1
4-3/4"(120mm) 8-11/16"(220mm) 5/16"(7.3mm) 2-3/8"(61mm) 7-15/16"(201.6mm) 4"(101.6mm) 3"(76.2mm) Two Gang Pop-up Floor Box Assembly with 20A Decorator Duplex Tamper & Weather Resistant Receptacle Model Number: 962301-C / 962301-S WIRING DIAGRAM Two gang pop-up floor box assembly, including two 20 amp decorator duplex tamper & weather resistant receptacles, FB-12 box, gasket and cover. DESCRIPTION 1. Turn off circuit breaker prior to installing the floor box. 2. Use Copper Wires only. 3. Do not exceed electrical rating of receptacle. 4. All wiring must be in accordance with all applicable National (NEC/CEC), state, and local codes. 5. 12-10 AWG stranded or solid copper wire is preferred. 6. Contact professional electrician for further installation questions. CAUTION-RISK OF ELECTRIC SHOCK - Compact and stylish design with adjustable height function metal box with the choice of color cover in Brass(C) or Nickel-Plated Brass(S). - Corrosion resistant hardware ensure long life span and reliable performance. - Easy access to power when you need it, and then snap the cover closed when not in use. - Used for carpet and wood floors. Also great for counter-top applications. FEATURE SPECIFICATION Cover Material Receptacle Rating Box: Box Material Knockout Size Adjustable Height Brass(C) or Nickel-Plated Brass (S) 20A 125VAC Pre-galvanized Steel 1/2" and 3/4" Up to 1" depth www.enerlites.com Step 2 Remove knockouts and secure the box onto the floor. Pull the wire through the opening of the floors and knockouts and connect wires based on the wiring diagram. If this product fails within 2 years from the date of purchase due to a defect in material or workmanship, we will repair or exchange it, free of charge. There are no obligations or liabilities on the part of our company for consequential damage arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property, revenue, or product, or cost of removal installation or reinstallation. WARRANTY SIZES AND DIMENSIONS #6-32 Screws Cover Plate Box CAUTION: - Connect wires only when no power is supplied. - Attach the box to the floor using #6 wood screws (not provided). - Attach the cover to the box using #6-32 mounting screws and tighten firmly. INSTALLATION OF THE KIT Before Installation: Ensure there is sufficient depth & space below the sub floor. Step 1 For carpeted floors: Cut out the amount of carpet based on the size of the cover. Follow the rest of the instructions below. For wood sub-floors: Tape the template on the area you want to place the floor box. Use a knife to cut the outline of the box. Start with the ears and move inwards. Cut the box shape without the ears completely through the sub-floor. Cut 1/4" depth into the sub-floor for the mounting ears. Using a router is suggested. Sub Floor Surface Rout 1/4"(6mm) Deep For Outer Tabs Enerlites Inc 201512 Neutral (White wire) Hot (Black wire) Hot (Black wire) Ground (Green or bare wire) For a counter-top installation guide, please visit our website and view the attachments under this product's name.

Transcript of Two Gang Pop-up Floor Box Assembly with 20A Decorator Duplex … · 2017-01-30 · Two gang pop-up...

Page 1: Two Gang Pop-up Floor Box Assembly with 20A Decorator Duplex … · 2017-01-30 · Two gang pop-up floor box assembly, including two 20 amp decorator duplex tamper & weather resistant

4-3/

4"(1

20m

m)

8-11/16"(220mm)

5/16"(7.3mm)

2-3/8

"(61m

m)

7-15/16"(201.6mm)4"(10

1.6mm)

3"(76.2mm

)

Two Gang Pop-up Floor Box Assembly with20A Decorator Duplex Tamper & Weather

Resistant ReceptacleModel Number: 962301-C / 962301-S

WIRING DIAGRAM

Two gang pop-up floor box assembly, including two 20 amp decorator duplex tamper & weather resistant receptacles, FB-12 box, gasket and cover.

DESCRIPTION

1. Turn off circuit breaker prior to installing the floor box.2. Use Copper Wires only.3. Do not exceed electrical rating of receptacle.4. All wiring must be in accordance with all applicable National (NEC/CEC), state,

and local codes.5. 12-10 AWG stranded or solid copper wire is preferred.6. Contact professional electrician for further installation questions.

CAUTION-RISK OF ELECTRIC SHOCK

- Compact and stylish design with adjustable height function metal box with the choice of color cover in Brass(C) or Nickel-Plated Brass(S).

- Corrosion resistant hardware ensure long life span and reliable performance.- Easy access to power when you need it, and then snap the cover closed

when not in use.- Used for carpet and wood floors. Also great for counter-top applications.

FEATURE

SPECIFICATIONCover MaterialReceptacle RatingBox:Box MaterialKnockout SizeAdjustable Height

Brass(C) or Nickel-Plated Brass (S) 20A 125VAC

Pre-galvanized Steel1/2" and 3/4"

Up to 1" depth

www.enerlites.com

Step 2Remove knockouts and secure the box onto the floor. Pull the wire through the opening of the floors and knockouts and connect wires based on the wiring diagram.

If this product fails within 2 years from the date of purchase due to a defect in material or workmanship, we will repair or exchange it, free of charge. There are no obligations or liabilities on the part of our company for consequential damage arising out of or in connection with the use or performance of this product or other indirect damages with respect to loss of property, revenue, or product, or cost of removal installation or reinstallation.

WARRANTY

SIZES AND DIMENSIONS

#6-32 Screws

Cover Plate

Box

CAUTION: - Connect wires only when

no power is supplied. - Attach the box to the floor

using #6 wood screws (not provided).

- Attach the cover to the boxusing #6-32 mounting screws and tighten firmly.

INSTALLATION OF THE KITBefore Installation:

Ensure there is sufficient depth & space below the sub floor.

Step 1 For carpeted floors: Cut out the amount of carpet based on the size of the cover. Follow the rest of the instructions below. For wood sub-floors: Tape the template on the area you want to place the floor box. Use a knife to cut the outline of the box. Start with the ears and move inwards. Cut the box shape without the ears completely through the sub-floor.

Cut 1/4" depth into the sub-floor for the mounting ears. Using a router is suggested.

Sub Floor Surface

Rout 1/4"(6mm) Deep For Outer Tabs

Enerlites Inc 201512

Neutral(White wire)

Hot (Blackwire)

Hot (Blackwire)

Ground(Green orbare wire)