Turbines and Governing
-
Upload
kvvidyas9538 -
Category
Documents
-
view
42 -
download
10
description
Transcript of Turbines and Governing
![Page 1: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/1.jpg)
STEAM TURBINE
![Page 2: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/2.jpg)
11/16/2014
2
Technical Data, pictures and section drawings - MAA
Lube Oil System - MAV
Control Oil System - MAX
Gland Steam System - MAW
Turbine Drain System – MAL
![Page 3: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/3.jpg)
11/16/2014
3
TSE and Margins
STG Start Up and Shut Down
STG controller
Detailed discussion on Protections
Lub Oil Purification Unit
![Page 4: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/4.jpg)
11/16/2014
4
![Page 5: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/5.jpg)
11/16/2014
5
2 to 3: Isobaric heat rejection (Condenser)
3 to 4: Isentropic compression (Pump)
4 to 1: Isobaric heat supply (Boiler)
1 to 2: Isentropic expansion (Steam turbine )
![Page 6: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/6.jpg)
11/16/2014
6
Steam Parameter Limits
Steam Flow – 325.44 kg/s
Steam Pressures in Bar Absolute
Nominal Long Term Short Term
Main Steam 76.5 85.7 99.5*
Before 1st Stage 75.5 81.5 81.5
Exhaust Steam 2.23 5.0 7.0
Long Term – Upper limit with no time restriction
Short Term – Permissible instantaneous value with cumulative
duration not more than 12 hours in a year.
* - Set the safety valve so as not to exceed this value
![Page 7: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/7.jpg)
11/16/2014
7
![Page 8: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/8.jpg)
11/16/2014
8
![Page 9: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/9.jpg)
11/16/2014
9
![Page 10: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/10.jpg)
11/16/2014
10
Turbine Oil Specs
Mineral or Synthetic oil of viscosity class ISO VG 32 or ISO VG 46 (DIN 51 519)
Capable of withstanding 120 ºC in bearings and 80 ºC in the oil tank without physical or chemical degradation.
Hydraulic Oil – ISO-L-HM46 (DIN 51524-HLP46) capable of withstanding 70 ºC.
![Page 11: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/11.jpg)
11/16/2014
11
Hydro Safe ISO VG 32
Non-Toxic - Biodegradable - Environmentally Friendly Antiwear - Hydraulic Oil
Hydro Safe ISO VG 32 is a vegetable based hydraulic fluid formulated to meet the demand for biodegradable hydraulic oils. It is designed to minimize environmental impact and have low environmental persistance. Hydro Safe ISO VG 32 offers excellent antiwear performance in a wide array of hydraulic components, and can be used as a superior replacement for conventional petroleum oil. It exhibits good thermal and oxidative properties when compared to other vegetable-derived products. Formulated from canola oil, and containing biodegradable, non-toxic chemical additives. Its high vicosity index (VI) allows outdoor operations in winter and summer without the need for fluid changes or equipment modifications.
Viscosity Index ASTM D-567, ASA Z11.45 is an empirical number indicating the rate of change in viscosity of an oil within a given temperature range. A low viscosity index signifies a relatively large change in viscosity with temperature change, while a high viscosity index shows a relatively small change in vicosity with temperature change. Viscosity Index cannot be used to measure any other quality of an oil.
The fluid is totally biodegradable, and exceeds the government criteria of being "readily biodegradable." Readily biodegradable is defined as an attribute of products that have a natural ability to biodgrade quickly and completely. Once the fluid is leaked into the ground, it has the ability of substance to be digested or consumed by naturally occurring microorganisms present in water, air, and soil systems. Complete biodegradability is the conversion of a substance to carbon dioxide and water.
![Page 12: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/12.jpg)
11/16/2014
12
Steam Purity – Why ?
Impurities can cause damage to turbine components by - corrosion, stress corrosion, corrosion fatigue, erosion-corrosion.
Deposition can cause - thermodynamic losses, lower efficiency, upsetting of pressure distributions, clogging of seals and clearances
![Page 13: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/13.jpg)
11/16/2014
13
Values recommended for continuous
operation
Parameter Unit Normal Value Achievable
Value
ACC @ 25 ºC μS/cm < 0.2 0.1
Na μg/kg < 5 2
Silica μg/kg < 10 5
Total Iron μg/kg < 20 5
Total Copper μg/kg < 2 1
Mass weighted averaging for multiple sources. i.e. if A – conductivity
A = ∑Mi * Ai / ∑Mi
![Page 14: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/14.jpg)
11/16/2014
14
Limit Values for Start Up and cases of
deviation from values recommended
for continuous operation. Parameter Unit
Action Level 1
Action Level 2
Action Level 3
Action Level 4
ACC @ 25 ºC μS/cm ≥ 0.2 < 0.35 ≥ 0.35 < 0. 5 ≥ 0.5 < 1.0 ≥ 1.0
Na μg/kg ≥ 5 < 10 ≥ 10 < 15 ≥ 15 < 20 ≥ 20
Silica μg/kg ≥ 10 < 20 ≥ 20 < 40 ≥ 40 < 50 ≥ 50
Total Iron μg/kg ≥ 20 < 30 ≥ 30 < 40 ≥ 40 < 50 ≥ 50
Total Copper μg/kg ≥ 2 < 5 ≥ 5 < 8 ≥ 8 < 10 ≥ 10
Hours per event allowable
h ≤ 100 ≤ 24 ≤ 4 0
Cumulative time per year
h/a ≤ 2000 ≤ 500 ≤ 80 0
![Page 15: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/15.jpg)
11/16/2014
15
Output Limit During Valve Testing
While testing the Main Steam Stop and Control Valves with Automatic Turbine Tester, the Turbine output should be limited to 80%
![Page 16: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/16.jpg)
11/16/2014
16
![Page 17: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/17.jpg)
11/16/2014
17
Turbine Stop & Control Valves
2 Stop and Control Valves each
Stop and CV combined in a common body with stems arranged at right angles
Stop Valve – Single seat valve with integral pilot disk. Hydraulic actuation against spring force – will close in case of power failure to solenoid
CV – Tubular disk with relieving holes. Hydraulic actuation against spring force.
![Page 18: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/18.jpg)
11/16/2014
18
Function – ESV – MAA11/12AA051
Rapid and reliable interruption of Steam Supply to the turbine in case of activation of protection.
To allow admission of steam for warm up of the CV during cold start
![Page 19: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/19.jpg)
11/16/2014
19
Function – CV – MAA12/22AA151
Rapid interruption of Steam Supply to the turbine in case of activation of protection
Allow admission of steam into turbine for warm up during start.
Control the speed gradient during run up to Nominal speed
Control the load of the steam turbine when synchronised
![Page 20: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/20.jpg)
11/16/2014
20
Example
(Not at
S1)
![Page 21: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/21.jpg)
11/16/2014
![Page 22: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/22.jpg)
11/16/2014
22
ST ESV
![Page 23: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/23.jpg)
11/16/2014
23
ST CV
![Page 24: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/24.jpg)
11/16/2014
24
TURBINE EXHAUST
AND SAFETY
VALVES
![Page 25: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/25.jpg)
11/16/2014
25
Lube Oil System - MAV
Safe Oil Supply to Bearings
Jacking up shaft at low speeds
Driving the hydraulic turning device
Avoid escape of oil vapours from the bearings and the oil tank
Oil cooling
Oil Purification
Special Op mode during Fire Protn
![Page 26: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/26.jpg)
11/16/2014
26
Main Components Lub Oil Tank MAV10BB001 2 x 100% LOPs (~ 5.5 Bar) MAV21AP021/022
1 x 100% EOP (~ 2.5 Bar) MAV24AP001 2 x 100% Lift Oil Pps (~ 160 Bar) MAV24AP001
2 x 100% Vapour Extractor fans MAV82AN001/2
2 x 100% Lub Oil Coolers
2 x 100% Lub Oil Filters
Thermostatic Temperature CV
Oil Purification Unit
![Page 27: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/27.jpg)
11/16/2014
27
Thrust Pads
Journal Bearing
![Page 28: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/28.jpg)
Manual Turning Gear Mechanism
![Page 29: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/29.jpg)
11/16/2014
29
Control Fluid System MAX
Supply the ST ESVs, CVs and Safety Valve actuators with high pressure control fluid (160 Bar)
Fast closing/opening of valves when Trip signal actuated.
Transmission of electrical signals from turbine controller into hydraulic signals for fast and accurate positioning of CVs
![Page 30: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/30.jpg)
11/16/2014
30
Main Components
Control fluid tank MAX01BB001
2 x 100% control fluid pps MAX01AP001/002
2 Hydraulic accumulators MAX01BB011/012
2 filters downstream of each pump MAX01AT011/012
1 Circulating oil pump MAX01AP011
1 Control fluid cooler MAX01AC011
Fine mesh filter d/s of cooler MAX01AT013
![Page 31: Turbines and Governing](https://reader034.fdocuments.in/reader034/viewer/2022042503/577cc34f1a28aba711959e0a/html5/thumbnails/31.jpg)
11/16/2014
31
Gland Steam
Extraction Points