Quality Procedure - Memo/Correspondence Control and Tracking
Tracking data quality
description
Transcript of Tracking data quality
Tracking data quality
M.Weber, FNAL
2/22/04
M.Weber, FNAL
2
Outline
Data quality Bad runs Reasonable runs
This is more about trackers, for tracking see Tue morning
M.Weber, FNAL
3
Data quality
Detector hardware status Readout
Reconstruction
- Enabled ?- Data integrity
Time evolution / stability
M.Weber, FNAL
4
Bad runs
Flagged manually (with scripts) based on e-log / shifter rating / experts info /run database
– Runs with unrecoverable data are marked as “bad”.– Runs with somewhat lower efficiency that is
measurable are marked as “reasonable”
When one or more readout crates are not included in the run or not in the trigger
M.Weber, FNAL
5
The e-log
Run Type EventsSMT Quality
175030 PDAQ/PHYSICS 55020 GOOD175031 PDAQ/PHYSICS 36106 GOOD175033 PDAQ/PHYSICS 434401 GOOD175034 PDAQ/PHYSICS 0 GOOD
Very good job by shifter, but sometimes…
Run 175033
M.Weber, FNAL
6
SMT more in detail
What makes a run bad?Missing crates.Large scale HV problems.Solenoid
What compromises data quality?Missing VRBs.Threshold screw ups that affect many HDIs.Suspicious examine histos
What does not degrade run quality?Reduced HV on a few HDIs.Disabled HDIs.
M.Weber, FNAL
7
How much do we flag bad ?
SMT 2003:
W/LUMI: 1122 runs with 148.60 pb-1NO LUMI: 91 runs with ? pb-1
BAD: 74 runs with 0.89 pb-1GOOD: 0 runs with 0.00 pb-1REASONABLE: 1134 runs with 147.05 pb-1UNKNOWN: 3 runs with 0.64 pb-1SPECIAL: 2 runs with 0.02 pb-1NO INFO: 0 runs with 0.00 pb-1
M.Weber, FNAL
8
CFT 2003
W/LUMI: 1122 runs with 148.60 pb-1NO LUMI: 91 runs with ? pb-1
BAD: 22 runs with 0.23 pb-1GOOD: 0 runs with 0.00 pb-1REASONABLE: 0 runs with 0.00 pb-1UNKNOWN: 1191 runs with 148.37 pb-1SPECIAL: 0 runs with 0.00 pb-1NO INFO: 0 runs with 0.00 pb-1
M.Weber, FNAL
9
CTT 2003
W/LUMI: 1122 runs with 148.60 pb-1NO LUMI: 91 runs with ? pb-1
BAD: 54 runs with 8.34 pb-1GOOD: 637 runs with 99.22 pb-1REASONABLE: 134 runs with 15.71 pb-1UNKNOWN: 385 runs with 25.32 pb-1SPECIAL: 3 runs with 0.01 pb-1NO INFO: 0 runs with 0.00 pb-1
M.Weber, FNAL
10
Post shutdown data verification
See ADM talks 12/15/03 and 12/19/03
Before 178721 After 185868
M.Weber, FNAL
11
SMT
Recovered HDI Lost one more…
M.Weber, FNAL
12
CFT
M.Weber, FNAL
13
Tracking
M.Weber, FNAL
14
Problematic HDIs…
M.Weber, FNAL
15
Conclusions / Comments
In 2003 5% runs are bad (<1 %lumi, ~4%CTT) Flagging BAD at Lumi block level ?
Not manually ! SMT is not worse CFT lost % channels There are a lot of monitoring plots in RecoCert,