SAT REPORT TRANSFORMER – ABB 11kV/415V substation
Transformer Site Acceptance Test:
Name Plate Details:
Manufacturer
Sl.No
Year of Manufacture
Rating KVA
No. of Phases
Type
Type of Cooling
Frequency (Hz)
Rated Voltage (kV)- HV/LV
Impedance voltage @ 750C (%)
Amp. Temp. 0C
Temperature Rise Oil/Winding 0C
Vector Group Symbol
Rated Current (A)- HV/LV
Oil Quantity (L)
Untaking Mass (kg)
Total Weight (Kg)
Switch Position Connect HV Volts12345
1) Visual Check:
Sl.No Description Remarks
1 Check level and alignment of installed transformer;
2 Check tightness of connections and fastenings
3 Check proper grounding
4 Check wire and cable connections
5 Check cable glands and entrance
6 Check Oil Level
7 Check Marshalling box inspection for cable connection
7 of 13
SAT REPORT TRANSFORMER – ABB 11kV/415V substation
2) Insulation Resistance Test:
Winding Voltage Insulation Resistance (Ω) Remarks
Ref (V) 1min 10min PI Value
HV to Earth 5000
HV to LV 2500
LV to Earth 1000
PI – Polarisation IndexPI = R10 / R1 (dimensionless)
Where,R10 – Resistance at 10th min
R1- Resistance at 1st min
3) Winding Resistance Test:
a) H.V Side
TapsResistance (Ω)
Remarks1U-1V 1V-1W 1W-1U
1
2
3
4
5
c) L.V Side
TapResistance (mΩ)
Remarks2u-2v 2v-2w 2w-2u 2u-2n 2v-2n 2w-2n
3
8 of 13
SAT REPORT TRANSFORMER – ABB 11kV/415V substation
4) Magnetizing Current Test:
Tap NoPry. Applied Voltage Magnetizing Current in mA
RemarksRY YB BR R Y B
1
2
3
4
5
9 of 13
SAT REPORT TRANSFORMER – ABB 11kV/415V substation
5) Magnetic Core Balance test:
Applied Voltage Measured Voltage Remarks
r-n y-n b-n r-n y-n b-n
-- -
- - -
--
-
6) Vector Group Test:
Applied Voltage Measured Voltage Remarks
(V) (V)
1U-1V 1U-2u
1V-1W 1U-2v
1W-1U 1U-2W
Condition: ( for Dyn11) 1V-2u
1W2w <1W2v 1V-2v
1V2v=1V2w 1V-2W
1U2n+1V2n=1U1V 1W-2u
1W-2v
1W-2W
1U-2n
1V-2n
1W-2n
10 of 13
SAT REPORT TRANSFORMER – ABB 11kV/415V substation
7) Turns Ratio Test:
Tap
Applied Voltage (V)
Measured Voltage (V)
Expected Actual Ratio Error
Remarks
1U-1
V
1V-1
W
1W-1
U
2u-2
v
2v-2
w
2w-2
u
2u-2
n
2v-2
n
2w-2
n
1
2
3
4
5
8) Transformer function Test (Aux equipments):
Sr.No Function YES / NO Remarks
1 NCT Sec. terminal connected to SBEF relay
2Shorting link removed after CT loop is closed through SBEF Relay
3 Test Auxiliary circuit
9) Calibration Test: (Simulation)
Winding Temperature Indicator
Ref: Expected Setting in Indicator Actual setting received in Marshalling Box Remarks
Alarm
Trip
11 of 13
SAT REPORT TRANSFORMER – ABB 11kV/415V substation
10) Neutral CT Test:
Name Plate Details
Make and type
CT serial number
Ratio
Accuracy / class
Core designation
Burden
Result:
a) Insulation Resistance Test
PhaseApplied Megger Voltage
for 1MinMeasured values in Ω
RemarksNCT
P-E 1000P-S 1000S-E 500
b) Polarity Test
Ref NCT Remarks
1S1-1S2
c) Winding Resistance Test
RefMeasured values in Ω
RemarksNCT
1S1-1S2
d) MAGNETIZING CHARACTERISTICS TEST OF CT:
As per the attachment
e) Ratio Test:
Primary Current in Amps Sec. current in Amps
25% 50% 75% 100% 25% 50% 75% 100%
EXEPCTED
ACTUAL
12 of 13
SAT REPORT TRANSFORMER – ABB 11kV/415V substation
Tripping CB through SBEF relay
SNAG LIST:
TEST EQUIPMENT DETAILS:
Sl. No Description Make Model Serial No Calibration Due
01
02
03
04
Tested By Witnessed By Witnessed By Witnessed By Approved By
COMPANY SPACEAGE
NAME
SIGNATURE
13 of 13
SAT REPORT TRANSFORMER – ABB 11kV/415V substation
DATE
14 of 13