Tunnel Ventilation Attenuators - Caice...attenuator variant perfectly suited to tunnel ventilation...

7
caice.co.uk Tunnel Ventilation Attenuators In the UK MANUFACTURING WITH INNOVATION

Transcript of Tunnel Ventilation Attenuators - Caice...attenuator variant perfectly suited to tunnel ventilation...

  • caice.co.uk

    Tunnel Ventilation Attenuators

    In the UK

    MANUFACTURING WITH INNOVATION

  • We are Caice, a market leader in environmental building products for over 25 years

    An expert manufacturer of attenuation and noise control solutions enabling us to create the most diverse attenuator product range on the market today, with our industrial attenuator variant perfectly suited to tunnel ventilation applications. Through our team of experts we are able to offer a turnkey solution for you. Encompassing acoustic survey, technical design, structural design, project management & manufacture, ensuring every element of your project is covered.

    Our past and current work portfolio demonstrates our ability to fully resource and deliver on the largest and most prestigious of global tunnel ventilation projects.

    Acoustic expertise Survey and acoustic consultancy

    Technical design Designed to meet your noise requirements

    Modular design Lifting points for crane distribution and loading, for easy handling and access restrictions

    Years of low maintenance operation Robust construction for a long life span

    Reversible airflow With separate bullnose fairings for both ends of the splitters

    Off site manufacture Efficient, cost effective and safe

    2 3

    Benefits & Features

    * BS EN ISO 7235:2009 Acoustics laboratory measurement procedures for ducted silencers and air terminal units-insertion loss, flow noise and total pressure loss.

    Accredited performance UKAS accredited testing for insertion loss data to BS EN ISO 7235:2009*

    Easy installation for authorised personnel Detailed drawings and installation method taking account of restrictions to each site

    Authorised for use Included in the London Underground Approved Product Register

    Relevant project experience Over 25 years of current and past projects proves the quality and longevity of our product

    Proactive project management Our professional project managers liaise with you throughout

  • Six Fold Splitter System for years of low maintenance

    Our robust Six Fold Splitter System has been specifically designed and developed for use on tunnel ventilation projects. As these generally require more than just a conventional HVAC attenuator product. Factors such as high pressure, corrosive environments and local airflow conditions dictate that a more resilient product with an extended life span will be required.

    Using our unique system, splitters are constructed with an effective retaining frame thickness of between 2.4mm up to 3.6mm around the total periphery of the splitter face (thickness dependant upon the gauge of material employed).

    The system also allows for the perforated sheet metal facings and bullnose fairings to be mechanically fixed using the same channels, meaning they are continuously retained around the periphery and there are no exposed edges for many years of low maintenance operation.

    With the use of integral woven glass fabric and bespoke manufacturing techniques the product has gained authorisation for use on the London Underground Network.

    Modular and versatile This highly versatile product can be used in a choice of either stand-alone or cased formation, giving improved flexibility of application.

    As a stand-alone system, splitters can be inserted into rectangular and round concrete shafts. Alternatively, the splitters can be added to a purpose made heavy duty casing which could include all of the associated supporting steelwork.

    Splitters are assembled in modules, where required. This allows multiple panels to be bolted together to achieve the required attenuator length.

    Bullnose fairing sections are provided at each end of the splitter, meaning that the system is completely reversible.

    Six Fold Splitter Construction Perforated metal face is retained around the unit’s periphery.

    Modular Splitter Assembly A splitter assembly constructed of modular panels.

    Performance tested We understand the importance of being able to meet the acoustic requirements of any attenuation project.

    This is why having certainty over the noise reduction performance of an attenuator is vital in making sure that any product solution meets your needs.

    Our entire attenuator product range has been performance tested at our testing facility. Fully compliant with BS EN ISO 7235: 2009, for the measurement of insertion loss, flow noise and total pressure loss for ducted silencers, our attenuator performance data is the most accurate in the industry and UKAS accredited.

    Knowing precisely how our products perform means we guarantee noise reduction

    Higher quality and reduced installation time Our comprehensive product range is expertly manufactured at our state of the art production centre in Dorset, UK.

    Off site manufacturing enables us to offer an innovative approach to projects that require an engineering solution to reduce site installation time.

    Whilst this solution enhances quality and site productivity, it also offers improved health and safety and environmental benefits.

    Splitter Line A bespoke piece of machinery at our product centre for automated manufacturer of splitters.

    4 5

    Splitters shown within a fan system.

  • Experience on prestigious projects

    We are currently working on or have provided attenuation and noise control solutions on the following prestigious tunnel ventilation projects.

    Riyadh Metro, Saudi Arabia We’re currently working with the project team to engineer, manufacture and deliver six fold attenuator splitters to control the acoustic environment

    The Northern Line Extension Modular six fold splitter only attenuators and modular six fold cased attenuators were installed in vertical & horizontal shafts as part of the tunnel ventilation.

    Athens Metro Working with G&H Montage on this £1.2M project we provided six fold splitters for inclusion in the builder’s work shafts.

    Docklands Light Railway A range of modular attenuators were supplied to our client, Flakt Woods.

    Heathrow Express This project for Ventilation Sirocco Howden involved a six fold splitter system being installed into the builders work shafts.

    Channel Tunnel Rail Link Heavy duty attenuators were supplied for use within rail tunnels.

    Heathrow Terminal 5 Caice six fold attenuators were supplied to our client, Balfour Beatty, for inclusion in builder’s work shafts.

    The Jubilee Line extension Working with Woods Fans, our modular tunnel ventilation attenuators were installed in vertical & horizontal shafts up to 6000mm square.

    6 7

    Phot

    o cr

    edit:

    © A

    vant

    _Pre

    miè

    re

  • Supporting you every step of the way

    Acoustic survey Our acoustic consultancy division, Lee Cunningham Partnership, are expertly placed to provide survey and consultancy services.

    Working to local authority noise requirements, our experienced team of acoustic consultants and survey technicians can provide an accurate assessment of the likely impact of plant equipment in noise sensitive areas.

    This can prove particularly useful when noise recommendations within a development area change and a reassessment is required.

    Technical design Our technical design team work closely with you to design the best possible solution for your project’s needs.

    Our recommendations can be quickly incorporated into the product design to ensure the most appropriate noise control solution is put in place.

    Our engineers examine factors which influence noise control performance within a ventilation system and optimise conditons to improve air flow ensuring that an effective and efficient system is provided.

    Project management expertsOne of our experienced project managers will be appointed to establish what restrictions there are for delivery and access to your site along with health and safety considerations for installation.

    Throughout the project they will liaise with you and our drawing office team with regular progress meetings to keep you updated.

    Partner with experts who understand you and your challenges

    8 9

  • Noise

    Noise

    Nois

    e

    AirAir

    TUNNEL VENTILATION

    Easy installation for authorised personnel

    We co-ordinate the design of the product to allow for suitable offloading and distribution with specific instructions, as well as detailed drawings so that your authorised personnel can install the products easily and effectively.

    10 11OVER

    ALL ISOME

    TRIC VIEW

    (OUTER W

    ALL NOT SH

    OWN FOR

    CLARITY)

    ISOMETRIC

    VIEW

    (ATTENUAT

    OR ONLY)

    PLAN VIEW

    ATTENUAT

    OR ONLY

    SCALE: 1 :

    50

    ENLARGED

    VIEW: F

    CORNER C

    HAMFER D

    ETAIL

    (4-PLCs)

    VIEW: B-B

    SCALE: 1 :

    50

    ENLARGED

    VIEW: D

    INTEGRAL E

    ND SPACE

    RS AT

    CONNECTIN

    G DAMPER

    JOINT

    ENLARGED

    VIEW: E

    INTEGRAL M

    ID SPACER

    S AT

    CONNECTIN

    G DAMPER

    JOINT

    ENLARGED

    VIEW: G

    TYP SPLITT

    ER FIXING

    THRO' SIDE

    PANELS

    ISOMETRIC

    VIEW

    (ATTENUAT

    OR STEEL

    WORK FRA

    ME)

    ENLARGED

    VIEW: H

    TYP SPLITT

    ER SUPPOR

    T

    FIXING AN

    GLE

    ENLARGED

    VIEW: J

    LOWER MID

    -SPAN SPL

    ITTER SUPP

    ORT BEAM

    PLAN VIEW

    SCALE: 1 :

    75

    VIEW: A-A

    SCALE: 1 :

    75

    ENLARGED

    VIEW: C

    CORNER C

    HAMFER D

    ETAIL

    (4-PLCs)

    ENLARGED

    VIEW: K

    FULLY BO

    LTED COR

    NER CHAM

    FER

    (4-PLCs)

    F

    B

    B

    DE

    G

    H

    J

    A

    A

    C

    K

    ALL DIMEN

    SIONS IN m

    m

    DO N

    OT SCALE

    IF IN DOUB

    T - ASK

    MSCP5 Atm

    osphere V

    ent Attenu

    ator for Sp

    iral Units 1

    ,2,3 & 4

    Elevations

    , Sections a

    nd DetailsT5 Ms

    cp Atmosp

    here Side

    Attenuator

    s

    Proost Mec

    hanical Ins

    tallations B

    V

    General Ar

    rangement

    Riverside H

    ouse, 3 Wi

    nnersh Fie

    lds, Gazelle

    Close, Wi

    nnersh,

    Wokingham

    , Berkshire.

    RG41 5QS

    Tel: 0118 9

    18 6470

    Fax: 0118

    918 6480

    Email: enq

    uiries@cai

    ce.co.uk

    81539-GEN

    -0001

    C.1

    Issued for

    Constructi

    on

    DRAWING T

    ITLEPROJ

    ECT

    CLIENT

    SHEET SIZ

    E

    ISSUE

    DRAWING N

    o.

    A1AS SHO

    WNSCALE

    ISSUE HIS

    TORY

    ISSUE

    NOTES

    DATEDRAW

    N BYCHEC

    KED BY

    A.1

    Issued For

    Approval

    18/12/2017

    NET

    SDS

    A.2

    General Re

    vision

    10/01/2018

    NET

    SDS

    A.3

    Revised as

    Per PMI Co

    mments

    19/01/2018

    NET

    SDS

    C.1

    Issued For

    Constructio

    n

    01/02/2018

    NET

    SDS

    NOTES:

    1. MATER

    IALS ~

    INTERCHA

    NGEABLE M

    ODULAR

    ATTENUAT

    OR ELEME

    NTS (WIT

    H IDENTIC

    AL CONST

    RUCTION /

    MANUFAC

    TURE

    AS PREVI

    OUSLY INS

    TALLED T

    UNNEL SID

    E UNITS)

    SHOP FAB

    RICATED

    FROM THE

    FOLLOW

    ING:

    ROLL-FOR

    MED CHA

    NNEL CAS

    E, INTERN

    AL STIFFEN

    ER AND B

    ULLNOSE

    FAIRING E

    NDS MAN

    UFACTURE

    D FROM

    0.8mm TH

    K FOLDED

    GALVANI

    SED STEE

    L SHEET

    TO BS EN

    10327:200

    4

    ALL ELEME

    NTS FILLE

    D WITH A M

    INERAL W

    OOL ACOU

    STIC MED

    IA SLAB W

    ITH A DEN

    SITY OF 4

    5 Kg/m3

    (MARGLAS

    S CLOTH

    BONDED T

    O FACES

    OF SLABS

    TO PREVE

    NT FIBRE

    INGRESS

    FROM INFIL

    L)

    SIDE PAN

    EL FACING

    S CONTIN

    UOUSLY R

    ETAINED A

    ROUND C

    ASE PERI

    PHERY MA

    NUFACTUR

    ED FROM

    0.7mm

    THK FLAT

    TENED GA

    LVANISED

    STEEL SH

    EET EXPA

    NDED MES

    H TO BS E

    N 10327:20

    04 - ALL

    ELEMENT

    FIXINGS

    TO BE PO

    P-RIVETS

    ONLY (TEK

    SCREW O

    R SELF TA

    PPING TY

    PE FASTE

    NERS NOT

    TO BE US

    ED FOR A

    NY

    FIXING ON

    THESE U

    NITS)

    Ø25 DRAIN

    HOLES P

    ROVIDED

    IN UNDERS

    IDE OF ALL

    ATTENUAT

    OR ELEME

    NTS TO A

    LLOW FOR

    DRAINAG

    E AND

    WATER D

    ISPERSIO

    N

    EXTERNAL

    CASEWO

    RK SHOP

    FABRICAT

    ED FROM

    THE FOL

    LOWING:

    ALL PFC A

    ND RSA R

    OLLED ST

    EELWORK

    FRAME SE

    CTIONS A

    S PER ST

    ANDARD /

    GRADES E

    N 10025/S3

    55 WITH

    A HOT DIP

    GALVANI

    SED FINIS

    H COATIN

    G TO ISO

    1461:2009

    FOLDED P

    ANEL SIDE

    CASING A

    ND CHANN

    EL GUIDE

    S FABRIC

    ATED FRO

    M 2.0mm T

    HK FOLDE

    D GALVAN

    ISED

    STEEL SH

    EET TO B

    S EN 1032

    7:2004

    2. ALL M

    ANUFACTU

    RED ITEM

    S SUPPLIE

    D AS PRE

    -BUILT CO

    MPONENT

    S FOR FIN

    AL ASSEMB

    LY ON SIT

    E. ALL

    ITEMS AR

    E SIZED A

    CCORDIN

    GLY, WIT

    H PROVIS

    ION FOR L

    IFTING AN

    D HANDLI

    NG INTO F

    INAL POS

    ITIONS

    3. NO WE

    LDING ON

    SITE, ALL

    CONNECT

    IONS TO B

    E MECHAN

    ICAL

    4. ALL M

    ETRIC SC

    REW FAS

    TENERS T

    O BE HIGH

    TENSILE

    HEX HEAD

    SETSCRE

    W TYPE (G

    RADE 8.8)

    TO DIN 93

    3

    ZINC PLAT

    ED. ALL L

    OCKING N

    UTS, NYL

    ON INSERT

    TYPE TO

    DIN 6924

    /982 ZINC

    PLATED

    5500

    INSIDE CA

    SING

    5500

    INSI

    DE C

    ASIN

    G

    5500

    UPPER FLA

    NGE FACT

    ORY DRIL

    LED

    TO SUIT E

    XISTING D

    AMPER UN

    IT

    MOUNTIN

    G HOLES

    LOWER F

    LANGE FA

    CTORY DR

    ILLED

    TO SUIT E

    XISTING S

    PACER FR

    AME

    FIXING HO

    LES

    3500

    OVE

    RAL

    L AT

    TEN

    UATO

    R

    2417

    OVE

    RALL

    SPL

    ITTE

    RS

    150

    FAIR

    ING

    1800

    1900

    SUPPORT

    BEAM CTS

    .

    TO SUIT D

    AMPER

    MODULE

    JOINTS

    ESTIMATE

    D OVERAL

    L

    WEIGHT =

    8820 Kg

    TOP OF S

    ILENCER

    +43.079

    5680 ATT

    ENUATOR

    OVER FLAN

    GE

    5500 ATT

    ENUATOR

    INSIDE FLA

    NGE

    5680

    ATT

    ENU

    ATO

    R

    OVE

    R FL

    ANG

    E

    5500

    ATT

    ENU

    ATO

    R

    INSI

    DE F

    LAN

    GE

    180

    180

    255

    3500

    ATT

    ENUA

    TOR

    OVE

    RAL

    L H

    EIG

    HT

    150

    EXIS

    TING

    PFC

    SPAC

    ER F

    RAM

    E27

    65

    SPLI

    TTER

    HEI

    GHT

    150

    FAIR

    ING

    EXISTING

    ATMOSPH

    ERE

    DAMPER

    UNIT NOT

    SHOWN

    FOR CLAR

    ITY

    NB ~ THE

    COMPLET

    E ATTENU

    ATOR ASS

    EMBLY

    IS DESIGN

    ED AND S

    TRUCTURA

    LLY CALCU

    LATED

    AS PER R

    EQUIREM

    ENTS TO A

    CCOMMO

    DATE THE

    WHOLE U

    NIT BEING

    LIFTED O

    UT BY CR

    ANE IN

    ONE PIEC

    E BY ACC

    ESS FROM

    ABOVE

    1200

    SPLI

    TTER

    1200

    SPLI

    TTER

    735

    PLEN

    UM

    9-EQUAL

    PITCHES

    OF NOM 5

    50 = 4950

    NOM 250

    TYP AIRW

    AY

    150

    SIDE SPLI

    TTER

    SECURE A

    LL SPLITTE

    R / PANEL

    AND

    STEELWO

    RK / PANE

    L METAL T

    HREADED

    ASSEMBLI

    ES WITH W

    ITH 'LOCT

    ITE 243'

    THREADLO

    CKING AD

    HESIVE

    300

    TYP CENT

    RE SPLITT

    ERS

    Providing fresh air and a safe and comfortable environment for weary train passengers or vehicle drivers. Whilst up top, they prevent noisy plant and equipment from disturbing neighbours and spoiling the environment for everyone else.

    Our acoustic louvres, enclosures, wall linings and attenuators are all designed to work together in one complete system

  • * Gold Award in the prestigious Command Wessex BEST Awards

    2001, with a “World Class” benchmarked score against

    thousands of other similar businesses throughout the UK and Europe.

    GOLDAWARD

    Won at the prestigious

    COMMAND WESSEX BEST AWARDS

    2001

    t: +44 (0)118 918 6470 f: +44 (0)118 918 6480

    [email protected] caice.co.uk

    Head office & registered office

    Riverside House, Unit 3, Winnersh Fields Wokingham, Berkshire RG41 5QS

    Northern region sales office

    Ground Floor, Units C - E Toller Court, Short Bank Road Skipton, North Yorkshire BD23 2HG

    South west region sales office

    Bank House, Bath Road Chippenham, Wiltshire SN15 2SA

    If you have a tricky question or challenging project then you are in the right place. Our acousticians have specialist expertise and deep experience across a broad range of different types of project.

    Specifying the Tunnel Ventilation Attenuator

    https://twitter.com/CaiceUKhttps://www.linkedin.com/company-beta/3248097/?pathWildcard=3248097https://plus.google.com/+CaiceCoUkmailto:enquiries%40caice.co.uk?subject=Specifying%20the%20Acoustic%20Louvre%20systemhttps://www.caice.co.uk