TW CTR 8 - Extron · 2017. 1. 13. · GENERAL Power Supplied by a 12 VDC, 1 A external power supply...

1
CONTROL — SERIAL PORT Switcher control port (1) 3.5 mm captive screw connector, 3 pole for unidirectional RS-232 control (±5 V) Baud rate and protocol (RS-232) 9600 (default), 19200, 38400, 57600 baud; 8 data bits; 1 stop bit; no parity Pin configuration Pin 1 = Not Used, pin 2 = Tx, pin 3 = GND CONTROL — CONTACT CLOSURE Number/type 8 contact closure inputs and 8 tally outputs Contact closure and tally pin configurations C = Contact, G = Ground, T = Tally, +V = +5V (200 mA max) 200 mA max is shared between all +V pins. GENERAL Power Supplied by a 12 VDC, 1 A external power supply Power input requirements 12 VDC, 0.2 A (no load on Power Out connector) 12 VDC, 1.0 A max (load on Power Out connector) Power consumption Device 2.2 watts, 12 VDC Device and power supply 2.9 watts, 100-240 VAC, 50-60 Hz Thermal dissipation Device 2.4 BTU/hr Device and power supply 4.8 BTU/hr Mounting Rack mount Yes, with optional 1U rack shelf Furniture mount Yes, with included MBU 123 Warranty 3 years parts and labor NOTE: All nominal levels are at ±10%. For complete specifications, please go to www.extron.com Specifications are subject to change without notice. MODEL VERSION DESCRIPTION PART # CTR 8 Contact Closure to RS-232 Control .................................................................... 60-1408-01 1 2 IN1606 5 6 A B 3 4 INPUTS OUTPUTS AUDIO INPUTS OUTPUTS REMOTE HDMI Video and Embedded Audio RS-232 Flat Panel Display Contact Closure and Tally Contact Closure and Tally Power Supply Extron CTR 8 Eight Input Contact Closure to RS-232 Converter Extron IN1606 Scaling Presentation Switcher HDMI “Show Me” Cables VGA “Show Me” Cable RS-232 Ethernet Ethernet TCP/IP Network Extron IPL 250 IP Link Control Processor www.extron.com/teamwork 05-2016 68-2595-01 REV. A1 Letter - English - NP DESCRIPTION The Extron CTR 8 adds contact closure control to most RS-232 controllable Extron single-output simple or scaling switchers, or to an Extron IP Link control processor. It accepts up to eight contact closure inputs and converts them to SIS serial commands that select the corresponding input on an Extron switcher. The contact inputs and tally outputs can be monitored and controlled by an Extron IPLink control processor so it can issue commands to other devices based on the input the CTR 8 receives. Video can be muted and un-muted by pressing a single switch in sequence. FEATURES A Adds contact closure control capability to most RS-232 controllable Extron single-output simple or scaling switchers A +5 VDC output to light an external LED A Video muting control with selectable LED indication mode A +12 VDC loop-out power port CTR 8 Eight Input Contact Closure to RS-232 Converter

Transcript of TW CTR 8 - Extron · 2017. 1. 13. · GENERAL Power Supplied by a 12 VDC, 1 A external power supply...

Page 1: TW CTR 8 - Extron · 2017. 1. 13. · GENERAL Power Supplied by a 12 VDC, 1 A external power supply Power input requirements 12 VDC, 0.2 A (no load on Power Out connector) 12 VDC,

CONTROL — SERIAL PORTSwitcher control port (1) 3.5 mm captive screw connector, 3 pole for unidirectional RS-232

control (±5 V)Baud rate and protocol (RS-232) 9600 (default), 19200, 38400, 57600 baud; 8 data bits; 1 stop bit;

no parityPin configuration Pin 1 = Not Used, pin 2 = Tx, pin 3 = GND

CONTROL — CONTACT CLOSURENumber/type 8 contact closure inputs and 8 tally outputsContact closure and tally pin configurations C = Contact, G = Ground, T = Tally, +V = +5V (200 mA max)

200 mA max is shared between all +V pins.

GENERALPower Supplied by a 12 VDC, 1 A external power supplyPower input requirements 12 VDC, 0.2 A (no load on Power Out connector)

12 VDC, 1.0 A max (load on Power Out connector)Power consumptionDevice 2.2 watts, 12 VDCDevice and power supply 2.9 watts, 100-240 VAC, 50-60 HzThermal dissipationDevice 2.4 BTU/hrDevice and power supply 4.8 BTU/hrMountingRack mount Yes, with optional 1U rack shelfFurniture mount Yes, with included MBU 123Warranty 3 years parts and laborNOTE: All nominal levels are at ±10%.

For complete specifications, please go to www.extron.comSpecifications are subject to change without notice.

MODEL VERSION DESCRIPTION PART #

CTR 8 Contact Closure to RS-232 Control . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60-1408-01

12V

POWER IN

POWER OUT

RS-232

Tx4

C G T +V3

C G T +V2

C G T +V1

C G T +V

8

C G T +V

7

C G T +V

6

C G T +V

5

C G T +V

G

Tx Rx G

1.0AMAX

1.0AMAX

CONTACT IN / TALLY OUT COM

REMOTE

100-240V ~ 50/60 Hz-- A MAX 1

2CONFIGURABLE

HDMI

IN1606

HDMI

5

6 HDMI

A

B

3

4

INPUTS OUTPUTS AUDIO INPUTS OUTPUTS REMOTE

L 1 R

L 2 R

L 3 R

L 4 R

L 5 R

+48V

+48V

1 2

L RVARIABLE

Tx Rx

RS-232

G

LAN

RESET

1

2MIC/LINE

L 6 R

INPUT

LANPOWER12V500mAMAX 1 2 3 4

COM 3 IR3

S G S G

Tx Rx 4RELAY3 4

COM1Tx Rx RTS CTS

COM 2 IR1

S G S G

Tx Rx 2RELAY1 2

HDMI Video andEmbedded Audio

RS-232

Flat Panel Display

Contact Closure and Tally

Contact Closure and Tally

PowerSupply

ExtronCTR 8Eight Input Contact Closure to RS-232 Converter

Extron IN1606Scaling Presentation Switcher

HDMI “Show Me” Cables

VGA “Show Me” Cable

RS-232

Ethernet

Ethernet

TCP/IPNetwork

ExtronIPL 250IP Link Control Processor

www.extron.com/teamwork

05-201668-2595-01REV. A1Letter - English - NP

DESCRIPTIONThe Extron CTR 8 adds contact closure control to most RS-232 controllable Extron single-output simple or scaling switchers, or to an Extron IP Link control processor. It accepts up to eight contact closure inputs and converts them to SIS™ serial commands that select the corresponding input on an Extron switcher. The contact inputs and tally outputs can be monitored and controlled by an Extron IPLink control processor so it can issue commands to other devices based on the input the CTR 8 receives. Video can be muted and un-muted by pressing a single switch in sequence.

FEATURES

A Adds contact closure control capability to most RS-232 controllable Extron single-output simple or scaling switchers

A +5 VDC output to light an external LED

A Video muting control with selectable LED indication mode

A +12 VDC loop-out power port

CTR 8 Eight Input Contact Closure to RS-232 Converter