TRX Path Balance Check V1 00
-
Upload
fouad-tehari -
Category
Documents
-
view
32 -
download
2
description
Transcript of TRX Path Balance Check V1 00
-
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 1 of 10
Document
Name
TRX Path-Balance Check SOP Guideline V1.00
Version V1.00 Effective Date 2010-07-31
Document
Code
L1 Based eTOM
Prepared By L2 Based eTOM
Reviewed By L3 Based eTOM
Approved By L4 Based eTOM
Applicability Global Standard
Roles Analysis engineer
Relevant Process/Regulation
Document Name Document Code
-
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 2 of 10
Contents
Relevant Process/Regulation ............................................................... 1
1 Abstract ............................................................................. 3
2 Purpose .............................................................................. 3
Operating Instructions ................................................................... 4
2.1 Link Balance Equations: .......................................................... 4
2.2 Counters used for path-balance Judgment .......................................... 4
2.3 Judgment Criteria ................................................................ 6
2.4 Normal Trend for Path-Balance .................................................... 6
2.5 Weak DL Trend for Path-Balance ................................................... 7
2.6 Weak UL Trend for Path-Balance ................................................... 8
2.7 Misleading Case for Path-Balance ................................................. 9
3 Appendix ............................................................................ 10
4 Support Document(s) ................................................................. 10
5 Related Document(s) ................................................................. 10
6 Record Retention .................................................................... 10
7 Document Preparation/Modification Record ............................................ 10
-
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 3 of 10
1 Abstract
This document instructs engineers how to perform the Base Band Hopping audit.
2 Purpose
This document aims to standardize the operation procedure of Path-Balance Judgment
1. Link balance Equations
2. Counters used for path-balance Judgment
3. Judgment Criteria
4. Normal Balance Trend
5. Weak UL Trend
6. Weak DL Trend
7. Misleading Case
-
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 4 of 10
Operating Instructions
2.1 Link Balance Equations:
UL/DL Path balance difference = UL path loss - DL path loss = (MS real transmit
power-UL Rx_Lev) - (BTS cabinet output power-DL Rx_Lev).
BTS cabinet output power=TRX power-static power class*2 + Power fine tuning -
Combiner loss - DL dynamic PC level*2 + dynamic PBT gain
2.2 Counters used for path-balance Judgment
The below counters define the balance status of the TRX into 11 levels and the balance should be around
level 6
The levels below level 6 indicates the status of the UL
The levels above level 6 indicates the status of the DL
Level 1 Indicates that the UL > DL by 15
Level 1 Indicates that the DL > UL by 15
-
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 5 of 10
BSC 6900 TRX Level Balance Counters UL/DL Path-balance
Diffrence Comment
S462A:Number of MRs (Uplink-and-Downlink Balance Level = 1)(none) X DL
S462B:Number of MRs (Uplink-and-Downlink Balance Level = 2)(none) -14 < x < -11 UL > DL
S462C:Number of MRs (Uplink-and-Downlink Balance Level = 3)(none) -10 < x < -8 UL > DL
S462D:Number of MRs (Uplink-and-Downlink Balance Level = 4)(none) -7 < x < -5 UL > DL
S462E:Number of MRs (Uplink-and-Downlink Balance Level = 5)(none) -4 < x < -2 UL > DL
S462F:Number of MRs (Uplink-and-Downlink Balance Level = 6)(none) -1 < x < 1 Balance
S462G:Number of MRs (Uplink-and-Downlink Balance Level =
7)(none) 2 < x < 4 DL > UL
S462H:Number of MRs (Uplink-and-Downlink Balance Level = 8)(none) 5 < x < 7 DL > UL
S462I:Number of MRs (Uplink-and-Downlink Balance Level = 9)(none) 8 < x < 10 DL > UL
S462J:Number of MRs (Uplink-and-Downlink Balance Level =
10)(none) 11 < x < 14 DL > UL
S462K:Number of MRs (Uplink-and-Downlink Balance Level =
11)(none) X => 15 DL > UL
-
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 6 of 10
2.3 Judgment Criteria
The criteria used to judge if the TRX is Balance or not is as following:
1- `Shape of the graph should be centered on Level 6
2- Sum of Levels (1 + 2) should be Less Than 20 % from the total value of Levels 1 to 11 (around the
20 %)
3- Sum of Levels (10 + 11) should be Less Than 25 % from the total value of Levels 1 to 11 (around the
25 %)
2.4 Normal Trend for Path-Balance
The Normal Trend of the balance means that the measurement should be around level 6 as shown below
-
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 7 of 10
2.5 Weak DL Trend for Path-Balance
Weak DL means that the measurement of the UL Level counters is higher than the DL counters (Levels 1+2
is Higher than 20 % from the total Measurement)
-
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 8 of 10
2.6 Weak UL Trend for Path-Balance
Weak DL means that the measurement of the DL Level counters is higher than the UL counters (Levels
10+11 is Higher than 25 % from the total Measurement)
-
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 9 of 10
2.7 Misleading Case for Path-Balance
In the below case the measurement of Levels 10+11 is 22% which is good and accepted but from the TRX
chart we can see that the TRX suffers from Weak-UL status as shown below
So the conclusion from this case is that:
1- Percentage is just an indication to determine the worst cases
2- The judgment must be done for case by case specially for the TRXs with percentage around 20% for
both UL/DL indicators (Levels 1+2 or Level 10+11)
-
TRX Path-Balance Check Confidentiality:
2012-03-13 Huawei Confidential Page 10 of 10
3 Appendix
Not Required
4 Support Document(s)
No. Document name Document code
1.
5 Related Document(s)
Front-end and Back-end Document name Document Code
6 Record Retention
Record
Name
Hand over
Owner
Retention
Owner
Retention
Location
Filing Date Retention
Period
Disposition at
Expiry
Problem
escalation
(GCRMS)
7 Document Preparation/Modification Record
(Manda tory)
Version
Prepared/Modified
By
Preparation/Modification
Date
Content/Reason for Modification
Approved
By
V1.00 Mostafa Ibrahim
701891
(Egypt 3rd
licence)
2010.8.31 New Version Zhu
yongsheng
108866