Personal Wireless Monitor For Carbon Dioxide The ToxiRAE Pro CO 2 is the world’s first wireless personal carbon dioxide monitor. It provides safety professionals with wireless remote access to real-time instrument readings and alarm status for better visibility and faster incident response. The ToxiRAE Pro offers datalogging capability and is equipped with a “Man Down” alarm and policy enforcement to ensure greater safety while making sure compliance-related procedures such as periodic testing and calibration are performed. • Wireless remote monitoring enhances worker safety • Man Down Alarm with real-time wireless remote notification • Easy to maintain, with replaceable sensor, filter, and Li-Ion battery • Fully automatic bump testing and calibration with AutoRAE 2 KEy FEAtuREs Wireless. Personal. Proven. • Wireless access to real-time instrument readings and alarm status from any location • Unmistakable five-way local and remote wireless notification of alarm conditions • Intelligent sensor stores calibration data, so it can be swapped in the field • Largest display in its class • Continuous datalogging • Easy to use • Reliable and rugged INDustRIEs • Chemical manufacturing • Food and beverage • Wineries and breweries • Landfills • Water and wastewater facilities The world’s first personal wireless monitor for carbon dioxide ToxiRAE Pro CO 2

Transcript of ToxiRAE Pro CO2 Datasheetmetermall.godohosting.com/product/Honeywell/ToxiRAE Pro... · 2014. 12....

Page 1: ToxiRAE Pro CO2 Datasheetmetermall.godohosting.com/product/Honeywell/ToxiRAE Pro... · 2014. 12. 10. · ToxiRAE Pro CO2 Personal Wireless Monitor For Carbon Dioxide DS-1085-02 toxIRAE

Personal Wireless Monitor For Carbon Dioxide

The ToxiRAE Pro CO2 is the world’s first wireless personal carbon dioxide monitor. It provides safety professionals with wireless remote access to real-time instrument readings and alarm status for better visibility and faster incident response.

The ToxiRAE Pro offers datalogging capability and is equipped with a “Man Down” alarm and policy enforcement to ensure greater safety while making sure compliance-related procedures such as periodic testing and calibration are performed.

• Wirelessremotemonitoringenhancesworkersafety

• ManDownAlarmwithreal-timewirelessremotenotification

• Easytomaintain,withreplaceablesensor,filter,andLi-Ionbattery

• FullyautomaticbumptestingandcalibrationwithAutoRAE2

KEyFEAtuREs

Wireless. Personal. Proven.

•Wirelessaccesstoreal-timeinstrumentreadingsandalarmstatusfromanylocation

•Unmistakablefive-waylocalandremotewirelessnotificationofalarmconditions

•Intelligentsensorstorescalibrationdata,soitcanbeswappedinthefield

•Largestdisplayinitsclass

•Continuousdatalogging

•Easytouse

•Reliableandrugged

INDustRIEs

•Chemicalmanufacturing

•Foodandbeverage

•Wineriesandbreweries

•Landfills

•Waterandwastewaterfacilities

The world’s first personal wireless monitor for carbon dioxide

ToxiRAE Pro CO2

Page 2: ToxiRAE Pro CO2 Datasheetmetermall.godohosting.com/product/Honeywell/ToxiRAE Pro... · 2014. 12. 10. · ToxiRAE Pro CO2 Personal Wireless Monitor For Carbon Dioxide DS-1085-02 toxIRAE

spEcIFIcAtIoNs

ToxiRAE Pro CO2Personal Wireless Monitor For Carbon Dioxide

DS-1085-02

toxIRAEpRoco2coMEsWIth:

•ToxiRAEProCO2monitorwithsensorasspecified,alligatorclip,protectiverubberboot,andrechargeablebatteryinstalled

•ChargingandPCcommunicationcradle•PCcommunicationcable•ACadapter(100to240V,50/60HzACto12VDC)•Calibrationadapters•QuickStartGuide•CDwithdocumentation•ProRAEStudioIIsoftwareforPC-basedinstrumentconfigurationanddatamanagement

•Calibrationcard,qualitycertificate,andwarranty/registrationcard

optIoNALAccEssoRIEs

•AutoRAE2AutomaticTestandCalibrationSystem•Multi-unitchargingstationforuptofivemonitors

oRDERINgINFoRMAtIoN(MoDEL:pgM-1850)

•Wirelessornon-wirelessversionsareavailable1

•ContactyourlocalRAESystemsdistributorforpartnumbersformonitors,accessories,maintenancekits,gas,sensors,andreplacementparts

Size 4.6"Hx2.4"Wx1.2"D(118x60x30mm)Weight 7.76oz.(220g)Sensor Nondispersiveinfraredsensor

Range:0to50,000ppmResolution:100ppm

Battery RechargeableLi-ionbattery-Operatingtime:>11hours(normaloperation25˚C/77˚F,non-wireless)-Rechargetime:<4hoursthroughchargingcradle

Display GraphicalLCDdisplaywithwhiteLEDbacklighting(activatedwhenmonitorisinalarmorwithabuttonpress)

DisplayReadout -Real-timereadingofgasconcentrationsinpartspermillion(ppm);batterystatus;dataloggingon/off;wirelesson/off,andreceptionquality-STEL,TWA,andpeakvalues

Keypad 2buttonsforoperationandprogrammingSampling DiffusionCalibration AutomaticwithAutoRAE2TestandCalibrationSystemormanualAlarmModes -Wirelessremotealarmnotification;audible(95dB@30cm),vibration,

visiblealarm(flashingbrightredLEDs),andon-screenindicationofalarmconditions.-ManDownAlarmwithpre-alarmandreal-timeremotewirelessnotification

Datalogging -Continuousdataloggingwithathree-monthcapacity(atone-minuteintervals)-User-configurabledatalogginginterval(from1to3,600seconds)

CommunicationandDataDownload

-DatadownloadandinstrumentsetuponPCviachargingandPCcomm.cradle-DatadownloadviaAutoRAE2AutomaticTestandCalibrationSystem-Wirelessdataandstatustransmission1viabuilt-inRFmodem(optional)

WirelessNetwork ProRAEGuardianReal-TimeWirelessSafetySystemorClosed-LoopNetworkwiththeEchoViewHost

WirelessFrequency ISMlicense-freebandsWirelessRange(Typical)

ToxiRAEProtoMeshRouterorEchoViewHost~660feet(200meters)ToxiRAEProtoRAELink3MeshorRAELink3Z1Meshmodems~330feet(100meters)

OperatingTemperature -4°to131°F(-20°to55°C)Humidity 0%to95%relativehumidity(non-condensing)DustandWaterResistance

IP-65

HazardousLocationApprovals

Unitcannotbeusedinhazardousarea

CECompliance(EuropeanConformity)

EMCdirective:2004/108/EC.R&TTEdirective:1999/5/EC

Warranty -Twoyearsonnon-consumablecomponents-Oneyearonallothersensors,battery,andotherconsumableparts

1WirelessunitshaveafunctioningRFmodemandarereadyforwirelessdeployments.Non-wirelessunitscannotbeupgradedtowireless.Additionalequipmentand/orsoftwarelicensesmayberequiredtoenableremotewirelessmonitoringandalarmtransmission.

Specificationsaresubjecttochange.

www.raesystems.com

AutoRAE 2 with ToxiRAE Pro cradles

coRpoRAtEhEADquARtERsRAEsystemsbyhoneywell3775NorthFirstStreetSanJose,[email protected]

WoRLDWIDEsALEsoFFIcEsusA/canada 1.877.723.2878Europe +45.86.52.51.55MiddleEast +00971.4.440.5949china +86.10.5885.8788-3000Asiapacific +852.2669.0828