T&S real-time QC
description
Transcript of T&S real-time QC
Groom-gliders Trieste data-management meeting
Trieste, June 2013
T&S real-time QC
1. Platform identification : valid wmo ID
2. Impossible date test : year greater than 2000 and not in future
3. Impossible location testLatitude in range −90 to 90 and longitude in range −180 to 180
4. Position on land testComparison with ETOP5 bathymetry : will not work properly
5. Impossible speed test
6. Global range test on T, Spressure ]-5, 3000] dbar, temperature ]-2.5, 40] °C, salinity ]2, 41] psu
7. Regional range test on T, S
Groom-gliders Trieste data-management meeting
Trieste, June 2013
Oxygen real-time quality control
Since November 2012, a real-time QC is applied to Argo floats oxygen data
Argo floats report oxygen in an homogeneous way as– DOXY : micromole/kg
– The oxygen calculation is documented on :http://www.argodatamgt.org/Documentation
Groom-gliders Trieste data-management meeting
Trieste, June 2013
Oxygen real-time quality control
An equivalent quality control will be tested on Glider oxygen data
According to that study, the following settings may be applied for oxygen real-time QC– Global range : -0,5 to 600 micromole/kg– Spike : 100 micromole/kg– Gradient : 100 micromole/kg