www.devi.co.uk DEVI underfloor heating systems A trouble shooting guide

Transcript of TroubleShooter_1.pdf

www.devi.co.ukDEVI underfloor heating systemsA trouble shooting guide2YES NONOYESYES NOYES NONONO YESYESNO*A qualified electrician must carry out all instructions within a shaded box.HEATING ISSUE 1The RCD trips outwhen the system isturned on.HEATING ISSUE 2There is no display onthe thermostat.An electrician shouldvisit the site to ensure allelectrical connectionsand wiring are correct.Are they correct?Is there an earth fault?(Continuity betweenlive/earth orearth/neutral).Exchangethermostat. Is the floorwarming up?Please complete thevisual checks on page 3. Does the product passall three checks?Please complete sections 1 and 2, andreturn to DEVI. You will be contacted assoon as possible. Please wait 24 hrs toevaluate how the systemis performing. Is the floor warming up at all?Please complete sections 1 and 5 andreturn to DEVI. You willbe contacted as soon aspossible.Purchase areplacement thermostatThe electrician shouldconduct a resistance andinsulation test. Is there an open circuit?(No resistance).Please completesections 1 and 2 andreturn to DEVI. You will be contacted assoon as possible.Please make changes tothe wiring/connectionsby using the diagramsavailable atwww.devi.co.uk. Also refer to the back of the thermostat.Please complete sections1 and 3 and return 550to your supplier.Is there a voltage outputfrom the thermostatwhen required? Pleaseuse the test instructionson page 5/6 to set thethermostat.Please complete sections 1 and 4 andreturn to DEVI. You willbe contacted as soonas possible.Please usethe system asrequired.YESYES (heating issue 2 only)Please follow the step-by-step instructions and 3YES NOYESNOIf the error persists, please complete sections 1 and 5 and return to DEVI.HEATING ISSUE 3The floor is notheating up at all.If the issue is notresolved, please completesection 1 and 5 andreturn to DEVI. You will becontacted upon receipt.Is the outer rim on thethermostat flashing?Please ensure that thethermostat is set to thequick set up on page 3.Is the symbolshowing?HEATING ISSUE 4The system is heating,but not performing asI would expect.Please refer to thePerformance TroubleShooter on page 4.Please refer to the userguide/faqs onwww.devi.co.ukcomplete the applicable forms where requiredRead the following fault number on the thermostat and follow instructions.2Configured as a master, but another master isdetectedThermostat incorrectly set during configuration, see step 2, on page 5 and 6. Set to ALO.No Error Action7Clock is not set Set the clock (see page 11 of the devireg 550 user guide, This can be downloaded on www.devi.co.uk). 3Configured as a slave but cannot find any masterunitThermostat incorrectly set during configuration, see step 2, on page 5 and 6. Set to ALO. 4The thermostat has switched itself off, due tooverheatingCall an elecrician, (let the thermostat cool for a period then enter basic set-up to leave errormode). Check all wiring, (diagrams on back ofthermostat and on www.devi.co.uk) and thevisual checks on page 4.5Sensor fault. Floor sensor short circuit Call an electrician (Have an authorisedelectrician check the floor sensor wiring andobtain a resistance reading of 10K - 24K Ohms).The floor sensor may have to be re-wired orreplaced.6Sensor fault. Floor sensor short circuit Call an electrician (Have an authorisedelectrician checkthe floor sensor wiring andobtain a resistance reading of 10K - 24K Ohms).The floor sensor may have to be re-wired orreplaced.devireg 550 test instructions for the devimat floor warming system or areaswhere the thermostat is situated outside of the room (ie. wet areas)Please follow these instructions to ensure that the thermostat is set-up correctly in order to provide power to the heating elements. NB. If the thermostat is displaying CODE initially you will ONLY be presented with step 1 and step 4; set these as described below.Once you have either completed steps 1 and 4, or the controller is displaying something other than CODE, you must press and holdthe button until the word CODE is displayed and follow the steps below. To reset the thermostat, press and hold the button until CODEis displayed.Please note that the setup for older versions can be seen in RED.NB. If the thermostat is flashing at any time, please revert to the Trouble Shooter on page 2.Setup code 12345Rotate button to select code 0044 and then pressbutton once.Rotate button to select ALO and then press the buttonOperatingmode Rotate button to select FS to activate the floor sensor,then press button. This is a floor sensor only selection.Sensorselection Maximumfloortemperatureselection6LO should be displayed, you should rotate the dial toselect -30C then press the button.Off periods7 Rotate the button to select clock display as either 24hours or 12 hours AM/PM.Clock display8Press button once.Save settings9Press and hold button. The display now shows the timeand day (number 1 represents Monday, number 7 isSunday). Rotate the dial to show the correct time andday of the week and then press the button to save thecorrect time setting. Setting theclock10Press the button so there is a black circle around theoutside of the digital display. The thermostat is now inmanual mode.Manual mode11For test purposes, turn the setting up to 10 until is displayed. This may take a few minutes to display. This ensures that the thermostat is sending output to the heating element.This temperature setting is simply for test purposes.When it is apparent that the floor is heating, lower thetemperature immediately. This should be evaluated overa 24 hour period).TesttemperatureAdaptivemodeTemperaturereadout Rotate button to select C and then press buttonRotate button to select AdAP and then press button System Floor constructionTiles Timber Carpetdevimat Timber base 29-32C 27-32C 29-32CdevimatConcrete base 40-45C 29-32C 40-45CAt nt rotate button to select either of the followingtemperature selection, maximum floor temperatures,then press button. 4devireg 550 test instructions for the deviheat total heating systemPleasefollowtheseinstructionstoensurethatthethermostatisset-upcorrectlyinordertoprovidepowertotheheatingelements.If the thermostat is displaying CODE initially you will ONLY be presented with step 1 and step 4; set these as describedbelow.Once you have either completed steps 1 and 4, or the controller is displayng something other than CODE, you must pressandholdthebuttonuntilthewordCODEisdisplayedandfollowthestepsbelow. Toresetthethermostat,pressandholdthebutton until CODEis displayed. Please note that the setup for older versions can be seen in RED.NB. If the thermostat is flashing at any time, please revert to the Trouble Shooter on page 2. System Floor constructionTiles Timber CarpetCableCable screed 40-45C 36C 40-45CCable Timber suspended 36C 36C 36CSetup code 12345Rotate button to select code 0044 and then pressbutton once.Rotate button to select ALO and then press the buttononce.Operatingmode Rotate button to select C and then press button.RotatebuttontoselectrFStoactivatethefloorsensor,thenpressbutton.Thisisaroomandfloorsensorselection. Sensorselection Maximumfloortemperatureselection7LO should be displayed, you should rotate the dial toselect -15 degrees C then press the button.Off periods6This should be set to 0.0, if this is the case, press thebutton to continue. If not, adjust setting and continue.OFFS8 9Press button once.Save settings10Press and hold button. The display now shows the timeand day (number 1 represents Monday, number 7 isSunday). Rotate the dial to show the correct time andday of the week and then press the button to save thecorrect time setting. Setting theclock11Press the button. A black circle around the outside ofthe digital display should be displayed.The thermostatis now in manual mode.Manual mode12For test purposes, turn the temperature up to 35C untilis displayed. This may take a few minutes. Thisensures that the thermostat is sending output tothe heating element.This temperature setting is simplyfor test purposes. When it is apparent that the floor isheating, lower temperature immediately. This should beevaluated over a 24 hour period).TesttemperatureTemperaturereadoutAdaptive modeRotate button to select AdAP and then press buttonClockdisplayRotate the button to select clock display as either24 hours or 12 hours AM/PMAt nt rotate button to select either of the followingtemperature selection, maximum floor temperatures,then press button.56Visual checksVISUAL CHECK ONECracked LCD displayThis fault is caused when someoneattempts to remove the front cover ofthe thermostat. This is normallyremoved by carefully pushing downon the plastic tab in the top centralgrill. If care is not taken, theimplement used to push down thetab slips and damages the display,causing it to crack. This damage canalso be caused by over-tightening ofthe screws.This fault is caused when theelectrics entering the back of thethermostat are stripped back too far,exposing the live conductors. Whenthis happens, if these exposed wirescross, they short and cause the fuseto blow and the back of thecontroller to be blackened.Remove the front cover and inspectthe back of the LCD display. At theback are a set of gold connectorpins, these leave the factorystraight, if they are bent ordistorted then a heavy hand hasbeen used to plug the display intothe base of the thermostat.VISUAL CHECK TWOBlackening at the rear of thethermostatVISUAL CHECK THREEBent pinsThese instructions will help to identify whether the fault with your underfloor heating system has beencaused due to mis-installation/not following user instructions.If these VISUAL checks are carried out correctly, the thermostat may not have to be returned to DEVI, which will save you time.In all three examples, the thermostat would not be covered by the DEVI Warranty. In this case a new thermostat should be purchased.7Performance trouble shooterIf you are still encountering a heating issue, please complete section 1 and 5 and then return to DEVI. Please provide description of all checks carried out, eg. position of floor sensor, checking of maximum floortemperature etc.You will then be contacted as soon as possible.The system is not heating up to therequired temperature, or there is nodifference in performance betweensettings 6 and 10.HEATING ISSUEThe floor temperature hasexceeded the maximumtemperature.POSSIBLE CAUSES Check the maximum floortemperature is set correctly, (see step 5 on pages 6 and 7).ACTIONCheck the positioning of the floorsensor is correct. (Floor sensor shouldbe completely in the conduit eitherparallel to deviheat element ordirectly underneath devimat.)Increase the available heating outputwithin the area by adding asupplementary heating source.Check the LO set-back is set correctly --15 for deviheat, -30 for devimat.Reduce operating temperatures tothe following: deviheat -21-24C, anddevimat (and all operating on floorsensor only - wet areas, 4-7C)Set the timer to come on at thetime when the heat is required, (not before).Ensure that the time periods requiredare displayed on the thermostat andall segments that are outside theintended time periodare clear.Confirm that the floor structure isstandard throughout the floor/build.Confirm that there is a heatingelement beneath the area in questionand that the element has beeninstalled at the same Wm2densityacross the floor.Check the positioning of the sensors.(Floor sensor should be completelywithin the conduit, either parallel tothe heating element or directlyunderneath the devimat. Air sensorshould be positioned away from anyexternal factors that influence the airtemperature surrounding thethermostat and therefore causing thesystem to switch off early.Check electrical connections to thethermostat (page 11 of the userguide) and complete all visual checkson page 4.Press and hold the button so that allsegments around the outside arefilled, then quickly turn the dial anti-clockwise.With devimat systems there may notbe enough output to heat the area.The temperature has lowered to theset LO amount. The system will aim to reach thedisplayed temperature for the timeset. (devireg intelligence based onprevious performance).The system is in manual mode.It is not possible for the element toheat up at variable rates. This is theresult of an external influence onthe system. Eg. Different underlying floor ordifferent floor covering.The air/floor sensors are notreading the correct temperature. This may be a fault caused by afault with the electricalconnections.The thermostat will only switch offin manual mode.The system is heating outside thetime period. The time period isindicated by the black segmentsaround the dial. (This may result inhigh running costs).The floor is heating up at variabletemperatures across the wholefloor. Thefloorisheatingabovethetemperaturerequired.( Thismayresult in high running costs).The thermostat will not switch offThe DEVI warrantyYou have purchased a deviheat system, which we are certain, will a high level of comfort and economy inyour home. deviheat provides a complete heating solutions with deviflex heating cables or devimatheating mats, devireg thermostats and devifast fixing strip.If, however, contrary to all expectations, a problem should occur with your heating system, we at DEVI, withmanufacturing units in Denmark, are, as European Union suppliers, subject to general product liability rules,as stated in Directive 85/374/CEE and all relevant national laws which implies that:DEVI provides a warranty for deviflex heating cables and devimat heating mats for a 10 year period and allother DEVI Products for a 2 year period against defects in material and production.The obligation of DEVI will be to repair or supply a new unit, free of charge without secondary charges linkedto repairing the unit. In case of defective devireg thermostats, DEVI reserves the right to repair the unit freeof charge and without unreasonable delay to the customer. The DEVI warranty only covers connections made by authorised electricians and installations performed inaccordance with the installation instruction and does not cover faults caused by incorrect designs suppliedby others, incorrect installation or any subsequent damage, that may occur.If DEVI is required to inspect or repair any defects caused by any of the above, then all work will be fullychargeable. The DEVI warranty is void, if payment of the equipment is in default.At all times, DEVI will respond honestly, efficiently and promptly to all queries and reasonable requests fromour customers.The above mentioned warranty concerns product liability whereas matters in relation to legislation on saleof goods shall be referred to national law.N.B Unit = DEVI Installed equipment www.devi.co.uk8* Please ignore if the thermostat was purchased through a retail outlet. THESE FORMS CAN BE COMPLETED AT www.devi.co.uk/troubleshooterSection 1 - your detailsFailure to complete all relevant fields and information to DEVI may result in a delay.Name:Company:Company Address:Post code:Customer services Tel.Co. Tel: Mobile:Fax:E-mail address: *Quote number of project (if applicable):Your reference:Site/property contact name:Tel/Mob: Fax:E-mail:Full site address:Post code:Postcode:*Plot number (at time of build):*Development name (at time of build:Section 2 DEVI can locate and repair the damaged heating element. On receipt of this form, DEVI will issue a quoteand a date for this service. In the unlikely event that the damage of the heating element is due to amanufacturing fault, the standard DEVIwarranty applies. Please complete as accurately as possible.Product info Please tick Mat size or cabledevimat timber (100Wm2)devimat concrete (150Wm2)deviflex heating cablesCable/mat checklist YES/NO Resistance (Ohms)Continuity between live-neutralContinuity between live-earthContinuity between neutral-earthContinuity between earth-earthSection 3 Product type:Date of purchase/quote number:The thermostat may need to be returned for testing. Please confirm that the following have been tested byticking the boxes.1. I have set the thermostat in accordance to the instructions within the quick set-up guidesupplied and the following symbol is showing and the outer-rim is not flashing.2.The thermostat has been tested by a competent electrician and it is confirmed that there isNO output coming from the thermostat.3.The visual checks on page 3 have been carried out by a qualified electrician.4. All electrical wiring/connections are in accordance with the wiring diagrams shown onwww.devi.co.uk and this has been confirmed by a competent electrician.If any of the boxes are NOT ticked then refer to the Devi trouble shooter on pageand . If all the boxes have been ticked and checks completed thenplease return your thermoatat to your supplier.Signed: .. Date: Please return the product with this form to your supplier.Section 4Please confirm the following have been tested by ticking the boxes. 1. I have set the thermostat in accordance to the quick set-up guide supplied on page andand the following symbol is showing and the outer-rim is not flashing.2. All electrical wiring/connections are in accordance with the wiring diagrams on the back of the thermostat (or as shown on www.devi.co.uk) and this has been confirmed by acompetent electrician.3. The circuit in the heating element is complete and it has been confirmed that there is notan earth fault (no resistance between live/earth or neutral/earth).4. The thermostat has been tested by a competent electrician and it is confirmed that there isoutput coming from the thermostat. 5.The visual checks on page 4 have been carried out by a competent electrician.If any of the boxes are NOT ticked then refer to the Devi trouble shooter on page 2 and 3. If all the boxes have been ticked and checks completed then please now complete section 5 to giveextra detail of the heating issue you are encountering, then return the forms to Devi. You will becontacted as soon as possible.Signed: .. Date: Please now complete section 5, to give extra detail of the heating issue you are encountering and returnforms to DEVI, you will be contacted as soon as possible.YES NOYES NOPlease return this form to DEVI, you will be contacted as soon as possible.DEVI Electroheat Ltd. Brickfields Business Park Woolpit, Suffolk IP30 9QSF:08454349489 [email protected] www.devi.co.uk/troubleshooterSection 3 Please give a detailed description of the heating issue you are encountering: