TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase...

40
1 HVAC EQUIPMENT IWDC-2 June 2001 TYPICAL WIRING DIAGRAM MANUAL INDOOR GAS-FIRED UNIT HEATERS AND DUCT FURNACES Standard (Natural Vent) or Power Vented Standing or Intermittent (Auto spark) Pilot Ignition Table of Contents ITEM PAGE General Safety Information ............................................................................................................. 2 Wiring Diagram Usage Charts Standard Propeller (Model QVF) .............................................................................................. 3, 4 Standard Blower (Model QVB) .................................................................................................. 5,6 Enerpak Propeller (Model QVEF) ................................................................................................. 7 Enerpak Blower (Model QVEB) .................................................................................................... 8 Standard Duct Furnaces (Models QVD and QVS) .................................................................. 9,10 Enerpak Duct Furnaces (Models QVED and QVES) .................................................................. 11 Wiring Diagrams Standard Propeller (Model QVF) ........................................................................................... 12-16 Standard Blower (Model QVB) .............................................................................................. 17-21 Enerpak Blower and Propeller (Models QVEB and QVEF) ................................................... 22-24 Standard Duct Furnaces (Models QVD and QVS) ................................................................ 25-34 Enerpak Duct Furnaces (Models QVED and QVES) ............................................................. 35-40 HVAC EQUIPMENT 260 NORTH ELM ST., WESTFIELD, MA 01085 TEL: (413) 564-5540 FAX: (413) 562-5311 Please use this toll free number to contact your local representative: 800-490-2290

Transcript of TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase...

Page 1: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

1

HVAC EQUIPMENT

IWDC-2June 2001

TYPICALWIRING DIAGRAM

MANUALINDOOR GAS-FIREDUNIT HEATERS ANDDUCT FURNACES

Standard (Natural Vent) or Power VentedStanding or Intermittent (Auto spark) Pilot Ignition

Table of Contents

ITEM PAGEGeneral Safety Information ............................................................................................................. 2Wiring Diagram Usage Charts

Standard Propeller (Model QVF) .............................................................................................. 3, 4Standard Blower (Model QVB) .................................................................................................. 5,6Enerpak Propeller (Model QVEF) ................................................................................................. 7Enerpak Blower (Model QVEB) .................................................................................................... 8Standard Duct Furnaces (Models QVD and QVS) .................................................................. 9,10Enerpak Duct Furnaces (Models QVED and QVES) .................................................................. 11

Wiring DiagramsStandard Propeller (Model QVF) ........................................................................................... 12-16Standard Blower (Model QVB) .............................................................................................. 17-21Enerpak Blower and Propeller (Models QVEB and QVEF) ................................................... 22-24Standard Duct Furnaces (Models QVD and QVS) ................................................................ 25-34Enerpak Duct Furnaces (Models QVED and QVES) ............................................................. 35-40

HVAC EQUIPMENT260 NORTH ELM ST., WESTFIELD, MA 01085

TEL: (413) 564-5540 • FAX: (413) 562-5311

Please use this toll free number to contactyour local representative: 800-490-2290

Page 2: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

2

GENERAL SAFETY INFORMATION

ELECTRICAL CONNECTIONSStandard units are shipped for use on 115 volt, 60 hertzsingle phase electric power. The motor nameplate andelectrical rating on the transformer should be checkedbefore energizing the unit heater electrical system. Allexternal wiring must conform to ANSI/NFPA No. 70-1996, National Electrical Code (or the latest edition of)and applicable local codes; in Canada, to the CanadianElectrical Code, Part 1 CSA Standard C22.1.

Do not use any tools (i.e.screwdriver, pliers, etc.) across the terminals tocheck for power. Use a voltmeter.

It is recommended that the electrical power supply toeach unit heater be provided by a separate, fused andpermanently live electric circuit. A disconnect switch ofsuitable electrical rating for each unit heater/ductfurnace should be located as close to the gas valve andcontrols as possible. Each unit heater /duct furnacemust be electrically grounded in accordance withNational Electric Code, ANSI/NFPA no. 70-1996 (or thelatest edition of) or CSA Standard C22.1. Sample wiringconnections are depicted throughout this manual. Thetransformer supplied with this unit heater is internallyfused. Any overload or short circuit will ruin thetransformer.

NOTICE: All installations and electricalconnections must conform to the InstallationInstructions Manual equipped with your unit.

NOTICE: For all electrical connections to yourunit, refer to the wiring diagram that your unit isequipped with (either affixed to the side jacketor enclosed in your unit’s installationinstruction envelope). This manual is forreference only.

THERMOSTAT WIRING AND LOCATION

NOTICE: The thermostat must be mounted on avertical vibration-free surface free from aircurrents and in accordance with the furnishedinstructions.

*Thermostat wires tagged “W” and “G” must beconnected together except when using a generalpurpose “SPDT” 24VAC relay and a standardthermostat with subbase, or when using HoneywellT834H-1009 or T834H-1017 thermostats. Refer to thefollowing diagram.

HAZARDOUS VOLTAGE!DISCONNECT ALL ELECTRICPOWER INCLUDING REMOTEDISCONNECTS BEFORESERVICING. Failure todisconnect power beforeservicing can cause severepersonal injury or death.

FACTORY WIRE CHANGES!CONSULT MANUFACTURER PRIOR TOCHANGING FACTORY WIRING. Incorrect wiringof safety circuits could result in death or fire.

USE COPPER CONDUCTORSONLY! UNIT TERMINALS ARE NOT DESIGNEDTO ACCEPT OTHER TYPES OF CONDUCTORS.Failure to do so may cause damage to the equip-ment.

CONTROL BOX COVER!CONTROL BOX COVER MUST BE IN PLACEWHEN SYSTEM IS OPERATED. Failure to replacecontrol box cover may result in personal injury.

IMPORTANT: Refer to installation and operationmanual for service instructions. Serviceequipment by qualified personnel only.

Install a ground conductor to the ground plugprovided if this unit is supplied by a wiringsystem that in accordance with the NationalElectric Code, requires the installation of anequipment grounding conductor or conductors.

Wiring must be in accordance with applicablecodes or ordinances.

Page 3: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

3

UNIT WIRING DIAGRAM USAGESModel “QVF” – Standard Propeller (Standing Pilot Ignition)

WIRINGDIAGRAM

NO.UNITTYPE

GASTYPE

UNITSIZE

GASCONTROL

STAGE

Natural Gas

LP Gas

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

OPTIONS INCLUDEDON THESE WIRINGDIAGRAMSManual Fan SwitchTerminal Blocks1-Stage Thermostat1-Stage T834H Thermostat2-Stage 24V Thermostat

OPTIONS NOT INCLUDEDON THESE WIRINGDIAGRAMSDraftor MotorLine-Voltage Stat’sThermostats

w/Subbase WiredMotor ContactorMotor Starter3-Phase Supply VoltageAll Others Specials

C1313PSee Figure 1

C1370 ECOSee Figure 2

C1313P ECOSee Figure 1

C1370 ECOSee Figure 2

C1313PSee Figure 1

C1370 ECOSee Figure 2

C1313P ECOSee Figure 1

C1370 ECOSee Figure 2

��

��

30-25030-250

300-400300-400

30-35030-350

400400

��

QVFPropellerStanding

Pilot �

Page 4: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

4

30-35030-350

400400

30-25030-250

300-400300-400

UNIT WIRING DIAGRAM USAGESModel “QVF” – Standard Propeller (Intermittent Spark Ignition)

WIRINGDIAGRAM

NO.UNITTYPE

GASTYPE

UNITSIZE

GASCONTROL

STAGE

Natural Gas

LP Gas

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

OPTIONS INCLUDEDON THESE WIRINGDIAGRAMSManual Fan SwitchTerminal Blocks1-Stage 24V Thermostat1-Stage T834H Thermostat2-Stage 24V Thermostat100% Shutoff Ignition

Lockout

OPTIONS NOT INCLUDEDON THESE WIRINGDIAGRAMSDraftor MotorLine-Voltage Stat’sThermostats

w/Subbase WiredAll Others Specials

C1316HSee Figure 4

C1339See Figure 5

C1316HSee Figure 4

C1339See Figure 5

C1316HSee Figure 4

C1339See Figure 5

C1316HSee Figure 4

C1339See Figure 5

��

��

��

QVFPropeller

SparkIgnition �

Page 5: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

5

UNIT WIRING DIAGRAM USAGESModel “QVB” – Standard Blower (Standing Pilot Ignition)

WIRINGDIAGRAM

NO.UNITTYPE

GASTYPE

UNITSIZE

GASCONTROL

STAGE

Natural Gas

LP Gas

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

OPTIONS INCLUDEDON THESE WIRINGDIAGRAMSManual Fan SwitchTerminal Blocks1-Stage 24V Ductstat1-Stage 24V Thermostat1-Stage T834H Thermostat

OPTIONS NOT INCLUDEDON THESE WIRINGDIAGRAMSDraftor MotorLine-Voltage Stat’sThermostats

w/Subbase WiredMotor ContactorMotor Starter3-Phase Supply VoltageAll Others Specials

C1311BSee Figure 6

C1340 ECOSee Figure 7

C1311B ECOSee Figure 6

C1340 ECOSee Figure 7

C1311BSee Figure 6

C1340 ECOSee Figure 7

C1311B ECOSee Figure 6

C1340 ECOSee Figure 7

��

��

��

100-250100-250

300-400300-400

100-350100-350

400400

QVBBlower

StandingPilot �

Page 6: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

6

Natural Gas

LP Gas

UNIT WIRING DIAGRAM USAGESModel “QVB” – Standard Blower (Intermittent Spark Ignition)

WIRINGDIAGRAM

NO.UNITTYPE

GASTYPE

UNITSIZE

GASCONTROL

STAGE

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

C1306BHSee Figure 8

C1321See Figure 10

C1306BHSee Figure 8

C1321See Figure 10

C1306BHSee Figure 8

C1321See Figure 10

��

��

100-350100-350

400400

100-400100-400

OPTIONS INCLUDEDON THESE WIRINGDIAGRAMSManual Fan SwitchTerminal Blocks1-Stage 24V Ductstat1-Stage 24V Thermostat1-Stage T834H Thermostat2-Stage 24V Ductstat2-Stage 24V Thermostat100% Shutoff Ignition

Lockout

OPTIONS NOT INCLUDEDON THESE WIRINGDIAGRAMSDraftor MotorLine-Voltage Stat’sThermostats

w/Subbase WiredMotor ContactorMotor Starter3-Phase Supply VoltageAll Others Specials

QVBBlowerSpark

Ignition �

Page 7: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

7

UNIT WIRING DIAGRAM USAGESModel “QVEF” – Power Vented “Enerpak” Propeller (Intermittent Spark Ignition)

WIRINGDIAGRAM

NO.UNITTYPE

GASTYPE

UNITSIZE

GASCONTROL

STAGE

Natural Gas

LP Gas

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

C1336HSee Figure 11

C1371See Figure 13

C1336HSee Figure 11

C1371See Figure 13

C1336HSee Figure 11

C1371See Figure 13

��

��

QVEFEnerpakPropeller

30-35030-350

400400

30-40030-400

OPTIONS INCLUDEDON THESE WIRINGDIAGRAMSManual Fan SwitchTerminal Blocks1-Stage 24V Thermostat1-Stage T834H Thermostat2-Stage 24V Thermostat100% Shutoff Ignition

Lockout

OPTIONS NOT INCLUDEDON THESE WIRINGDIAGRAMSLine-Voltage Stat’sThermostats

w/Subbase WiredAll Others Specials

Page 8: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

8

UNIT WIRING DIAGRAM USAGESModel “QVEB” – Power Vented “Enerpak” Blower (Intermittent Spark Ignition)

WIRINGDIAGRAM

NO.UNITTYPE

GASTYPE

UNITSIZE

GASCONTROL

STAGE

Natural Gas

LP Gas

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

OPTIONS INCLUDEDON THESE WIRINGDIAGRAMSManual Fan SwitchTerminal Blocks1-Stage 24V Ductstat1-Stage 24V Thermostat1-Stage T834H Thermostat2-Stage 24V Ductstat2-Stage 24V Thermostat100% Shutoff Ignition

Lockout

OPTIONS NOT INCLUDEDON THESE WIRINGDIAGRAMSLine-Voltage Stat’sThermostats

w/Subbase WiredMotor ContactorMotor Starter3-Phase Supply VoltageAll Others Specials

C1336HSee Figure 11

C1371See Figure 13

C1336HSee Figure 11

C1371See Figure 13

C1336HSee Figure 11

C1371See Figure 13

C1336WSee Figure 12

C1371See Figure 13

��

��

��

100-350100-350

400400

100-300100-300

350-400350-400

QVEBEnerpakBlower �

Page 9: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

9

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

UNIT WIRING DIAGRAM USAGESModels “QVD” & “QVS” – Standard Indoor Duct Furnaces (Standing Pilot Ignition)

WIRINGDIAGRAM

NO.

NOTEContact factory for3-phase wiringdiagrams.

OPTIONSINCLUDED ONUNITS WITHFAN TIME DELAYSManual Fan SwitchTerminal Blocks1-Stage 24V

Ductstat1-Stage 24V

Thermostat1-Stage T834H

Thermostat

OPTIONSINCLUDED ONUNITS WITHOUTFAN TIME DELAYSTerminal Blocks1 or 2 Stage 24V

Ductstat1 or 2 Stage 24V

Thermostat

OPTIONSNOT INCLUDEDDraftor MotorLine-Voltage Stat’sThermostats

w/Subbase WiredMotor ContactorMotor Starter3-Phase

Supply VoltageAll Others Specials

C1325See Figure 14

C1332See Figure 15

C1363 REDNSee Figure 16

C1327 REDNSee Figure 17

C1325 REDNSee Figure 14

C1332 REDNSee Figure 15

C1363 REDNSee Figure 16

C1327 REDNSee Figure 17

C1325See Figure 14

C1332See Figure 15

C1363 REDNSee Figure 16

C1327 REDNSee Figure 17

C1325 REDNSee Figure 14

C1332 REDNSee Figure 15

C1363 REDNSee Figure 16

C1327 REDNSee Figure 17

��

100-250100-200

300-400225-400

100-350100-200

400225-400

UNITTYPE

GASTYPE

UNITSIZE

GASCONTROL

STAGE

FANTIME

DELAYS

��

��

��

��

��

��

��

��

QVD/QVSStanding

PilotIndoor DuctFurnaces

F.T.D. = Fan Time Delay

��

��

��

Natural Gas

LP Gas

Page 10: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

10

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

UNIT WIRING DIAGRAM USAGESModels “QVD” & “QVS” – Standard Indoor Duct Furnace (Intermittent Spark Ignition)

WIRINGDIAGRAM

NO.

NOTEContact factory for3-phase wiringdiagrams.

OPTIONSINCLUDED ONUNITS WITHFAN TIME DELAYSManual Fan SwitchTerminal Blocks1or 2 Stage 24V

Ductstat1 or 2 Stage 24V

Thermostat1-Stage T834H

Thermostat100% Shutoff

Ignition Lockout

OPTIONSINCLUDED ONUNITS WITHOUTFAN TIME DELAYSTerminal Blocks1 or 2 Stage 24V

Ductstat1 or 2 Stage 24V

Thermostat100% Shutoff

Ignition Lockout

OPTIONSNOT INCLUDEDDraftor MotorLine-Voltage Stat’sThermostats

w/Subbase WiredMotor ContactorMotor Starter3-Phase

Supply VoltageAll Others Specials

C1331HSee Figure 18

C1337HSee Figure 19

C1369See Figure 20

C1338See Figure 21

C1331HSee Figure 18

C1337HSee Figure 19

C1369See Figure 20

C1338See Figure 21

C1331HSee Figure 18

C1337HSee Figure 19

C1369See Figure 20

C1338See Figure 21

��

100-350100-350

400400

100-400100-400

Natural Gas

LP Gas

UNITTYPE

GASTYPE

UNITSIZE

GASCONTROL

STAGE

FANTIME

DELAYS

��

��

��

��

��

��

�QVD/QVS

SparkIgnition

Indoor DuctFurnaces

F.T.D. = Fan Time Delay

��

Page 11: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

11

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

F.T.D.

No F.T.D.

1-Stage

2-Stage

1-Stage

2-Stage

1-Stage

2-Stage

UNIT WIRING DIAGRAM USAGESModels “QVED” & “QVES” – Powered Vented “Enerpak” Duct Furnaces (Intermittent Spark Ignition)

WIRINGDIAGRAM

NO.

OPTIONSINCLUDED ONUNITS WITHFAN TIME DELAYSManual Fan SwitchTerminal Blocks1-Stage 24V

Ductstat1-Stage 24V

Thermostat1-Stage T834H

Thermostat2-Stage 24V

Ductstat2-Stage 24V

Thermostat100% Shutoff

Ignition Lockout

OPTIONSINCLUDED ONUNITS WITHOUTFAN TIME DELAYSTerminal Blocks1-Stage 24V

Ductstat1-Stage 24V

Thermostat2-Stage 24V

Ductstat2-Stage 24V

Thermostat100% Shutoff

Ignition Lockout

OPTIONSNOT INCLUDEDLine-Voltage Stat’sThermostats

w/Subbase WiredMotor ContactorMotor Starter3-Phase

Supply VoltageAll Others Specials

C1335HSee Figure 24

C1334HSee Figure 25

C1343See Figure 26

C1342See Figure 27

C1335HSee Figure 24

C1334HSee Figure 25

C1343See Figure 26

C1342See Figure 27

C1335HSee Figure 24

C1334HSee Figure 25

C1343See Figure 26

C1342See Figure 27

��

100-350100-350

400400

100-400100-400

UNITTYPE

GASTYPE

UNITSIZE

GASCONTROL

STAGE

FANTIME

DELAYS

��

��

��

��

Natural Gas

LP Gas

��

��

QVED/QVESEnerpak

Indoor DuctFurnaces

F.T.D. = Fan Time Delay

��

Page 12: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

12

Fig

ure

1:

Pro

pel

ler

Un

it H

eate

r, S

tan

din

g P

ilot

Ign

itio

n, S

ing

le S

tag

e o

r H

ydra

ulic

Mo

du

lati

ng

Gas

Co

ntr

ol,

115/

1/60

,N

atu

ral o

r L

P (

Pro

pan

e) G

as, p

lus

Op

tio

ns.

Page 13: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

13

Fig

ure

2:

Pro

pel

ler

Un

it H

eate

r, S

tan

din

g P

ilot

Ign

itio

n, T

wo

Sta

ge

Gas

Co

ntr

ol,

115/

1/60

, Nat

ura

l or

LP

(P

rop

ane)

Gas

, plu

s O

pti

on

s.

Page 14: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

14

Fig

ure

3:

Pro

pel

ler

Un

it H

eate

r, In

term

itte

nt

Pilo

t (S

par

k) Ig

nit

ion

, Sin

gle

Sta

ge

or

Hyd

rau

lic M

od

ula

tin

g G

as C

on

tro

l, 11

5/1/

60,

Nat

ura

l Gas

, plu

s O

pti

on

s.

Page 15: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

15

Fig

ure

4:

Pro

pel

ler

Un

it H

eate

r, In

term

itte

nt

Pilo

t (S

par

k) Ig

nit

ion

, Sin

gle

Sta

ge

or

Hyd

rau

lic M

od

ula

tin

g G

as C

on

tro

l, 11

5/1/

60,

Nat

ura

l or

LP

(P

rop

ane)

Gas

, plu

s O

pti

on

s.

Page 16: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

16

Fig

ure

5:

Pro

pel

ler

Un

it H

eate

r, In

term

itte

nt

Pilo

t (S

par

k) Ig

nit

ion

, Tw

o S

tag

e G

as C

on

tro

l, 11

5/1/

60, N

atu

ral o

r L

P (

Pro

pan

e) G

as, p

lus

Op

tio

ns.

Page 17: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

17

Fig

ure

6:

Blo

wer

Un

it H

eate

r, S

tan

din

g P

ilot

Ign

itio

n, S

ing

le S

tag

e o

r H

ydra

ulic

Mo

du

lati

ng

Gas

Co

ntr

ol,

115-

230/

1/60

,N

atu

ral o

r L

P (

Pro

pan

e) G

as, p

lus

Op

tio

ns.

NO

TE

: 3-

ph

ase

un

its

– co

nta

ct f

acto

ry.

Page 18: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

18

Fig

ure

7:

Blo

wer

Un

it H

eate

r, S

tan

din

g P

ilot

Ign

itio

n, T

wo

Sta

ge

Gas

Co

ntr

ol,

115-

230/

1/60

, Nat

ura

l or

LP

(P

rop

ane)

Gas

, plu

s O

pti

on

s.N

OT

E:

3-p

has

e u

nit

s –

con

tact

fac

tory

.

Page 19: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

19

Fig

ure

8:

Blo

wer

Un

it H

eate

r, In

term

itte

nt

Pilo

t (S

par

k) Ig

nit

ion

, Sin

gle

Sta

ge

or

Hyd

rau

lic M

od

ula

tin

g G

as C

on

tro

l, 11

5-23

0/1/

60,

Nat

ura

l Gas

or

LP

(P

rop

ane)

Gas

, plu

s O

pti

on

s.

Page 20: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

20

Fig

ure

9:

Blo

wer

Un

it H

eate

r, In

term

itte

nt

Pilo

t (S

par

k) Ig

nit

ion

, Sin

gle

Sta

ge

or

Hyd

rau

lic M

od

ula

tin

g G

as C

on

tro

l, 11

5-23

0/1/

60,

Nat

ura

l Gas

, plu

s O

pti

on

s.

Page 21: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

21

Fig

ure

10:

Blo

wer

Un

it H

eate

r, In

term

itte

nt P

ilot (

Sp

ark)

Ign

itio

n, T

wo

Sta

ge

Gas

Co

ntr

ol,

115-

230/

1/60

, Nat

ura

l or

LP

(Pro

pan

e) G

as, p

lus

Op

tio

ns.

Page 22: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

22

Fig

ure

11:

“En

erp

ak”

Blo

wer

or

Pro

pel

ler

Un

it H

eate

rs, I

nte

rmit

ten

t P

ilot

(Sp

ark)

Ign

itio

n, S

ing

le S

tag

e o

r H

ydra

ulic

Mo

du

lati

ng

Gas

Co

ntr

ol,

115/

1/60

, Nat

ura

l Gas

or

LP

(P

rop

ane)

Gas

, Fac

tory

Inst

alle

d P

ow

er V

ente

r w

ith

Pre

ssu

re S

wit

ch, F

an T

ime

Del

ay, p

lus

Op

tio

ns.

Page 23: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

23

Fig

ure

12:

“En

erp

ak”

Blo

wer

or

Pro

pel

ler

Un

it H

eate

rs, I

nte

rmit

ten

t P

ilot

(Sp

ark)

Ign

itio

n, S

ing

le S

tag

e o

r H

ydra

ulic

Mo

du

lati

ng

Gas

Co

ntr

ol,

115/

1/60

, Nat

ura

l Gas

, Fac

tory

Inst

alle

d P

ow

er V

ente

r w

ith

Pre

ssu

re S

wit

ch, F

an T

ime

Del

ay, p

lus

Op

tio

ns.

Page 24: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

24

Fig

ure

13:

“En

erp

ak”

Blo

wer

or

Pro

pel

ler

Un

it H

eate

rs, I

nte

rmit

ten

t P

ilot

(Sp

ark)

Ign

itio

n, T

wo

Sta

ge

Gas

Co

ntr

ol,

115/

1/60

,N

atu

ral o

r L

P (

Pro

pan

e) G

as, F

acto

ry In

stal

led

Po

wer

Ven

ter

wit

h P

ress

ure

Sw

itch

, Fan

Tim

e D

elay

, plu

s O

pti

on

s.

Page 25: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

25

Fig

ure

14:

Ind

oo

r D

uct

Fu

rnac

e, S

tan

din

g P

ilot

Ign

itio

n, S

ing

le S

tag

e o

r H

ydra

ulic

Mo

du

lati

ng

Gas

Co

ntr

ol,

115-

230/

1/60

,N

atu

ral o

r L

P (

Pro

pan

e) G

as, F

an T

ime

Del

ay, p

lus

Op

tio

ns.

Page 26: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

26

Fig

ure

15:

Ind

oo

r D

uct

Fu

rnac

e, S

tan

din

g P

ilot

Ign

itio

n, S

ing

le S

tag

e o

r H

ydra

ulic

Mo

du

lati

ng

Gas

Co

ntr

ol,

115-

230/

1/60

,N

atu

ral o

r L

P (

Pro

pan

e) G

as, p

lus

Op

tio

ns.

Page 27: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

27

Fig

ure

16:

Ind

oo

r D

uct

Fu

rnac

e, S

tan

din

g P

ilot

Ign

itio

n, T

wo

Sta

ge

Gas

Co

ntr

ol,

115-

230/

1/60

, Nat

ura

l or

LP

(P

rop

ane)

Gas

, Fan

Tim

e D

elay

,p

lus

Op

tio

ns.

Page 28: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

28

Fig

ure

17:

Ind

oo

r D

uct

Fu

rnac

e, S

tan

din

g P

ilot

Ign

itio

n, T

wo

Sta

ge

Gas

Co

ntr

ol,

115-

230/

1/60

, Nat

ura

l or

LP

(P

rop

ane)

Gas

, plu

s O

pti

on

s.

Page 29: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

29

Fig

ure

18:

Ind

oo

r D

uct

Fu

rnac

e, In

term

itte

nt

Pilo

t (S

par

k) Ig

nit

ion

, Sin

gle

Sta

ge

or

Hyd

rau

lic M

od

ula

tin

g G

as C

on

tro

l, 11

5-23

0/1/

60,

Nat

ura

l Gas

or

LP

(P

rop

ane)

Gas

, Fan

Tim

e D

elay

, plu

s O

pti

on

s.

Page 30: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

30

Fig

ure

19:

Ind

oo

r D

uct

Fu

rnac

e, In

term

itte

nt

Pilo

t (S

par

k) Ig

nit

ion

, Sin

gle

Sta

ge

or

Hyd

rau

lic M

od

ula

tin

g G

as C

on

tro

l, 11

5-23

0/1/

60,

Nat

ura

l Gas

or

LP

(P

rop

ane)

Gas

, plu

s O

pti

on

s.

Page 31: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

31

Fig

ure

20:

Ind

oo

r D

uct

Fu

rnac

e, In

term

itte

nt

Pilo

t (S

par

k) Ig

nit

ion

, Tw

o S

tag

e G

as C

on

tro

l, 11

5-23

0/1/

60, N

atu

ral o

r L

P (

Pro

pan

e) G

as,

Fan

Tim

e D

elay

, plu

s O

pti

on

s.

Page 32: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

32

Fig

ure

21:

Ind

oo

r D

uct

Fu

rnac

e, In

term

itte

nt

Pilo

t (S

par

k) Ig

nit

ion

, Tw

o S

tag

e G

as C

on

tro

l, 11

5-23

0/1/

60, N

atu

ral o

r L

P (

Pro

pan

e) G

as,

plu

s O

pti

on

s.

Page 33: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

33

Fig

ure

22:

Ind

oo

r D

uct

Fu

rnac

e, In

term

itte

nt

Pilo

t (S

par

k) Ig

nit

ion

, Sin

gle

Sta

ge

or

Hyd

rau

lic M

od

ula

tin

g G

as C

on

tro

l, 11

5-23

0/1/

60,

Nat

ura

l Gas

, Fan

Tim

e D

elay

, plu

s O

pti

on

s.

Page 34: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

34

Fig

ure

23:

Ind

oo

r D

uct

Fu

rnac

e, In

term

itte

nt

Pilo

t (S

par

k) Ig

nit

ion

, Sin

gle

Sta

ge

or

Hyd

rau

lic M

od

ula

tin

g G

as C

on

tro

l, 11

5-23

0/1/

60,

Nat

ura

l Gas

, plu

s O

pti

on

s.

Page 35: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

35

Fig

ure

24:

“En

erp

ak”

Du

ct F

urn

ace,

Inte

rmit

ten

t P

ilot

(Sp

ark)

Ign

itio

n, S

ing

le S

tag

e o

r H

ydra

ulic

Mo

du

lati

ng

Gas

Co

ntr

ol,

115/

1/60

,N

atu

ral G

as o

r L

P (

Pro

pan

e) G

as, F

acto

ry In

stal

led

Po

wer

Ven

ter

wit

h P

ress

ure

Sw

itch

, Fan

Tim

e D

elay

, plu

s O

pti

on

s.

Page 36: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

36

Fig

ure

25:

“En

erp

ak”

Du

ct F

urn

ace,

Inte

rmit

ten

t P

ilot

(Sp

ark)

Ign

itio

n, S

ing

le S

tag

e o

r H

ydra

ulic

Mo

du

lati

ng

Gas

Co

ntr

ol,

115/

1/60

,N

atu

ral G

as o

r L

P (

Pro

pan

e) G

as, F

acto

ry in

stal

led

Po

wer

Ven

ter

wit

h P

ress

ure

Sw

itch

, plu

s O

pti

on

s.

Page 37: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

37

Fig

ure

26:

“En

erp

ak”

Du

ct F

urn

ace,

Inte

rmit

ten

t P

ilot

(Sp

ark)

Ign

itio

n, T

wo

Sta

ge

Gas

Co

ntr

ol,

115/

1/60

, Nat

ura

l or

LP

(P

rop

ane)

Gas

,F

acto

ry In

stal

led

Po

wer

Ven

ter

wit

h P

ress

ure

Sw

itch

, plu

s O

pti

on

s.

Page 38: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

38

Fig

ure

27:

“En

erp

ak”

Du

ct F

urn

ace,

Inte

rmit

ten

t P

ilot

(Sp

ark)

Ign

itio

n, T

wo

Sta

ge

Gas

Co

ntr

ol,

115/

1/60

, Nat

ura

l or

LP

(P

rop

ane)

Gas

,F

acto

ry In

stal

led

Po

wer

Ven

ter

wit

h P

ress

ure

Sw

itch

, plu

s O

pti

on

s.

Page 39: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

39

Fig

ure

28:

“En

erp

ak”

Du

ct F

urn

ace,

Inte

rmit

ten

t P

ilot

(Sp

ark)

Ign

itio

n, S

ing

le S

tag

e o

r H

ydra

ulic

Mo

du

lati

ng

Gas

Co

ntr

ol,

115/

1/60

,N

atu

ral G

as, F

acto

ry In

stal

led

Po

wer

Ven

ter

wit

h P

ress

ure

Sw

itch

, Fan

Tim

e D

elay

, plu

s O

pti

on

s.

Page 40: TYPICAL WIRING DIAGRAM MANUAL - H-Mac WIRING DIAGRAM MANUAL INDOOR GAS-FIRED ... single phase electric power. The motor nameplate and electrical rating on the transformer should be

40

Fig

ure

29:

“En

erp

ak”

Du

ct F

urn

ace,

Inte

rmit

ten

t P

ilot

Ign

itio

n, S

ing

le S

tag

e o

r H

ydra

ulic

Mo

du

lati

ng

Gas

Co

ntr

ol,

115/

1/60

,N

atu

ral G

as, F

acto

ry In

stal

led

Po

wer

Ven

ter

wit

h P

ress

ure

Sw

itch

, plu

s O

pti

on

s.