Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment...

12
3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan [email protected] 19th International Workshop on Laser Ranging, Annapolis, 31 Oct 2014 Shinichirou Takakura NTT Communications Corporation, Japan

Transcript of Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment...

Page 1: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan

3036

Two-fold Quality Assessment of Global SLR Data

Toshimichi Otsubo Mihoko Kobayashi

Hitotsubashi University, Japan

[email protected]

19th International Workshop on Laser Ranging, Annapolis, 31 Oct 2014

Shinichirou Takakura

NTT Communications Corporation, Japan

Page 2: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan

Two-fold?

Freshness

Quality

(a) so-called “QC” Daily à Subdaily

> 10 cm

(b) long-term QC ~ 1 year

a few mm

Page 3: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan

Two-fold QC

(a)  Fresh  (but  less  precise)        So-­‐called  “QC”.    1  to  2  weeks  span.      Pass-­‐by-­‐pass  biases  derived  from  POD  residuals.        HIT-­‐U:  6-­‐hourly  report  being  issued.    Auto-­‐detecNon  &  

noNficaNon  implemented.    SARAL  added.      EffecNve  way  to  quickly  find  large-­‐scale  (>  10  cm)  errors.    

(b)  Precise  (but  less  fresh)        Long-­‐term  analysis  (~  1  year).        Already  demonstrated  with  intensity  and  calibraNon  

(2005-­‐06).        Wrt  new  components.              EffecNve  way  to  find  systemaNc  errors  at  a  mm  level.      

Page 4: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan

http://geo.science.hit-u.ac.jp/slr/bias/

Page 5: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan
Page 6: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan

Two-fold QC

(a)  Fresh  (but  less  precise)        So-­‐called  “QC”.    1  to  2  weeks  span.      Pass-­‐by-­‐pass  biases  derived  from  POD  residuals.        HIT-­‐U:  6-­‐hourly  report  being  issued.    Auto-­‐detecNon  &  

noNficaNon  implemented.    SARAL  added.      EffecNve  way  to  quickly  find  large-­‐scale  (>  10  cm)  errors.    

(b)  Precise  (but  less  fresh)        Long-­‐term  analysis  (~  1  year).          Already  demonstrated  with  intensity  and  calibraNon  

(2005-­‐06).        Wrt  new  components.              EffecNve  way  to  find  systemaNc  errors  at  a  mm  level.      

ILRS  Global  Performance  Card  falls  into  this  category.  See  Torrence’s  poster.

Page 7: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan

QC (b): Sorting parameters Test  #1:  Single-­‐shot  returns  per  NP  bin

Test  #2:  Single-­‐shot  RMS  in  a  NP  bin

Test  #3:  System  delay  (calibraNon)

Test  #4:  Time  to  the  nearest  calibraNon

Test  #5:  Range  rate

Test  #6:  Time  of  day

Page 8: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan

Calibration not working properly

Test  #3:  System  delay  (calibraNon)

Page 9: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan

Test  #5:  Range  rate

Time bias (> a few µs) suspected.

Page 10: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan

Day/Night range difference?

Test  #6:  Time  of  day

Page 11: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan

Visit our poster & Attend the clinic session

StaNon-­‐by-­‐staNon  assessment  available      >  1000  charts  in  total!    (To  be  placed  on  the  web  later)      Various  systemaNc  trends  (possible  errors)  detected.      There  is  a  risk  of  false  alarm.    ß  POD  is  not  perfect.        

StaNon-­‐Analyst  interacNon      Enjoy  the  acernoon  session!    

Page 12: Two-fold Quality Assessment of Global SLR Data Shinichirou ... · 3036 Two-fold Quality Assessment of Global SLR Data Toshimichi Otsubo Mihoko Kobayashi Hitotsubashi University, Japan