Technical Summary Produced: 18.06.2015 Page 1/1 TS-059-SBD265-2LC KYOCERA Document Soluons Service Support/ CWerdelmann TSR2084681 Subject: Sporadic slow prinng and copying Model: TASKalfa 7550ci, 6550ci, 5550ci, 4550ci, 3550ci, 3050ci, 8000i, 6500i, 5500i, 4500i, 3500i, 5551ci, 4551ci, 3551ci, 3051ci, 5501i, 4501i, 3501i, 7551ci, 6551ci, 8001i, 6501i Error codes: -/- Classification: Field measures: Next visit At Maintenance By Case Phenomenon: SC/Error Paper Feeding/Conveying Firmware / Software Image Machine operation Information Related to: SB 2LC-0129-D265 Description: Slow prinng might occur if the environment temperature is less than 18 degrees and the quite mode seng is on. Corrective Measure / Field Measure Compare the real temperature with the temperature which is shown on the service status page (Picture 1). If the temperature sensor works correctly, change “Ready Time Adjust” seng in Sim. U161 from “5” (default) to “0” to compensate low temperature (Picture 1). Picture 1 (57) Temperature inside the machine (58) Temperature outside the machine Picture 2

description

tech note

Transcript of TS-059-SBD265-2LC-UK

  • Technical Summary Produced: 18.06.2015 Page 1/1

    TS-059-SBD265-2LC

    KYOCERA Document Solutions Service Support/ CWerdelmann

    TSR2084681

    Subject: Sporadic slow printing and copying

    Model: l: TASKalfa 7550ci, 6550ci, 5550ci, 4550ci, 3550ci, 3050ci, 8000i, 6500i, 5500i, 4500i, 3500i, 5551ci, 4551ci, 3551ci, 3051ci, 5501i, 4501i, 3501i, 7551ci, 6551ci, 8001i, 6501i

    Error codes: -/-

    Classification: Field measures: Next visit At Maintenance By Case

    Phenomenon: SC/Error Paper Feeding/Conveying Firmware / Software

    Image Machine operation Information

    Related to: SB 2LC-0129-D265

    Description: Slow printing might occur if the environment temperature is less than 18 degrees and the quite mode setting is on.

    Corrective Measure / Field Measure

    Compare the real temperature with the temperature which is shown on the service status page (Picture 1). If the temperature sensor works correctly, change Ready Time Adjust setting in Sim. U161 from 5 (default) to 0 to compensate low temperature (Picture 1).

    Picture 1

    (57) Temperature inside the machine (58) Temperature outside the machine Picture 2