical relationships
Extend vCenter visibility into Cisco’s advanced virtual networking technologies (VMFex, Virtual Interface Card, etc)
Together ESX & UCS:
1. AutoDeploy UI2. Apply Service Profile Template3. Create Service Profile Template from hypervisor4. Clone hypervisor5. Add/Create VLAN to UCSM6. Add/create VIC interface on blade7. Upgrade blade firmware8. Virtualization specific BIOS settings
• Intel VT• Hyper threading• etc
vCenter Plugin Phase II
Cisco UCS vCenter Plugin Phase II (Q3 2013)
Provide a single point of administration for both physical and virtual infrastructure
Manage and provision physical infrastructure (network, compute, and SAN) without leaving vCenter
Together ESX & UCS:
LogInsight UCS Content Pack
A plugin to the VMware's LogInsight product that collects information and events from the Fabric Interconnect and provides analytics on the information collected including:
FI, IOM, & FEX events
Blade & Managed Rack events
UCS Domain events
UCS Central events
CQ3 2013 Availability
VMware LogInsight Content Pack (Q3 2013)
Provide a comprehensive view of infrastructure activity
Simplify data collection from Network, Compute, & storage by providing a single data source
Shorten troubleshooting time for the entire UCS infrastructure
Together UCS & LogInsight:
Infrastructure - VCE Vblock
VblockTM Infrastructure PlatformsManagement and Orchestration: Unified Infrastructure Manager (UIM) frameworkVirtualization: VMwareCompute: Cisco UCSNetwork: Cisco Nexus and MDS switchingStorage: EMC Symmetrix VMAX or Unified
Solutions and ServicesAccelerate time to value of business applicationsSeamless Support
Infrastructure - Flexpod
Dev/Test
Starting Out
DP/ Backup
More computeLess storage
Less computeMore storage
Entry systemThen scale up
VDI
Higher performanceblades, more IOPS
ProductionInfrastructure
IOPS
CPU
CapacityMemory
ProductionBalanced
Infrastructure
Nexus 5xxx series switches
UCS B-Series Servers
Memory countProcessor speedsTotal server count
NetApp FAS controller
Add-on cardsExpansion modulesFlash Cache
Shelves and drives types
Shelf countDrive types – SAS, SATA, FC, SSDDrive sizes – 450GB, 600GB, 1TB, etc.
Why is Cisco best for Desktop Virtualization?-Streamlined Manageability
VDI Can Be Complex – You Need Streamlined, QoS-Enabled Infrastructure
•Combines multiple disparate technologies working in concert – compute, storage, software, network, security
•Cisco UCS with VM-FEX offers granular QoS controls for virtual desktop pools
•Cisco UCS Manager in concert with VMware management tools along with a rapid, stateless provisioning model
VMware VDI Bundle
Desktop Virtualization Starter Kit for View
(2) UCS 6248UP Interconnects
(1) UCS Chassis w/ two 2208 FEX
(1) UCS B200 Management Blade:•CPU: 2 x 2.40 GHz E5-2665 •Mem: 8 x 16GB (128GB) •HDD: 300GB SAS •VIC 1240
(3) B200 Desktop Workload Blade•CPU: 2 x 2.70 GHz E5-2680 •Mem: 16 x 16GB (256GB)•HDD: 300GB SAS•VIC 1240
(3) 100 View Premier Pack
UCS-EZ-VDI-ENT-VW
Desktop Virtualization for SMB with View
(1) UCS C240 M3 Rack Server:•CPU: 2 x 2.90 GHz E5-2690 •Mem: 16 x 16GB (256GB)•RAID: MegaRAID 9266CV-8i•VIC 1225 •24 x 600G SAS 10K RPM SFF HDD(1)100 View Premier Pack
UCS-EZ-VDI-SMB-VW
Expansion Bundle for View
(1) UCS B200 M3 Blade:•CPU: 2 x 2.70 GHz E5-2680 •Mem: 16 x 16GB (256GB)•HDD: 300GB SAS•VIC 1240
(1)100 View Premier Pack
UCS-EZ-VDI-EXP-VW
Upgrade Option 24 x 16GB Memory (64GB):
UCS-EZ-M16GB-4PK
Upgrade Option 1UCS Storage Accelerator: Fusion-io ioDrive2 MLC - 785GB UCSB-F-FIO-785M Desktop Virtualization for Remote
Office / Branch Router
(1) UCS E-Series ISR G2(1)25 View Pack
UCS-E160D-M1VDI/K9
Desktop Virtualization for Remote Office / Branch Router
(1) UCS E-Series ISR G2(1)25 View Pack
UCS-E160D-M1VDI/K9
Cisco UCS Validated Designs with VMWare
Name Posted URL
Sharepoint on FlexPod w/ vSphere 5.0 3/12 http://www.cisco.com/en/US/docs/unified_computing/ucs/UCS_CVDs/ucs_sharepoint2010_flexpod_vmware.html
HDS w/ vSphere 5.0 10/12 http://www.cisco.com/en/US/docs/unified_computing/ucs/UCS_CVDs/ucs_hds.html
FlexPod w/ vSphere 5.0 10/12 http://www.cisco.com/en/US/docs/unified_computing/ucs/UCS_CVDs/flexpod_50_M3.html
Citrix XD 5.6 on vSphere 5.1 1/13 http://www.cisco.com/en/US/docs/unified_computing/ucs/UCS_CVDs/citrix_emc_ucs_scaleVDI.pdf
VSPEX: View 5.1.2 for 2000 users 1/13 http://www.cisco.com/en/US/docs/unified_computing/ucs/UCS_CVDs/ucs_vspex_vview2000.pdf
VSPEX: View 5.1.2 for 500 users 5/13 http://www.cisco.com/en/US/docs/unified_computing/ucs/UCS_CVDs/ucs_vspex_vview500.pdf
Citrix XD 5.6 and XA 6.5 on vSphere 5.1 5/13 http://www.cisco.com/en/US/docs/unified_computing/ucs/UCS_CVDs/citrix_emc_ucs_XDXAscale.pdf
FlexPod w/ vSphere 5.1 5/13 http://www.cisco.com/en/US/docs/unified_computing/ucs/UCS_CVDs/esxi51_ucsm2_Clusterdeploy.html
SAP Applications on FlexPod w/ vSphere 5.1 5/13 http://www.cisco.com/en/US/docs/unified_computing/ucs/UCS_CVDs/ucs_flexpod_sap.html
VSPEX: V250 w/ vSphere 5.1 6/13 http://www.cisco.com/en/US/docs/unified_computing/ucs/UCS_CVDs/ucs_vspex_250vm.html
VSPEX: V100 and V125 w/ vSphere 5.1 6/13 http://www.cisco.com/en/US/docs/unified_computing/ucs/UCS_CVDs/ciscosol_vspex_v100v125.html
VSPEX: V50 vSphere 5.1 7/13 http://www.cisco.com/en/US/docs/unified_computing/ucs/UCS_CVDs/ucs_vspex_v50.html
FlexPod on Nexus 7k w/ vSphere 5.1 7/13 http://www.cisco.com/en/US/docs/unified_computing/ucs/UCS_CVDs/esxi51_N7k_fcoe_design.html
Visit Cisco Booth D209Twitter: @ciscoDC, #vmworld
Facebook: http://www.facebook.com/CiscoDC
Youtube: http://www.youtubecisco.com/datacenter
Cisco DCC Blog: http://blogs.cisco.com/datacenter
Slideshare: http://slideshare.com/CiscoDataCenter
Community: : https://communities.cisco.com/community/technology/datacenter
Pinterest: http://pinterest.com/ciscosystems/data-center
LinkedIn: http://www.linkedin.com search “Cisco Data Center” group
Google +: http://goo.gl/irm4b
In Collaboration with Intel®
Intel, the Intel logo, Xeon and Xeon inside are trademarks of Intel Corporation in the U.S. and other countries.
20© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential© 2010 Cisco and/or its affiliates. All rights reserved. Cisco Confidential 20