TRIGEN IM Nail System. Like no other.
Utilizing the TRIGEN SURESHOT™ Distal Targeting System
©2012-2013 Smith & Nephew, Inc. All rights reserved.71181599 REVA 01/13
Reducing radiation. Increasing efficiency. Simplifying techniques.
TRIGEN™ IM Nail System
Femoral Tibial
INTERTAN™Short and long lengths
META-NAIL™Retrograde Femoral*
FAN (Femoral Antegrade Nail) Standard* and recon* locking options
META-NAIL™ Tibial*TAN™ (Trochanteric Antegrade Nail) Standard* and recon* locking options
HumeralTibial
Humeral Nail Long*, short (straight and bent) options
SURESHOT™ Distal Targeting System*nails that utilize this technology
META-NAIL™ Tibial*TAN™ (Trochanteric Antegrade Nail) Standard* and recon* locking options
Reducing radiation. Increasing efficiency. Simplifying techniques.
Challenge: Radiation exposure
TRIGEN SURESHOT™ Distal Targeting SystemAchieve perfect circles without the use of radiation. Real-time video feedback ensures the proper screw orientation relative to the distal interlocking holes.
Watch the video
Nails that utilize TRIGEN SURESHOT technology.
The TRIGEN™ solution:
Accuracy: Distal locking was 100% successful on 50 procedures using the TRIGEN™ SURESHOT™ System.1
Reduced time: Distal locking time was reduced by an average of 48% compared to the standard fluoroscopy technique.1
Reduced radiation: Regarding radiation emission, fluoroscopy time was reduced by an average of 31 seconds which is the equivalent to approximately 0.663 rad.1
One rad of exposure increases risk of cancer2
TRIG
EN T
AN
™ Tro
chan
teric
Ant
egra
de N
ails
TRIG
EN M
ETA
-NA
IL R
etro
grad
e Fe
mor
al
TRIG
EN M
ETA
-NA
IL™ T
ibia
l
TRIG
EN F
AN
Fem
oral
Ant
egra
de N
ails
TRIG
EN H
umer
al
Nails that utilize TRIGEN SURESHOT technology.
The TRIGEN™ solution:
One base instrument tray for all lower extremity long bones that allows the OR staff to make short work of long bone fractures.
Challenge: Instrumentation efficiency
HoneycombChoose and fine-tune a starting position without constant removal of guide pins.
Specialized instruments
Internal threading allows the hexdriver to rest just inside the screw head to ensure positive contact and prevent screw loss.
Captured Screw Hexdriver
ReducerCurved tip directs the guide rod past the fracture site.
The TRIGEN™ solution:
Challenge:
Dedicated instruments for blocking screws and extension nailing
Tibial fractures
Blocking screws
133 tibia nailing cases showed 58% of proximal tibia fractures were malaligned (>5º angulation).
58%
7% 8%
Malalignment3
Proximal Middle Distal
Nailing in extension
Blocking screws
7mm of compression leads to more control of the reduction and easier, reproducible outcomes.
Threaded holes combined with a multiplanar screw configuration offer a stable, locked construct.
The highest proximal bend allowing for easier insertion with less risk of dislocation.
27mm
10º
Dynamization/compressionslot
Threaded
Threaded
Threaded withpolyethylenebushing
Enhanced fixation
Reduced flexion leads to less pull from the quadriceps muscle, helping to avoid fracture malreductions and malalignment.
Challenge:The TRIGEN™ solution:
Lessen the risk of femoral malrotation. With the TRIGEN SURESHOT™ Distal Targeting System, the leg does not need to be maneuvered for fluoroscopy.4
In the picture the TRIGEN SURESHOT method is shown for the tibia. The setup for TRIGEN SURESHOT for the femur is similar.
Femoral fractures
Inte
rcon
dyla
r fos
saG
reat
er tr
ocha
nter
Pirif
orm
is fo
ssa
In the picture the TRIGEN SURESHOT method is shown for the tibia. The setup for TRIGEN SURESHOT for the femur is similar.
Three femoral entry options Locking hole options
TRIGEN™ FAN Femoral Antegrade Nails
TRIGEN TAN™ Trochanteric Antegrade Nails
TRIGEN META-NAIL™ Retrograde Femoral
Smith & Nephew, Inc.7135 Goodlett Farms Parkway Cordova, TN 38016 USA
Telephone: 1-901-396-2121Information: 1-800-821-5700Orders/Inquiries: 1-800-238-7538
©2012-2013 Smith & Nephew, Inc. All rights reserved.71181599 REVA 01/13
www.smith-nephew.com
™ Trademark of Smith & Nephew. Certain trademarks registered in the US Patent & Trademark Office.
References
1. Michael Hoffmann, MD, MBA, Malte Schro¨der, MD, Wolfgang Lehmann, MD, PhD, Michael Kammal, MD, Johannes Maria Rueger, MD, PhD, and Andreas Herrman Ruecker, MD. Next generation distal locking for
intramedullary nails using an electromagnetic X-ray-radiation-free real-time navigation system. J Trauma Acute Care Surg. 2012; 73: 243-248.
2. Ashmore JP, Krewski D, Zielinski JM, Jiang H, Semenciw R, Band PR. First analysis of mortality and occupational radiation exposure based on the National Dose Registry of Canada. Am J Epidemiol 148(6): 564, 1998
3. Freedman EL, Johnson EE. Radiographic analysis of tibial fractures malalignment following intramedullary nailing. Clin Orthop Relat Res. 1995:25-33.
4. Tornetta P, Patel P, Tseng S, Whitten A, Ricci W. Distal locking using an electromagnetic field guided computer based real time system. Orthopaedic Trauma Association (OTA) Annual Meeting Poster No. 98, 2009