Turbina Solar

3

Click here to load reader

Transcript of Turbina Solar

  • SSaattuurrnn MMeecchhaanniiccaall DDrriivvee PPaacckkaaggee OOiill && GGaass

    PPaacckkaaggee UUttiilliittyy RReeqquuiirreemmeennttss SUMMARY

    Electrical System Start System Fuel System Lube Oil System Control System Accessory Equipment Air Inlet System Enclosure

    CUSTOMER: SWECOMEX/PEMEX. PROJECT: KU-S (76211

    (Centrifugal Pump)

    * Rev 6. NOTE: Certified for Construction.

    ELECTRICAL SYSTEM NEC, Class 1, Group D, Division 1 3-Phase AC Power Rating

    - Voltage/Frequency 460 VAC, 60 Hz 2-Phase AC Power Rating Battery Charger - Voltage/Frequency/Phase/Power Rating. 220 VAC, 50/60 Hz, 2, 5 KW Max. 2-Phase AC Lighting and Enclosure Heater Power - Voltage/Frequency/Phase/Power rating. 220 VAC, 50/60 Hz, 2, 200 W Max. 2-Phase AC Motor Space Heater Power Rating All systems except as noted

    - Power 200 W Maximum - Voltage/Phase/Frequency 220 VAC, 2, 50-60 Hz START SYSTEM Pneumatic Start Motor

    - Fluid Natural Gas * - Min/Max Regulated Pressure

    - Min/Max Temperature 140 to 180 psig (9.84 to 12.66 kg/cm2) -28 to +93 deg C

    - Max Inlet Flow 960 SCFM (25.7 nm3/min) - Total Consumption with 60-second Purge 650 SCF (17.4 nm3) - Max Exhaust Vent Back Pressure 0 psig (0 kPag)

    NATURAL GAS FUEL SYSTEM Solar Specification ES 9-98 - Min/Max Gas Fuel Supply Pressure 140 to 180 psig (9.84 to 12.6 kg/cm2)(a) - Max Flow Rate 300 SCFM (8 nm3/min) (a) - Min/Max Fuel Supply Temperature -40 to 160F (-40 to 71C) (b) Notes:

    KU-S (Centrifugal pump) Page 1 of 3 Revised 01/04/05

  • SSaattuurrnn MMeecchhaanniiccaall DDrriivvee PPaacckkaaggee OOiill && GGaass

    (a) Fuel pressure and flow requirements can be affected by several factors such as; fuel temperature, fuel lower heating value, air inlet temperature, fuel composition, fuel specific gravity, engine injector type, inlet duct loss, relative humidity, site elevation, and piping length and diameter. Based on site conditions, minimum fuel pressure and flow requirements may be less than stated values. Please contact Solar Turbines for site-specific fuel pressure and flow requirements.

    (b) Fuel must have a differential temperature (T) of at least 50F (27C) above fuel dew point temperature and be between 40 to 200F (-40 to 93C).

    (c) Fuel pressure must be maintained above engine compressor discharge pressure (Pcd). Pilot Air Valves (required with gas fuel system) NACE System - Fluid Clean, Dry Air - Air Quality Refer to Solar Specification ES 2201 - Min/Max Regulated Pressure Range 100 to 200 psig (7.03 to 14.06 kg/cm2) - Max Flow Rate Less than 10 SCFM (0.27 nm3/min) - Total Fluid Consumption Per Start 2 SCF (0.05 nm3) - Allowable Pilot Vent Back Pressure 0 PSIG (0 Kpag)

    LUBE OIL SYSTEM Solar Specification ES 9-224 AC Pre/Post Lube Pump Motor NEC - Power, Full-Load Amps 1 hp (0.75 kW), 1.5 FLA - Voltage/Phase/Frequency 460 VAC, 3, 60 Hz - Space Heater Power Ratings. 200 W, Space Heater Max. DC Backup Post Lube Pump Motor (By Solar) CSA - Power, Full-Load Amps 0.95 hp, 40 FLA - Flow 11.6 GPM (52.73 L/min) - Supply Voltage 24 VDC AC Motor-Driven Lube Oil Cooler

    Standard Lube Oil Cooler AC Motor NEC - Power 5 hp (3.7 kW) -Voltage/Phase/Frequency

    - Space Heater 460 VAC, 3, 60 Hz 200W Max

    Lube Oil Tank Heater CSA - Power 3 kW - Voltage/Phase/Frequency 220 VAC, 2, 50-60 Hz CONTROL SYSTEM

    On Skid Control System. (By Solar)

    - Voltage 24 VDC - Current Drawn 25 Amps, Steady State Remote Display Remote Desktop PC - Voltage 120 VAC

    Printer/Logger

    - Voltage/Phase/Frequency 220 VAC, 2, 50-60 Hz ACCESSORY EQUIPMENT

    24 VDC Battery/Charger System (By Solar)

    - Control Battery, Type Nickel-Cadmium - Battery Rating 184 ampere-hours - DC Charger Rating 50 ampere

    On-line/On-Crank Engine Cleaning System Solar Specs ES 9-98 / ES 9-62

    KU-S (Centrifugal pump) Page 2 of 3 Revised 01/04/05

  • SSaattuurrnn MMeecchhaanniiccaall DDrriivvee PPaacckkaaggee OOiill && GGaass

    - Water/Solvent Supply Pressure 85 to 100 psig (5.97 to 7.03 kg/cm2) - Minimum Temperature Requirements Must conform to Solar Spec ES 9-62 - On-Line Water/Solvent Flow Rate 0.67 GPM (2.53 L/min) - On-Line Propulsion Air Flow Rate 0.70 SCFM (0.02 nm3/min) - On-Crank Water/Solvent Flow Rate 2.06 GPM (7.79 L/min) - On-Crank Propulsion Air Flow Rate 2.15 SCFM (0.06 nm3/min) - Treatment Tank Capacity 10 gal (37.85 L)

    AIR INLET SYSTEM Electrical System NEC, Class I, Group D, Div 1 Marine Type Air Cleaner Disposable

    ENCLOSURE Electrical System

    - NEC, Class 1, Group D, Division 1 Driver Only Enclosed Ventilation System With Dust Protection Selected - Dual AC Motors, Power 2 Motors, 100%, 2 X 5 hp (2 X 3.75 kW)

    - Voltage/Phase/Frequency 460 VAC, 3, 60 Hz. Barrier Type Air Filter Disposable

    AC Enclosure Lights NEC - Type Fluorescent - 160 Watt Total with built-in backup light & Battery 160 W - Voltage, Phase, Frequency 220 VAC, 2, 50/60 Hz

    KU-S (Centrifugal pump) Page 3 of 3 Revised 01/04/05

    Package Utility RequirementsSUMMARYELECTRICAL SYSTEM

    3-Phase AC Power Rating2-Phase AC Power Rating2-Phase AC Lighting and Enclosure Heater Power2-Phase AC Motor Space Heater Power RatingSTART SYSTEMPneumatic Start Motor

    NATURAL GAS FUEL SYSTEMAC Motor-Driven Lube Oil CoolerLube Oil Tank HeaterCONTROL SYSTEMOn Skid Control System. (By Solar)Remote DisplayPrinter/LoggerACCESSORY EQUIPMENT24 VDC Battery/Charger System (By Solar)AIR INLET SYSTEMElectrical SystemMarine Type Air CleanerENCLOSUREElectrical SystemVentilation SystemBarrier Type Air FilterAC Enclosure Lights