TUNNEL LIGHTING FIXTURES - … Brochure...TUNNEL LIGHTING FIXTURES 3 HOLOPHANE® Theory and Design...
Transcript of TUNNEL LIGHTING FIXTURES - … Brochure...TUNNEL LIGHTING FIXTURES 3 HOLOPHANE® Theory and Design...
Holophane manufactures three seriesof fixtures for tunnel lighting andunderpass applications. The TunnelPredator® luminaire utilizes optimizedphotometrics for Probeam® andcounterbeam designs. The Wallpack®
Series offers a unique underpassrefractor that redirects light fromdrivers line of sight. The Module 600®
luminaire uses a prismatic glassrefractor for precise control andminimum glare.
Maximum visibility and minimum glareis achieved with any tunnel lightingdesign from Holophane.
TUNNEL LIGHTING FIXTURES
HL-1364 2/02
Definitions/terms
• Tunnel Is defined as a structureover a roadway that restricts thenormal daytime illumination suchthat the drivers visibility issubstantially diminished. Thetunnel is broken down into fivezones:
1) Approach The externalroadway area leading to thetunnel.
2) Portal The plane of entranceinto the tunnel.
3) Threshold zone The areainside the tunnel where a tran-sition is made from the highnatural lighting level outsidethe tunnel to the beginning ofthe transition zone.
4) Transition zone Area whichallows drivers to achieve eyeadaptation by incrementally re-ducing the level of luminance.
5) Interior zone area Withinthe tunnel where eye adap-tation has been completed.
• Under and overpasses Arethose in which the length does notexceed one width of the roadwayunder/over which they areconstructed.
• Tunnel lighting needsAmbient luminance in the principalvisual field of tunnel approaches isthe single most important factor inproviding the driver with safeaccess into the tunnel interior.
• Black-hole effect The effectcreated when a driver’s eyes,adapted to daytime luminancelevels, approaches a non or poorlylit tunnel portal. The driver tends tobreak on approach causing trafficback-ups and the associated risk ofaccidents.
2HOLOPHANE®
TUNNEL LIGHTING FIXTURES
Theory and Design Factors
• Eye adaptation The eyeadapts slowly under dynamicconditions. Therefore in determin-ing the required luminance values atthe tunnel entrance the followingmust be considered:
Time of dayTraffic speedTunnel orientation in relation to
the sunTraffic volumeSurrounding land characteristicsWeather conditionsTunnel architectural featuresDivided and undivided roadwayPavement typeWall and pavement reflectivityFixture veiling luminance (glare)
TUNNEL LIGHTING FIXTURES3 HOLOPHANE®
Theory and Design Factors
Table 1Recommended daytime maintained average pavement luminance levels in the threshold zone of vehicular tunnels (Lth)
Approach Traffic speed Driver directioncharacteristics
km/h mph North East-West Southcd/m2 cd/m2 cd/m2
Open road 100 60 250 310 37080 50 220 260 32060 40 180 220 270
Urban tunnel 100 60 320 280 31080 50 280 240 27060 40 230 200 220
Mountain tunnel 100 60 230 200 20080 50 200 170 17060 40 170 140 140
The figures shown in this Table should be regarded as the basic approximate values of the luminance (Lth)
Table 2Daytime interior zone average luminance recommended on the road (cd/m2)Interior zone average road surface luminance cd/m2
Traffic Traffic flowspeed Low Medium Heavy100km/h (60 mph) 6 8 1080 km/h (50 mph) 4 6 860 km/h (40 mph) 3 4 6
Table 1 and 2: IESNA RP-22
• Lighting design require-ments Whether daytimelighting is to be provided in shorttunnels will depend on speed,volume and geographic condi-tions. When required, the objec-tive of the lighting system is tomeet the visibility requirementsfor day and night conditions. Alltunnels which warrant daytime il-lumination should be providedwith nighttime illumination.
• Daytime luminance Due tothe complexity of tunnelconditions, it is impossible todetermine exact threshold zonedesign values. Table 1 lists baseluminance values for the thresh-old zone. Adjustments to thesecan be made by taking into con-sideration the factors affectingeye adaptation listed above. Tran-sition zone lighting should gradu-ally decrease luminance levelsuntil the interior zone level isachieved.
Interior zone recommendedaverage luminance values arelisted in table 2. Uniformity ratiosshould be 2 to 1 average to min-imum and 3.5 to 1 maximum tominimum. Fixture luminanceshould be 1/3 of the roadwaylevel or less.Tunnel Predator
Larchmount Tunnel, NYLakepark Freeway Tunnel, WIMcCarren Tunnel, NVCarlin Tunnel, NVPali Tunnel, HIWilson Tunnel, HIMonterey Tunnel, CAColumbia Tunnel, WA
Wallpack SeriesCarr P. Duff, PARochester Underpass, NYPhillipsburg Bridge, PAHoan Bridge, WIMall Tunnel, DCTomlinson Bridge, CTVerrazano Bridge, NY
Module 600Airport Tunnel, TNAirport Tunnel, NYLowery Hill Tunnel, MNMacArthur Tunnel, CAMemorial Tunnel, W. VAFounders Tunnel, CTLehigh Tunnel, PAI-695 Tunnel, MIQueen Creek Tunnel, AZMule Pass Tunnel, AZ
Partial Project List
4HOLOPHANE®
TUNNEL LIGHTING FIXTURES• Nighttime luminanceDuring nighttime driving the eyeis adapted to the low outdoor lu-minance levels. The maincriterion is to provide enough lu-minance to ensure safe stoppingto avoid an accident.
• Flicker effect An annoyingsensation caused by the strobo-scopic effect of passing closelyspaced light sources whoseimages or reflected images areseen by vehicle occupants. It isrecommended that luminairespacing be avoided within therange of 5 to 10 cycles persecond.
• Light techniques Two waytunnels: Fixtures are normallywall mounted with eithersymmetric or asymmetricphotometric distributions. Oneway tunnels: Fixtures may be wallor ceiling mounted. Ceilingfixtures may utilize eitherCounterbeam (negative contrast)or Probeam (positive contrast)symmetric and asymmetric lightdistributions.
• Counterbeam lighting Aceiling mounted optical systemdeveloped and used predomin-antly in Switzerland. It is designedto provide high pavementluminance by aiming the mainbeam at the roadway against theflow of traffic. Objects are seen insilhouette using negativecontrast. Maximum candela is ata relatively low vertical angle (45°)with cutoff optical control athigher angles. Fixture spacingmust be carefully analyzed toeliminate the flicker effect thatcan cause driver disorientation.
Application Techniques
45° 45° 45°
90°
Counterbeam
TRANSPORTATION INC.
90°
Probeam
TRANSPORTATION INC.
• Probeam lighting A ceilingmounted optical system that aimsthe main beam with the flow oftraffic. It complements theautomobile headlight system tomaximize visibility throughpositive contrast. The fixture isunseen the driver eliminatingglare and completely eliminatingthe flicker effect. The system pro-vides slightly less pavementluminance than Counterbeam,but all vertical surfaces such ascurbs, walls and other vehicles arebrighter.
In 1995, the IES Progresscommittee cited only one tunnelproject. It was the McCarrenTunnel in Las Vegas, Nevada usingthe Probeam concept withHolophane Tunnel Predatorluminaires.
TUNNEL LIGHTING FIXTURES5 HOLOPHANE®
40
60
80
100
120
140
160
50°45°40°35°30°25°
Ref.* CPD-511 UL insulation manual
Perc
ent o
f rat
ed li
fe
Ambient temperaturevs.
Rated life for integrally ballasted luminaires*
25°C Rated
Luminaires
40°C Rated
Luminaires
Table 3
Application Techniques
• Maintenance consider-ations Mechanical lightingequipment should be specifiedthat is designed and gasketed towithstand washing by high pres-sure sprayers and mechanicalbrushes. If utilized, latches shouldbe captive or shielded to preventaccidental opening during clean-ing cycles. Materials used in lumi-naire manufacture should be cor-rosion resistant and treated towithstand chemical leaching inthe harsh tunnel environment.
• Electrical Ballast and startersshould be selected that providethe longest life possible. Ingeneral, electrical component lifeis extended 100% for each 10°Cit operates under its UL or ETLdesign maximum. (See table 3)
• Access Ballast, starters socketsand lamps should be easilyremoveable to minimize laneclosure time.
6HOLOPHANE®
TUNNEL LIGHTING FIXTURESTUNNEL LIGHTING FIXTURES
• Specialized tunnel opticsFluted reflectors optimizephotometrics for Probeam andCounterbeam designs. Walls areevenly lit and the pavement meetsIES RP-22 luminance requirements
• Glare free environmentInnovative fixture designminimizes ability to view lamp ineither Pro or Counterbeam orien-tation
• Corrosion resistance Fixturedesigned to UL 595 marineoutdoor standards. Constructionconsists of low copper (360.1alloy) aluminum, phosphatepretreatment, 2-4 mil TGICpolyester powder paint, hollowcore high temperature siliconegaskets and stainless steelhardware.
• Unitized electrical assem-bly Quick disconnect fixture doorincludes ballast and socket. Allows60 second replacement and mini-mal downtime.
• Low loss ballasts Optional250 - 400 watt ballasts use grainoriented M-6 grade low loss steelto reduce ballast losses 10 to 20watts per fixture.
• 40°C UL Listing Extendsballast and capacitor life 100percent if operated in 25°Caverage ambients
• Special optics
• Corrosion resistant
• Unitized electrical assembly
• Low loss ballast
Tunnel Predator - Probeam
Traffic FlowLight Beam
TUNNEL LIGHTING FIXTURES7 HOLOPHANE®
• Easy cleaning Passes 100 PSIhosedown test procedure.Gasketed to dust tight standards.Designed for no snag operationwith mechanized cleaner brushes.
• Protected HPS starterProtects starter and ballast fromthermal damage when lamp fails.
• Lamp extinguishing volt-age Standard ballasts can sustain30% or greater voltage dip.
TUNNELS
UNDERPASSES
Traffic FlowLight Beam
Negative Contrast Counterbeam
Positive Contrast Probeam
8HOLOPHANE®
TUNNEL PREDATOR®
Photometrics
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
HORIZANGLE
CANDLEPOWER
VERTANGLE
TESTED BY CERTIFIED BY
TEST NO. 45452
CANDLEPOWER2000 CD/DIV
120°
150°180°
90°
50°
30°0°
HOLOPHANE TPD15DHPXXXPX TUNNEL PREDATOR PROBEAM
150W CLEAR HPS LAMP LUMENS 16000 BULB ED-17
LATERAL DISTRIBUTION (DASHED LINE) IN 42.5 CONESVERTICAL DISTRIBUTION (SOLID LINE) THROUGH 0.0 LATERAL PLANE
TEST DISTANCE: 25 FT. MAX. CANDELLA: 11488
0 11488 0 399815 10068 15 432325 7946 25 576135 5598 35 878945 3836 45 1093855 2683 55 559665 2089 65 297075 1780 75 52585 1647 85 18395 1665 95 11
105 1774 105 8125 2387 125 3145 3803 145 3165 4042 165 2180 4256 180 1
.50
.40
.30
.20
.10
0
Ratio = Distance across/Mounting height
Rat
io =
Dis
tanc
e al
ong/
Mou
ntin
g he
ight
Coefficient of U
tilization (dashed curves)
2 1 0 1 2 3 4 5
5
4
3
2
1
0
TPD15DHPXXXP (Probeam)150W HPS, Test 45452
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
HORIZANGLE
CANDLEPOWER
VERTANGLE
TESTED BY CERTIFIED BY
CANDLEPOWER
120°
150°180°
90°
50°
30°0°
.50
.40
.30
.20
.10
0
Ratio = Distance across/Mounting height
Rat
io =
Dis
tanc
e al
ong/
Mou
ntin
g he
ight
Coefficient of U
tilization (dashed curves)
2 1 0 1 2 3 4 5
5
4
3
2
1
0
TPF400HPXXXP (Probeam)400W HPS, Test 46801
TEST NO 46801
4000 CD/DIV
HOLOPHANE TPF400HPXXXP TUNNEL PREDATOR PROBEAM
400W CLEAR HPS LAMP LUMENS 50000 BULB E-18
LATERAL DISTRIBUTION (DASHED LINE) IN 52.5 CONESVERTICAL DISTRIBUTION (SOLID LINE) THROUGH 25.0 LATERAL PLANE
TEST DISTANCE: 25 FT. MAX. CANDELLA: 25915
0 24352 0 699215 25390 15 679225 25915 25 727035 22510 35 1049345 18776 45 2166455 13239 55 2532065 7898 65 1437175 6414 75 327285 6056 85 20395 5893 95 33
105 5719 105 6125 2372 125 3145 966 145 5165 1683 165 4180 1906 180 2
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
HORIZANGLE
CANDLEPOWER
VERTANGLE
TESTED BY CERTIFIED BY
CANDLEPOWER
120°
150°180°
90°
50°
30°0°
.50
.40
.30
.20
.10
0
Ratio = Distance across/Mounting height
Rat
io =
Dis
tanc
e al
ong/
Mou
ntin
g he
ight
Coefficient of U
tilization (dashed curves)
2 1 0 1 2 3 4 5
5
4
3
2
1
0
TEST NO. 47113
1200 CD/DIV
HOLOPHANE TPF15AHPXXCX TUNNEL PREDATOR COUNTERBEAM
150W CLEAR HPS LAMP LUMENS 16000 BULB E23.5
LATERAL DISTRIBUTION (DASHED LINE) IN 72.5 CONESVERTICAL DISTRIBUTION (SOLID LINE) THROUGH 45.0 LATERAL PLANE
TEST DISTANCE: 25 FT. MAX. CANDELLA: 7004
0 858 0 252515 919 15 307825 1328 25 349535 4459 35 301145 7004 45 293855 3318 55 298165 2704 65 390575 1630 75 412685 937 85 19795 561 95 0
105 421 105 2125 318 125 0145 464 145 3165 658 165 2180 547 180 1
TPF00HPXXXSX (Counterbeam - Crossbeam)150W HPS, Test 47113
PHOTOMETRIC TEST REPORTHOLOPHANEHOLOPHANE RESEARCH & DEVELOPMENT CENTERNEWARK, OHIO 43055
DISTRIBUTION DATA
HORIZANGLE
CANDLEPOWER
VERTANGLE
TESTED BY CERTIFIED BY
CANDLEPOWER
120°
150°180°
90°
50°
30°0°
.50
.40
.30
.20
.10
0
Ratio = Distance across/Mounting height
Rat
io =
Dis
tanc
e al
ong/
Mou
ntin
g he
ight
Coefficient of U
tilization (dashed curves)
2 1 0 1 2 3 4 5
5
4
3
2
1
0
TEST NO. 47783
5000 CD/DIV
HOLOPHANE TPF400HP00XCXX TUNNEL PREDATOR COUNTERBEAM
400W CLEAR HPS LAMP LUMENS 51000 BULB E-18
LATERAL DISTRIBUTION (DASHED LINE) IN 45.0 CONESVERTICAL DISTRIBUTION (SOLID LINE) THROUGH 0.0 LATERAL PLANE
TEST DISTANCE: 25 FT. MAX. CANDELLA: 31127
0 31127 0 729915 28980 15 881325 25394 25 1136835 20337 35 1973645 14469 45 3112755 9800 55 1010365 7067 65 547875 5576 75 44785 4928 85 1695 4797 95 8
105 5134 105 11125 6633 125 13145 9030 145 10165 11605 165 7180 12341 180 2
TPF400HP00XCXX (Counterbeam)400W HPS, Test 47783
TUNNEL PREDATOR®
9 HOLOPHANE®
Performance Specification
The fixture shall be UL 595 Marine
outdoor and UL 1572 40°C listed,
and passed IP65 for Dust-tight and
water jet proof construction.
Mechanical Construction
The housing shall be die cast of alloy
360.1 low copper aluminum with a
minimum thickness of 3mm. It shall be
pre-treated with 100 MG per square
inch of phosphate and overcoated
with an electrostaticly applied 2 to 4
mil coat polyester powder paint cured
at 425°F. The finish shall withstand a
160 inch-pound impact measured
with a standard Gardner Impact Tester.
It shall have passed a 1000 hour salt
spray test as specified by ASTM B-117.
It shall exhibit no cracking or loss of
adhesion from a 180° bend over a 1/8
inch mandrel diameter per ASTM
D522. All external hinges, fasteners
and screws shall be Type 316 stainless
steel or better. Luminaire shall be
designed and suitable for mechanized
cleaners. A luminaire mounting plate,
if specified, shall be 10 gauge Type
304 stainless steel.
Water-tight
No water shall enter the fixture when
exposed to a solid stream of water
from 3 GG40 brass spray nozzles
each supplying 12 gallons per minute
at 100 PSI. The nozzles shall be 30
inches apart, centered on and 24
inches from the fixture plane. Three
tests shall be conducted for 15
minutes each with the vertical
distance of the fixture at 6, 12 and 16
inches above the nozzles. The gasket
shall be hollow core. Durometer 60
silicone with a 200°C continuous
service temperature. It shall have
demonstrated no visible deterioration
after artificial aging for 96 hours in
oxygen at a pressure of 300 pounds
per square inch at a temperature of
156°F per paragraph 43.2 of UL-595.
Dust-tight
The luminaire shall have passed a
dust chamber test in which talcum
powder is maintained in suspension
by an air current. The powder shall be
sized between 1 and 75 micrometers
with at least 50% by weight less than
5 micrometers. At stable
temperature, the luminaire shall be
operated for 1 minute and switched
off and allowed to cool for three
hours while the talcum powder stays
in suspension. When the luminaire is
opened there shall be no ingress of
dust.
Quick Disconnect
Electrical
The fixture door shall contain all
ballast components and be designed
for fast removal as a complete
assembly. Access to the inside of the
fixture housing shall not be required.
Replacement shall take less than 60
seconds.
Optical and Socket Assembly
The reflector shall consist of high
purity alloy # 3002 aluminum of
minimum 0.08 thick sheet. Lens shall
be 4.5 mm minimum thickness tem-
pered glass. The luminaires shall
provide symmetrical or asymmetrical
photometric distribution as specified.
In Counterbeam configuration, the
fixture housing shall shield light at
85° above nadir from the oncoming
drivers eye. In Probeam configura-
tion, the fixture housing shall provide
15° tilt to shield the reflector
completely from view. Lamp holders
shall be porcelain with high tempera-
ture 16 ga. wiring. Sockets shall be
pulse rated at 4k volts. The screw
shell shall be nickel-plated brass with
anti-vibration grips.
Ballast
Shall be copper wound, high power
factor Lead or Low Loss Lead design
as specified. Ballasts shall reliably start
and operate the lamp in ambient
temperatures to minus 40°F. The lamp
extinguishing voltage shall be as low
as 39% of nominal. Ballast shall
provide 100% wattage to the lamp
and have a published Ballast Factor
per ANSI C82.2 of 1.0. The fixture
shall be UL listed for 40°C. When op-
erated at 25°C ambient temperature
ballast and capacitor life shall be ex-
tended approximately 100%. The low
loss ballast available for 250-400 watt
lamps, if specified, shall have a core of
grain oriented M-6 steel to reduce
ballast losses 10 to 20 watts per
fixture. A protected starter for High
Pressure Sodium lamps, if specified,
shall sense an inoperative lamp and
automatically shut down to prevent
continuous pulsing and thermal
damage to itself and the ballast sec-
ondary windings.
Warranty
The electrical assembly shall be
warranted for a period of five years
and the luminaire for a period of two
years from date of shipment.
The physical properties of the
Holophane Tunnel Predator Series
luminaires represent typical average
values obtained in accordance with
accepted test methods and are
subject to normal manufacturing
variations. They are supplied as a
technical service and are subject to
change without notice. Check with
your local Holophane sales represen-
tative to assure current information.
10HOLOPHANE®
TUNNEL PREDATOR®
Product Features and Mounting Options
12
3
4
5
6
1 Low copper (360.1 alloy) die castaluminum. Door does not distortwhen fastened.
2 Unique reflector designeliminates bright streaks, provides uniform illumination, and low surfacebrightness.
3 Optional stainless steel backplate.
4 Removable door with allelectrical components simplifiesmaintenance.
5 Tempered glass lens.
6 Hollow core high temperature gasket prevents water entry duringhosedown.
Stainless steel yoke
Junction box mount
TUNNEL PREDATOR®
11 HOLOPHANE®
Ordering Data
How to construct a catalog number for Tunnel Predator: Fixture type:
EXAMPLE: TPF — 15AHP — 27 — K — CL — 6 — B — PS 1 2 3 4 5 6 7 8
Catalog no. Description
1 Luminaire type
___ TPD Probeam small housing___ TPF Probeam, counterbeam, counterbeam (crossbeam) medium housing
2 Source and wattage**
TPD Probeam (medium base lamps)___ 07DHP 70W HPS ___ 10DHP 100W HPS ___ 15DHP 150W HPS TPF Probeam (mogul base lamps)___ 250HP 250W HPS___ 25LHP 250W HPS (energy saving)___ 400HP 400W HPS___ 40LHP 400W HPS (energy saving)TPF Counterbeam (mogul base lamps)___ 250HP 250W HPS___ 25LHP 250W HPS (energy saving)___ 400HP 400W HPS___ 40LHP 400W HPS (energy saving)TPF Counterbeam (Crossbeam)(mogul base lamps)___ 070HP 70W HPS___ 100HP 100W HPS___ 15AHP 150W HPS
3 Voltage
___ 12 120 volt___ 20 208 volt___ 24 240 volt___ 27 277 volt___ 48 480 volt___ MT Multi-voltage 120 - 277V
4 UL category
___ K Wet location
5 Optical
TPD___ P ProbeamTPF___ P Probeam___ C Counterbeam___ CL* Crossbeam fixture mounted on left with traffic flow (70-150 watt)___ CR* Crossbeam fixture mounted on right with traffic flow (70-150 watt)
6 Mounting
___ 2 Box mount (P optics only) ___ 3 Stainless steel yoke___ 6 304 Stainless steel plate (24” x 30”)
7 Color
___ G Gray___ B Bronze
8 Options and accessories
___ PS Protected starter for HPS lamps___ JB NEMA 4X non-metallic junction box (available with mounting 6 only)
Notes: * Reflector orientation set at factory** Consult TSG for MH lamps
D1
L
D2
CounterbeamTraffic Flow
ProbeamTraffic Flow
Predator TPD TPFW 333mm (13.125”) 419mm (16.5”)L 479mm (17.875”) 533mm (21”)D1 NA 305mm (12”)D2 228mm (8.875”) 272mm (10.625”)
Weight 9-15kg (20-33 lbs.) 18-21kg (39-46 lbs)
12HOLOPHANE®
Product Information
WALLPACK® SERIES• Unique underpass refrac-tor Redirects light from driversline of sight and spreads lightacross multiple lanes of traffic.
• More efficient precisionreflector Provides up to 55%higher street side output thancompetitive units.
• Adjustable optics 50° or60° main beam optimizes one ortwo sided designs and visibility.
• Borosilicate prismaticglass refractor Non-yellowing,precise control with minimumglare.
• Corrosion protection Lowcopper aluminum housing,phosphate pretreatment and 2-4mil polyester powder finishprovides long life where salt andalkali leachate is a problem.
• Protected HPS starterShuts off when lamp fails.Prevents starter failure and ballastthermal damage fromcontinuous operation.
• Multiple wiring accessWallpacks can be wired from sideor back. Wallpack® III featuresoptional thru wiring capability
Underpass Wallpack
Wallpack III
WALLPACK® SERIES13 HOLOPHANE®
Ordering data
How to construct a catalog number: Example: WL3K — 250HP — 12 — BZ — Fixture type________________
1 2 3 4 5 Cat. no. Description
1 Luminaire__ WL2K Wallpack II; UL listed 40°C wet location__ WL3K Wallpack III; UL listed 40°C wet location;
CSA certified
2 Source and wattageWL2K__ 035LP 35W LPS (N/A with “MT”)__ 070HP 70W HPS__ 100HP 100W HPS__ 15AHP 150W-55V HPS__ 100MV 100W mercury__ 175MV 175W mercury__ 250MV 250W mercury (N/A with “MT”)__ 70DMH 70W MH (N/A with 480V)__ 10DMH 100W MH (N/A with 480V)__ 15DMH 150W MH (N/A with 347 or 480V)__ 175MH 175W MH__ 30DIN 300W incandescent, medium base__ 26QFL 26W CF (min. starting temp. 50° F)WL3K__ 250HP* 250W HPS__ 400HP* 400W HPS__ 250MH* 250W MH__ 400MH* 400W MH
3 Voltage__ 12 120V __ 20 208V __ 24 240V__ 27 277V __ 34 347V __ 48 480V __ MT Multi-voltage 120/208/240/277V__ VT Vari-tap 120/277/347V
4 Color __ BZ Bronze__ BK Black__ WH White__ GR Grey
5 Options & accessories__ F1 Single fusing for 120, 240, 277 and 347V; factory installed__ F2 Double fusing for 208, 240 and 480V; factory installed__ PS Protected starter; HPS units only__ TW Thru-wiring (WL3K only)__ U Underpass optics__ Lamp Shipment of appropriate lamp__ WL2KPR12 Photocontrol kit for 120V__ WL2KPR Photocontrol kit for 208, 240 or 277V__ WL2KPR34 Photocontrol kit for 347V__ WL2KTP Tamper-resistant screws__ WL2KWG Wire guard __ WL2KPA Polycarbonate shield; not available with “TW”- thru-wiring option__ TPD1 Driver for tamper-resistant screws
* Available with Vari-tap
370mm(14.5")
200mm(8")
WL2K
290mm(11.5")WL3K
430mm (16.88")250mm (10")
150mm(6")
150mm(6")
50mm(2")
Weight:WL2K 7-11kg (15-25 lbs) WL3K 15-16 kg (32-36 lbs)
11mm (0.44”)dia. mounting(3) holes
DN20NPT (0.75”) threaded conduitentry (withremovable plug)
Knockout for DN40 (1.5”) nipple
14HOLOPHANE®
Product Information
MODULE 600®
• Borosilicate prismatic glassrefractor Non-yellowing, precisecontrol with minimum glare.
• Refractor main beam panelMinimizes lamp brightness,assures uniform luminance andsharp near-cutoff control of themain beam.
• Corrosion protection Lowcopper aluminum housing,phosphate pretreatment and 2-4mil polyester powder finishprovides long life where salt andalkali leachate is a problem.
• Multiple wiring access Canbe wired from sides or back andprovides thruway wiring asstandard.
• Extended ballast life 40°CUL listing provides up to 100%more ballast life in 25°C ambient.
• Protected HPS starter Shutsoff when lamp fails. Preventsstarter failure and ballast thermaldamage from continuous opera-tion.
Module 600
MODULE 600®
15 HOLOPHANE®
Ordering Data
How to construct a catalog number :Example: MW — 100HP — 12 — BZ — PS Fixture type________________
1 2 3 4 5Cat. no. Description
1 Luminaire__ MW Module 600 — UL listed 1572
Wet location, 40°CCSA certified
2 Source & wattage__ 100HP 100W HPS__ 15AHP 150W – 55V HPS__ 200HP 200W HPS__ 250HP 250W HPS__ 400HP 400W HPS__ 175MH 175W MH__ 250MH 250W MH__ 400MH 400W MH__ 175MV 175W MV__ 250MV 250W MV__ 400MV 400W MV
3 Voltage__ 12 120V__ 20 208V__ 24 240V__ 27 277V__ 34 347V__ 48 480V__ MT Multi-voltage for 120/208/240/277V (not available with 250MV & 400MV)__ VT Vari-tap 120/277/347V
4 Color__ Z Bronze__ G Grey __ K Black __ W White
5 Options__ PS Protected starter for HPS units__ AD Conduit adapter__ F1 Single fuse assembly for 120, 240, 277 or 347 volt__ F2 Double fuse assembly for 208, 240 or 480 volt__ QD Quick disconnect__ PR Photocontrol for 120-347 volt units (NA with 480V, MT or VT)
6 Accessories (order separately)__ MWSD Internal light shield__ MWSB Suspension bracket for mounting unit vertically from a horizontal surface__ MWPA Polycarbonate vandal shield
Order number______________ Job name________________
406mm(16”)
406mm(16”)295mm
(11.625”)
254mm (10”)
400mm(15.75”)
400mm (15.75”)
Conduit entry
7/16” knockoutmounting holes(3 provided)
400mm (15.75”)
Thru-wire chamber
Back view of housingshowing mounting details
10”2”
6”7”
1/2” Dia. Hole(Four Places)
7/16” Dia. Hole(Six Places)
11/16” Dia.Hole24”
6.875”
14”
HL-1364 2/02 ©Copyright Holophane 2002 Printed in USA
Acuity Lighting Group, Inc.
214 Oakwood Ave., Newark, OH 43055 /Holophane Canada, Inc. 9040 Leslie Street,Units 8 and 9, Richmond Hill, ON L4B 3M4 /Holophane Europe Limited, Bond Ave., MiltonKeynes MK1 1JG, England / Holophane, S.A. deC.V., Apartado Postal No. 986, Naucalpan deJuarez, 53000 Edo. de Mexico
Contact your local Holophane salesrepresentative for application assistance, andcomputer-aided design and cost studies. Forinformation on other Holophane products andsystems, call the Inside Sales Service Departmentat 740-345-9631. In Canada call 905-707-5830 or fax 905-707-5695.
Limited Warranty and Limitation of LiabilityRefer to the Holophane limited materialwarranty and limitation of liability on thisproduct, which are published in the “Terms andConditions” section of the current productdigest, and is available from our local Holophanesales representative.
Visit our web site at www.holophane.com