GSPublisherEngine 0.2.100.100 GENERAL NOTES : 1. Do not scale Drawings. If drawings are in question or discrepancy, the builder shall be responsible for obtaining clarification from the building designer and or building surveyor before continuing with construction. 2. All dimensions relating to existing conditions shall be field verified. 3. Where otherwise specified all products shall be installed according to Radial Timbers specifications. This applies not withstanding any relevant Building Act, Regulation, Building Code of Australia, Local Government Regulation/Requirement and Australian Standard. 4. Radial Timbers recommends the following gap spacing for V/Join Shiplap: · 45mm & 70mm - 3mm Gap spacing · 90mm & 110mm - 5mm Gap spacing 5. All external timbers to be treated against weather exposure to current AS 1604 specifications or no less than durability Class 1 In-Ground/Class 2 Above Ground as per AS 5604 Timber Natural Durability Ratings. 6. All external steel & fixings to be a minimum of Hot Dip Galvanized or equivalent corrosion protection to AS 2311 & 2312 unless within 1Km from a salt water environment then Marine grade Stainless steel is to be used, except where noted otherwise by the NCC. 7. All Residential timber framing, bracing & tie downs are to be in accordance to AS 1684 (Commercial construction specifications to be provided by Engineer). 8. Compliance with the relevant National Construction Code Of Australia (NCC) Volume 1 & or Volume 2 is mandatory (Not limited to) & the GUIDE TO STANDARDS & TOLERANCES. 9. Compliance with the (NCC) Volume 1: 3.5.3.2 Timber Cladding & 3.5.3.6 Flashings to wall openings Openings in external wall cladding exposed to the weather must be flashed as follows: (a) All openings must be adequately flashed using materials that comply with AS/NZS 2904. (b) Flashings must be securely fixed at least 25 mm under the cladding 10. Compliance with the following Australian Standards is mandatory (Not limited to): AS 1684 TIMBER FRAMED CONSTRUCTION AS 5604 NATURAL TIMBER DURABILITY AS 3959 CONSTRUCTION IN BUSHFIRE AREAS AS 2796.1 TIMBER HARDWOOD - SAWN & MILLED PRODUCTS (PRODUCT SPECIFICATION) AS 2047 WINDOWS IN BUILDINGS AS 2870 RESIDENTIAL SLABS & FOOTINGS AS 1250 THE USE OF STEEL IN STRUCTURES AS 4100 STEEL STRUCTURES AS 2311 PAINTING OF BUILDINGS AS 3600 TERMITE MANAGEMENT AS 1170 STRUCTURAL DESIGN ACTIONS AS 1428 DESIGN FOR ACCESS AND MOBILITY AS 1675 FIXED PLATFORMS, WALKWAYS, STAIRWAYS AND LADDERS - DESIGN, CONSTRUCTION AND INSTALLATION 11. All underground services (Sewer, Drainage, Gas, Electric, telecommunications, etc;) to be determined on site & from relevant authority records, prior to commencement of any construction. A2 - Not To Scale RADIAL TIMBER SALES 12 PARK DRIVE, DANDENONG SOUTH 3175 PH: (03) 9768 2100 FAX: (03) 9768 2177 EMAIL: [email protected] WEB: www.radialtimbers.com.au DRAWING NAME: THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS AND NOTIFY ALL ERRORS AND OMISSIONS TO THE DESIGNER. DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTIL ISSUED BY THE DESIGNER FOR CONSTRUCTION. DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY. FIXING DETAILS: REFER TO RADIAL TIMBERS RECOMMENDED FIXINGS (www.radialtimbers.com.au) NOTES: DATE: SCALE: REVISION: DWG NO: REVISION: DWG NO: Typical Radial Board & Batten Details BB01 04 18-Feb-17 75mm Nominal 100mm Nominal 125mm Nominal 25 25 25 50mm Nominal 23 35mm Nominal 65mm Nominal 80mm Nominal 105mm Nominal Typical Rough Sawn Unseasoned Bevelled Edge (BE) Section Profile Nominal Nominal Nominal 75x25mm BE 100x25mm BE 125x25mm BE 50x25mm BE Nominal 80 50 80 55 100 55 100 50 100 75 100 75 80 75 80 55 125 55 25 25 25 25 25 25 25 25 25 25 25 25 Stainless steel screw as appropriate or Hot Dipped Galvanized ring shank nail as appropriate (See Radial Timber fixing recommendations). Stainless steel screw as appropriate or Hot Dipped Galvanized ring shank nail as appropriate (See Radial Timber fixing recommendations). Stainless steel screw as appropriate or Hot Dipped Galvanized ring shank nail as appropriate (See Radial Timber fixing recommendations). Under lapped board Over lapped board Under lapped board Over lapped board Under lapped board Over lapped board Internal side Internal side Internal side Typical Radial BE Board & Batten combinations: 75mm (Face board) x 100mm (Backing board) Typical Radial BE Board & Batten combinations: 100mm (Face board) x 100mm (Backing board) Typical Radial BE Board & Batten combinations: 75mm (Face board) x 125mm (Backing board) Note: Radial recommends a minimum of 25-30mm overlap of face boards (See Radial Timber fixing recommendation sheet) All Bevelled Edge rough sawn timbers are nominal size. External Face External Face External Face NOTE: Termite Treatment in accordance with AS3600 required. Installer to comply with AS3959 - Construction In Bushfire areas. IMPORTANT: Refer to Radial Timber Product specifications for further fixing information: www.radialtimbers.com.au Typical Radial Bevelled Edge Board & Batten unseasoned rough sawn wall cladding with window/window flashing example inset

Transcript of Typical Radial Bevelled Edge Board & Batten unseasoned ......that comply with AS/NZS 2904. (b)...

  • GSPublisherEngine 0.2.100.100

    GENERAL NOTES:

    1. Do not scale Drawings. If drawings are in question ordiscrepancy, the builder shall be responsible for obtainingclarification from the building designer and or buildingsurveyor before continuing with construction.

    2. All dimensions relating to existing conditions shall be fieldverified.

    3. Where otherwise specified all products shall be installedaccording to Radial Timbers specifications. This applies notwithstanding any relevant Building Act, Regulation, BuildingCode of Australia, Local GovernmentRegulation/Requirement and Australian Standard.

    4. Radial Timbers recommends the following gap spacing forV/Join Shiplap:· 45mm & 70mm - 3mm Gap spacing· 90mm & 110mm - 5mm Gap spacing

    5. All external timbers to be treated against weather exposureto current AS 1604 specifications or no less than durabilityClass 1 In-Ground/Class 2 Above Ground as per AS 5604Timber Natural Durability Ratings.

    6. All external steel & fixings to be a minimum of Hot DipGalvanized or equivalent corrosion protection to AS 2311 &2312 unless within 1Km from a salt water environment thenMarine grade Stainless steel is to be used, except wherenoted otherwise by the NCC.

    7. All Residential timber framing, bracing & tie downs are to bein accordance to AS 1684 (Commercial constructionspecifications to be provided by Engineer).

    8. Compliance with the relevant National Construction CodeOf Australia (NCC) Volume 1 & or Volume 2 is mandatory(Not limited to) & theGUIDE TO STANDARDS & TOLERANCES.

    9. Compliance with the (NCC) Volume 1:3.5.3.2 Timber Cladding & 3.5.3.6 Flashingsto wall openingsOpenings in external wall cladding exposed to the weathermust be flashed as follows:

    (a) All openings must be adequately flashed using materialsthat comply with AS/NZS 2904.

    (b) Flashings must be securely fixed at least 25 mm under thecladding

    10. Compliance with the following Australian Standards ismandatory (Not limited to):

    AS 1684 TIMBER FRAMED CONSTRUCTIONAS 5604 NATURAL TIMBER DURABILITYAS 3959 CONSTRUCTION IN BUSHFIRE AREASAS 2796.1 TIMBER HARDWOOD -SAWN & MILLED PRODUCTS(PRODUCT SPECIFICATION)AS 2047 WINDOWS IN BUILDINGS AS 2870 RESIDENTIAL SLABS & FOOTINGSAS 1250 THE USE OF STEEL IN STRUCTURESAS 4100 STEEL STRUCTURESAS 2311 PAINTING OF BUILDINGS AS 3600 TERMITE MANAGEMENTAS 1170 STRUCTURAL DESIGN ACTIONSAS 1428 DESIGN FOR ACCESS AND MOBILITYAS 1675 FIXED PLATFORMS, WALKWAYS, STAIRWAYSAND LADDERS - DESIGN, CONSTRUCTION ANDINSTALLATION

    11. All underground services (Sewer, Drainage, Gas, Electric,telecommunications, etc;) to be determined on site & fromrelevant authority records, prior to commencement of anyconstruction.

    A2 - Not To Scale

    RADIAL TIMBER SALES12 PARK DRIVE,DANDENONG SOUTH 3175PH: (03) 9768 2100FAX: (03) 9768 2177EMAIL: [email protected]: www.radialtimbers.com.au

    DRAWING NAME:THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS ANDNOTIFY ALL ERRORS AND OMISSIONS TO THE DESIGNER.DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTILISSUED BY THE DESIGNER FOR CONSTRUCTION.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.FIXING DETAILS:REFER TO RADIAL TIMBERS RECOMMENDED FIXINGS(www.radialtimbers.com.au)

    NOTES:

    DATE:

    SCALE:

    REVISION:

    DWG NO:

    REVISION:

    DWG NO:

    Typical Radial Board & Batten Details

    BB01

    0418-Feb-17

    75mm Nominal

    100mm Nominal

    125mm Nominal

    2525

    25

    50mm Nominal

    23

    35mm Nominal

    65mm Nominal

    80mm Nominal

    105mm Nominal

    Typical Rough SawnUnseasoned Bevelled Edge (BE)

    Section Profile

    Nom

    inal

    Nom

    inal

    Nom

    inal

    75x25mm BE

    100x25mm BE

    125x25mm BE

    50x25mm BE

    Nom

    inal

    80 50 80

    55 100 55

    100 50 100

    75 100 75

    80 75 80

    55 125 55

    2525

    2525

    2525

    25 25

    25 25

    25 25

    Stainless steel screw as appropriate or Hot DippedGalvanized ring shank nail as appropriate(See Radial Timber fixing recommendations).

    Stainless steel screw as appropriate or Hot DippedGalvanized ring shank nail as appropriate(See Radial Timber fixing recommendations).

    Stainless steel screw as appropriate or Hot DippedGalvanized ring shank nail as appropriate(See Radial Timber fixing recommendations).

    Under lapped board

    Over lapped board

    Under lapped board

    Over lapped board

    Under lapped board

    Over lapped board

    Internal side

    Internal side

    Internal side

    Typical Radial BE Board & Batten combinations:75mm (Face board) x 100mm (Backing board)

    Typical Radial BE Board & Batten combinations:100mm (Face board) x 100mm (Backing board)

    Typical Radial BE Board & Batten combinations:75mm (Face board) x 125mm (Backing board)

    Note: Radial recommends a minimum of 25-30mm overlap of face boards(See Radial Timber fixing recommendation sheet)All Bevelled Edge rough sawn timbers are nominal size.

    External Face

    External Face

    External Face

    NOTE:Termite Treatment in accordance with AS3600 required.Installer to comply with AS3959 - Construction In Bushfire areas.

    IMPORTANT:Refer to Radial Timber Product specifications for further fixing information:www.radialtimbers.com.au

    Typical Radial Bevelled Edge Board & Batten unseasoned rough sawn wall cladding with window/window flashing example inset

  • GSPublisherEngine 0.2.100.100

    GENERAL NOTES:

    1. Do not scale Drawings. If drawings are in question ordiscrepancy, the builder shall be responsible for obtainingclarification from the building designer and or buildingsurveyor before continuing with construction.

    2. All dimensions relating to existing conditions shall be fieldverified.

    3. Where otherwise specified all products shall be installedaccording to Radial Timbers specifications. This applies notwithstanding any relevant Building Act, Regulation, BuildingCode of Australia, Local GovernmentRegulation/Requirement and Australian Standard.

    4. Radial Timbers recommends the following gap spacing forV/Join Shiplap:· 45mm & 70mm - 3mm Gap spacing· 90mm & 110mm - 5mm Gap spacing

    5. All external timbers to be treated against weather exposureto current AS 1604 specifications or no less than durabilityClass 1 In-Ground/Class 2 Above Ground as per AS 5604Timber Natural Durability Ratings.

    6. All external steel & fixings to be a minimum of Hot DipGalvanized or equivalent corrosion protection to AS 2311 &2312 unless within 1Km from a salt water environment thenMarine grade Stainless steel is to be used, except wherenoted otherwise by the NCC.

    7. All Residential timber framing, bracing & tie downs are to bein accordance to AS 1684 (Commercial constructionspecifications to be provided by Engineer).

    8. Compliance with the relevant National Construction CodeOf Australia (NCC) Volume 1 & or Volume 2 is mandatory(Not limited to) & theGUIDE TO STANDARDS & TOLERANCES.

    9. Compliance with the (NCC) Volume 1:3.5.3.2 Timber Cladding & 3.5.3.6 Flashingsto wall openingsOpenings in external wall cladding exposed to the weathermust be flashed as follows:

    (a) All openings must be adequately flashed using materialsthat comply with AS/NZS 2904.

    (b) Flashings must be securely fixed at least 25 mm under thecladding

    10. Compliance with the following Australian Standards ismandatory (Not limited to):

    AS 1684 TIMBER FRAMED CONSTRUCTIONAS 5604 NATURAL TIMBER DURABILITYAS 3959 CONSTRUCTION IN BUSHFIRE AREASAS 2796.1 TIMBER HARDWOOD -SAWN & MILLED PRODUCTS(PRODUCT SPECIFICATION)AS 2047 WINDOWS IN BUILDINGS AS 2870 RESIDENTIAL SLABS & FOOTINGSAS 1250 THE USE OF STEEL IN STRUCTURESAS 4100 STEEL STRUCTURESAS 2311 PAINTING OF BUILDINGS AS 3600 TERMITE MANAGEMENTAS 1170 STRUCTURAL DESIGN ACTIONSAS 1428 DESIGN FOR ACCESS AND MOBILITYAS 1675 FIXED PLATFORMS, WALKWAYS, STAIRWAYSAND LADDERS - DESIGN, CONSTRUCTION ANDINSTALLATION

    11. All underground services (Sewer, Drainage, Gas, Electric,telecommunications, etc;) to be determined on site & fromrelevant authority records, prior to commencement of anyconstruction.

    A2 - Not To Scale

    RADIAL TIMBER SALES12 PARK DRIVE,DANDENONG SOUTH 3175PH: (03) 9768 2100FAX: (03) 9768 2177EMAIL: [email protected]: www.radialtimbers.com.au

    DRAWING NAME:THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS ANDNOTIFY ALL ERRORS AND OMISSIONS TO THE DESIGNER.DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTILISSUED BY THE DESIGNER FOR CONSTRUCTION.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.FIXING DETAILS:REFER TO RADIAL TIMBERS RECOMMENDED FIXINGS(www.radialtimbers.com.au)

    NOTES:

    DATE:

    SCALE:

    REVISION:

    DWG NO:

    REVISION:

    DWG NO:

    Radial Board & Batten Wall (Noggin) Fixing Details

    BB02

    0418-Feb-17

    150

    Timber framing as perAS1684

    Stagger cutting joins over alternating noggins.End cuts to be mitred and flush joined. Cuts to besealed with relevant sealer product as appropriate

    Moisture Vapour barrier or relevantimpermeable wall underlay as perNCC and AS1684

    Vertical Bevelled Edge Board & Batten boardsfixed to noggins and top/bottom plate. Nogginsmax 600mm centres.

    Typical polyethelene film moisture barrier(See AS2870 for further details)

    Under lapped Board (See BB01)Over lapped board (See BB01)

    End cuts to be sealed with relevant oilbased sealer product as appropriate

    Noggins to comply with AS1684.2 (6.2.1.5).Vertical installation is recommended to havefixings at 450 - 600mm maximum.

    150mm Min distance as per(NCC: 3.1.2.3) and/or (AS2870: 5.2.2)

    BB02:A1

    BB02:A2

    Steel flashing as per (NCC:3.5.3.6)as appropriate

    Fixing as appropriate(See NCC Vol 1: 3.5.3.2 TimberCladding) and Radial Timber fixingrecommendations(www.radialtimbers.com.au)

    See Radial fixing recommendations forminimum overlap for Board & Batten.

    Typical timber bearer

    Termite cap as perNCC 3.1.3 Termite Management &AS3600 Termite Management

    Typical Timber Barge Boardsattached to cleat on side of stump

    Typical timber joist

    Typical Concreteor timber stump

    Typical timber frame stud

    Typical Particleboardsheeting

    Moisture vapourbarrier or releventimpermeable wall

    underlay as per NCC

    Under lapped board (See BB01)Over lapped board (See BB01)

    End cuts to be sealed with relevantoil based sealer product asappropriate.Bottom side of board to be undercutmin 150 angle to form drip edge onvertical fixed boards.Cladding to be min 50mm past FloorLevel

    Refer AS1684 Timber FramingManual for Span tables/sizes of

    timber subfloor bearers/joists

    Width

    Over

    all D

    epth

    Depth

    Foo

    ting

    Fill

    Min H

    eight

    Timber framing as perAS1684

    Moisture Vapour barrier or relevantimpermeable wall underlay as perNCC and AS1684

    Typical Particleboard sheetinglaid over timber floor Joists

    (See AS1860.2)

    Typical timber bearer

    Min sub floor height as perNCC 3.4.1 Sub Floor Ventillation.Height taken from bottom of bearer

    to Ground Level (GL)

    Typical timber floor joist

    Stump & Footing size refer to:AS1684 Timber Framing Manual &/or

    AS2870 Residential Slabs & Footings(or Engineers specifications where applicable)

    Termite cap on top of stump as perNCC 3.1.3 Termite Management &AS3600 Termite Management

    Typical Timber Barge Boardsattached to cleat on side of stump

    Typical concrete stump

    Stagger cutting joins over alternating noggins.End cuts to be mitred and flush joined. Cuts to besealed with relevant sealer product as appropriate

    Vertical Bevelled Edge Board & Batten boardsfixed to noggins and top/bottom plate. Nogginsmax 600mm centres.

    Under lapped Board (See BB01)Over lapped board (See BB01)

    End cuts to be sealed with relevant oilbased sealer product as appropriate

    Noggins to comply with AS1684.2 (6.2.1.5).Vertical installation is recommended to have fixings at450 - 600mm maximum.

    Refer AS1684 TimberFraming Manual for Span

    tables/sizes of timbersubfloor bearers/joists

    BB02-B1

    Vertical fixed BE Board & Batten tobe mitred over noggin and lappedas pictured.

    Moisturevapour barrier

    or releventimpermeablewall underlay

    as per NCC

    End cuts to be mitred and flush joined.Cuts to be sealed with relevant sealerproduct as appropriate.

    Screw/Nail fixing as per RadialTimber Supplies product fixinginformation specifications.Fix board 10mm min clear of joint.

    Under lapped board (See BB01)Over lapped board (See BB01)

    150m

    m

    50

    6Steel flashing as per (NCC:3.5.3.6) as appropriate

    Optional timber block under flashing attached to masonry wall withsuitable anchor. Timber to be minimum H3 or Class 2, or as appropriate.

    Screw/Nail fixing as per Radial Timber Suppliesproduct fixing information specifications.Fix board 10mm min clear of end.

    Clearance distance to finished Ground Level - 150mm Min distanceas per (NCC: 3.1.2.3) and/or (AS2870: 5.2.2)

    Bottom side of board to be undercut min 150 angle to form drip edgeon vertical fixed boards. Cladding to be min 50mm past Floor Level6mm mincapillary gap

    betweencladding &slab edge

    Under lapped board (See BB01)Over lapped board (See BB01)

    BB02:A - BE Board & Batten Noggin Fixing SOG1:151.0

    BB02:B1 - Vertical Board & Batten Bottom Flashing1:52.1

    BB02:B - BE Board & Batten Noggin Fixing Timber Sub-Floor1:152.0

    BB02:A1 - Vertical Board & Batten Mitre Join1:51.1

    BB02:A2 - Vertical Board & Batten Bottom Flashing1:51.2

    NOTE:Termite Treatment in accordance with AS3600 required.Installer to comply with AS3959 - Construction In Bushfire areas.

    NOTE:Radial Timber Product specifications noted here-in are manufacturers information for guidancepurposes only. Adherance with applicable Building Acts, Building Regulations,National Construction Codes, Local Government Regulations/Planning, Australian Standardsmust take precedence.

    IMPORTANT:Refer to Radial Timber Product specifications for further fixing information:www.radialtimbers.com.au

  • GSPublisherEngine 0.2.100.100

    GENERAL NOTES:

    1. Do not scale Drawings. If drawings are in question ordiscrepancy, the builder shall be responsible for obtainingclarification from the building designer and or buildingsurveyor before continuing with construction.

    2. All dimensions relating to existing conditions shall be fieldverified.

    3. Where otherwise specified all products shall be installedaccording to Radial Timbers specifications. This applies notwithstanding any relevant Building Act, Regulation, BuildingCode of Australia, Local GovernmentRegulation/Requirement and Australian Standard.

    4. Radial Timbers recommends the following gap spacing forV/Join Shiplap:· 45mm & 70mm - 3mm Gap spacing· 90mm & 110mm - 5mm Gap spacing

    5. All external timbers to be treated against weather exposureto current AS 1604 specifications or no less than durabilityClass 1 In-Ground/Class 2 Above Ground as per AS 5604Timber Natural Durability Ratings.

    6. All external steel & fixings to be a minimum of Hot DipGalvanized or equivalent corrosion protection to AS 2311 &2312 unless within 1Km from a salt water environment thenMarine grade Stainless steel is to be used, except wherenoted otherwise by the NCC.

    7. All Residential timber framing, bracing & tie downs are to bein accordance to AS 1684 (Commercial constructionspecifications to be provided by Engineer).

    8. Compliance with the relevant National Construction CodeOf Australia (NCC) Volume 1 & or Volume 2 is mandatory(Not limited to) & theGUIDE TO STANDARDS & TOLERANCES.

    9. Compliance with the (NCC) Volume 1:3.5.3.2 Timber Cladding & 3.5.3.6 Flashingsto wall openingsOpenings in external wall cladding exposed to the weathermust be flashed as follows:

    (a) All openings must be adequately flashed using materialsthat comply with AS/NZS 2904.

    (b) Flashings must be securely fixed at least 25 mm under thecladding

    10. Compliance with the following Australian Standards ismandatory (Not limited to):

    AS 1684 TIMBER FRAMED CONSTRUCTIONAS 5604 NATURAL TIMBER DURABILITYAS 3959 CONSTRUCTION IN BUSHFIRE AREASAS 2796.1 TIMBER HARDWOOD -SAWN & MILLED PRODUCTS(PRODUCT SPECIFICATION)AS 2047 WINDOWS IN BUILDINGS AS 2870 RESIDENTIAL SLABS & FOOTINGSAS 1250 THE USE OF STEEL IN STRUCTURESAS 4100 STEEL STRUCTURESAS 2311 PAINTING OF BUILDINGS AS 3600 TERMITE MANAGEMENTAS 1170 STRUCTURAL DESIGN ACTIONSAS 1428 DESIGN FOR ACCESS AND MOBILITYAS 1675 FIXED PLATFORMS, WALKWAYS, STAIRWAYSAND LADDERS - DESIGN, CONSTRUCTION ANDINSTALLATION

    11. All underground services (Sewer, Drainage, Gas, Electric,telecommunications, etc;) to be determined on site & fromrelevant authority records, prior to commencement of anyconstruction.

    A2 - Not To Scale

    RADIAL TIMBER SALES12 PARK DRIVE,DANDENONG SOUTH 3175PH: (03) 9768 2100FAX: (03) 9768 2177EMAIL: [email protected]: www.radialtimbers.com.au

    DRAWING NAME:THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS ANDNOTIFY ALL ERRORS AND OMISSIONS TO THE DESIGNER.DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTILISSUED BY THE DESIGNER FOR CONSTRUCTION.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.FIXING DETAILS:REFER TO RADIAL TIMBERS RECOMMENDED FIXINGS(www.radialtimbers.com.au)

    NOTES:

    DATE:

    SCALE:

    REVISION:

    DWG NO:

    REVISION:

    DWG NO:

    Radial Board & Batten Wall (Batten) Fixing Details

    BB03

    0418-Feb-17

    100

    Typical polyethelene filmmoisture barrier

    (See AS2870 for further details)

    Timber framing as perAS1684

    End cuts to be sealed with relevant oilbased sealer product as appropriate

    Timber or plastic shim spacer as appropriate (Min 10mm)

    Moisture Vapour barrier or relevantimpermeable wall underlay as perNCC and AS1684

    Noggins at 600mm centres max.Noggins to comply with AS1684.2 (6.2.1.5)

    Stagger cutting joins over alternating noggins.End cuts to be mitred and flush joined. Cuts to besealed with relevant sealer product as appropriate

    Vertical Bevelled Edge Board & Battenboards fixed to horizontal timber battens.

    Under lapped Board (See BB01)Over lapped board (See BB01)

    Timber Battens: Vertical installation is recommended to havefixings at 450 - 600mm maximum. Minimum H2 or Class 3.

    150mm Min distance as per(NCC: 3.1.2.3) and/or (AS2870: 5.2.2)

    BB03:A2

    BB03:A1

    50

    End cuts to be sealed withrelevant oil based sealer productas appropriate.Optional (Recommended):Bottom side of board to beundercut min 150 angle to formdrip edge on vertical fixed boards.Cladding to be min 50mm pastFloor Level

    Flashing as appropriate

    Under lapped board (See BB01)Over lapped board (See BB01)

    Width

    Over

    all D

    epth

    Depth

    Foo

    ting

    Fill

    Min H

    eight

    Timber framing as perAS1684

    Typical Particleboard sheetinglaid over timber floor Joists

    (See AS1860.2)

    Typical timber bearer

    Min sub floor height as perNCC 3.4.1 Sub Floor Ventillation.Height taken from bottom of bearer

    to Ground Level (GL)

    Typical timber floor joist

    Stump & Footing size refer to:AS1684 Timber Framing Manual &/or

    AS2870 Residential Slabs & Footings(or Engineers specifications where applicable)

    Termite cap on top of stump as perNCC 3.1.3 Termite Management &AS3600 Termite Management

    Typical Timber Barge Boardsattached to cleat on side of stump

    Typical concrete stump

    Vertical Bevelled Edge Board & Battenboards fixed to horizontal timber battens.

    End cuts to be sealed with relevant oilbased sealer product as appropriate

    Moisture Vapour barrier or relevantimpermeable wall underlay as perNCC and AS1684

    Stagger cutting joins over alternating noggins.End cuts to be mitred and flush joined. Cuts to besealed with relevant sealer product as appropriate

    Noggins at 600mm centres max.Noggins to comply with AS1684.2 (6.2.1.5)

    Under lapped Board (See BB01)Over lapped board (See BB01)

    Timber Battens: Vertical installation is recommended to havefixings at 450 - 600mm maximum. Minimum H2 or Class 3.

    Refer AS1684 TimberFraming Manual for Span

    tables/sizes of timbersubfloor bearers/joists

    BB03:B1

    BB03:B2

    Vertical fixed shiplap to be mitredover batten and lapped as pictured

    Moisture vapour barrier orrelevant impermeable wallunderlay as per NCC &AS1684

    Cuts to be mitred and flush joined.Cuts to be sealed with relevantsealer product as appropriate

    Timber batten, size asappropriate. Timber battensat 600mm centres max.Minimum H2 or Class 3Timber or plastic shimpacker over vertical stud,width as appropriate studsize (Min 10mm thickness)

    Screw/Nail fixing as per RadialTimber Supplies product fixinginformation specifications.Fix board 10mm min clear of joint.

    Under lapped board (See BB01)Over lapped board (See BB01)

    35

    35

    10

    75

    Typical timber packing shim 10mmthickness. Packing shim used forpacking horizontal fixing battens toalleviate and ventillate any moisturebuild up between moisture vapourbarrier and timber cladding.

    This can easily docked by customerfrom studs, etc;

    37

    75

    54

    12 13 12

    10

    Typical plastic horseshoe packingshim 10mm thickness. Packingshim used for packing horizontalfixing battens to alleviate andventillate any moisture build upbetween moisture vapour barrierand timber cladding

    50

    Steel flashing as per (NCC:3.5.3.6)as appropriate

    Fixing as appropriate(See NCC Vol 1: 3.5.3.2 Timber Cladding)and Radial Timber fixing recommendations(www.radialtimbers.com.au)

    Typical timber bearer

    Termite cap as perNCC 3.1.3 Termite Management &AS3600 Termite Management

    Typical Timber Barge Boards attached to cleat onside of stump

    Typical timber joist

    Typical Concreteor timber stump

    Typical timber frame stud

    Typical Particleboardsheeting

    Moisture vapourbarrier or releventimpermeable wallunderlay as per NCC

    End cuts to be sealed with relevant oil basedsealer product as appropriate.Bottom side of board to be undercut min150 angle to form drip edge on vertical fixedboards.Cladding to be min 50mm past Floor Level

    Timber or plastic shim spacer as appropriate(Min 10mm)

    Typical timber batten as appropriate

    Under lapped board (See BB01)Over lapped board (See BB01)

    Refer AS1684 Timber FramingManual for Span tables/sizes of

    timber subfloor bearers/joists

    BB03:A - BE Board & Batten Batten Fixing SOG1:151.0

    BB03:A2 - Vertical Board & Batten End Flashing1:51.2

    BB03:B - BE Board & Batten Batten Fixing Timber Sub-Floor1:152.0

    BB03:A1 & BB03:B1 - Vertical B&B Mitre Join1:51.1/2.1

    Typical Timber Packer1:54.0

    Typical Plastic Packer1:53.0

    BB03:B2 - Vertical Board & Batten End Flashing1:52.2

    NOTE:Termite Treatment in accordance with AS3600 required.Installer to comply with AS3959 - Construction In Bushfire areas.

    NOTE:Radial Timber Product specifications noted here-in are manufacturers information for guidancepurposes only. Adherance with applicable Building Acts, Building Regulations,National Construction Codes, Local Government Regulations/Planning, Australian Standardsmust take precedence.

    IMPORTANT:Refer to Radial Timber Product specifications for further fixing information:www.radialtimbers.com.au

  • GSPublisherEngine 0.2.100.100

    GENERAL NOTES:

    1. Do not scale Drawings. If drawings are in question ordiscrepancy, the builder shall be responsible for obtainingclarification from the building designer and or buildingsurveyor before continuing with construction.

    2. All dimensions relating to existing conditions shall be fieldverified.

    3. Where otherwise specified all products shall be installedaccording to Radial Timbers specifications. This applies notwithstanding any relevant Building Act, Regulation, BuildingCode of Australia, Local GovernmentRegulation/Requirement and Australian Standard.

    4. Radial Timbers recommends the following gap spacing forV/Join Shiplap:· 45mm & 70mm - 3mm Gap spacing· 90mm & 110mm - 5mm Gap spacing

    5. All external timbers to be treated against weather exposureto current AS 1604 specifications or no less than durabilityClass 1 In-Ground/Class 2 Above Ground as per AS 5604Timber Natural Durability Ratings.

    6. All external steel & fixings to be a minimum of Hot DipGalvanized or equivalent corrosion protection to AS 2311 &2312 unless within 1Km from a salt water environment thenMarine grade Stainless steel is to be used, except wherenoted otherwise by the NCC.

    7. All Residential timber framing, bracing & tie downs are to bein accordance to AS 1684 (Commercial constructionspecifications to be provided by Engineer).

    8. Compliance with the relevant National Construction CodeOf Australia (NCC) Volume 1 & or Volume 2 is mandatory(Not limited to) & theGUIDE TO STANDARDS & TOLERANCES.

    9. Compliance with the (NCC) Volume 1:3.5.3.2 Timber Cladding & 3.5.3.6 Flashingsto wall openingsOpenings in external wall cladding exposed to the weathermust be flashed as follows:

    (a) All openings must be adequately flashed using materialsthat comply with AS/NZS 2904.

    (b) Flashings must be securely fixed at least 25 mm under thecladding

    10. Compliance with the following Australian Standards ismandatory (Not limited to):

    AS 1684 TIMBER FRAMED CONSTRUCTIONAS 5604 NATURAL TIMBER DURABILITYAS 3959 CONSTRUCTION IN BUSHFIRE AREASAS 2796.1 TIMBER HARDWOOD -SAWN & MILLED PRODUCTS(PRODUCT SPECIFICATION)AS 2047 WINDOWS IN BUILDINGS AS 2870 RESIDENTIAL SLABS & FOOTINGSAS 1250 THE USE OF STEEL IN STRUCTURESAS 4100 STEEL STRUCTURESAS 2311 PAINTING OF BUILDINGS AS 3600 TERMITE MANAGEMENTAS 1170 STRUCTURAL DESIGN ACTIONSAS 1428 DESIGN FOR ACCESS AND MOBILITYAS 1675 FIXED PLATFORMS, WALKWAYS, STAIRWAYSAND LADDERS - DESIGN, CONSTRUCTION ANDINSTALLATION

    11. All underground services (Sewer, Drainage, Gas, Electric,telecommunications, etc;) to be determined on site & fromrelevant authority records, prior to commencement of anyconstruction.

    A2 - Not To Scale

    RADIAL TIMBER SALES12 PARK DRIVE,DANDENONG SOUTH 3175PH: (03) 9768 2100FAX: (03) 9768 2177EMAIL: [email protected]: www.radialtimbers.com.au

    DRAWING NAME:THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS ANDNOTIFY ALL ERRORS AND OMISSIONS TO THE DESIGNER.DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTILISSUED BY THE DESIGNER FOR CONSTRUCTION.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.FIXING DETAILS:REFER TO RADIAL TIMBERS RECOMMENDED FIXINGS(www.radialtimbers.com.au)

    NOTES:

    DATE:

    SCALE:

    REVISION:

    DWG NO:

    REVISION:

    DWG NO:

    Radial Board & Batten External Corner Details

    BB04

    0418-Feb-17

    50

    75

    Corner stud blocking as per timberframing standard AS1684

    Corner flashing as perNCC: 3.5.3.6 Flashings to

    wall openings

    Typical 75/100mm Board &Batten cladding

    Weather resistant flexible sealant betweencladding & corner stop as appropriateSquare cut cladding to suit corner stop as appropriate

    Moisture vapourbarrier or relevantimpermeable wallunderlay as per NCC& AS1684

    Typical Board & Batten100/100mm cladding

    Alternative 75x50mm (x1)SQE corner stop butt join

    Typical fixingto timber stud

    Typical timber stud.Spacing at 600mm centers max.

    Alternative 75x50mm (x1) SQETimber corner stop

    Typical Standard Board & Batten profile(Example 75mm & 100mm BE shown)

    Typical Standard Board & Batten profile(Example 100mm & 100mm BE shown)

    BB04:A2

    Typical timber stud.Spacing at 600mm centers max.

    Typical Standard Board & Batten profile(Example 75mm & 100mm BE shown)

    Typical Standard Board & Batten profile(Example 100mm & 100mm BE shown)

    Alternative 75x50mm (x2) SQETimber corner stop

    BB04:A1

    Typical 75/100mmBoard & Battencladding

    Typical Board & Batten100/100mm cladding Corner stud blocking as per timberframing standard AS1684

    Weather resistant flexible sealant betweencladding & corner stop as appropriate

    Moisture vapourbarrier or relevantimpermeable wallunderlay as per NCC& AS1684

    Corner flashing as perNCC: 3.5.3.6 Flashings to

    wall openings

    Square cut cladding to suit corner stop as appropriate

    Typical 75x50mm (x2)SQE corner stop butt join

    Typical 75/100mmBoard & Battencladding

    Typical Board & Batten100/100mm cladding Corner stud blocking as per timberframing standard AS1684

    Moisture vapourbarrier or relevantimpermeable wallunderlay as per NCC& AS1684

    Corner flashing as perNCC: 3.5.3.6 Flashings to

    wall openings

    Alternate option ofripping square edgeand butt join boards toexternal corner Typical 75/100mm

    Board & Battencladding

    Typical Board & Batten100/100mm cladding Corner stud blocking as per timberframing standard AS1684

    Weather resistant flexible sealant betweencladding & corner stop as appropriate

    Moisture vapourbarrier or relevantimpermeable wallunderlay as per NCC& AS1684

    Corner flashing as perNCC: 3.5.3.6 Flashings to

    wall openings

    Square cut cladding to suit corner stop as appropriateTypical 75x50mm (x2)

    SQE corner stop butt join

    Builder to cut rebate tocorner stop as required

    Alternate option of ripping bevellededge to match cladding

    BB04:B1 - Board & Batten Alternate External Corner Details1:52.1

    BB04:B - Alternate Board & Batten External Corner1:152.0

    BB04:A - Typical Board & Batten External Corner1:151.0

    BB04:A1 - Board & Batten External Corner Details1:51.1

    BB04:A2 - Board & Batten Alternate External Corner Details1:51.2

    BB04:B2 - Board & Batten Alternate External Corner Details1:52.2

    NOTE:Termite Treatment in accordance with AS3600 required.Installer to comply with AS3959 - Construction In Bushfire areas.

    NOTE:Radial Timber Product specifications noted here-in are manufacturers information for guidancepurposes only. Adherance with applicable Building Acts, Building Regulations,National Construction Codes, Local Government Regulations/Planning, Australian Standardsmust take precedence.

    IMPORTANT:Refer to Radial Timber Product specifications for further fixing information:www.radialtimbers.com.au

  • GSPublisherEngine 0.2.100.100

    GENERAL NOTES:

    1. Do not scale Drawings. If drawings are in question ordiscrepancy, the builder shall be responsible for obtainingclarification from the building designer and or buildingsurveyor before continuing with construction.

    2. All dimensions relating to existing conditions shall be fieldverified.

    3. Where otherwise specified all products shall be installedaccording to Radial Timbers specifications. This applies notwithstanding any relevant Building Act, Regulation, BuildingCode of Australia, Local GovernmentRegulation/Requirement and Australian Standard.

    4. Radial Timbers recommends the following gap spacing forV/Join Shiplap:· 45mm & 70mm - 3mm Gap spacing· 90mm & 110mm - 5mm Gap spacing

    5. All external timbers to be treated against weather exposureto current AS 1604 specifications or no less than durabilityClass 1 In-Ground/Class 2 Above Ground as per AS 5604Timber Natural Durability Ratings.

    6. All external steel & fixings to be a minimum of Hot DipGalvanized or equivalent corrosion protection to AS 2311 &2312 unless within 1Km from a salt water environment thenMarine grade Stainless steel is to be used, except wherenoted otherwise by the NCC.

    7. All Residential timber framing, bracing & tie downs are to bein accordance to AS 1684 (Commercial constructionspecifications to be provided by Engineer).

    8. Compliance with the relevant National Construction CodeOf Australia (NCC) Volume 1 & or Volume 2 is mandatory(Not limited to) & theGUIDE TO STANDARDS & TOLERANCES.

    9. Compliance with the (NCC) Volume 1:3.5.3.2 Timber Cladding & 3.5.3.6 Flashingsto wall openingsOpenings in external wall cladding exposed to the weathermust be flashed as follows:

    (a) All openings must be adequately flashed using materialsthat comply with AS/NZS 2904.

    (b) Flashings must be securely fixed at least 25 mm under thecladding

    10. Compliance with the following Australian Standards ismandatory (Not limited to):

    AS 1684 TIMBER FRAMED CONSTRUCTIONAS 5604 NATURAL TIMBER DURABILITYAS 3959 CONSTRUCTION IN BUSHFIRE AREASAS 2796.1 TIMBER HARDWOOD -SAWN & MILLED PRODUCTS(PRODUCT SPECIFICATION)AS 2047 WINDOWS IN BUILDINGS AS 2870 RESIDENTIAL SLABS & FOOTINGSAS 1250 THE USE OF STEEL IN STRUCTURESAS 4100 STEEL STRUCTURESAS 2311 PAINTING OF BUILDINGS AS 3600 TERMITE MANAGEMENTAS 1170 STRUCTURAL DESIGN ACTIONSAS 1428 DESIGN FOR ACCESS AND MOBILITYAS 1675 FIXED PLATFORMS, WALKWAYS, STAIRWAYSAND LADDERS - DESIGN, CONSTRUCTION ANDINSTALLATION

    11. All underground services (Sewer, Drainage, Gas, Electric,telecommunications, etc;) to be determined on site & fromrelevant authority records, prior to commencement of anyconstruction.

    A2 - Not To Scale

    RADIAL TIMBER SALES12 PARK DRIVE,DANDENONG SOUTH 3175PH: (03) 9768 2100FAX: (03) 9768 2177EMAIL: [email protected]: www.radialtimbers.com.au

    DRAWING NAME:THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS ANDNOTIFY ALL ERRORS AND OMISSIONS TO THE DESIGNER.DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTILISSUED BY THE DESIGNER FOR CONSTRUCTION.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.FIXING DETAILS:REFER TO RADIAL TIMBERS RECOMMENDED FIXINGS(www.radialtimbers.com.au)

    NOTES:

    DATE:

    SCALE:

    REVISION:

    DWG NO:

    REVISION:

    DWG NO:

    Board & Batten Window (Noggin Fixing) Flashing Details

    BB06

    0418-Feb-17

    15

    Flashing as per NCC 3.5.3.6: Flashings to Wall Openings and/orwindow manufacturers specifications.

    Flashing to have adequate fall for drainage as appropriate (Eg; 150)

    Timber Architrave

    Typical Impervious sealing strip(See specific window manufactuers specifications for further information)

    Moisture vapour barrier or relevantimpermeable wall underlay as per

    NCC & AS1684

    Moisture vapour barrier or relevantimpermeable wall underlay as per

    NCC & AS1684

    Timber Framing as per:AS1684.2 Timber Framed Construction (Part 6.2.3 Openings)

    Min 15mm clearance between Lintel and window head.

    Typical stud frame (See AS1684 Timber Framing Manual)

    Typical plasterboard sheet as required

    Timber reveal, size as appropriate

    Timber Architrave

    Typical Radial Board & BattenTypical stud frame (Checked out for timber window lintel as per AS 1684)

    Typical plasterboard sheet as required

    Timber reveal, size as appropriate

    Typical timber window lintel(See AS 1684 Timber Framing Manual for sizes/spans)

    Typical timber window ledger(See AS 1684 Timber Framing Manual for sizes/spans)

    Fixing reveal to lintel and ledger (size as appropriate).Min 15mm clearance between Lintel and window head.

    Over lapped board (See DT10)

    Under lapped board (See DT10)

    Flashing as per NCC 3.5.3.6: Flashings to Wall Openings and/orwindow manufacturers specifications.

    Flashing to have adequate fall for drainage as appropriate (Eg; 150)

    Over lapped board (See DT10)

    Under lapped board (See DT10)

    Typical Radial Board & Batten

    TypicalWindow

    Brackets & Fixings to support window structure as perwindow manufacturers or engineers specifica ons

    NOTE: Window details are indictation of cladding fixing only.For specific details it is recommended to refer to window manufacturers details

    WINDOWHEAD

    WINDOW SILL

    150

    150

    15

    Low modulus sealant

    Flashing as per NCC 3.5.3.6: Flashings to Wall Openings and/orwindow manufacturers specifications.

    Flashing to have adequate fall for drainage as appropriate (Eg; 150)

    Timber window head(See window manufacturers specifications)

    Timber Architrave

    Moisture vapour barrier or relevantimpermeable wall underlay as per

    NCC & AS1684

    Flashing as per NCC 3.5.3.6: Flashings to Wall Openings and/orwindow manufacturers specifications.

    Flashing to have adequate fall for drainage as appropriate (Eg; 150)

    Typical stud frame

    Typical plasterboard sheet as required

    Timber window sill(See window manufacturers specifications)

    Timber Architrave

    Moisture vapour barrier or relevantimpermeable wall underlay as per

    NCC & AS1684

    Typical stud frame (Checked out for timber window lintel as per AS 1684)

    Typical plasterboard sheet as required

    Typical timber window lintel(See AS 1684 Timber Framing Manual for sizes/spans)

    Typical timber window ledger(See AS 1684 Timber Framing Manual for sizes/spans)

    Over lapped board (See DT10)

    Under lapped board (See DT10)

    Typical Radial Board & Batten

    Timber Framing as per:AS1684.2 Timber Framed Construction (Part 6.2.3 Openings)

    Min 15mm clearance between Lintel and window head.

    Typical Radial Board & Batten

    Over lapped board (See DT10)

    Under lapped board (See DT10)

    TypicalWindow

    Brackets & Fixings to support window structure as perwindow manufacturers or engineers specifica ons

    NOTE: Window details are indictation of cladding fixing only.For specific details it is recommended to refer to window manufacturers details

    WINDOWHEAD

    WINDOW SILL

    150

    150

    75

    50

    Typical stud frame (As per AS 1684)

    Typical plasterboard sheet as required

    Timber Architrave

    Moisture vapour barrier or relevant impermeablewall underlay as per NCC & AS1684

    Fix window window frame to vertical timber stud.Packer as required between reveal and stud

    Flashing as per NCC: 3.5.3.6 Flashings to wall openings

    Typical Radial horizontalBevelled Edge Board & Batten

    Weather resistant flexible sealant betweencladding & corner stop as appropriate

    Typical 75x50mm SQE stopbutt join to Radcon Bevelled Edge

    Board & BattenUnder lapped board (See DT 10)

    Over lapped board (See DT 10)

    TypicalTimber

    Window

    Brackets & Fixings to support window structure as perwindow manufacturers or engineers specifica ons

    NOTE: Window details are indictation of cladding fixing only.For specific details it is recommended to refer to window manufacturers details

    75

    50

    Typical stud frame (As per AS 1684)

    Typical plasterboard sheet as required

    Timber Architrave

    Moisture vapour barrier or relevant impermeablewall underlay as per NCC & AS1684

    Fix window reveal to vertical timber stud.Packer as required between reveal and stud

    Flashing as per NCC: 3.5.3.6 Flashings to wall openings

    Typical 75x50mm SQE stopbutt join to Radcon Bevelled Edge

    Board & Batten

    Weather resistant flexible sealant betweencladding & corner stop as appropriate

    Under lapped board (See DT 10)

    Over lapped board (See DT 10)

    Typical Radial horizontalBevelled Edge Board & Batten

    TypicalAluminium

    Window

    Brackets & Fixings to support window structure as perwindow manufacturers or engineers specifica ons

    NOTE: Window details are indictation of cladding fixing only.For specific details it is recommended to refer to window manufacturers details

    BB06:A - Typical Board & Batten Aluminium Window Flashing Details Section (Noggin Fixing)1:51.0

    BB06:B - Typical Board & Batten Timber Window Flashing Details Section (Noggin Fixing)1:52.0

    BB06:B1 - Typical Board & Batten Timber Window Flashing Details Plan View1:52.1

    BB06:A1 - Typical Board & Batten Aluminium Window Flashing Details Plan View1:51.1

    NOTE:Termite Treatment in accordance with AS3600 required.Installer to comply with AS3959 - Construction In Bushfire areas.

    IMPORTANT:Refer to Radial Timber Product specifications for further fixinginformation: www.radialtimbers.com.au

    NCC Volume 2:3.5.3.6 Flashings to wall openingsOpenings in external wall cladding exposed to the weather must be flashed as follows:(a) All openings must be adequately flashed using materials that comply with AS/NZS 2904.(b) Flashings must be securely fixed at least 25 mm under the cladding and extend over theends and edges of the framing of the opening

    NOTE: Same principles for fixing (As per details here-in)apply for horizontal clad or vertical clad shiplap fixing

    TYPICAL TIMBER LINTEL OPTIONS FOR WINDOW OPENINGS (Below):AS 1684 (Timber Framing manual - Figure 6.8 Openings)

  • GSPublisherEngine 0.2.100.100

    GENERAL NOTES:

    1. Do not scale Drawings. If drawings are in question ordiscrepancy, the builder shall be responsible for obtainingclarification from the building designer and or buildingsurveyor before continuing with construction.

    2. All dimensions relating to existing conditions shall be fieldverified.

    3. Where otherwise specified all products shall be installedaccording to Radial Timbers specifications. This applies notwithstanding any relevant Building Act, Regulation, BuildingCode of Australia, Local GovernmentRegulation/Requirement and Australian Standard.

    4. Radial Timbers recommends the following gap spacing forV/Join Shiplap:· 45mm & 70mm - 3mm Gap spacing· 90mm & 110mm - 5mm Gap spacing

    5. All external timbers to be treated against weather exposureto current AS 1604 specifications or no less than durabilityClass 1 In-Ground/Class 2 Above Ground as per AS 5604Timber Natural Durability Ratings.

    6. All external steel & fixings to be a minimum of Hot DipGalvanized or equivalent corrosion protection to AS 2311 &2312 unless within 1Km from a salt water environment thenMarine grade Stainless steel is to be used, except wherenoted otherwise by the NCC.

    7. All Residential timber framing, bracing & tie downs are to bein accordance to AS 1684 (Commercial constructionspecifications to be provided by Engineer).

    8. Compliance with the relevant National Construction CodeOf Australia (NCC) Volume 1 & or Volume 2 is mandatory(Not limited to) & theGUIDE TO STANDARDS & TOLERANCES.

    9. Compliance with the (NCC) Volume 1:3.5.3.2 Timber Cladding & 3.5.3.6 Flashingsto wall openingsOpenings in external wall cladding exposed to the weathermust be flashed as follows:

    (a) All openings must be adequately flashed using materialsthat comply with AS/NZS 2904.

    (b) Flashings must be securely fixed at least 25 mm under thecladding

    10. Compliance with the following Australian Standards ismandatory (Not limited to):

    AS 1684 TIMBER FRAMED CONSTRUCTIONAS 5604 NATURAL TIMBER DURABILITYAS 3959 CONSTRUCTION IN BUSHFIRE AREASAS 2796.1 TIMBER HARDWOOD -SAWN & MILLED PRODUCTS(PRODUCT SPECIFICATION)AS 2047 WINDOWS IN BUILDINGS AS 2870 RESIDENTIAL SLABS & FOOTINGSAS 1250 THE USE OF STEEL IN STRUCTURESAS 4100 STEEL STRUCTURESAS 2311 PAINTING OF BUILDINGS AS 3600 TERMITE MANAGEMENTAS 1170 STRUCTURAL DESIGN ACTIONSAS 1428 DESIGN FOR ACCESS AND MOBILITYAS 1675 FIXED PLATFORMS, WALKWAYS, STAIRWAYSAND LADDERS - DESIGN, CONSTRUCTION ANDINSTALLATION

    11. All underground services (Sewer, Drainage, Gas, Electric,telecommunications, etc;) to be determined on site & fromrelevant authority records, prior to commencement of anyconstruction.

    A2 - Not To Scale

    RADIAL TIMBER SALES12 PARK DRIVE,DANDENONG SOUTH 3175PH: (03) 9768 2100FAX: (03) 9768 2177EMAIL: [email protected]: www.radialtimbers.com.au

    DRAWING NAME:THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS ANDNOTIFY ALL ERRORS AND OMISSIONS TO THE DESIGNER.DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTILISSUED BY THE DESIGNER FOR CONSTRUCTION.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.FIXING DETAILS:REFER TO RADIAL TIMBERS RECOMMENDED FIXINGS(www.radialtimbers.com.au)

    NOTES:

    DATE:

    SCALE:

    REVISION:

    DWG NO:

    REVISION:

    DWG NO:

    Board & Batten Window (Batten Fixing) Flashing Details

    BB07

    0418-Feb-17

    15

    Timber Architrave

    Typical Impervious sealing strip(See specific window manufactuers specifications for further information)

    Moisture vapour barrier or relevantimpermeable wall underlay as per

    NCC & AS1684

    Typical stud frame (See AS1684 Timber Framing Manual)

    Typical plasterboard sheet as required

    Timber reveal, size as appropriate

    Timber Architrave

    Typical plasterboard sheet as required

    Timber reveal, size as appropriate

    Typical timber window lintel(See AS 1684 Timber Framing Manual for sizes/spans)

    Typical timber window ledger(See AS 1684 Timber Framing Manual for sizes/spans)

    Fixing reveal to lintel and ledger (size as appropriate).Min 15mm clearance between Lintel and window head.

    Moisture vapour barrier or relevantimpermeable wall underlay as per

    NCC & AS1684

    Over lapped board (See DT10)

    Under lapped board (See DT10)

    Min 15mm clearance between Lintel and window head.

    Typical Radial Board & BattenTypical stud frame (Checked out for timber window lintel as per AS 1684).Timber Framing as per:AS1684.2 Timber Framed Construction (Part 6.2.3 Openings)

    Flashing as per NCC 3.5.3.6: Flashings to Wall Openings and/orwindow manufacturers specifications.

    Flashing to have adequate fall for drainage as appropriate (Eg; 150)

    Over lapped board (See DT10)

    Under lapped board (See DT10)

    Typical Radial Board & Batten

    Typical timber batten and packer: Timber or plastic shim spaceras appropriate (Min 10mm).Vertical installation is recommended to have fixings at 450 -600mm maximum. Minimum H2 or Class 3.

    Typical timber batten and packer: Timber or plastic shim spacer asappropriate (Min 10mm).Vertical installation is recommended to have fixings at 450 - 600mmmaximum. Minimum H2 or Class 3.

    TypicalWindow

    Brackets & Fixings to support window structure as perwindow manufacturers or engineers specifica ons

    NOTE: Window details are indictation of cladding fixing only.For specific details it is recommended to refer to window manufacturers details

    WINDOWHEAD

    WINDOW SILL

    150

    150

    15

    Timber Architrave

    Typical Impervious sealing strip(See specific window manufactuers specifications for further information)

    Moisture vapour barrier or relevantimpermeable wall underlay as per

    NCC & AS1684

    Typical stud frame (See AS1684 Timber Framing Manual)

    Typical plasterboard sheet as required

    Timber reveal, size as appropriate

    Timber Architrave

    Typical plasterboard sheet as required

    Timber reveal, size as appropriate

    Typical timber window lintel(See AS 1684 Timber Framing Manual for sizes/spans)

    Typical timber window ledger(See AS 1684 Timber Framing Manual for sizes/spans)

    Fixing reveal to lintel and ledger (size as appropriate).Min 15mm clearance between Lintel and window head.

    Moisture vapour barrier or relevantimpermeable wall underlay as per

    NCC & AS1684

    Over lapped board (See DT10)

    Under lapped board (See DT10)

    Min 15mm clearance between Lintel and window head.

    Typical Radial Board & BattenTypical stud frame (Checked out for timber window lintel as per AS 1684).Timber Framing as per:AS1684.2 Timber Framed Construction (Part 6.2.3 Openings)

    Flashing as per NCC 3.5.3.6: Flashings to Wall Openings and/orwindow manufacturers specifications.

    Flashing to have adequate fall for drainage as appropriate (Eg; 150)

    Over lapped board (See DT10)

    Under lapped board (See DT10)

    Typical Radial Board & Batten

    Typical timber batten and packer: Timber or plastic shim spaceras appropriate (Min 10mm).Vertical installation is recommended to have fixings at 450 -600mm maximum. Minimum H2 or Class 3.

    Typical timber batten and packer: Timber or plastic shim spacer asappropriate (Min 10mm).Vertical installation is recommended to have fixings at 450 - 600mmmaximum. Minimum H2 or Class 3.

    TypicalWindow

    Brackets & Fixings to support window structure as perwindow manufacturers or engineers specifica ons

    NOTE: Window details are indictation of cladding fixing only.For specific details it is recommended to refer to window manufacturers details

    WINDOWHEAD

    WINDOW SILL

    150

    150

    45

    75

    50

    Typical stud frame (As per AS 1684)

    Typical plasterboard sheet as required

    Timber Architrave

    Moisture vapour barrier or relevant impermeablewall underlay as per NCC & AS1684

    Fix window reveal to vertical timber stud.Packer as required between reveal and stud

    Typical timber batten and packer.Timber battens at 600mm centres max.Minimum H2 or Class 3

    Typical 45x19mm SQE stopbutt join to timber batten

    Flashing as per NCC: 3.5.3.6 Flashings to wall openings

    Typical 75x50mm SQE stopbutt join to Radcon Bevelled Edge

    Board & Batten

    Weather resistant flexible sealant betweencladding & corner stop as appropriate

    Under lapped board (See DT 10)Over lapped board (See DT 10)

    Typical Radial horizontalBevelled Edge Board & Batten

    Typical batten packer

    TypicalAluminium

    Window

    Brackets & Fixings to support window structure as perwindow manufacturers or engineers specifica ons

    NOTE: Window details are indictation of cladding fixing only.For specific details it is recommended to refer to window manufacturers details

    45

    75

    50

    Typical stud frame (As per AS 1684)

    Typical plasterboard sheet as required

    Timber Architrave

    Moisture vapour barrier or relevant impermeablewall underlay as per NCC & AS1684

    Fix window reveal to vertical timber stud.Packer as required between reveal and stud

    Typical timber batten and packer.Timber battens at 600mm centres max.Minimum H2 or Class 3

    Typical 45x19mm SQE stopbutt join to timber batten

    Flashing as per NCC: 3.5.3.6 Flashings to wall openings

    Typical 75x50mm SQE stopbutt join to Radcon Bevelled Edge

    Board & Batten

    Weather resistant flexible sealant betweencladding & corner stop as appropriate

    Under lapped board (See DT 10)Over lapped board (See DT 10)

    Typical Radial horizontalBevelled Edge Board & Batten

    Typical batten packer

    TypicalAluminium

    Window

    Brackets & Fixings to support window structure as perwindow manufacturers or engineers specifica ons

    NOTE: Window details are indictation of cladding fixing only.For specific details it is recommended to refer to window manufacturers details

    BB07:A - Typical Board & Batten Aluminium Window Flashing Details Section (Batten Fixing)1:51.0

    BB07:B - Typical Board & Batten Timber Window Flashing Details Section (Batten Fixing)1:52.0

    BB07:B1 - Typical Board & Batten Timber Window Flashing Details Section1:52.1

    BB07:A1 - Typical Board & Batten Aluminium Window Flashing Details Section1:51.1

    TYPICAL TIMBER LINTEL OPTIONS FOR WINDOW OPENINGS (Below):AS 1684 (Timber Framing manual - Figure 6.8 Openings)

    IMPORTANT:Refer to Radial Timber Product specifications for further fixinginformation: www.radialtimbers.com.au

    NCC Volume 2:3.5.3.6 Flashings to wall openingsOpenings in external wall cladding exposed to the weather must be flashed as follows:(a) All openings must be adequately flashed using materials that comply with AS/NZS 2904.(b) Flashings must be securely fixed at least 25 mm under the cladding and extend over theends and edges of the framing of the opening

    NOTE: Same principles for fixing (As per details here-in)apply for horizontal clad or vertical clad shiplap fixing

    NOTE:Termite Treatment in accordance with AS3600 required.Installer to comply with AS3959 - Construction In Bushfire areas.

  • GSPublisherEngine 0.2.100.100

    GENERAL NOTES:

    1. Do not scale Drawings. If drawings are in question ordiscrepancy, the builder shall be responsible for obtainingclarification from the building designer and or buildingsurveyor before continuing with construction.

    2. All dimensions relating to existing conditions shall be fieldverified.

    3. Where otherwise specified all products shall be installedaccording to Radial Timbers specifications. This applies notwithstanding any relevant Building Act, Regulation, BuildingCode of Australia, Local GovernmentRegulation/Requirement and Australian Standard.

    4. Radial Timbers recommends the following gap spacing forV/Join Shiplap:· 45mm & 70mm - 3mm Gap spacing· 90mm & 110mm - 5mm Gap spacing

    5. All external timbers to be treated against weather exposureto current AS 1604 specifications or no less than durabilityClass 1 In-Ground/Class 2 Above Ground as per AS 5604Timber Natural Durability Ratings.

    6. All external steel & fixings to be a minimum of Hot DipGalvanized or equivalent corrosion protection to AS 2311 &2312 unless within 1Km from a salt water environment thenMarine grade Stainless steel is to be used, except wherenoted otherwise by the NCC.

    7. All Residential timber framing, bracing & tie downs are to bein accordance to AS 1684 (Commercial constructionspecifications to be provided by Engineer).

    8. Compliance with the relevant National Construction CodeOf Australia (NCC) Volume 1 & or Volume 2 is mandatory(Not limited to) & theGUIDE TO STANDARDS & TOLERANCES.

    9. Compliance with the (NCC) Volume 1:3.5.3.2 Timber Cladding & 3.5.3.6 Flashingsto wall openingsOpenings in external wall cladding exposed to the weathermust be flashed as follows:

    (a) All openings must be adequately flashed using materialsthat comply with AS/NZS 2904.

    (b) Flashings must be securely fixed at least 25 mm under thecladding

    10. Compliance with the following Australian Standards ismandatory (Not limited to):

    AS 1684 TIMBER FRAMED CONSTRUCTIONAS 5604 NATURAL TIMBER DURABILITYAS 3959 CONSTRUCTION IN BUSHFIRE AREASAS 2796.1 TIMBER HARDWOOD -SAWN & MILLED PRODUCTS(PRODUCT SPECIFICATION)AS 2047 WINDOWS IN BUILDINGS AS 2870 RESIDENTIAL SLABS & FOOTINGSAS 1250 THE USE OF STEEL IN STRUCTURESAS 4100 STEEL STRUCTURESAS 2311 PAINTING OF BUILDINGS AS 3600 TERMITE MANAGEMENTAS 1170 STRUCTURAL DESIGN ACTIONSAS 1428 DESIGN FOR ACCESS AND MOBILITYAS 1675 FIXED PLATFORMS, WALKWAYS, STAIRWAYSAND LADDERS - DESIGN, CONSTRUCTION ANDINSTALLATION

    11. All underground services (Sewer, Drainage, Gas, Electric,telecommunications, etc;) to be determined on site & fromrelevant authority records, prior to commencement of anyconstruction.

    A2 - Not To Scale

    RADIAL TIMBER SALES12 PARK DRIVE,DANDENONG SOUTH 3175PH: (03) 9768 2100FAX: (03) 9768 2177EMAIL: [email protected]: www.radialtimbers.com.au

    DRAWING NAME:THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS ANDNOTIFY ALL ERRORS AND OMISSIONS TO THE DESIGNER.DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTILISSUED BY THE DESIGNER FOR CONSTRUCTION.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.FIXING DETAILS:REFER TO RADIAL TIMBERS RECOMMENDED FIXINGS(www.radialtimbers.com.au)

    NOTES:

    DATE:

    SCALE:

    REVISION:

    DWG NO:

    REVISION:

    DWG NO:

    Radial B&B Wall Overhang/Pitch Roof Details (Batten Fixing)

    BB08

    0418-Feb-17

    32

    D

    Moisture Vapour barrier or relevant impermeablewall underlay as per NCC and AS1684

    Timber moulding (Eg:Quad or other as appropriate)

    Eaves Lining Cement Sheet(Soffit) or as appropriate

    Typical Soffit bearer (70x35mm) - Fixed to side of rafter(Size as per AS1684:Timber Framing)

    Typical Fascia board

    Optional Soffit bearer hanger (See AS1684:Timber Framing)

    Typical Noggin (70x35mm) fixed between soffit bearers

    D/3 Max

    Typical Rafter

    Typical roofing batten

    Typical stud wall top plate

    Moisture Vapour barrier or relevant impermeablewall underlay as per NCC and AS1684

    Typical vertical wall stud (As per AS 1684)

    Typical particleboardflooring over floor joist

    Typical Soffit liningattached to battens

    Typical vertical wall stud (As per AS 1684)

    Flashing as per NCC 3.5.3.6: Flashings to Wall Openings and/orArchitects/Engineers specifications.Flashing to have adequate fall for drainage as appropriate (Eg; 150)

    Optional (Recommened):End cuts to be sealed with relevant oil based sealer product as appropriate.Bottom side of boards to be undercut min 150 angle to form drip edge onboards and 5-10mm clearance between flashing and boards to alleviate anymositure trapping issues

    Typical Radial Board & Batten

    Over lapped board(See DT10)

    Under lappedboard (See DT10)

    Optional supporting postby Architect/Engineer

    Typical Radial Board & Batten

    Over lapped board(See DT10)

    Under lappedboard (See DT10)

    Noggins to comply with AS1684.2 (6.2.1.5).Vertical installation is recommended to havefixings at 450 - 600mm maximum.

    Noggins to comply with AS1684.2 (6.2.1.5).Vertical installation is recommended to havefixings at 450 - 600mm maximum.

    D/3 = Not more than 1/3 to be cutfrom rafter for birdsmouth cut

    150

    Typical Floor Joist Beam as perArchitect/Engineer

    NOTE: Details are indictation of cladding fixing only.

    Vertical fixed shiplap to be mitredover batten and lapped as pictured

    Moisture vapour barrier orrelevant impermeable wallunderlay as per NCC &AS1684

    Cuts to be mitred and flush joined.Cuts to be sealed with relevantsealer product as appropriate

    Timber batten, size asappropriate. Timber battensat 600mm centres max.Minimum H2 or Class 3Timber or plastic shimpacker over vertical stud,width as appropriate studsize (Min 10mm thickness)

    Screw/Nail fixing as per RadialTimber Supplies product fixinginformation specifications.Fix board 10mm min clear of joint.

    Under lapped board (See BB01)Over lapped board (See BB01)

    35

    35

    10

    75

    Typical timber packing shim 10mmthickness. Packing shim used forpacking horizontal fixing battens toalleviate and ventillate any moisturebuild up between moisture vapourbarrier and timber cladding.

    This can easily docked by customerfrom studs, etc;37

    75

    54

    12 13 12

    10

    Typical plastic horseshoe packingshim 10mm thickness. Packingshim used for packing horizontalfixing battens to alleviate andventillate any moisture build upbetween moisture vapour barrierand timber cladding

    BB08:A - Typical Board & Batten Pitch Roof Detail Section (Batten Fixing)1:101.0

    BB03:A1 & BB03:B1 - Vertical B&B Mitre Join1:51.1

    Typical Timber Packer1:43.0

    Typical Plastic Packer1:42.0

    NOTE:Termite Treatment in accordance with AS3600 required.Installer to comply with AS3959 - Construction In Bushfire areas.

    NOTE:Radial Timber Product specifications noted here-in are manufacturers information for guidancepurposes only. Adherance with applicable Building Acts, Building Regulations,National Construction Codes, Local Government Regulations/Planning, Australian Standardsmust take precedence.

    IMPORTANT:Refer to Radial Timber Product specifications for further fixing information:www.radialtimbers.com.au

  • GSPublisherEngine 0.2.100.100

    GENERAL NOTES:

    1. Do not scale Drawings. If drawings are in question ordiscrepancy, the builder shall be responsible for obtainingclarification from the building designer and or buildingsurveyor before continuing with construction.

    2. All dimensions relating to existing conditions shall be fieldverified.

    3. Where otherwise specified all products shall be installedaccording to Radial Timbers specifications. This applies notwithstanding any relevant Building Act, Regulation, BuildingCode of Australia, Local GovernmentRegulation/Requirement and Australian Standard.

    4. Radial Timbers recommends the following gap spacing forV/Join Shiplap:· 45mm & 70mm - 3mm Gap spacing· 90mm & 110mm - 5mm Gap spacing

    5. All external timbers to be treated against weather exposureto current AS 1604 specifications or no less than durabilityClass 1 In-Ground/Class 2 Above Ground as per AS 5604Timber Natural Durability Ratings.

    6. All external steel & fixings to be a minimum of Hot DipGalvanized or equivalent corrosion protection to AS 2311 &2312 unless within 1Km from a salt water environment thenMarine grade Stainless steel is to be used, except wherenoted otherwise by the NCC.

    7. All Residential timber framing, bracing & tie downs are to bein accordance to AS 1684 (Commercial constructionspecifications to be provided by Engineer).

    8. Compliance with the relevant National Construction CodeOf Australia (NCC) Volume 1 & or Volume 2 is mandatory(Not limited to) & theGUIDE TO STANDARDS & TOLERANCES.

    9. Compliance with the (NCC) Volume 1:3.5.3.2 Timber Cladding & 3.5.3.6 Flashingsto wall openingsOpenings in external wall cladding exposed to the weathermust be flashed as follows:

    (a) All openings must be adequately flashed using materialsthat comply with AS/NZS 2904.

    (b) Flashings must be securely fixed at least 25 mm under thecladding

    10. Compliance with the following Australian Standards ismandatory (Not limited to):

    AS 1684 TIMBER FRAMED CONSTRUCTIONAS 5604 NATURAL TIMBER DURABILITYAS 3959 CONSTRUCTION IN BUSHFIRE AREASAS 2796.1 TIMBER HARDWOOD -SAWN & MILLED PRODUCTS(PRODUCT SPECIFICATION)AS 2047 WINDOWS IN BUILDINGS AS 2870 RESIDENTIAL SLABS & FOOTINGSAS 1250 THE USE OF STEEL IN STRUCTURESAS 4100 STEEL STRUCTURESAS 2311 PAINTING OF BUILDINGS AS 3600 TERMITE MANAGEMENTAS 1170 STRUCTURAL DESIGN ACTIONSAS 1428 DESIGN FOR ACCESS AND MOBILITYAS 1675 FIXED PLATFORMS, WALKWAYS, STAIRWAYSAND LADDERS - DESIGN, CONSTRUCTION ANDINSTALLATION

    11. All underground services (Sewer, Drainage, Gas, Electric,telecommunications, etc;) to be determined on site & fromrelevant authority records, prior to commencement of anyconstruction.

    A2 - Not To Scale

    RADIAL TIMBER SALES12 PARK DRIVE,DANDENONG SOUTH 3175PH: (03) 9768 2100FAX: (03) 9768 2177EMAIL: [email protected]: www.radialtimbers.com.au

    DRAWING NAME:THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS ANDNOTIFY ALL ERRORS AND OMISSIONS TO THE DESIGNER.DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTILISSUED BY THE DESIGNER FOR CONSTRUCTION.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.FIXING DETAILS:REFER TO RADIAL TIMBERS RECOMMENDED FIXINGS(www.radialtimbers.com.au)

    NOTES:

    DATE:

    SCALE:

    REVISION:

    DWG NO:

    REVISION:

    DWG NO:

    Radial B&B Wall Overhang/Pitch Roof Details (Noggin Fixing)

    BB09

    0418-Feb-17

    32

    D

    Moisture Vapour barrier or relevant impermeablewall underlay as per NCC and AS1684

    Timber moulding (Eg:Quad or other as appropriate)

    Eaves Lining Cement Sheet(Soffit) or as appropriate

    Typical Soffit bearer (70x35mm) - Fixed to side of rafter(Size as per AS1684:Timber Framing)

    Typical Fascia board

    Optional Soffit bearer hanger (See AS1684:Timber Framing)

    Typical Noggin (70x35mm) fixed between soffit bearers

    D/3 Max

    Typical Rafter

    Typical roofing batten

    Typical stud wall top plate

    Moisture Vapour barrier or relevant impermeablewall underlay as per NCC and AS1684

    Typical vertical wall stud (As per AS 1684)

    Typical particleboardflooring over floor joist

    Typical Soffit liningattached to battens

    Typical vertical wall stud (As per AS 1684)

    Flashing as per NCC 3.5.3.6: Flashings to Wall Openings and/orArchitects/Engineers specifications.Flashing to have adequate fall for drainage as appropriate (Eg; 150)

    Optional (Recommened):End cuts to be sealed with relevant oil based sealer product as appropriate.Bottom side of boards to be undercut min 150 angle to form drip edge onboards and 5-10mm clearance between flashing and boards to alleviate anymositure trapping issues

    Typical Radial Board & Batten

    Over lapped board(See DT10)

    Under lappedboard (See DT10)

    Optional supporting postby Architect/Engineer

    Typical Radial Board & Batten

    Over lapped board(See DT10)

    Under lappedboard (See DT10)

    Noggins to comply with AS1684.2 (6.2.1.5).Vertical installation is recommended to havefixings at 450 - 600mm maximum.

    Noggins to comply with AS1684.2 (6.2.1.5).Vertical installation is recommended to havefixings at 450 - 600mm maximum.

    D/3 = Not more than 1/3 to be cutfrom rafter for birdsmouth cut

    150

    Typical Floor Joist Beam as perArchitect/Engineer

    NOTE: Details are indictation of cladding fixing only.

    Vertical fixed BE Board & Batten tobe mitred over noggin and lappedas pictured.

    Moisturevapour barrier

    or releventimpermeablewall underlay

    as per NCC

    End cuts to be mitred and flush joined.Cuts to be sealed with relevant sealerproduct as appropriate.

    Screw/Nail fixing as per RadialTimber Supplies product fixinginformation specifications.Fix board 10mm min clear of joint.

    Under lapped board (See BB01)Over lapped board (See BB01)

    BB09:A - Typical Board & Batten Pitch Roof Detail Section (Noggin Fixing)1:101.0

    BB02:A1 - Vertical Board & Batten Mitre Join1:51.1

    NOTE:Termite Treatment in accordance with AS3600 required.Installer to comply with AS3959 - Construction In Bushfire areas.

    NOTE:Radial Timber Product specifications noted here-in are manufacturers information for guidancepurposes only. Adherance with applicable Building Acts, Building Regulations,National Construction Codes, Local Government Regulations/Planning, Australian Standardsmust take precedence.

    IMPORTANT:Refer to Radial Timber Product specifications for further fixing information:www.radialtimbers.com.au

  • GSPublisherEngine 0.2.100.100

    GENERAL NOTES:

    1. Do not scale Drawings. If drawings are in question ordiscrepancy, the builder shall be responsible for obtainingclarification from the building designer and or buildingsurveyor before continuing with construction.

    2. All dimensions relating to existing conditions shall be fieldverified.

    3. Where otherwise specified all products shall be installedaccording to Radial Timbers specifications. This applies notwithstanding any relevant Building Act, Regulation, BuildingCode of Australia, Local GovernmentRegulation/Requirement and Australian Standard.

    4. Radial Timbers recommends the following gap spacing forV/Join Shiplap:· 45mm & 70mm - 3mm Gap spacing· 90mm & 110mm - 5mm Gap spacing

    5. All external timbers to be treated against weather exposureto current AS 1604 specifications or no less than durabilityClass 1 In-Ground/Class 2 Above Ground as per AS 5604Timber Natural Durability Ratings.

    6. All external steel & fixings to be a minimum of Hot DipGalvanized or equivalent corrosion protection to AS 2311 &2312 unless within 1Km from a salt water environment thenMarine grade Stainless steel is to be used, except wherenoted otherwise by the NCC.

    7. All Residential timber framing, bracing & tie downs are to bein accordance to AS 1684 (Commercial constructionspecifications to be provided by Engineer).

    8. Compliance with the relevant National Construction CodeOf Australia (NCC) Volume 1 & or Volume 2 is mandatory(Not limited to) & theGUIDE TO STANDARDS & TOLERANCES.

    9. Compliance with the (NCC) Volume 1:3.5.3.2 Timber Cladding & 3.5.3.6 Flashingsto wall openingsOpenings in external wall cladding exposed to the weathermust be flashed as follows:

    (a) All openings must be adequately flashed using materialsthat comply with AS/NZS 2904.

    (b) Flashings must be securely fixed at least 25 mm under thecladding

    10. Compliance with the following Australian Standards ismandatory (Not limited to):

    AS 1684 TIMBER FRAMED CONSTRUCTIONAS 5604 NATURAL TIMBER DURABILITYAS 3959 CONSTRUCTION IN BUSHFIRE AREASAS 2796.1 TIMBER HARDWOOD -SAWN & MILLED PRODUCTS(PRODUCT SPECIFICATION)AS 2047 WINDOWS IN BUILDINGS AS 2870 RESIDENTIAL SLABS & FOOTINGSAS 1250 THE USE OF STEEL IN STRUCTURESAS 4100 STEEL STRUCTURESAS 2311 PAINTING OF BUILDINGS AS 3600 TERMITE MANAGEMENTAS 1170 STRUCTURAL DESIGN ACTIONSAS 1428 DESIGN FOR ACCESS AND MOBILITYAS 1675 FIXED PLATFORMS, WALKWAYS, STAIRWAYSAND LADDERS - DESIGN, CONSTRUCTION ANDINSTALLATION

    11. All underground services (Sewer, Drainage, Gas, Electric,telecommunications, etc;) to be determined on site & fromrelevant authority records, prior to commencement of anyconstruction.

    A2 - Not To Scale

    RADIAL TIMBER SALES12 PARK DRIVE,DANDENONG SOUTH 3175PH: (03) 9768 2100FAX: (03) 9768 2177EMAIL: [email protected]: www.radialtimbers.com.au

    DRAWING NAME:THE BUILDER SHALL CHECK AND VERIFY ALL DIMENSIONS ANDNOTIFY ALL ERRORS AND OMISSIONS TO THE DESIGNER.DRAWINGS ARE NOT TO BE USED FOR CONSTRUCTION UNTILISSUED BY THE DESIGNER FOR CONSTRUCTION.DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY.FIXING DETAILS:REFER TO RADIAL TIMBERS RECOMMENDED FIXINGS(www.radialtimbers.com.au)

    NOTES:

    DATE:

    SCALE:

    REVISION:

    DWG NO:

    REVISION:

    DWG NO:

    Radial Board & Batten Wall/Skillion Roof Flashing Details

    BB10

    0418-Feb-17

    Vertical fixed shiplap to be mitredover batten and lapped as pictured

    Moisture vapour barrier orrelevant impermeable wallunderlay as per NCC &AS1684

    Cuts to be mitred and flush joined.Cuts to be sealed with relevantsealer product as appropriate

    Timber batten, size asappropriate. Timber battensat 600mm centres max.Minimum H2 or Class 3Timber or plastic shimpacker over vertical stud,width as appropriate studsize (Min 10mm thickness)

    Screw/Nail fixing as per RadialTimber Supplies product fixinginformation specifications.Fix board 10mm min clear of joint.

    Under lapped board (See BB01)Over lapped board (See BB01)

    35

    35

    10

    75

    Typical timber packing shim 10mmthickness. Packing shim used forpacking horizontal fixing battens toalleviate and ventillate any moisturebuild up between moisture vapourbarrier and timber cladding.

    This can easily docked by customerfrom studs, etc;

    37

    75

    54

    12 13 12

    10

    Typical plastic horseshoe packingshim 10mm thickness. Packingshim used for packing horizontalfixing battens to alleviate andventillate any moisture build upbetween moisture vapour barrierand timber cladding

    Vertical fixed BE Board & Batten tobe mitred over noggin and lappedas pictured.

    Moisturevapour barrier

    or releventimpermeablewall underlay

    as per NCC

    End cuts to be mitred and flush joined.Cuts to be sealed with relevant sealerproduct as appropriate.

    Screw/Nail fixing as per RadialTimber Supplies product fixinginformation specifications.Fix board 10mm min clear of joint.

    Under lapped board (See BB01)Over lapped board (See BB01)

    75

    Moisture Vapour barrier or relevant impermeablewall underlay as per NCC and AS1684

    Noggins at 600mm centres max.Noggins to comply with AS1684.2 (6.2.1.5)

    Typical roof framingbatten (See AS1684) Typical sheet roofing

    Typical Rafter Typical stud wall top plate

    Typical vertical wall stud

    Typical flashing over roofcladding and rafter

    Typical Radial Board & Batten

    Over lapped board (See DT10)

    Under lapped board (See DT10)

    Typical roof framingbatten (See AS1684)

    Timber Battens: Vertical installation isrecommended to have fixings at 450 - 600mmmaximum. Minimum H2 or Class 3.

    75mm Minimum overlap of flashing

    Moisture Vapour barrier or relevant impermeablewall underlay as per NCC and AS1684

    Typical roof framingbatten (See AS1684) Typical sheet roofing

    Typical fascia board

    Typical Rafter Typical stud wall top plate

    Typical vertical wall stud

    Typical flashing over roofcladding and fascia board

    Typical Radial Board & Batten

    Over lapped board (See DT10)

    Under lapped board (See DT10)

    Noggins to comply with AS1684.2 (6.2.1.5).Vertical installation is recommended to havefixings at 450 - 600mm maximum.

    BB03:A1 & BB03:B1 - Vertical B&B Mitre Join1:42.1

    Typical Timber Packer1:44.0

    Typical Plastic Packer1:43.0

    BB02:A1 - Vertical Board & Batten Mitre Join1:41.1

    BB10:B - Typical Board & Batten Skillion Roof Detail Section (Batten Fixing)1:102.0

    BB10:A - Typical Board & Batten Skillion Roof Detail Section (Noggin Fixing)1:101.0

    NOTE:Termite Treatment in accordance with AS3600 required.Installer to comply with AS3959 - Construction In Bushfire areas.

    NOTE:Radial Timber Product specifications noted here-in are manufacturers information for guidancepurposes only. Adherance with applicable Building Acts, Building Regulations,National Construction Codes, Local Government Regulations/Planning, Australian Standardsmust take precedence.

    IMPORTANT:Refer to Radial Timber Product specifications for further fixing information:www.radialtimbers.com.au

    RTS Fixing Details - 1 - ViewsRTS DetailsBoard & BattenBB01 Typical Radial Board & Batten DetailsBB02 Radial Board & Batten Wall (Noggin) Fixing DetailsBB03 Radial Board & Batten Wall (Batten) Fixing DetailsBB04 Radial Board & Batten External Corner DetailsBB06 Board & Batten Window (Noggin Fixing) Flashing DetailsBB07 Board & Batten Window (Batten Fixing) Flashing DetailsBB08 Radial B&B Wall Overhang/Pitch Roof Details (Batten Fixing)BB09 Radial B&B Wall Overhang/Pitch Roof Details (Noggin Fixing)BB10 Radial Board & Batten Wall/Skillion Roof Flashing Details